Please click here to check who's online and chat with them.

Find Verified Electronic Transformers Suppliers, Manufacturers and Wholesalers

Nov-07-16
Supplier From Panchkula, Haryana, India
Apr-16-15
Supplier From Tianjin, China
Jul-22-17
Supplier From Bhavnagar, Gujarat, India
May-25-17
Supplier From New Delhi, Delhi, India
Nov-06-23
Supplier From Dongguan, Guangdong, China
698 Electronic Transformers Suppliers
Short on time? Let Electronic Transformers sellers contact you.
Oct-26-23
Sep-13-17
Supplier From Chongqing, Chinaq, China
Dec-04-24
Supplier From Chengdu., China
Dec-24-21
 
Overview

In the process of semi finished and finished production of power transformers, before the newly installed transformers are put into operation and according to the state Grid's preventive test rules, it is required to test the transformer's turn ratio or voltage ratio regularly.The traditional variable ratio bridge operation is tedious, the reading is not intuitive, and the necessary conversion, the test result is only one phase change ratio value.The transformer transformer ratio tester overcomes the shortcomings of the traditional transformer ratio bridge test, the screen uses a large screen high resolution LCD screen, convenient to use in the field, with Chinese menu prompt function, simple and intuitive operation, a complete three phase change ratio test, test speed, high accuracy.



Technical parameter

range 0.910000
The accuracy of
reading 0.1 2 words or equal to 500

reading 0.2 2 words 500 3000

Reading 0.3 2 words 3000

The resolution of the
0.9 9.9999 0.0001 100 999.99 0.01 10000 and above 1

10 99.999 0.001 1000 9999.9 0.1

Working power supply AC220V 10 50Hz
Instrument weight 3.5kg
The use of temperature 10 50
Overall dimensions 260mm l 200mm W 160mmH
Relative humidity 90 no dew


Feature

Full three phase sinusoidal inverter output, the output voltage is automatically adjusted, with soft start, soft stop function, so the test speed is fast, high precision

Three-phase transformer, single-phase transformer, PT, Z type transformer ratio, group, polarity test function

Blind test function, that is, variable ratio and group test when high and low pressure connection mode is not known;

CT variable ratio polarity test function

Angle difference test function for single-phase test

Tap position can be tested up to 197
GOLD Member
VERIFIED
Jul-12-24
Supplier From Mumbai, Maharashtra, India
Mar-24-21
Supplier From Vadodara, Gujarat, India
Oct-27-20
Supplier From Uttarpara, West Bengal, India
Jul-16-20
Supplier From Beawar, Rajasthan , India
Oct-24-19
Supplier From Delhi NCR, Delhi, India
Jan-21-08
Supplier From Tai'an, China
Aug-05-10
Supplier From Mianyang, China
Nov-13-09
Supplier From Kolkata, West Bengal, India
Mar-29-11
Supplier From Kolkata, West Bengal, India
Dec-06-12
Supplier From Zhongshan, Guangdong, China
Dec-18-12
Supplier From Beging, Pakistan
698 Electronic Transformers Suppliers
Short on time? Let Electronic Transformers sellers contact you.
See what buyers and suppliers are discussing in Electronic Transformers import export community