Please click here to check who's online and chat with them.

Find Verified Diesel Engine Generator Actuator Zd200R Suppliers, Manufacturers and Wholesalers

Nov-23-22
 
EAP 165
Engine:
Engine Model : 1106A-70TAG2
Stand By kVA: 165
Stand By kW : 132
Prime kVA: 150
Prime kW : 120
Rated Current : 216

Engine
heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed

Alternat
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm

Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â?? ground)

Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system

Engine
Engine Model 1106A-70TAG2
Number of Cylinders 6 Inline
Injection System Direct
Compression Ratio 18,2 : 1
Bore 105
Strok 135
Displacement Lt 135
Air Intake Turbocharged and Air Charge cooled
Speed (RPM) 1500
Oil Capacity Lt 18
Standby Power kw / Hp 149,1 / 202
Prime Power Hp 136 / 184
Fuel Type Euro Diesel
Governor System Mechanical
Cooling System Water Cooling
Coolant Capacity Lt 22
Fuel Consumption (lt / h) Lt Full Load 33,2
Lt %75 LOAD 24,5
Lt %50 LOAD 16,2

Frequency Hz
Power kVA 165
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation 1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8

Weight (Silent) Kg 1950
Weight (Open) Kg 1710
Width (Silent) Mm 1000
Length (Silent) Mm 3150
Height (Silent) Mm 1700
Fuel Tank Capacity Lt 250

1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
Nov-17-22
 
EAP 150
Engine Model : 1106A-70TG1
Stand By kVA: 150
Stand By kW : 120
Prime kVA: 136
Prime kW : 110
Rated Current : 195

Engine
heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed

Alternat
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm

Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis ground)

Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system

Engine Model 1106A-70TG1
Number of Cylinders 6 Inline
Injection System Direct
Compression Ratio 18,2 : 1
Bore 105
Strok 135
Displacement Lt 7,01
Air Intake Turbocharged
Speed (RPM) 1500
Oil Capacity Lt 18
Standby Power kw / Hp 135,8 / 183,5
Prime Power Hp 122,7 / 166
Fuel Type Euro Diesel
Governor System Mechanical
Cooling System Water Cooling
Coolant Capacity Lt 22
Fuel Consumption (lt / h) Lt Full Load 30,1
Lt %75 LOAD 21,9
Lt %50 LOAD 15,2

Frequency Hz
Power kVA 150
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8

Weight (Silent) Kg 1890
Weight (Open) Kg 1650
Width (Silent) Mm 1000
Length (Silent) Mm 3150
Height (Silent) Mm 1700
Fuel Tank Capacity Lt 250

1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
Nov-10-22
 
EAP 110
Engine Model : 1104C-44TAG2
Stand By kVA: 110
Stand By kW : 88
Prime kVA: 100
Prime kW : 80
Rated Current : 144

Engine
heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed

- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm

Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis ground)

Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system

Engine
Engine Model 1104C-44TAG2
Number of Cylinders 4 Inline
Injection System Direct
Compression Ratio 18,2 : 1
Bore 105
Strok 127
Displacement Lt 4,4
Air Intake Turbocharged - Air to Air Cooled
Speed (RPM) 1500
Oil Capacity Lt 8
Standby Power kw / Hp 80.7 / 109
Prime Power Hp 73.4 / 99
Fuel Type Euro Diesel
Governor System Mechanical
Cooling System Water Cooling
Coolant Capacity Lt 13
Fuel Consumption (lt / h) Lt Full Load 22
Lt %75 LOAD 16,9
Lt %50 LOAD 11,1

Frequency Hz
Power kVA 110
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation 1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8

Weight (Silent) Kg 1480
Weight (Open) Kg 1290
Width (Silent) Mm 1000
Length (Silent) Mm 2800
Height (Silent) Mm 1500
Fuel Tank Capacity Lt 210

1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
Nov-01-22
 
EAP 70
Engine: PERK S
Engine Model : 1104A-44TG1
Stand By kVA: 70
Stand By kW : 56
Prime kVA: 64
Prime kW : 51
Rated Current : 92

Engine
heavy duty diesel engine
12V starter and charge alternator
Replaceable air, fuel and oil filters
Mechanical governor control
Tropical type radiator
Flexible fuel hose
Oil drain valve and extension hose
Industrial type silencer and steel compensator
Maintenance-free starter battery
Water jacket heater
1500 rpm engine speed

