Please click here to check who's online and chat with them.

Find Verified Electric Contactors Suppliers, Manufacturers and Wholesalers

Top Supplier Cities : Shenzhen   Guangzhou   -  
VERIFIED
Sep-19-22
 Inquire Now  
* 200 Amps Normally Open 24VDC with auxiliary switch
* Double coils
* Customized available
Apr-25-14
 Inquire Now  
Part NO Coil Voltage 50/60HzNumber of PolesFull Load (A)Maximum Voltage
25 FLA -2 Pole
QCA-25224225120
QCB-252120240
QCC-252208/240
30 FLA-2 Pole
QCA-30224230120
QCB-302120240
QCC-302208/240
40 FLA-2 Pole
QCA-40224240120
QCB-402120240
QCC-402208/240
May-05-06
Supplier From Yueqing, Zhejiang, China
 Inquire Now
Oct-06-09
Supplier From Wenzhou, China
 Inquire Now
Sep-10-07
Supplier From Guiyang, Guizhou, China
 Inquire Now
166 Electric Contactors Suppliers
Short on time? Let Electric Contactors sellers contact you.
Feb-13-09
Supplier From Yangzhong, China
 Inquire Now
Aug-03-11
Supplier From Yueqing, China
 Inquire Now
Jul-28-18
Supplier From Shanghai, China
 Inquire Now
Jul-12-17
Supplier From Wenzhou, Zhejiang, China
 Inquire Now
Feb-03-09
Supplier From Kunming, China
 Inquire Now
May-21-22
Supplier From Huizhou, Guangdong, China
 Inquire Now  
Electromagnetic contactor (contactor) refers to an electrical appliance that uses the current flowing through the coil to generate a magnetic field in industrial electricity to close the contact so as to control the load. The contactor is composed of electromagnetic system (armature, stator core, electromagnetic coil), contact system (normally open contact and normally closed contact) and arc extinguishing device.
Structural composition
Electromagnetic contactor is mainly composed of transmission device (electromagnetic mechanism), contact device (actuator) and arc extinguishing device.


1. Electromagnetic mechanism


The electromagnetic mechanism includes three parts: moving core (armature), static core and electromagnetic coil. The electromagnetic coil is connected with current to generate electromagnetic suction and drive the contact to act.


Electromagnetic mechanism is one of the important parts of electromagnetic contactor. The electromagnetic mechanism is composed of coil, iron core (static iron core), armature (moving iron core), pole shoe, iron yoke and air gap. The coil and iron core in the electromagnetic mechanism do not move in the working state; The armature is movable.


The electromagnetic mechanism converts the electromagnetic energy generated by the electromagnetic coil into mechanical energy through the action state and action process of the armature and the corresponding mechanical mechanism to drive the contact to close or open, so as to realize the control purpose of the controlled circuit.
May-21-22
Supplier From Huizhou, Guangdong, China
 Inquire Now  
Contactors are divided into AC contactors (voltage AC) and DC contactors (voltage DC), which are used in power, power distribution and power consumption. Broadly speaking, contactor refers to an electrical appliance that uses the current flowing through the coil to generate a magnetic field and close the contact in order to control the load.
main features
The AC contactor uses the main contact to open and close the circuit and the auxiliary contact to turn on the control circuit.


The main contact is generally normally open contact, while the auxiliary contact often has two pairs of normally open contact and normally closed contact. Small contactors are often used as intermediate relays to cooperate with the main circuit.


The contact of AC contactor is made of silver tungsten alloy, which has good conductivity and high temperature ablation resistance.


The power of AC contactor action comes from the magnetic field generated by AC through the coil with iron core. The electromagnet core is composed of two "mountain" shaped young silicon steel sheets. One of the fixed iron core is sleeved with coil, and the working voltage can be selected. In order to stabilize the magnetic force, a short-circuit ring is added to the suction surface of the iron core. After the AC contactor loses power, it returns by spring.


The other half is a movable iron core, whose structure is the same as that of a fixed iron core, which is used to drive the closing and breaking of the main contact and auxiliary contact.
Dec-13-20

Ac Contactor

$10 - $1.00K
MOQ: Not Specified
 Inquire Now  
Overview

The AF Series 1-stack 3-pole contactors are of the block type design. Main poles and auxiliary contact blocks: 3 main poles, 1 built-in auxiliary contact, front and side-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) - Control circuit: AC or DC operated - Accessories: a wide range of accessories is available



UA16-30-10 RA UA26-30-10 AF9-30-10 AF1250-30-11
UA16-30-10 RA UA26-30-10 AF12-30-10 AF1350-30-11
UA16-30-10 RA UA26-30-10 AF16-30-10 AF1650-30-11
UA16-30-10 RA UA26-30-10 AF26-30-11 AF2050-30-11
UA26-30-10 RA UA30-30-10 AF30-30-11 AF2650-30-11
UA26-30-10 RA UA30-30-10 AF40-30-11 A9-30-11
UA26-30-10 RA UA30-30-10 AF50-30-11 A12-30-11
UA26-30-10 RA UA30-30-10 AF63-30-11 A16-30-11
UA30-30-10 RA UA50-30-00 AF75-30-11 A26-30-11
UA30-30-10 RA UA50-30-00 AF95-30-11 A30-30-11
UA30-30-10 RA UA50-30-00 AF110-30-11 A40-30-11
UA30-30-10 RA UA50-30-00 AF116-30-11 A50-30-11
UA50-30-00 RA UA63-30-00 AF140-30-11 A63-30-11
UA50-30-00 RA UA63-30-00 AF145-30-11 A75-30-11
UA50-30-00 RA UA63-30-00 AF146-30-11 A95-30-11
UA50-30-00 RA UA63-30-00 AF185-30-11 A110-30-11
UA63-30-00 RA UA75-30-00 AF205-30-11 A145-30-11
UA63-30-00 RA UA75-30-00 AF210-30-11 A185-30-11
UA63-30-00 RA UA75-30-00 AF260-30-11 A210-30-11
UA63-30-00 RA UA75-30-00 AF265-30-11 A260-30-11
UA75-30-00 RA UA95-30-11 AF300-30-11 A300-30-11
UA75-30-00 RA UA95-30-11 AF305-30-11 A320-30-11
UA75-30-00 RA UA95-30-11 AF370-30-11 AF460-30-11
UA75-30-00 RA UA95-30-11 AF400-30-11 AF580-30-11
UA110-30-11 UA110-30-11 UA110-30-11 AF750-30-11
UA110-30-11 UA110-30-11 UA110-30-11
Aug-27-19
 Inquire Now  
4P 60kA AC surge protector

