Please click here to check who's online and chat with them.

Find Verified Scientific Instruments Suppliers, Manufacturers and Wholesalers

Feb-02-21
 
GFUVE 2-63th THD class 0.5S Modbus RS485 LCD display AC power quality analyzer meter



FU2200A digital Ethernet power meter with data logger is a three-phase multifunction power and energy meter manufactured by GFUVE. It provides excellent value for monitoring power and energy management systems. It may be used as data gathering devices for intelligent power distribution or plant automation systems. All monitored data is available via a standard digital RS485 communication port, which is based on the Modbus RTU protocol.

FU2200A Ethernet power meter has the PC software and the data logger function, which can set by end users from 1min to 60min intervals to record. You can read the data through a PC. Also, you can share the data in the Internet LAN. By the way, it can measure the harmonics. Back of power meter FU2200A with Etherne
Dec-11-20

Travelling Microscope

$85
MOQ: Not Specified
Supplier From Ambala Cantt, Haryana, India
 
With horizontal and vertical scales. The bed is of cast iron and accurately machined. The horizontal carriage is machined and inters ground on the guide ways of the horizontal bed. The carriage is fitted with vertical brass pillar carrying a microscope tube on a ground fitted vertical carriage. The base is fitting with two leveling screws Horizontal scale is 20cms and vertical 15cms. Long. Both the horizontal scale and vertical carriages are provided with slow motions, which travels app. 3cms in one traverse. Microscope tube is provided with rack & pinion. A milk white Perspex platform is provided on the horizontal bed. Vernier constant 0.001cms. Complete in well-polished wooden case. Having stainless steel scale.
Aug-25-20
 
It is mainly used for field testing of P class CT and PT. The test items mainly include excitation characteristic, transformation ratio, polarity, degauss, 5% and 10% error curves, secondary circuit check, withstand test of power frequency alternating current and secondary load. Adopting LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to dump data, with simple and convenient operation.
May-09-19
 
Please check it with E-mail: sales8@amikon.cn we will response you in 24 hours!

Quick Details
Delivery Time: 3-5 DAYS
Packing: NEW CARTONS
Delivery Port:XIAMEN

Automation technology is widely used in industry, agriculture, military, scientific research, transportation, commerce, medical, service and family. The adoption of automation technology can not only liberate people from heavy manual labor, partial mental labor and harsh and dangerous working environment, but also expand the function of human organs, greatly improve labor productivity, and enhance the ability of human beings to understand and change the world.

We have lots of models:
TC-FCCN01 TC-FCCR01 TC-FFC010 TC-FFC025
TC-FFC050 TC-FFC100 TC-FFIF01 TC-FFPCX1
TC-FFRP02 TC-FFRU01 TC-FIAH81 TC-FID161
TC-FIDA81 TC-FIL081 TC-FIR081 TC-FOA041

Applied Materials (AMAT) 0140-04657 CABLE ASSEMBLY, SYSTEM CONNECTION, AT IN
Applied Materials (AMAT) 0140-04806 HARNESS ASSY, MF AC TO NSK POWER, 300MM
Applied Materials (AMAT) 0140-06842 HARNESS ASSY HEATER CTRLR/SSR 300MM WET
Applied Materials (AMAT) 0140-12587 HARNESS ASSY, FI SW LONG EXTEN, AMBIENT
Applied Materials (AMAT) 0140-35496 HARNESS ASSY
Applied Materials (AMAT) 0140-77347 HARN, AC POWER ON-TRACK
Applied Materials (AMAT) 0140-90687 CABLE 2GJ9/3DJ23
Applied Materials (AMAT) 0150-01066 CABLE ASSY., DNET JUMPER BOX, ON BOARD D
Please note that here is only part of the model, if you have the need, please contact us.