Alternat
IP 21-23 Protection Standard
H Insulation Class
50 Hz Frequency
4 pole brushless synchronous type alternator
Automatic Voltage Regulator (AVR)
400/230V AC Output Voltage - 1500 rpm

Sound Proof Canopy and Chassis
Convenient design for easy lifting and carrying
High standard sound proof canopy design
Modular design with easily removable nuts - bolts
Lockable doors
Transparent window for watching Control Panel
Electrostatic powder painted, providing protection against harsh weather conditions
Emergency STOP button
Fuel tank inside the chassis
Anti-vibration wedges (engine - chassis and chassis ground)

Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system

Engine
Engine Model 1104A-44TG1
Number of Cylinders 4 Inline
Injection System Direct
Compression Ratio 17.25 : 1
Bore 105
Strok 127
Displacement Lt 4,4
Air Intake Turbocharged - Air to Air Cooled
Speed (RPM) 1500
Oil Capacity Lt 8
Standby Power kw / Hp 65,6 / 88,5
Prime Power Hp 59,6 / 80,5
Fuel Type Euro Diesel
Governor System Mechanical
Cooling System Water Cooling
Coolant Capacity Lt 13
Fuel Consumption (lt / h) Lt Full Load 14,6
Lt %75 LOAD 11
Lt %50 LOAD 8

Frequency Hz
Power kVA 79
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation 1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8

Weight (Silent) Kg 1280
Weight (Open) Kg 1100
Width (Silent) Mm 1000
Length (Silent) Mm 2400
Height (Silent) Mm 1500
Fuel Tank Capacity Lt 180

1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
GOLD Member
Jul-31-18
Supplier From Doral, United States
12379 Diesel Engine Generator Actuator Zd200R Suppliers
Short on time? Let Diesel Engine Generator Actuator Zd200R sellers contact you.
SILVER Member
Aug-20-24

Diesel Oil En590

$530
MOQ: Not Specified
Supplier From Kota Bharu, Kelantan, Malaysia
 
EN 590 Gas Oil specification table explained.

Diesel EN590 10 PPM is a type of diesel fuel that meets the European standard EN590 for automotive diesel oil. The 10 PPMâ?? refers to the maximum sulphur content of the fuel, which is 10 parts per million (ppm) or less.

Low-sulphur diesel fuels such as EN590 10 PPM are required in many parts of the world to meet emissions regulations and reduce air pollution. The lower sulphur content in the fuel allows diesel engines to operate more efficiently and with less emissions of harmful pollutants such as particulate matter and nitrogen oxides.

EN590 10 PPM diesel fuel is commonly used in modern diesel engines, including those in passenger cars, trucks, buses, and heavy equipment. It is typically available at fuel stations that offer diesel fuel, and is used in many countries throughout Europe and around the world.

Contact us for Specification Sheet.
Oct-21-22
 
EAP 50
Engine: PERKNS
Engine Model : 1103A-33TG1
Stand By kVA: 50
Stand By kW : 40
Prime kVA: 45
Prime kW : 36
Rated Current : 65

Engine
- PERKNS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed

Alternat
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm

Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis ground)

Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system

Engine PERKNS
Engine Model 1103A-33TG1
Number of Cylinders 3 Inline
Injection System Direct
Compression Ratio 17.3: 1
Bore 105
Strok 127
Displacement Lt 3,3
Air Intake Turbocharged
Speed (RPM) 1500
Oil Capacity Lt 7,9
Standby Power kw / Hp 45,6 / 61,6
Prime Power Hp 41,3 / 56
Fuel Type Euro Diesel
Governor System Mechanical
Cooling System Water Cooling
Coolant Capacity Lt 18
Fuel Consumption (lt / h) Lt Full Load 10,8
Lt %75 LOAD 8,2
Lt %50 LOAD 5,8

Frequency Hz
Power kVA 50
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation 1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8

Weight (Silent) Kg 1100
Weight (Open) Kg 940
Width (Silent) Mm 950
Length (Silent) Mm 2300
Height (Silent) Mm 1400
Fuel Tank Capacity Lt 145

1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
Oct-14-22
 
EAP 17
Engine: PERK NS
Engine Model : 403A-15G1
Stand By kVA: 17
Stand By kW : 13,6
Prime kVA: 15,4
Prime kW : 12,3
Rated Current : 22,1

Engine
- PERK NS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed

Alternat
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm

Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â?? ground)

Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system

Engine PERKNS
Engine Model 403A-15G1
Number of Cylinders 3 Inline
Injection System InDirect
Compression Ratio 22.5:1
Bore 84
Strok 90
Displacement Lt 1,49
Air Intake Naturally Aspirated
Speed (RPM) 1500
Oil Capacity Lt 6
Standby Power kw / Hp 13,2 / 17,7
Prime Power Hp 12 / 16,1
Fuel Type Euro Diesel
Governor System Mechanical
Cooling System Water Cooling
Coolant Capacity Lt 6
Fuel Consumption (lt / h) Lt Full Load 3,9
Lt %75 LOAD 2,9
Lt %50 LOAD 2

Frequency Hz 50
Power kVA 15
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation 1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8

Weight (Silent) Kg 545
Weight (Open) Kg 500
Width (Silent) Mm 950
Length (Silent) Mm 2000
Height (Silent) Mm 1200
Fuel Tank Capacity Lt 125

1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
Sep-28-22
 
EAC 825
Engine
Engine Model : KTA38-G2
Stand By kVA: 825
Stand By kW : 660
Prime kVA: 750
Prime kW : 600
Rated Current : 1080
Engine
heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternat
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine
Engine Model KTA38-G2
Number of Cylinders 12 - V TYPE
Injection System Direct
Compression Ratio 14.5:1
Bore 159
Strok 159
Displacement Lt 38
Air Intake Turbocharged, Aftercooled
Speed (RPM) 1500
Oil Capacity Lt 135
Standby Power kw / Hp 731 / 980
Prime Power Hp 664 / 890
Fuel Type Euro Diesel
Governor System Electronic
Cooling System Water Cooling
Coolant Capacity Lt 350
Fuel Consumption (lt / h) Lt Full Load 167
Lt %75 LOAD 128
Lt %50 LOAD 90
Frequency Hz
Power kVA 825
Voltage V 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation 1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8
Weight (Silent) Kg 9250
Weight (Open) Kg 8100
Width (Silent) Mm 2200
Length (Silent) Mm 6200
Height (Silent) Mm 2800
Fuel Tank Capacity Lt 1750
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
Sep-15-22
 
EAC 790
Engine: CUMMNS
Engine Model : KTA38-G1
Stand By kVA: 790
Stand By kW : 632
Prime kVA: 718
Prime kW : 574
Rated Current : 1033

Engine
- CUMMNS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed

Alternat
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm

Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis ground)

Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system

Engine CUMMNS
Engine Model KTA38-G1
Number of Cylinders 12 - V TYPE
Injection System Direct
Compression Ratio 14.5:1
Bore 159
Strok 159
Displacement Lt 19
Air Intake Turbocharged, Aftercooled
Speed (RPM) 1500
Oil Capacity Lt 135
Standby Power kw / Hp 701 / 953
Prime Power Hp 634 / 862
Fuel Type Euro Diesel
Governor System Electronic
Cooling System Water Cooling
Coolant Capacity Lt 350
Fuel Consumption (lt / h) Lt Full Load 158
Lt %75 LOAD 122
Lt %50 LOAD 86

Frequency Hz
Power kVA 550
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation 1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8

Weight (Silent) Kg 9200
Weight (Open) Kg 8050
Width (Silent) Mm 2200
Length (Silent) Mm 6200
Height (Silent) Mm 2800
Fuel Tank Capacity Lt 1750

1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
Aug-04-22
 
EAC 750
Engine: CUMM NS
Engine Model : QSK19-G11
Stand By kVA: 740
Stand By kW : 592
Prime kVA: 672
Prime kW : 538
Rated Current : 968

Engine
CUMM NS heavy duty diesel engine
12V starter and charge alternator
Replaceable air, fuel and oil filters
Mechanical governor control
Tropical type radiator
Flexible fuel hose
Oil drain valve and extension hose
Industrial type silencer and steel compensator
Maintenance-free starter battery
Water jacket heater
1500 rpm engine speed

Alternat
IP 21-23 Protection Standard
H Insulation Class
50 Hz Frequency
4 pole brushless synchronous type alternator
Automatic Voltage Regulator (AVR)
400/230V AC Output Voltage - 1500 rpm

Sound Proof Canopy and Chassis
Convenient design for easy lifting and carrying
High standard sound proof canopy design
Modular design with easily removable nuts - bolts
Lockable doors
Transparent window for watching Control Panel
Electrostatic powder painted, providing protection against harsh weather conditions
Emergency STOP button
Fuel tank inside the chassis
Anti-vibration wedges (engine - chassis and chassis ground)

