Gbcdd21pf015skch
Self-powered Dir. Inverse Time O/c or E/
Relay Model Gbcdd21pf015skch
Self-powered Dir. Inverse Time O/c or E/
Relay Model Cdd21pf015skch
Cdd21
Application E/f
Burden 3va
C.t. Secondary 5 Amp C.t.
Case Size 1-1/2d Vert. 10t
Contacts (S/r or H/r) 2 No 1nc H/r
D.m.t 3 Sec.
E/f or U/v Setting 10 - 40% E/f
Flag Yes
Frequency 50 Hz
Mounting Flush
Mta Phase-char Angle 45 Degrees
O/c or O/v Setting Not Applicable
V.t/p.t Secondary 63.5v to 190v Ac
Name Plate-1 Rfg9126 035
Outline Drawing Mfj 013
Wiring Diagram Mpdz 801.24
Cdd21
Application E/f
Burden 3va
C.t. Secondary 5 Amp C.t.
Case Size 1-1/2d Vert. 10t
Contacts (S/r or H/r) 2 No 1nc H/r
D.m.t 3 Sec.
E/f or U/v Setting 10 - 40% E/f
Flag Yes
Frequency 50 Hz
Mounting Flush
Mta Phase-char Angle 45 Degrees
O/c or O/v Setting Not Applicable
V.t/p.t Secondary 63.5v to 190v Ac
Name Plate-1 Rfg9126 035
Outline Drawing Mfj 013
Wiring Diagram Mpdz 801.24
ALSTOM GBCDD21PF004SACH SELF-POWERED DIR. INVERSE TIME O/C OR E/ Technical Specifications Model No : CDD21PF004SACH CDD21(SELF-POWERED) APPLICATION - O/C BURDEN - 3VA C.T. SECONDARY - 5 AMP C.T. CASE SIZE - 1-1/2D VERT. 10T CONTACTS (S/R OR H/R) - 2 N/O S/R D.M.T - 3 SEC. E/F OR U/V SETTING - NOT APPLICABLE FLAG - YES FREQUENCY - 50 HZ MOUNTING - FLUSH MTA PHASE-CHAR ANGLE - 45 DEGREES O/C OR O/V SETTING - 50 - 200% V.T/P.T SECONDARY - 110V A.C(O/C) Name Plate RFG9126-021 Outline Diagram MFJ013 Wiring Diagram MPDZ801.23
ALSTOM GBCDD21PF006SACH SELF-POWERED DIR. INVERSE TIME O/C OR E/ Technical Specifications Model No : CDD21PF006SA(M) CDD21(SELF-POWERED) APPLICATION - O/C BURDEN - 3VA C.T. SECONDARY - 1 AMP CT. CASE SIZE - 1-1/2D VERT. 10T CONTACTS (S/R OR H/R) - 2 N/O S/R D.M.T - 3 SEC. E/F OR U/V SETTING - NOT APPLICABLE FLAG - YES FREQUENCY - 50 HZ MOUNTING - FLUSH MTA PHASE-CHAR ANGLE - 45 DEGREES O/C OR O/V SETTING - 50 - 200% V.T/P.T SECONDARY - 110V A.C(O/C) External Resistor Name Plate RFG9126-011 Outline Diagram MFJ013 Wiring Diagram MPDZ801.23
Alstom Gbcdd21pf006sach Self-powered Dir. Inverse Time O/c or E/ Technical Specifications Model No : Cdd21pf006sa(M) Cdd21(Self-powered) Application - O/c Burden - 3va C.t. Secondary - 1 Amp Ct. Case Size - 1-1/2d Vert. 10t Contacts (S/r or H/r) - 2 N/o S/r D.m.t - 3 Sec. E/f or U/v Setting - Not Applicable Flag - Yes Frequency - 50 Hz Mounting - Flush Mta Phase-char Angle - 45 Degrees O/c or O/v Setting - 50 - 200% V.t/p.t Secondary - 110v a.c(O/c) External Resistor Name Plate Rfg9126-011 Outline Diagram Mfj013 Wiring Diagram Mpdz801.23
Gbcdd21pf008sach Self-powered Dir. Inverse Time O/c or E/ Model Number Cdd21pf008sach Cdd21 Application O/c Burden 3va C.t. Secondary 1 Amp Ct. Case Size 1-1/2d Vert. 10t Contacts (S/r or H/r) 2 N/o S/r D.m.t 3 Sec. E/f or U/v Setting Not Applicable Flag Yes Frequency 50 Hz Mounting Flush Mta Phase-char Angle 45 Degrees O/c or O/v Setting 20 - 80% V.t/p.t Secondary 110v a.c(O/c) Name Plate-1 Rfg9126 011 Outline Drawing Mfj 013 Wiring Diagram Mpdz 801.23