Skype : dddemi33
Sales Manager : Tiffany Guan
RFQ e-mail : sales8@amikon.cn
Whats@app : +86 18030235313
QQ :2851195473

Packing & Delivery

1)100% full New! - Original Factory Seal !
2)Warranty: 12 months!
3)Package: Original packing with cartons.
4)Delivery time: Shipped in 3 days after payment
5)ship to you via DHL/TNT/UPS/EMS/Fedex.
6) All the goods will be tested before shipment
7) Payment: T/T100% Payment in Advance


We give a quick response for the customer demand.The partner network spans across continents.We offer more professional industrial automation spare parts services.we are waiting for you!

Skype : dddemi33
Sales Manager : Tiffany Guan
RFQ e-mail : sales8@amikon.cn
Whats@app : +86 18030235313
QQ :2851195473
Feb-13-19
 
FunctionGeneral resistivity/IP soundingMulti-electrode 2D/3D resistivity imagingMulti-electrode 2D IP imagingRock sample testWork as receiver in large power IP systemApplicationsUnderground water inspectionEnergy resource prospectingCity geophysical explorationRailway and bridge inspecting Metal and nonmetal mineral resources surveyEngineering geologyGeothermal field survey.SpecificationsGeophysical instruments and ground water detection equipmentReceiving part:voltage channel: ±32V24 bitA/Daccuracy: as Vp5mV, ±0.2% ±1 character as 0.1mVVp5mV, ±1% ±1 character Input impedance: 50© Apparent polarization accuracy: ±1±1character SP compensation range: ±10V Current channel: 6A24bitA/Dmeasurement accuracy: as Ip5mA, ±0.2% ±1character as 0.1mAIp5mA, ±1% ±1character As for 50Hz industrial interfacecommon and different modedepression is better than 80dBTransmitter partmaximium power: 7200Wmaximium supply voltage: ±1200Vmaximium supply current: ±6Asupply current width :160s, duty rate 1:1
1998 Scientific Instruments Suppliers
Short on time? Let Scientific Instruments sellers contact you.
Feb-13-19
 
Technical specificationsReceiving partvoltage channel: ±32V24 bitA/D)accuracy: as Vp5mV, ±0.2% ±1 character as 0.1mV?¤Vp5mV, ±1% ±1 characterInput impedance: 50©Apparent polarization accuracy: ±1±1characterSP compensation range: ±10VCurrent channel: 6A24bitA/DTransmitter partmaximium power: 7200Wmaximium supply voltage: ±1200Vmaximium supply current: ±6ADeep geophysical equipment groundwater detector 1D IP sounding:ID AB/2(M)MN/2(M) K11.50.512.56637122.50.523.56194533.50.537.69911244.50.554.97787155.50.540.5678
Feb-13-19
 
Technical specifications:Receiving partVoltage channel: ±32V24 bitA/DAccuracy: as Vp5mV, ±0.2% ±1 character as 0.1mVVp5mV, ±1% ±1 character Input impedance: 50 Apparent polarization accuracy: ±1±1character SP compensation range: ±10V Current channel: 6A24bitA/DMeasurement accuracy: as Ip5mA, ±0.2% ±1character as 0.1mA?¤Ip5mA, ±1% ±1character As for 50Hz industrial interfacecommon and different modedepression is better than 80dBTransmitter part:Maximium power: 7200W Maximium supply voltage: ±1200V Maximium supply current: ±6A Supply current width :160s, duty rate 1:1OtherWorking temperature: -10+50,95RH Storge temperature: -20 +60 Power supply: builtin 7.4V4Ahor outside 12V, lasting for 20h Main unit port: A, B, M, N, DC high voltage, outside battery, 2 cable port, RS-232, blue tooth Weight: 4kg Size : 270mm246mm123mm
Feb-13-19
 
