O2-M2 Oxygen Sensor Description
Alphasense Oxygen sensors use capillary flow control.

Unlike partial pressure oxygen sensors, they have good pressure and temperature dependence, making them the best choice in safety applications.

Standard galavanic sensors use lead for greatest reliability but fixed lifetime.

Specifications
* Output: 80 to 120 uA @ 20.9% O2
* Response time t90: < 15 (s) from 20.9% to 0% O2


* Linearity: 0.6 % O2 deviation @ 10% O2
* Operating life: > 24 months
*Temperature range: -30 to 55 'C
* Pressure range: 80 to 120 kPa
* Humidity range: 5 to 95 % rh continuous
* Diameter: 20.0 mm (including label)
* Heigh: 17.4 mm (including foam ring)
* Weight: < 16g
Oct-17-16
Supplier From Shenzhen, Nanshan, China
 
Oxygen sensor o2 gas sensor for portable gas detector
Model number: o2-a2


Performance
Output µa @ 20.9% o2 80 to 120
Response time t90 (s) from 20.9% to 0% o2 < 15
Zero current µa in n2 < 2.5
Linearity % o2 deviation @ 10% o2 0.6

Lifetime
Output drift % change in output @ 3 months < 1
Operating life months until 85% original output of 20.9% o2 > 24

Environmental
Humidity sensitivity % o2 change: 0% to 95% rh @ 40°c < 0.7
Co2 sensitivity % (change o2 reading) / % co2 @ 5% co2 0.1
Pressure sensitivity (% change of output)/(% change of pressure) @ 20kpa < 0.1

Key specifications
Temperature range °c -30 to 55
Pressure range kpa 80 to 120
Humidity range % rh continuous (0 to 99% rh short term) 5 to 95
Storage period months @ 3 to 20°c (store in sealed pot, open circuit) 6
Load resistor o (recommended) 47 to 100
Diameter mm (including label) 20.0
Height mm (including foam ring) 17.4
Weight g < 16
GOLD Member
Jun-12-25

Gp2Y0A60Szlf Distance Sensors Dist Meas Sensor, A

$36.61 - $49.70 / Piece (EXW)
MOQ: 1  Pieces
Sample Available
 
SENSOR OPTICAL 10-150CM ANALOG
GOLD Member
Mar-28-23
 
Our most advanced intelligent spot detectors, multi-criteria/multi-sensor devices use multiple sensors to detect various conditions in an environment sensing a wider range of fires with greater accuracy.

Features & Benefits:

Multi-Criteria/Multi-Sensor smoke detection
Unique ability to detect major elements of a fire
Highest nuisance alarm immunity
Advanced algorithms interpret and respond to multiple inputs
Jul-21-16
Supplier From Shenzhen, Guangdong, China
 
optical oxygen sensor O2 Gas sensor LOX-02
Description
The LuminOx Family is a range of factory calibrated optical sensors which measure ambient O2levels using the principle of fluorescence quenching by oxygen.
Our unique patented process allows us to produce an oxygen sensor that benefits from low power, traditionally associated with electrochemical sensing devices, while providing a much longer lifetime due to the non-depleting sensing principle.

Applications
Typical applications for the Cheap Price Oxygen Sensor LOX-02 are;
Oxygen detection
Portable equipment
Breathing apparatus
Inerting
Medical
Lab equipment
Agriculture
Incubation
Fore prevention
Flue gas in condensing boilers
15577 O2 M2 Oxygen Gas Sensor (O2 Sensor) Suppliers
Short on time? Let O2 M2 Oxygen Gas Sensor (O2 Sensor) sellers contact you.
Feb-27-17

O2S-Fr-T5 Oxygen Sensors

$1
MOQ: Not Specified
Supplier From Shenzhen, Guangdong, China
 
Features
* oxygen pressure range 2 mbar - 3bar
* zirconium dioxide (zro2 ) sensing elements
* non-consumption technology
* integral heating element
* no need for temperature stabilisation
* no reference gas required
* high accuracy
* linear output signal
* operates with external interface boards

Specifications
Heater voltage:
Porous cap (15mm): 4.35v dc +/- 0.1v dc (1.85a)
Stand by: 2v dc (0.85a)
Pump resistance @ 700'C: < 6kOhm
Permissible gas temperature: -100 to 250C
Gas flow rate: 0 to 10 m/s
Repetitive permissible acceleration: 5 g
Incidental permissible acceleration: 30 g
Feb-27-17
Supplier From Shenzhen, Guangdong, China
 
