Please click here to check who's online and chat with them.

Find Verified Current Transformer Iron Core Suppliers, Manufacturers and Wholesalers

Jan-06-12

Current Transformer Iron Core

$18
MOQ: Not Specified
Supplier From Beijing, Shunyi Dist, China
 
Application areas:
Measuring-level current transformer used in power system, transformer used on precision measuring instruments (such as watt-hour meter).

According to the requirements of different measurement accuracy of the transformer, different soft magnetic materials can be chosen as iron core materials. The higher the permeability of the iron core is, the smaller the measurement error of the transformer is, hence the accuracy is higher. At present, the most common iron core material is cold-rolled silicon steel sheet, followed by Permalloy and nano-crystalline glass alloy.

In recent years, demands for transformers with high-precision level (such as class 0.2, class 0.2Sand class0.5S) increased rapidly. When small ratio, low ampere turns are required or the iron core is restricted because of the small volume, the cold-rolled silicon steel often fails to meet the accuracy requirements. Although the Permalloy iron cores with high permeability can meet the required precision, its price is very high.

However use of nano-crystalline alloy iron cores can both meet the accuracy requirements and be produced at lower cost than the Permalloy. Therefore, the demand of measuring level current transformer iron core made of nano-crystalline alloy rapidly increased domestically.

The typical parameters comparison of the common soft magnetic materials used for current transformer iron cores:

Basic parameters
Nano-crystalline iron core
Permalloy (1J85) iron core
Silicon steel iron core

Saturation magnetic flux density (Bs)
1.25T
0.75T
2.03T

Initial permeability (¦Ì0)
8¡«12, 104
5¡«8, 104
103

Maximum permeability (¦Ìm)
60, 104
60, 104
4, 104

Curie Temperature (¡æ)
570
400
740

Density (g/cm3)
7.25
8.75
7.65

Lamination factor
0.7
0.9
0.95

Thickness (mm)
0.03
0.15
0.3


Features:

It is made of the iron-based nano-crystalline strips with a moderate saturation magnetic induction, high permeability and low loss, which can effectively reduce ratio difference angle difference of the transformer. The saturation magnetic induction Bs of nano-crystalline alloy is between the silicon steel and Permalloy.

The lower the Bs value is, the lower the security coefficient of the instrument is. When the system failure occurs and large current through the current transformer results therefore, the iron core is more easily filled, and the secondary current no longer increases in proportion, as can assure that the secondary instruments are well protected and not to be damaged. Permeability of nano-crystalline alloy is close to Permalloy and a magnitude higher than silicon steel, so it is suitable to be made as high-precision transformer iron core.

The density and lamination coefficient of nano-crystalline is lower than that of Permalloy, under the condition of the same size and similar performance of the two. In this case the nano-crystalline iron core is 1/4 lighter in weight, and 1/3 lower in the manufacturing cost. In addition, the linear range of nano-crystalline alloy is wider than that of Permalloy .It can work for a long time at temperature of -55 ~ 130 ¡æ ,with a good temperature stability.


Specifications

a. Rectangular core: (mm)

Iron Core Size(mm)
(mm)

The case size(mm)
Weight of the iron Core

(kg per piece)
Turns Ratio

N1: N2
Excitation current(mA)
Excitation voltage(mV)

55*97/77*119, 25
50*92/82*114, 30
0.53
1:1
25
0.45

95
2.2

1500
53

70*90/100*120, 30
65*85/105*125, 36
0.81
1:1
200
15

1:1
500
50

75*95/105*125, 25
70*90/110*130, 30
0.7
1:1
70
2

1:1
175
8

80*95/120*135, 25
75*90/125*140, 30
1.09
1:1
80
1.7

1:1
600
41

90*90/160*160, 30
85*85/165*165, 36
2.4
1:1
100
6

1:1
500
100

1:1
1000
140

135*135/260*260, 10
130*130/265*265, 16
2.3
1:1
100
1.5

1:1
500
32

82*602/138*658, 45
75*595/145*665, 55
8.8
1:1
100
1.2

1:1
1000
45

1:1
2000
120


b. Ring core:
No.
The iron Core Size
Case size(mm)
The weight of the iron core (kg per piece)
Turns ratio N1: N2 is 1:1; Input current (mA), 50Hz; Output voltage (mV)

