The Athenalarm AT-805 is a wired indoor PIR (Passive Infrared) motion sensor for conventional intrusion alarm systems. It uses a dual-element pyroelectric infrared sensor with Fresnel lens optics, true temperature compensation, 3-level adjustable pulse counting, and anti-RF interference protection (20V/m, 10MHzâ??1GHz). It delivers a 12m detection range, 110° detection angle, selectable NO/NC alarm output, and a dedicated NC tamper output.
Suitable for residential, office, retail, warehouse and factory security. Available for wholesale, bulk order, and OEM/private label (MOQ 100pcs, 5-day lead time, 1-year warranty).
Key Specifications
Parameter Specification
Model AT-805
Type Wired indoor PIR motion sensor
Sensor Dual-element pyroelectric infrared
Optics Fresnel lens
Detection Range 12 m
Detection Angle 110°
Operating Voltage DC 9â??16 V
Quiescent Current â?¤18 mA @ DC 12V
Alarm Output NO/NC selectable, DC28V/100mA
Tamper Output NC, DC28V/100mA
Temperature Compensation True temperature compensation
Pulse Counting 3 selectable levels
RF Interference Immunity 20 V/m, 10MHzâ??1GHz
Operating Temperature -10°C to +50°C
Humidity â?¤95% RH, non-condensing
Installation Wall/corner, height 1.7â??2.5m
Self-Test Time ~60 seconds
Dimensions 83 Ã? 90 Ã? 110 mm
Manufacturing SMT
Warranty 1 year
Key Features
12m/110° dual-element PIR coverage with Fresnel optics for reliable indoor detection
True temperature compensation â?? stable performance under changing ambient temperature
3-level adjustable pulse counting â?? balance sensitivity vs. RF-interference resistance per site
Anti-RF & anti-white-light interference, tested to 20V/m (10MHzâ??1GHz)
Selectable NO/NC alarm output â?? compatible with most conventional alarm panels
Independent NC tamper output for enclosure protection
Wall or corner mount, SMT-manufactured for consistent quality control
Low MOQ (100pcs), 5-day lead time, OEM/private label available
Installation Guidelines
Mount on wall (height 1.7â??2.5m) or corner; surface must be solid and vibration-free
Position so intruders cross the detection field rather than walk directly toward the sensor
Avoid: outdoor use, direct sunlight, HVAC vents, heat sources, rotating fans, unstable surfaces, or areas with pets
After power-up, allow ~60s self-test, then perform a walking test to confirm alarm response before commissioning
Recommended: weekly walking test for ongoing system verification
Applications
Residential (homes, villas) · Commercial (offices, retail, malls) · Industrial (factories, warehouses, storage) · Conventional wired alarm system integration projects