O2-a2 oxygen sensor

Performance
Output î¼a @ 20.9% o2 80 to 120
Response time t90 (s) from 20.9% to 0% o2 < 15
Zero current î¼a in n2 < 2.5
Linearity % o2 deviation @ 10% o2 0.6

Lifetime
Output drift % change in output @ 3 months < 1
Operating life months until 85% original output of 20.9% o2 > 24

Environmental
Humidity sensitivity % o2 change: 0% to 95% rh @ 40â?? < 0.7
Co sensitivity % (change o2 reading) / % co2 @ 5% co2 0.1
Pressure sensitivity (% change of output)/(% change of pressure) @ 20kpa < 0.1

Key specifications
Temperature range â?? -30 to 55
Pressure range kpa 80 to 120
Humidity range % rh non-condensing (0 to 99% rh short term) 5 to 95
Storage period months @ 3 to 20â?? (store in sealed pot, open circuit) 6
Load resistor î© (recommended) 47 to 100
Diameter mm (including label) 20.0
Height mm (including foam ring) 17.4
Weight g < 16

-
Mar-26-04
 
Thank you for purchasing and using our company's ultrasonic oxygen concentration / flow sensor.

1, please carefully read the instructions and fully understand the contents of the sensor after operation and maintenance. Improper use may cause damage to the sensor. (no violent impact and falling ground)
2, without the consent of the company, it is strictly prohibited to alter the structure and components of the sensor without authorization. The company is not responsible for any personal safety incidents or sensor abnormalities caused by unauthorized alterations.
3, the specifications and instruction contents of this sensor may be changed due to the technical improvement of the product.
4, this instruction manual must be handed to the actual user of the sensor and stored in it, and placed at any time where the actual user of the sensor can access it.
5, the company has the right to interpret the instructions for the sensor.

2ã??technical parameter
Measurement parameters measuring method range Resolution accuracy

O2 Ultrasonic 20.5%-95.6% 0.1% �±1.8%FS 5-45â??
Note: the range can be customized according to customer requirements.

Sample gas requirements Water removal (no condensation); dust filtration (
Dec-02-16
Supplier From Shenzhen, Guangdong, China
 
Features
* oxygen pressure range 2 mbar - 3bar
* zirconium dioxide (zro2 ) sensing elements
* non-consumption technology
* integral heating element
* no need for temperature stabilisation
* no reference gas required
* high accuracy
* linear output signal
* operates with external interface boards
* pcb mountable

Specifications
Heater supply*
Porous lid cap 4vdc +/- 0.1vdc (1.7a)
Stand by 1.65vdc (0.7a)
Full porous cap 4.35v dc +/- 0.1v dc (1.85a)
Stand by 2v dc (0.85a)
Dec-02-16
Supplier From Shenzhen, Guangdong, China
 
Features
* oxygen pressure range 2 mbar - 3bar
* zirconium dioxide (zro2 ) sensing elements
* non-consumption technology
* integral heating element
* no need for temperature stabilisation
* no reference gas required
* high accuracy
* linear output signal
* operates with external interface boards
* 80mm, 220mm and 400mm probes available

Specifications
Heater supply*
Porous lid cap 4v dc +/- 0.1v dc (1.7a)
Stand by 1.65v dc (0.7a)
Full porous cap 4.35v dc +/- 0.1v dc (1.85a)
Stand by 2v dc (0.85a)
Jun-02-17
Supplier From Shenzhen, Nanshan, China
 
Zirconia O2 Sensors
Probe Series - Short Housing

The Probe Range of zirconium dioxide oxygen sensors are available in three lengths. Suitable for aggressive and polluted applications such as boiler exhausts. Longer probes are an ideal solution for thicker walled, insulated flue pipes.