1
1105/1165, 15
1095/1175, 25
8.35
Excitation current
450
1200
2000


Excitation voltage
0.59
2.36
5.28


2
415/520, 15
409/526, 23
6.08
Excitation current
50
250
700


Excitation voltage
0.4
3
11


3
305/490, 15
299/496, 23
9.1
Excitation current
350
900
¡¡


Excitation voltage
5
20
¡¡


4
315/395, 35
309/401, 43
8.2
Excitation current
120
400
¡¡


Excitation voltage
3
11
¡¡


5
198/248, 30
192/254, 37
2.76
Excitation current
100
200
500
1000

Excitation voltage
2
6
35
90

6
198/248, 20
192/254, 27
1.84
Excitation current
100
200
500
1000

Excitation voltage
1.5
3.5
25
60

7
155/200, 30
150/205, 36
2
Excitation current
100
190
1000


Excitation voltage
2.5
9.5
80


8
140/180, 30
135/185, 36
1.58
Excitation current
40
80
240


Excitation voltage
1
2.9
15


9
130/190, 30
125/195, 36
2.38
Excitation current
40
80
240


Excitation voltage
1.2
3.8
17


10
100/140, 30
95/145, 36
1.19
Excitation current
30
120
500


Excitation voltage
0.85
6.8
68


11
90/130, 30
85/135, 36
1.09
Excitation current
30
120
500


Excitation voltage
0.7
6
55


12
90/125, 25
85/130, 31
0.78
Excitation current
30
120
500


Excitation voltage
0.9
7
70


13
80/120, 30
75/125, 36
0.99
Excitation current
200
500
¡¡


Excitation voltage
20
65
¡¡


14
85/115, 30
80/120, 36
0.74
Excitation current
30
120
500


Excitation voltage
0.7
6.5
55


15
85/125, 20
80/130, 26
0.7
Excitation current
30
120
500


Excitation voltage
0.62
5.5
50.



wooden case+carton box.
Jan-06-12

Current Transformer Iron Core

$18
MOQ: Not Specified
Supplier From Hefei, Anhui, China
 
Application areas:
Measuring-level current transformer used in power system, transformer used on precision measuring instruments (such as watt-hour meter).

According to the requirements of different measurement accuracy of the transformer, different soft magnetic materials can be chosen as iron core materials. The higher the permeability of the iron core is, the smaller the measurement error of the transformer is, hence the accuracy is higher. At present, the most common iron core material is cold-rolled silicon steel sheet, followed by Permalloy and nano-crystalline glass alloy.

In recent years, demands for transformers with high-precision level (such as class 0.2, class 0.2Sand class0.5S) increased rapidly. When small ratio, low ampere turns are required or the iron core is restricted because of the small volume, the cold-rolled silicon steel often fails to meet the accuracy requirements. Although the Permalloy iron cores with high permeability can meet the required precision, its price is very high.

However use of nano-crystalline alloy iron cores can both meet the accuracy requirements and be produced at lower cost than the Permalloy. Therefore, the demand of measuring level current transformer iron core made of nano-crystalline alloy rapidly increased domestically.

The typical parameters comparison of the common soft magnetic materials used for current transformer iron cores:

Basic parameters
Nano-crystalline iron core
Permalloy (1J85) iron core
Silicon steel iron core

Saturation magnetic flux density (Bs)
1.25T
0.75T
2.03T

Initial permeability (¦Ì0)
8¡«12, 104
5¡«8, 104
103

Maximum permeability (¦Ìm)
60, 104
60, 104
4, 104

Curie Temperature (¡æ)
570
400
740

Density (g/cm3)
7.25
8.75
7.65

Lamination factor
0.7
0.9
0.95

Thickness (mm)
0.03
0.15
0.3


Features:

It is made of the iron-based nano-crystalline strips with a moderate saturation magnetic induction, high permeability and low loss, which can effectively reduce ratio difference angle difference of the transformer. The saturation magnetic induction Bs of nano-crystalline alloy is between the silicon steel and Permalloy.