FeaturesPortability and flexibilitycombining transmitter and receiver together, small and light. Real one machine and multi-functionvoltage and current range and small signal accuracy improved greatly, it is fitted for rock sampling tester, large-power IP receiver, nomal resistivity tool, IP, water finder, 2D and 3D high-density electrical tool etc.. Multi-parameter measurement, wide applicationvoltage, current, apparent resitivity, SP, apparent chargability, metal factor, half life, attenuation, IP ratio, departure, IP spectrum. Blue technique, wireless remote controlPocket PC controlled central unit by Bluetooth technique, remote control is effective within 10 m. All parameters and measurement display can be fulfilled easily wirelessly. Pocket PC control, Powerful functionall Chinese pocket PC support the man machine interface and sampling control, parameters setting, data display and storge, graph plot, image making, Field works are very easy.Extendable easilydata sampling and storage are all controlled by pocket PC. Data management is easy and software is easy to be extended. Powerful pocket PCbeside the high hardware configuration, pocket PC is installed with many utility software. User can arrange the date, navigate the web via wireless net, and use WORD, EXCEL, PowerPoint, and Media Player for office and amusement. With double high-density resistivity cable port, cross-hole resistivity can be carried out without medium switcher. Measurement is concise and easy. Super wide range, high accuracyvoltage is as high as 64Vp-p, small signal measurement accuracy is high voltage is less than 0.1mV and current is less 0.1mA with ±1% accuracyï¼?. Tool is fitted for high resistivity region; high-density can achieve good results. Complete anti-interface techniqueuse multi-stage filter and signal enhancement technique, integrate anti-interface funation, accuracy is high. Auto SP, shift and electrode compensation with range as high as ±10V. The panel has "infinite"pole for pole-pole and dipole-pole measurement. During dipole-pole measurement, sA,sB, and s can be measured automatically with high efficiency.Receiver has over-voltage over- current and AB open protection ability. Ground resitivity checkAB pole and MN pole can be checked at any time, easy and practically. Dignosis program can find the trouble with the tool quickly and accurately. Imported air proof box is water-proof, dust-proof, and long life. Flexiable control choicethe tool can be controlled with note PC for field work.
Oct-31-18
Supplier From Dongguan, Guangdong, China
 
Single Color DIP
8mm Round With Edge
Visible DIP, 5mm Round with Flange, 5mm Flat with Flange For Sale
Y.LIN can supply top view PLCC SMD, side view chip SMD and top view chip LED, etc. We are a leading enterprise in China, is a high-tech company, which manufactures LED products.
IR LED Emmiter, IR LED Receiver, Digit Tube Display, Infrared interrupter, Digit Display LED Dot Matrix, Single Color DIP Supplier.
Oct-17-18
 
Lsp-1500 lab scale spray dryer can produce a dry powder from a liquid or slurry by rapidly drying with a hot gas.
Lsp-1500 has successfully processed samples in the following areas: beverage, flavours and colourings, milk and egg products, plant and vegetable extracts, pharmaceuticals, synthetics heat sensitive materials, plastics polymers and resins, perfumes, blood, ceramics and superconductors biochemicals, dyestuffs, soaps and detergents, foodstuffs, adehesives, oxides, textiles, bones, teeth and tooth amalgam and many others.
Oct-03-18
 
Hawach Scientific special produces and supplies prepacked and empty HPLC Column to the global market and stationary phase with full range of material available such as C18 Universal, C18 low PH, C18 Aqueous, C8 Universal, C8 low PH, C8 Aqueous, C8-Fluorine, Phenyl, NH2, CN, Diol, SiO2, Polar-RP etc. Our HPLC column with high column efficiency and excellent shape peaks and low pressure for a longer lifetime, especially the C18 Universal column which equivalent to brands like Waters, Agilent, and GL Science.
Oct-03-18
 
The pipette is a precision instrument that removes a small amount of liquid. Our other related products include pipette stand and pipette tips. Pipettes include electronic pipette and mechanical pipette, pipette stand include linear stand and round stand. Pipette tips are divided into advanced pipette tips, standard pipettes, and advanced filter pipette tips. All our products guarantee the high accuracy, easy operation and are the best choice for customers.
Oct-03-18
 
Hawach extraction thimbles are available in cellulose extraction thimbles or glass extraction thimbles. Cellulose extraction thimbles are always used in general Soxhlet extraction, such as indoor dust, indoor toxic organic removal. Glass extraction thimbles are suitable for situations where cellulose extraction thimbles are not suitable, such as temperatures above 120 degrees Celsius and strong acids. Glass extraction thimbles are commonly used for the detection of stationary sources such as cadmium, nickel, tin, etc. in smoke, and smoke lead.
Oct-03-18
 