This surge protective device( hereinafter referred to as SPD) are suitable for AC 50/60Hz, rated voltage up to 380v IT,TT,TN-C, TN-S,TN-C-S and other power supply system,  it protect to indirect and direct lightning effect or other transient over voltage 


SPD design according with GB18802.1/IEC61643-1 standard.

Specification details:
Model PQ1-60
Poles 4P
Max. continious working voltage(Uc) 420V AC(can customized)
Nominal discharge current(In) 30kA
Max.discharge current(In) 60kA
Voltage protection level(Up) 2.0kV
Matched circuit breaker/Fuse 32A
Response time
Aug-27-19
 Inquire Now  
2P 80kA AC surge protector

This surge protective device( hereinafter referred to as SPD) are suitable for AC 50/60Hz, rated voltage up to 380v IT,TT,TN-C, TN-S,TN-C-S and other power supply system,  it protect to indirect and direct lightning effect or other transient over voltage 


SPD design according with GB18802.1/IEC61643-1 standard.

Specification details:
Model PQ1-80
Poles 2P
Max. continious working voltage(Uc) 420V AC(can customized)
Nominal discharge current(In) 40kA
Max.discharge current(In) 80kA
Voltage protection level(Up) 2.5kV
Matched circuit breaker/Fuse 32A
Response time
Jun-27-19

Schneider Tesys D Contactor Lc1D12Bl

$100
MOQ: Not Specified
Supplier From Shenzhen, China
 Inquire Now  
Main

Range : TeSys

Product name : TeSys D

Product or component type : Contactor

Device short name : LC1D

Contactor application : Motor control
Resistive load

Utilisation category : AC-3
AC-1
AC-4

Poles description : 3P

Pole contact composition : 3 NO

[Ue] rated operational voltage :
Jun-27-19

Schneider Tesys D Contactor Lc1D12G7

$100
MOQ: Not Specified
Supplier From Shenzhen, China
 Inquire Now  
Main

Range : TeSys

Product name : TeSys D

Product or component type : Contactor

Device short name : LC1D

Contactor application : Motor control
Resistive load

Utilisation category : AC-3
AC-4
AC-1

Poles description : 3P

Pole contact composition : 3 NO

[Ue] rated operational voltage :
Oct-26-15

Contactor

MOQ: Not Specified
 Inquire Now  
Siemens, merlin gerin, abb, westinghouse, honeywell, ge, schneider, allen bradley, moeller, aeg, fuji, furnas, albright, lovato, benshaw, hager, l&t, brook, chint, danfoss, omron, teco, sprecher, stromberg, togami, joslyn clark, eaton, matsushita.
Specific contactors, low voltage contactor, magnetic contactors, solid-state contactor, definite purpose contactors, modular contactor, low noise contactor, miniature contactor, standard contactor, contactors for special applications
May-14-09
 Inquire Now  
GSC1 series AC Contactors are used in the circuit of 50Hz or 60Hz frequency with rated current up to 95A under usage category AC-3 at 380V AC. These AC contactors comply with IEC60947-4:

Rated Isolation Voltage: up to AC690V

Rated Voltage: 220V AC or 380V AC or 415V AC or 440V AC or 660V AC

Rated Current under usage category AC-3 at 380V AC (A) : 9A, 12A, 18A, 25A, 32A, 38A, 40A, 50A, 65A, 80A, 95A

Rated Thermal Current (A): 25, 25, 32, 40, 50, 50, 60, 80, 80, 125, 125

Controlled Load Power at 380V AC (KW): 4, 5.5, 7.5, 11, 15, 18.5, 18.5, 22, 30, 37, 45

Electrical Life (104) under usage category AC-3: from 60 to 100

Operation Frequency under usage category AC-3 (times per hour): from 300 to 1000

Mechanical Life (104): from 600 to 1000

Contact number: 3P+NO or 3P+NC, 3P+NO+NC if Rated current being over 38A.

Frequency: 50Hz or 60Hz

Coil Voltage: AC24V or AC48V or AC110V or AC220V or AC380V.

Contact: 90% Silver and 10% Ni or 88% Sliver and 12% Cadmium Oxide.
Jan-12-09
 Inquire Now  
Changeover switch

We supply circuit breaker, meters, stabilizer, switch, relay, contactor, lamps

Strong export carton
166 Electric Contactors Suppliers
Short on time? Let Electric Contactors sellers contact you.
See what buyers and suppliers are discussing in Electric Contactors import export community