The lower the Bs value is, the lower the security coefficient of the instrument is. When the system failure occurs and large current through the current transformer results therefore, the iron core is more easily filled, and the secondary current no longer increases in proportion, as can assure that the secondary instruments are well protected and not to be damaged. Permeability of nano-crystalline alloy is close to Permalloy and a magnitude higher than silicon steel, so it is suitable to be made as high-precision transformer iron core.

The density and lamination coefficient of nano-crystalline is lower than that of Permalloy, under the condition of the same size and similar performance of the two. In this case the nano-crystalline iron core is 1/4 lighter in weight, and 1/3 lower in the manufacturing cost. In addition, the linear range of nano-crystalline alloy is wider than that of Permalloy .It can work for a long time at temperature of -55 ~ 130 ¡æ ,with a good temperature stability.


Specifications

a. Rectangular core: (mm)

Iron Core Size(mm)
(mm)

The case size(mm)
Weight of the iron Core

(kg per piece)
Turns Ratio

N1: N2
Excitation current(mA)
Excitation voltage(mV)

55*97/77*119, 25
50*92/82*114, 30
0.53
1:1
25
0.45

95
2.2

1500
53

70*90/100*120, 30
65*85/105*125, 36
0.81
1:1
200
15

1:1
500
50

75*95/105*125, 25
70*90/110*130, 30
0.7
1:1
70
2

1:1
175
8

80*95/120*135, 25
75*90/125*140, 30
1.09
1:1
80
1.7

1:1
600
41

90*90/160*160, 30
85*85/165*165, 36
2.4
1:1
100
6

1:1
500
100

1:1
1000
140

135*135/260*260, 10
130*130/265*265, 16
2.3
1:1
100
1.5

1:1
500
32

82*602/138*658, 45
75*595/145*665, 55
8.8
1:1
100
1.2

1:1
1000
45

1:1
2000
120



Note: Iron cores of other specifications can be provided upon request of users




b. Ring core:
No.
The iron Core Size
Case size(mm)
The weight of the iron core (kg per piece)
Turns ratio N1: N2 is 1:1; Input current (mA), 50Hz; Output voltage (mV)

1
1105/1165, 15
1095/1175, 25
8.35
Excitation current
450
1200
2000


Excitation voltage
0.59
2.36
5.28


2
415/520, 15
409/526, 23
6.08
Excitation current
50
250
700


Excitation voltage
0.4
3
11


3
305/490, 15
299/496, 23
9.1
Excitation current
350
900
¡¡


Excitation voltage
5
20
¡¡


4
315/395, 35
309/401, 43
8.2
Excitation current
120
400
¡¡


Excitation voltage
3
11
¡¡


5
198/248, 30
192/254, 37
2.76
Excitation current
100
200
500
1000

Excitation voltage
2
6
35
90

6
198/248, 20
192/254, 27
1.84
Excitation current
100
200
500
1000

Excitation voltage
1.5
3.5
25
60

7
155/200, 30
150/205, 36
2
Excitation current
100
190
1000


Excitation voltage
2.5
9.5
80


8
140/180, 30
135/185, 36
1.58
Excitation current
40
80
240


Excitation voltage
1
2.9
15


9
130/190, 30
125/195, 36
2.38
Excitation current
40
80
240


Excitation voltage
1.2
3.8
17


10
100/140, 30
95/145, 36
1.19
Excitation current
30
120
500


Excitation voltage
0.85
6.8
68


11
90/130, 30
85/135, 36
1.09
Excitation current
30
120
500


Excitation voltage
0.7
6
55


12
90/125, 25
85/130, 31
0.78
Excitation current
30
120
500


Excitation voltage
0.9
7
70


13
80/120, 30
75/125, 36
0.99
Excitation current
200
500
¡¡


Excitation voltage
20
65
¡¡


14
85/115, 30
80/120, 36
0.74
Excitation current
30
120
500


Excitation voltage
0.7
6.5
55


15
85/125, 20
80/130, 26
0.7
Excitation current
30
120
500


Excitation voltage
0.62
5.5
50.







wooden case+carton box.
GOLD Member
VERIFIED
Jan-15-20

Plate Iron Scrap

MOQ: 200  Square Yards
Supplier From Southampton, United Kingdom
 
Plate Iron Scrap is a material that a visual inspection appears of regular shape. This by-product is formed after slag processing in electrometallurgical furnaces.