Hawach Scientific Co., Ltd QuEChERS is a sample treating method, which means quick, easy, cheap, effective, rugged and safe. Our products include four types which are QuEChERS kit, QuEChERS extraction salts, QuEChERS dispersive SPE kit, QuEChERS dispersive absorbent, QuEChERS ceramic homogenizers. The standard methods applicable to our products include AOAC Official 2007.01 Method and European EN 15662 Method.
Aug-08-18
 
I. Introduction
SS-600C Hot & Wet Waste Incineration CEMS System developed and produced by Senshang Instruments is to monitor the total air pollutant emissions from stationary sources in waste incineration power plant, to measure SO2, NO, NO2, CO, CO2, HCL, NH3, O2 and H2O, as well as simultaneously to measure particles content, gas flow, gas pressure, gas temperature and so on. The hot-wet sampling system: All components (probe, sample line, pump and analyzer sample cell) in contact with the gas stream are maintained above the dew point of the flue gas to prevent condensation of reactive vapors. This approach does not incorporate a gas cooler. The Hot-Wet sampling approach results in a simple and reliable sampling system with high availability.

CEMS consists of
1Gas analysis monitoring system.
2Particles monitoring system.
3Gas temperature/pressure/velocity measurement
4Data Analysis System.

II. Application fields
It is widely applied to the monitoring of flue gas emissions in ultra-low emission field, thermal power plant, industrial kiln / boiler, cement industry, petroleum industry, waste incineration power generation, hazardous waste incineration and other industries.

III. Specifications
Measurement items Ranges(can be customized)
SO2 0-150-750mg/m3
NO 0-200-1000mg/m3
CO 0-500-2500mg/m3
CO2 0-20%vol-40%vol
NH3 0-20-100mg/m3
HCL 0-100-500mg/m3
H2O 0-20%vol-40%vol
O2 0-5%vol-25%vol
Zero drift ±2%F.S./7d
Span drift ±2%F.S./7d
Linearity error ±1%F.S.
Response time 200s
Repeatability 0.5%
Resolution 0.005mg/m3
Temperature 0-300
Temperature accuracy ±0.5%F.S.
Pressure -5-5KPa(relative)
Pressure accuracy ±0.5%F.S.
Gas flow 0-30m/s
Velocity accuracy ±0.5%F.S.
Particles 0-5-25mg/Nm3
Particle max error ±1.5%F.S./7d
Particle zero drift ±1.5%F.S./7d
Particle span drift ±1.5%F.S.

IV. Product feature
1.Maximum 8 gas components measurement, able to measure O2 and H2O(humidity).
2.System cabinet modular design, simple operation, less maintenance.
3.Hot & Wet sampling system, no gas condensation, little SO2 and other gases loss.
4.Adopt ultra-low dust monitor to measure particles.
5.Adopt temp/pressure/velocity all-in-one instrument to measure gas T/P/F.
6.The stability and reliability of the system are higher by PLC design.
7.With anti-corrosive material.
8.With auto purging function.
Aug-08-18
 
I. Introduction
SS-300-HF Extractive Laser Analysis System adopts TDLAS Tunable diode laser absorption spectroscope to measure HF concentration. It adopts special heated sampling probe which is able to work in high-temperature and high dust conditions, and hot & wet sampling system with little gas loss caused by gas condensing. Compare in-situ type gas analyzer, the extractive system has the advantages of no requirement of installation conditions, easy maintenance, little pollution to mirror, suitable for dirty sampling point with high dust.

II. Applications field
It is used for online monitoring of organic waste gas emissions and organic waste gas recovery for chemical, printing, pharmaceutical, rubber, spray coating, electronic semiconductors, synthetic leather and so on.