GBCDD21PF008SBCH SELF-POWERED DIR.INVERSE IME E/F RELAY Technical Specifications Model No : CDD21PF008SB(M) CDD21(SELF-POWERED) APPLICATION - E/F BURDEN - 3VA C.T. SECONDARY - 1 AMP CT. CASE SIZE - 1-1/2D VERT. 10T CONTACTS (S/R OR H/R) - 2 N/O S/R D.M.T - 3 SEC. E/F OR U/V SETTING - 20-80% FLAG - YES FREQUENCY - 50 HZ MOUNTING - FLUSH MTA PHASE-CHAR ANGLE - 45 DEGREES O/C OR O/V SETTING - NOT APPLICABLE V.T/P.T SECONDARY - 63.5V AC TO 190V AC External Resistor Name Plate RFG9126-035 Outline Diagram MFJ013 Wiring Diagram MPDZ801.23
GBCDD21PF009SBCH SELF-POWERED DIR. INVERSE TIME O/C OR E/ Technical specification Relay model no CDD21PF009SBCH Relay type CDD 21 Case size 1-1/2D Vert.10T Application E/F Burden 3 VA C.T.Secondary 1 amps Contacts (S/R OR H/R) 2 N/O S/R D.M.T 3 SEC. E/F OR U/V Setting 20-80% Flag / Mounting Yes / Flush Frequency 50 Hz MTA PhaseE-char angle 14 Degrees E/F O/C OR O/V Setting Not Applicable V.T/P.T Secondary 63.5 to 190V A.C(E/F) Name plate RFG9126-035 Outline drawing MFJ 013 Wiring diagram MPDZ 801.23
Gbcdd21pf010sbch Self-powered Dir. Inverse Time O/c or E/ Technical Specifications Model Number Cdd21pf010sbch Cdd21 Application E/f Burden 3va C.t. Secondary 1 Amp Ct. Case Size 1-1/2d Vert. 10t Contacts (S/r or H/r) 2 N/o S/r D.m.t 3 Sec. E/f or U/v Setting 10 - 40% E/f Flag Yes Frequency 50 Hz Mounting Flush Mta Phase-char Angle 60 Degrees E/f V.t/p.t Secondary 63.5 to 190v a.c(E/f) Name Plate-1 Rfg9126035 Outline Drawing Mfj013 Wiring Diagram Mpdz801.23
Gbcdd21pf011sbch Self-powered Dir. Inverse Time O/c or E/ Technical Specifications Model No : Cdd21pf011sb(M) Cdd21(Self-powered) Application - E/f Burden - 3va C.t. Secondary - 1 Amp Ct. Case Size - 1-1/2d Vert. 10t Contacts (S/r or H/r) - 2 N/o S/r D.m.t - 3 Sec. E/f or U/v Setting - 10 - 40% E/f Flag - Yes Frequency - 50 Hz Mounting - Flush Mta Phase-char Angle - 45 Degrees O/c or O/v Setting - Not Applicable V.t/p.t Secondary - 63.5 to 190v a.c(E/f) External Resistor Name Plate Rfg9126-035 Outline Diagram Mfj013 Wiring Diagram Mpdz801.23
GBCDD21PF012SBCH SELF-POWERED DIR. INVERSE TIME O/C OR E/ Technical Specifications Relay Model No CDD21PF012SBCH Relay type CDD 21(Self-powered) CASE SIZE 1-1/2D V 10T Application E/F Current setting 0.1 to 0. 4 amps V.T/P.T Secondary 63.5V to 190V ac Burden / D.M.T 3 VA / 3 SECS C.T.Secondary 1 amps Output contacts 2 N/O S/R Taps Std E/F or U/V Setting 10 - 40% E/F Flag / Mounting Yes / Flush Frequency 50 Hz MTA Phase-char angle 14 Deg Name Plate RFG9126-035 Outline drawing MFJ 013 Wiring Diagram MPDZ 801.23