Optional
Thermal magnetic CB (for automatic models)
Super Silent Canopy
Mobile Generator Sets
Automatic fuel filling system
Synchronization panel
3 Pole and 4 Pole ATS (Automatic Transfer Switch)
Fuel Heater, Oil Heater
External fuel tank and automatic fuel filling system
Fuel - water separator filter
Remote monitoring and control system

Engine CUMM NS
Engine Model QSK19-G11
Number of Cylinders 6 - Inline
Injection System Direct
Compression Ratio 15.9 : 1
Bore 159
Strok 159
Displacement lt 19
Air Intake Turbo Aftercooler
Speed (RPM) 1500
Oil Capacity lt 80
Standby Power kW / Hp 667 / 907
Prime Power kW / Hp 606 / 827
Fuel Type Euro Diesel
Governor System Electronic
Cooling System Water Cooling
Coolant Capacity lt 42
Fuel Consumption (lt / h) lt Full Load 135
lt %75 LOAD 103
lt %50 LOAD 69,5

Frequency Hz 50
Power kVA 740
Voltage V 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation 1%
Insulation Class H
Protection Standard IP21 - IP23
Power Factor 0,8

Weight (Silent) Kg 5750
Weight (Open) Kg 4900
Width (Silent) mm 1900
Length (Silent) mm 4800
Height (Silent) mm 2700
Fuel Tank Capacity lt 1350

1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
Jul-26-22
 
EAC 690
Engine: CUMM NS
Engine Model : KTAA19-G6A
Stand By kVA: 690
Stand By kW : 552
Prime kVA: 630
Prime kW : 505
Rated Current : 910
Engine
- CUMM NS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternat
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â?? ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine CUMM NS
Engine Model KTAA19-G6A
Number of Cylinders 6 Inline
Injection System Direct
Compression Ratio 13.0:1
Bore 159
Strok 159
Displacement L 19
Air Intake Turbocharged, Aftercooled
Speed (RPM) 1500
Oil Capacity L 38
Standby Power kw / Hp 610 / 825
Prime Power kw / Hp 554 / 750
Fuel Type Euro Diesel
Governor System Electronic
Cooling System Water Cooling
Coolant Capacity L 75
Fuel Consumption (lt / h) L Full Load 148,3
L %75 LOAD 112,7
L %50 LOAD 76,4
Frequency Hz
Power kVA 550
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation 1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8
Weight (Silent) Kg 5200
Weight (Open) Kg 4530
Width (Silent) Mm 1900
Length (Silent) Mm 4800
Height (Silent) Mm 2400
Fuel Tank Capacity L 1450
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnt permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
Jul-07-22
 
EAC 650
Engine: CUMMNS
Engine Model : KTAA19-G6
Stand By kVA: 650
Stand By kW : 520
Prime kVA: 590
Prime kW : 472
Rated Current : 849
Engine
- CUMMNS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternat
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â?? ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine CUMMNS
Engine Model KTAA19-G6
Number of Cylinders 6 Inline
Injection System Direct
Compression Ratio 13.0:1
Bore 159
Strok 159
Displacement Lt 19
Air Intake Turbocharged, Aftercooled
Speed (RPM) 1500
Oil Capacity Lt 38
Standby Power kw / Hp 570 / 770
Prime Power Hp 518 / 700
Fuel Type Diesel
Governor System Electronic
Cooling System Water Cooling
Coolant Capacity Lt 75
Fuel Consumption (lt / h) Lt Full Load 140
Lt %75 LOAD 104,9
Lt %50 LOAD 74,5
Frequency Hz
Power kVA 550
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation 1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8
Weight (Silent) Kg 5190
Weight (Open) Kg 4510
Width (Silent) Mm 1900
Length (Silent) Mm 4800
Height (Silent) Mm 2400
Fuel Tank Capacity Lt 1450
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnt permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
Jun-23-22
 