III. Specifications
Monitoring place Gas component Measurement range
aluminum oxide outlet HF 0-20ppm(can be customize)
1.Measurement principleTDLAS
2.Sampling methodHot & Wet extractive sampling
3.Sampling pipe materialSUS316
4.Heated tube diameter: ,¸8,?6
5.Power supply AC220V±10%50/60Hz
6.Power consumptionMax 2000W+50W*heated tube length
7.Calibration periodeach 6 months
8.Analogue output4 - 20mA
9.Max load550Ω
10.Alarm outputgas temperature alarm, gas low pressure, gas over pressure alarm.

IV. Features
1.Extractive sampling method
2.Easy calibration and calibration
3.Adopts TLDAS principle, little cross-sensitivity,
4.Laser detector with long lifespan
5.Optional sampling probe calibration function.
6.IP 65 protection class.
7.Adopts hot and wet sampling and gas pretreatment with temperature 190â??, preventing HCL gas loss by condensation.
8.Sampling probe with purging function.
9.With lens blow up function, to prevent it dewing.
Aug-08-18
 
I. Introduction
SS-300-HCL Extractive Laser Analysis System adopts TDLAS Tunable diode laser absorption spectroscope to measure HF concentration. It adopts special heated sampling probe which is able to work in high-temperature and high dust conditions, and hot & wet sampling system with little gas loss caused by gas condensing. Compare in-situ type gas analyzer, the extractive system has the advantages of no requirement of installation conditions, easy maintenance, little pollution to mirror, suitable for dirty sampling point with high dust.

II. Applications field
It is used for stack outlet in the waste incineration power plant.

III. Specifications
Monitoring place Gas component Measurement range
Waste incineration stack outlet HCL 0-20ppm(can be customize)
1.Measurement principleTDLAS
2.Sampling methodHot & Wet extractive sampling
3.Sampling pipe materialSUS316
4.Heated tube diameter: 86
5.Power supply AC220V±10%50/60Hz
6.Power consumptionMax 2000W+50W*heated tube length
7.Calibration periodeach 6 months
8.Analogue output4 - 20mA
9.Max load4 - 20mA 550©
10.Alarm outputgas temperature alarm, gas low pressure, gas over pressure alarm.

IV. Features
1.Extractive sampling method
2.Easy calibration and calibration
3.Adopts TLDAS principle, little cross-sensitivity,
4.Laser detector with long lifespan
5.Optional sampling probe calibration function.
6.IP 65 protection class.
7.Adopts hot and wet sampling and gas pretreatment with temperature 190, preventing HCL gas loss by condensation.
8.Sampling probe with purging function.
With lens blow up function, to prevent it dewing.
Aug-08-18
 
I. Introduction
SS-300-NH3 Extractive Laser Analysis System adopts TDLAS Tunable diode laser absorption spectroscope to measure HF concentration. It adopts special heated sampling probe which is able to work in high-temperature and high dust conditions, and hot & wet sampling system with little gas loss caused by gas condensing. Compare in-situ type gas analyzer, the extractive system has the advantages of no requirement of installation conditions, easy maintenance, little pollution to mirror, suitable for dirty sampling point with high dust.

II. Applications field
It is used to monitor NH3 after SNR or SCNR process in the waste incineration plant, power plant and so on.

III. Specifications
Monitoring place Gas component Measurement range
SNR or SCNR stack outlet NH3 0-20ppm(can be customize)
1.Measurement principleTDLAS
2.Sampling methodHot & Wet extractive sampling
3.Sampling pipe materialSUS316
4.Heated tube diameter: ø8�6
5.Power supply AC220V±10%50/60Hz
6.Power consumptionMax 2000W+50W*heated tube length
7.Calibration periodeach 6 months
8.Analogue output4 - 20mA
9.Max load4 - 20mA 550©
10.Alarm outputgas temperature alarm, gas low pressure, gas over pressure alarm.

