ALSTOM GBCDG11AF008SACH
SELF-POWERED INVERSE TIME O/C OR E/F REL
Technical Specifications
Relay Model No CDG11AF008SACH
Relay type CDG 11 Special
Case size 1D V 10T
Application O/C
Current setting 0.5 to 2 amps
Contacts 3 N/O S/R
Output contacts 2 N/O S/R
Taps Std
C.T.Secondary 1 amps
Burden 3 VA
Operating time 3 secs
Flag Yes
Mounting Flush
Name Plate RFG9126 771
Outline Diagram MFJ 012
Wiring Diagram MADZ 802.66-1
ALSTOM GBCDG11AF009SACH
SELF-POWERED INVERSE TIME O/C OR E/F REL
Technical Specifications
Relay Model No CDG11AF009SACH
Relay type CDG 11 Special
Case size 1D V 10T
Application E/F
Current setting 0.2 to 0.8 amps
Contacts 3 N/O S/R
Output contacts 2 N/O S/R
Taps Std
C.T.Secondary 1 amps
Burden 3 VA
Operating time 3 secs
Flag Yes
Mounting Flush
Name Plate RFG9126 793
Outline Diagram MFJ 012
Wiring Diagram MADZ 802.66-1
GBCDD21PF009SBCH
SELF-POWERED DIR. INVERSE TIME O/C OR E/
Technical specification
Relay model no CDD21PF009SBCH
Relay type CDD 21
Case size 1-1/2D Vert.10T
Application E/F
Burden 3 VA
C.T.Secondary 1 amps
Contacts (S/R OR H/R) 2 N/O S/R
D.M.T 3 SEC.
E/F OR U/V Setting 20-80%
Flag / Mounting Yes / Flush
Frequency 50 Hz
MTA PhaseE-char angle 14 Degrees E/F
O/C OR O/V Setting Not Applicable
V.T/P.T Secondary 63.5 to 190V A.C(E/F)
Name plate RFG9126-035
Outline drawing MFJ 013
Wiring diagram MPDZ 801.23
GBCDD21PF012SBCH
SELF-POWERED DIR. INVERSE TIME O/C OR E/
Technical Specifications
Relay Model No CDD21PF012SBCH
Relay type CDD 21(Self-powered)
CASE SIZE 1-1/2D V 10T
Application E/F
Current setting 0.1 to 0. 4 amps
V.T/P.T Secondary 63.5V to 190V ac
Burden / D.M.T 3 VA / 3 SECS
C.T.Secondary 1 amps
Output contacts 2 N/O S/R
Taps Std
E/F or U/V Setting 10 - 40% E/F
Flag / Mounting Yes / Flush
Frequency 50 Hz
MTA Phase-char angle 14 Deg
Name Plate RFG9126-035
Outline drawing MFJ 013
Wiring Diagram MPDZ 801.23
Gbcdd21pf015skch
Self-powered Dir. Inverse Time O/c or E/
Relay Model Gbcdd21pf015skch
Self-powered Dir. Inverse Time O/c or E/
Relay Model Cdd21pf015skch
Cdd21
Application E/f
Burden 3va
C.t. Secondary 5 Amp C.t.
Case Size 1-1/2d Vert. 10t
Contacts (S/r or H/r) 2 No 1nc H/r
D.m.t 3 Sec.
E/f or U/v Setting 10 - 40% E/f
Flag Yes
Frequency 50 Hz
Mounting Flush
Mta Phase-char Angle 45 Degrees
O/c or O/v Setting Not Applicable
V.t/p.t Secondary 63.5v to 190v Ac
Name Plate-1 Rfg9126 035
Outline Drawing Mfj 013
Wiring Diagram Mpdz 801.24
Cdd21
Application E/f
Burden 3va
C.t. Secondary 5 Amp C.t.
Case Size 1-1/2d Vert. 10t
Contacts (S/r or H/r) 2 No 1nc H/r
D.m.t 3 Sec.
E/f or U/v Setting 10 - 40% E/f
Flag Yes
Frequency 50 Hz
Mounting Flush
Mta Phase-char Angle 45 Degrees
O/c or O/v Setting Not Applicable
V.t/p.t Secondary 63.5v to 190v Ac
Name Plate-1 Rfg9126 035
Outline Drawing Mfj 013
Wiring Diagram Mpdz 801.24
ALSTOM GBCDD21PF9054BCH
SELF-POWERED DIR. INVERSE TIME O/C OR E/
Technical specification
Relay model no CDD21PF9054BCH
Relay type CDD 21
Case size 1-1/2D Vert.10T
Application E/F
Current setting 0.5 - 2.0 amps
Aux.current or voltage 100 - 250V dc
Burden 3 VA
C.T.Secondary 5 amps
Contacts (S/R OR H/R) 2 N/O S/R
D.M.T 3 secs
Taps Std
Flag Yes
Mounting Flush
Frequency 50 Hz
MTA Phase-char angle 60 Deg
V.T/P.T Secondary 63.5V ac
Name plate RFG9126-042
Outline drawing MFJ 013
Wiring diagram MPDZ 801-10-1
37916 Self Powered Dir Inverse Time O C Suppliers