EAC 550
Engine: CUMMNS
Engine Model : KTA19-G3A
Stand By kVA: 550
Stand By kW : 440
Prime kVA: 500
Prime kW : 400
Rated Current : 720
Engine
- CUMMNS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternat
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â?? ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine CUMMNS
Engine Model KTA19-G3A
Number of Cylinders 6 Inline
Injection System Direct
Compression Ratio 13.9:1
Bore 159
Strok 159
Displacement L 19
Air Intake Turbocharged & Intercooled
Speed (RPM) 1500
Oil Capacity L 38
Standby Power kw / Hp 504 / 675
Prime Power kw / Hp 448 / 600
Fuel Type Euro Diesel
Governor System Electronic
Cooling System Water Cooling
Coolant Capacity L 75
Fuel Consumption (lt / h) L Full Load 107
L %75 LOAD 82,3
L %50 LOAD 56,4
Frequency Hz
Power kVA 550
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation 1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8
Weight (Silent) Kg 5085
Weight (Open) Kg 4410
Width (Silent) Mm 1900
Length (Silent) Mm 4800
Height (Silent) Mm 2400
Fuel Tank Capacity L 1450
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnt permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
Apr-08-22
 
EAC 220
Engine: CUMM NS
Engine Model : 6CTAA8.3-G2
Stand By kVA: 220
Stand By kW : 176
Prime kVA: 200
Prime kW : 160
Rated Current : 288

Engine
- CUMM NS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed

Alternat
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm

Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis ground)

Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system

Engine CUMMNS
Engine Model 6CTAA8.3-G2
Number of Cylinders 6 Inline
Injection System Direct
Compression Ratio 18.0:1
Bore 114
Strok 135
Displacement L 8,3
Air Intake Turbocharged Air Aftercooled
Speed (RPM) 1500
Oil Capacity L 23,8
Standby Power kw / Hp 203 / 272
Prime Power kw / Hp 183 / 245
Fuel Type Euro Diesel
Governor System Electronic
Cooling System Water Cooling
Coolant Capacity L 12,3
Fuel Consumption (lt / h) L Full Load 45
L %75 LOAD 34
L %50 LOAD 23

Frequency Hz
Power kVA 220
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation 1
Insulation Class H
Protection Standard IP22 - IP23
Power Factor 0,8

Weight (Silent) Kg 2190
Weight (Open) Kg 1850
Width (Silent) Mm 1200
Length (Silent) Mm 3500
Height (Silent) Mm 1850
Fuel Tank Capacity L 360

1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
GOLD Member
Mar-01-19

Atmospheric Water Generator

$12.00K
MOQ: 1  Pair
Sample Available
 
This Atmospheric Water Generator is a state-of-the-art water generating Appliance using the latest technology available to the industry. EcoloBlue designed your Atmospheric Water Generator with one objective in mind: produce the maximum amount of high quality drinking water using only a minimum amount of electricity. In addition to atmospheric water production, the Appliance can also be used as a conventional water purifier by connecting it to an external municipal (city) water source.
GOLD Member
Oct-29-24
Supplier From Busan, South Korea (Republic Of Korea)
 
The Mercury Verado 250 is a high-performance outboard motor known for its power and reliability. Here are some key specifications:
Engine Type: 4.6L V8
Horsepower: 250 hp
Steering: Digital Throttle & Shift (DTS)
Starter: Electric
Shaft Length: Available in 25" (X-Long) and 30" (XX-Long)
Power Trim & Tilt: Yes
Fuel System: Electronic Fuel Injection (EFI)
Alternator: 115-amp
Weight: Approximately 600 lbs (272 kg)
Cooling System: Water-cooled with thermostat & pressure-controlled
The Verado 250 also features the Advanced MidSection (AMS) for reduced vibration and noise, and Adaptive Speed Control (ASC) for maintaining engine RPM despite changes in load or conditions12.
GOLD Member
VERIFIED
Mar-19-20
Supplier From Bangalore, Karnataka, India
Jul-19-13
 
50/60HZ,220/400V,water-cooled,1500/2000rmp/min,3phases,4wires, 20kwa-1000kwa,Power factor0.8 lag,open/silent type
ATON is able to be your original equipment manufacture by using your authorized logo,brand name,graph design etc.

over 1000kg
Apr-23-08
Supplier From Seongnam, South Korea (Republic Of Korea)
 
Diesel engine generator

20~1, 000 kva
3ph, 4p
1500rpm (50hz)
1800rpm (60hz)
12379 Diesel Engine Generator Actuator Zd200R Suppliers
Short on time? Let Diesel Engine Generator Actuator Zd200R sellers contact you.
Explore Diesel Engine Generator Actuator Zd200R related import export discussions