IV. Features
1.Extractive sampling method
2.Easy calibration and calibration
3.Adopts TLDAS principle, little cross-sensitivity,
4.Laser detector with long lifespan
5.Optional sampling probe calibration function.
6.IP 65 protection class.
7.Adopts hot and wet sampling and gas pretreatment with temperature 190, preventing HCL gas loss by condensation.
8.Sampling probe with purging function.
9.With lens blow up function, to prevent it dewing.
Aug-08-18
 
I. Introduction
The SS-700 process VOCs monitoring system is based on the standards of HJ/T80, HJ/T75, HJ/T76 and other related standards, sampling by extraction method, configuration based on advanced gas chromatography, mass spectrometry separation technologies and hydrogen flame Ionization Detectors (FID), photoionization detectors (PID) to measure the composition of volatile organic gases such as total hydrocarbons (THC), non-methane total hydrocarbons (NMHC), aromatic hydrocarbons, esters, etc. According to the composition and detection requirements in the analysis project, it can be configured to meet the requirements of the analysis project and the frequency of analysis. At the same time, the optimization of instrument configuration can be performed to maximize the use of the instrument and ensure the continuity of sample analysis. reliability.

The analysis system fully considers sample gas conditions, dew point and other factors, and specifically designs the pretreatment system to prevent the crystallization of components in sample gas from condensing and changing the concentration of components.

The instrument uses special column combination, center cutting and back blowing technology and hydrogen flame ionization detector (FID) technology for detection. The FID Hydrogen Flame Ionization Detector is a typical mass detector that measures the mass change rate of a component in a GC gas. The response value is proportional to the mass of a component entering the detector per unit of time.

II. Features
1.The system piping is imported clean stainless steel pipe to reduce adsorption;
2.The system adopts full calibration to eliminate the influence of a small amount of adsorption on the measurement.
3.The analytical method is consistent with the calibration method, and it is detected by GC-FID method.
4.The whole process of high-temperature 180 °C with hot sample transmission, high temperature FID detection, to avoid high-boiling VOCs adsorption and condensation, more accurate measurement;
5.Continuously run maintenance-free design, start-up automatic cycle operation, real online analysis;
6.The whole flow path insulation design is 180°C, no water vapor condensation, to avoid corrosion degradation of parts, suitable for high temperature / high humidity / corrosive conditions;
7.Non-methane total hydrocarbons and simultaneous monitoring of benzene, toluene, xylene and other components

III. Application fields
It is used for on-line monitoring of organized organic waste gas emissions from chemical, printing, pharmaceutical, rubber, spray coating, electronic semiconductor, synthetic leather, organic waste gas recovery.
Aug-08-18
 
I. Introduction
SS-2000-HG mercury emission monitoring system for flue gas is a combination of the world's advanced online analytical technology and China's environmental protection monitoring technology. It is based on the company's many years of accumulated experience in the field of gas analysis and adopts multi optical path UV atomic absorption method. The system consists of a sampling unit with heat trace, a valence converter, and an analysis and processing unit. It can realize continuous on-line automatic and accurate measurement of mercury from fixed sources of flue gas. The system uses Cold Vapor Atomic Absorption Spectrometry (CVAAS), which is the most mature and stable analytical method among many mercury analysis methods. This method can only analyze the elemental mercury (Hg0) in the vapor state. CVAAS is based on the principle of selective absorption of ultraviolet light with a wavelength of 253.7 nm using mercury vapor. The low-pressure mercury lamp emits ultraviolet light through a gas chamber filled with sample gas and directly monitors the transmitted light intensity with an optoelectronic receiver to calculate the absorbance. Within a certain concentration range, the mercury concentration is proportional to the absorbance, which is in accordance with Beer-Lambert law. At the same time, oxygen, temperature, pressure, flow rate, humidity and other parameters can be monitored. Charts are generated through the data acquisition and processing system, and data remote transmission interfaces are reserved. The monitoring data can be transmitted to all levels of environmental protection according to the HJ/T212 national standard communication protocol. department.

II. Specifications
1. Detection method: Cold Vapor Atomic Absorption (CVAAS)
2. Measurement range: 0-100g/m3, 0-500g/m3
3, detection limit: 0.05g/m3
4, response time T90:
1998 Scientific Instruments Suppliers
Short on time? Let Scientific Instruments sellers contact you.
See what buyers and suppliers are discussing in Scientific Instruments import export community