Its chemical composition is homogeneous and stable with about Fe 90% and P around 1.4%, S 0.8% and C 1.4%.

The max weight of each pieces is up to 1 ton.

The material can be loaded loose in 20 heavy duty container.

For further details feel free to contact us.
GOLD Member
VERIFIED
Jul-04-03
Supplier From Navi Mumbai, Maharashtra, India
GOLD Member
Apr-30-24

Iron

MOQ: Not Specified
Supplier From Singapore, Singapore
 
We have a unique iron ore resource footprint with large, high-quality resource bases in South Africa and India. Demand for iron ore globally is largely dependent on the state of the steel industry worldwide and, more specifically, on that of the steel manufacturing sector in China. Brat supplies leading quality lump ore and also produces premium fine ore from the mines of its associate company in Goa, India.
96426 Current Transformer Iron Core Suppliers
Short on time? Let Current Transformer Iron Core sellers contact you.
GOLD Member
Sep-14-20

Pig Iron Scrap

$120
MOQ: 5000  
Sample Available
Supplier From Surat, Gujarat, India
 
I can supply you best quality pig iron scrape like, sckul, granules, plates etc per month 5000 ton
SILVER Member
Dec-29-24
Supplier From Huizhou, Guangdong, China
 
Cast Iron and Ductile Iron tube and fittings PL739

Cast Iron and Ductile Iron tube and fittings can be offered by our comapny to meet different engineering needs.

The difference between ductile iron and gray iron

1. Different chemical composition

Nodular cast iron contains nodular graphite, which can improve its toughness and strength, while reducing brittleness. Gray cast iron contains a lot of carbon, so that its hardness and wear resistance is high, but the toughness is poor.

2. Different organizational structures

The structure of nodular cast iron contains nodular and ferrite, and the distribution of nodular is uniform. While the structure of gray cast iron is mainly ferrite and pearlite, and the distribution of pearlite is uneven.

3. Different performance

Ductile iron has high strength and toughness, and has good corrosion resistance. It is uitable for the manufacture of high load and high pressure parts. The hardness and wear resistance of gray cast iron are high. It is suitable for the manufacture of friction and wear parts.

Application field
Cast iron : because of its low strength and good vibration resistance. It is often used in the production of parts under compressive stress, such as box, base, etc.
Ductile iron : because of its high strength and good toughness. It is often used in the manufacture of parts requiring high strength and toughness, such as crankshaft, connecting rod and so on.
GOLD Member
Oct-11-23

Iron Skull Boulder And Steel Skull

$125
MOQ: 100  Metric Tonnes
Supplier From Surat, Gujarat, India
 
Iron Skull Boulder and steel skull
Different size
Regular supply
May-22-20
 
KF series
split-core current transformers.
The CT can be mounted to existing panels, such
as control centers or load centers, to measure or monitor voltage. These CTs
can be mounted without removing existing cables for easily installation.
Mar-28-14
 
The initial magnetic permeability and temperature stability between nanocrystalline soft magnet alloy and permalloy are similar. Under the same conditions of core sizes and characteristics, the weight of the former is much lighter
(about 1/3 lighter), cost much lower.

