I. Introduction
SS-300-NH3 Extractive Laser Analysis System adopts TDLAS Tunable diode laser absorption spectroscope to measure HF concentration. It adopts special heated sampling probe which is able to work in high-temperature and high dust conditions, and hot & wet sampling system with little gas loss caused by gas condensing. Compare in-situ type gas analyzer, the extractive system has the advantages of no requirement of installation conditions, easy maintenance, little pollution to mirror, suitable for dirty sampling point with high dust.
II. Applications field
It is used to monitor NH3 after SNR or SCNR process in the waste incineration plant, power plant and so on.
III. Specifications
Monitoring place Gas component Measurement range
SNR or SCNR stack outlet NH3 0-20ppm(can be customize)
1.Measurement principleTDLAS
2.Sampling methodHot & Wet extractive sampling
3.Sampling pipe materialSUS316
4.Heated tube diameter: ø8�6
5.Power supply AC220V±10%50/60Hz
6.Power consumptionMax 2000W+50W*heated tube length
7.Calibration periodeach 6 months
8.Analogue output4 - 20mA
9.Max load4 - 20mA 550©
10.Alarm outputgas temperature alarm, gas low pressure, gas over pressure alarm.
IV. Features
1.Extractive sampling method
2.Easy calibration and calibration
3.Adopts TLDAS principle, little cross-sensitivity,
4.Laser detector with long lifespan
5.Optional sampling probe calibration function.
6.IP 65 protection class.
7.Adopts hot and wet sampling and gas pretreatment with temperature 190, preventing HCL gas loss by condensation.
8.Sampling probe with purging function.
9.With lens blow up function, to prevent it dewing.
Supplier: Rubber cow mat, gymnasium mat, sport mat, ear tag, animal ear tag, tag with print, metal tag, nursery tag, horticulture tag, tag applicator, chaff cutter, milking machine, milk can, rubber milk liner, spares of milking machine, animal lifting crate, cow belt, grooming brush, water bawl, rubber feeding bucket, hanging feeding bucket, animal husbandry instruments, milk bottle ( feeding bottle), teat deep cup, gloves, apron, veterinary instruments, shed net, safety net, animal feed, hardware items, sanitary ware, tile, cable clamp, trefoil clamp, cable tray, grating, fencing net, hdpe net, fishing net, fasteners, ss, metal components, rubber parts, plastic parts, plastic components, rubber chemicals, industrial chemicals, etc
Buyer: Basic raw material like: plastic, rubber, chemicals, various metals etc
Supplier: Smartphones, laptops, televisions, cameras, speakers
dresses, shoes, handbags, t shirts, jeans, clothes
furniture, cookware, appliances, bedding, decorative items
skincare products, makeup, haircare products, perfumes,
vitamins and supplements,
fitness equipment, sports clothing, exercise accessories,
gym bags, outdoor gear
snacks and chips, beverages (soft drinks, juices, tea,
coffee) spices and seasonings, dairy products, canned goods,
edible oils products, olive oil, argan oil, coconut oil),
frozen foods (fish, chicken, meat, veg, fruits,)
car parts and accessories, car care products, gps and
navigation devices, car audio systems, tires
board games, action figures, puzzles, outdoor toys
educational toys
diapers, baby clothing, strollers, baby monitors, baby foods
hardware tools, safety equipment, electrical supplies,
plumbing supplies, construction materials, building
materials
Services: Export import, distribution, and bulk supply services including shipping and air clearing services
Buyer: Chemical & petrochemical industry
mechanical & electrical components
building & construction materials
machinery & equipments
foodstuffs & beverages
consumer electronics & fashion accessories
personal care & personal protection
clothes & apparel
automotive parts & accessories
I. Introduction SS-300-HCL Extractive Laser Analysis System adopts TDLAS Tunable diode laser absorption spectroscope to measure HF concentration. It adopts special heated sampling probe which is able to work in high-temperature and high dust conditions, and hot & wet sampling system with little gas loss caused by gas condensing. Compare in-situ type gas analyzer, the extractive system has the advantages of no requirement of installation conditions, easy maintenance, little pollution to mirror, suitable for dirty sampling point with high dust. II. Applications field It is used for stack outlet in the waste incineration power plant. III. Specifications Monitoring place Gas component Measurement range Waste incineration stack outlet HCL 0-20ppm(can be customize) 1.Measurement principleTDLAS 2.Sampling methodHot & Wet extractive sampling 3.Sampling pipe materialSUS316 4.Heated tube diameter: 86 5.Power supply AC220V±10%50/60Hz 6.Power consumptionMax 2000W+50W*heated tube length 7.Calibration periodeach 6 months 8.Analogue output4 - 20mA 9.Max load4 - 20mA 550© 10.Alarm outputgas temperature alarm, gas low pressure, gas over pressure alarm. IV. Features 1.Extractive sampling method 2.Easy calibration and calibration 3.Adopts TLDAS principle, little cross-sensitivity, 4.Laser detector with long lifespan 5.Optional sampling probe calibration function. 6.IP 65 protection class. 7.Adopts hot and wet sampling and gas pretreatment with temperature 190, preventing HCL gas loss by condensation. 8.Sampling probe with purging function. With lens blow up function, to prevent it dewing.