Applications:
Electronic kwh meter
Precise power meter
Overcurrent protection in mechanical control apparatus
Current control in industrial automation

Good thermal stability

Paper ctn
GOLD Member
VERIFIED
Jun-28-21

Pig Iron

MOQ: Not Specified
Supplier From Faridabad, Haryana, India
 
Pig Iron for sale at high quantities from India. Payment Term - LC For price and specification.
This Pig Iron slag is a by-product derived from the production of thermal insulating products. The byproduct is a ferrous slag which can be utilised in an electric arc furnace to produce crude steel. Physical Description On visual inspection, it appears to be made up of irregular shapes. Dimension: 300mm -1000mm Chemical Composition Its chemical composition is homogeneous and stable with Fe contents in the range of 85 +/- 5% and P contents < 0.8% S around 0.15% and C% around 3.5%. Packing: Loose in container Loading: in 20 Container.
GOLD Member
Mar-01-24

Transformers

$20
MOQ: Not Specified
Supplier From Ludhiana, Punjab, India
 
Transformers,Distribution and Power Transformer,Varivolt
Safety Transformers
Diesel Generators
Industrial Panels
Stabilizers
Energy Saver
Industrial Panels
GOLD Member
Apr-06-18
Supplier From Mumbai, Maharashtra, India
 
Natural Red Iron Oxide:

Natural Red Iron Oxide is the most widely occurring Minerals in Earth. It is widely used in many applications due as it is economical as compared to Synthetic Oxides.

Applications :
Red Oxide is anti-corrosive and has inertness to alkali and chemicals which makes its very viable for making of paint, protective coating for steels, cement coloring, NPK Fertilizers, paving tiles.

Packing : 25Kgs Bags.
GOLD Member
VERIFIED
Oct-28-14
Supplier From Dubai, Dubai, United Arab Emirates
GOLD Member
Oct-28-16
Supplier From Surat, Gujarat, India
GOLD Member
Apr-30-24

Pig Iron

MOQ: Not Specified
Supplier From Singapore, Singapore
 
Pig Iron comprises three main types: Basic Pig Iron, Foundry Pig Iron and Nuclear Pig iron. We supply compositions within fairly narrow ranges of specifications with the objective of optimizing customer's costs
GOLD Member
VERIFIED
Sep-10-21

Cast Iron Skulls

$280
MOQ: 100  Tons (UK)
Supplier From Southampton, United Kingdom
 
These cast iron skulls are a by-product derived from the cast iron foundries. The byproduct is a ferrous by-product which can be utilised in an electric arc furnace to produce crude steel.

Physical Description
On visual inspection, it appears to be made up of irregular shapes.
The material is separated by magnet and screener.

Packing: Loose in container

Loading: in 20 Container

For further information, please feel free to contact us.
Nov-14-23
 
Application
Current transformers can convert large currents into small currents in a certain proportion, thereby providing current for various instruments and relay protection, and isolating the secondary system from high voltage. This way can protect workers and equipment, can also simplifies and standardizes the manufacture of meters and relays.

Advantagesï¼?
In order to improve the current transformer precision, has to improve the magnetic permeability of current transformer cores. Compared with silicon steel core, nanocrystalline core has better magnetic permeability. Compared with permalloy core, the cost of nano core is lower. So nano core is the ideal material of current transformer. It is widely used in precision current transformer, zero sequence current transformer, medium and high frequency transformer.
Nov-10-23
 
Application
Current transformers can convert large currents into small currents in a certain proportion, thereby providing current for various instruments and relay protection, and isolating the secondary system from high voltage. This way can protect workers and equipment, can also simplifies and standardizes the manufacture of meters and relays.

Advantages
In order to improve the current transformer precision, has to improve the magnetic permeability of current transformer cores. Compared with silicon steel core, nanocrystalline core has better magnetic permeability. Compared with permalloy core, the cost of nano core is lower. So nano core is the ideal material of current transformer. It is widely used in precision current transformer, zero sequence current transformer, medium and high frequency transformer.
Sep-05-17
 
Features:
High saturate magnetic induction bs
High initial permeabilityhigh linearity high accuracylow phase and amplitude error for ct
Good temperature stability-55~130
Applying for transformer class grade: 0.5-0.05 class

2applications
High precision current and voltage transformer
Current leakage circuit breakers
Electronic watt hour meter
Precision power meter
Current control in automation industry
96426 Current Transformer Iron Core Suppliers
Short on time? Let Current Transformer Iron Core sellers contact you.