I. Introduction SS-300-HF Extractive Laser Analysis System adopts TDLAS Tunable diode laser absorption spectroscope to measure HF concentration. It adopts special heated sampling probe which is able to work in high-temperature and high dust conditions, and hot & wet sampling system with little gas loss caused by gas condensing. Compare in-situ type gas analyzer, the extractive system has the advantages of no requirement of installation conditions, easy maintenance, little pollution to mirror, suitable for dirty sampling point with high dust. II. Applications field It is used for online monitoring of organic waste gas emissions and organic waste gas recovery for chemical, printing, pharmaceutical, rubber, spray coating, electronic semiconductors, synthetic leather and so on. III. Specifications Monitoring place Gas component Measurement range aluminum oxide outlet HF 0-20ppm(can be customize) 1.Measurement principleTDLAS 2.Sampling methodHot & Wet extractive sampling 3.Sampling pipe materialSUS316 4.Heated tube diameter: ,¸8,?6 5.Power supply AC220V±10%50/60Hz 6.Power consumptionMax 2000W+50W*heated tube length 7.Calibration periodeach 6 months 8.Analogue output4 - 20mA 9.Max load550Ω 10.Alarm outputgas temperature alarm, gas low pressure, gas over pressure alarm. IV. Features 1.Extractive sampling method 2.Easy calibration and calibration 3.Adopts TLDAS principle, little cross-sensitivity, 4.Laser detector with long lifespan 5.Optional sampling probe calibration function. 6.IP 65 protection class. 7.Adopts hot and wet sampling and gas pretreatment with temperature 190â??, preventing HCL gas loss by condensation. 8.Sampling probe with purging function. 9.With lens blow up function, to prevent it dewing.
auxiliaries.-IBS antenna installation Length:1m(3.2feet) - 21m(68.8feet) Top payload:1kgs (2.2lbs) - 450kgs(992lbs) Material:aluminium alloy color:black white blue etc application:Emergency Lighting, Military, Antenna, Mobile Communication Tower. working type:by air pump or motor or handle bar working temp:-15--60â?? used for:antenna,camera,trussing,lights etc. mounted:on the ground or vehicle/trailer Certification:ce Type:Telecommunication Tower Place of Origin:CN;
Portable Wireless Gas Detector Industrial Smart Monitoring System smart monitoring system are prepared to prevent worker accidents at industrial sites. It is made up of products that are quick to propagate situations and easy to deal with emergencies, so it is easy to cope with the situation in the field Product List Portable Wireless Gas Sensor - All-in-one gas detector with wireless communication function - Rapid situation propagation and emergency response can be easily increased the level of safety management on the site - Measuring gas: O2, H2S, CO, LEL, CO2 Wireless Multi-gas monitoring System - Suitable for monitoring sealed space work or sites with choking or poisoning concerns - Up to 4 gas detectors can be stored simultaneously