FEATURES
* Zirconium dioxide (ZrO2) sensing elements
* Long life, non-depleting technology
* Integral heating element
* High accuracy
* Requires an external interface board to operate

BENEFITS
* No reference gas required
* No need for temperature stabilisation
* Compact enclosure

TECHNICAL SPECIFICATIONS
Heater voltage
Operating (standard response) 4V DC ± 0.1V DC (1.7A)
Standby 1.65V DC (0.7A)
Operating (fast response) 4.35V DC ± 0.1V DC (1.85A)
Standby 2V DC (0.85A)
Pump impedance at 700'C < 6kΩ
Permissible gas temperature -100'C to +250'C
Gas flow rate 0 ~ 10 m/s
Repetitive permissible acceleration 5g
Incidental permissible acceleration 30g

OUTPUT VALUES
Oxygen pressure range 2mbar ~ 3bar max
Accuracy 5mbar max
Internal operational temperature 700'C
Response time (10 - 90% step)
Standard response sensor < 15s
Fast response sensor < 4s
Warm up time (prior to sensor operation) 60s
Warm up time (from standby) 20s
Output stabilisation time ~ 180s
Jun-02-17
Supplier From Shenzhen, Nanshan, China
 
Zirconia O2 Sensors
Probe Series - Long Housing

FEATURES
* Zirconium dioxide (ZrO2) sensing elements
* Long life, non-depleting technology
* Integral heating element
* High accuracy
* Requires an external interface board to operate

BENEFITS
* No reference gas required
* No need for temperature stabilisation
* Two lengths available; 220mm and 400mm

TECHNICAL SPECIFICATIONS
Heater voltage
Operating 4V DC ± 0.1V DC (1.7A)
Standby 1.65V DC (0.7A)
Pump impedance at 700'C < 6kohm
Permissible gas temperature
Standard temperature -100'C to +250'C
High temperature -100'C to +400'C
Gas flow rate 0 - 10 m/s
Repetitive permissible acceleration 5g
Incidental permissible acceleration 30g

OUTPUT VALUES
Oxygen pressure range 2mbar - 3bar max
Accuracy 5 mbar max
Internal operational temperature 700'C
Response time (10 - 90% step) < 15s
Warm up time (prior to sensor operation) 100s
Warm up time (from stand by) 20s
Output stabilisation time ~ 180s
May-10-17
Supplier From Shenzhen, Nanshan, China
 
FEATURES
* Oxygen pressure range 2 mbar - 3bar
* Zirconium dioxide (ZrO2 ) sensing elements
* Non-consumption technology
* Integral heating element
* No need for temperature stabilisation
* No reference gas required
* High accuracy
* Linear output signal
* Operates with external interface boards

SPECIFICATIONS
Heater Voltage
Porous Cap (15mm) 4.35V DC ± 0.1V DC (1.85A)
Stand by 2V DC (0.85A)
Pump resistance @ 700'C < 6kâ?¦
Permissible gas temperature -100 to 250'C
Gas flow rate 0 to 10 m/s
Repetitive permissible acceleration 5 g
Incidental permissible acceleration 30 g

z
GOLD Member
Jan-20-23
Supplier From Dhaka, Dhaka, Bangladesh
 
Honeywell BW Solo is a easy to service single-gas detector with BLE connectivity that provides real-time visibility into the status and safety of hazardous-area workers, helping companies respond faster, more knowingly and decisively to safety incidents. The first single-gas detector with the 1 Series sensor for CO, H2S and O2

Features & Benefits:
User-friendly operation,
Easy-to-read display for multiple languages,
Lightweight convenience,
Ease of maintenance,
Serviceability,
The new 1-Series sensor for enhanced reliability,
Connected Bluetooth Low Energy (BLE) capabilities.
Jun-23-17
Supplier From Shenzhen, Nanshan, China
 
Zirconia o2 sensors
Miniature series

The miniature zirconium dioxide oxygen sensors can be pcb mounted and are used when measuring ambient gas with the complete sensor immersed in the atmosphere which is to be measured.

Features
* zirconium dioxide (zro2 ) sensing elements
* long life, non-depleting technology
* integral heating element
* high accuracy
* requires an external interface board to operate

Benefits
* no reference gas required
* no need for temperature stabilisation
* pcb mountable

Technical specifications
Heater voltage
Standard response sensor: 4v dc â± 0.1v dc (1.7a)
Standby: 1.65v dc (0.7a)
Fast response sensor: 4.35v dc â± 0.1v dc (1.85a)
Standby: 2v dc (0.85a)
Pump impedance at 700'c: < 6k
Permissible gas temperature: -100'c to +250'c
Gas flow rate : 0 - 10 m/s
Repetitive permissible acceleration: 5g
Incidental permissible acceleration: 30g

Output values
Oxygen pressure range: 2mbar - 3bar max
Accuracy: 5mbar max
Internal operational temperature: 700'c
Response time (10 - 90% step)
Standard response sensor:
Oct-17-16
Supplier From Shenzhen, Nanshan, China
 
1.General description
The luminox family (lox) is a range of factory calibrated oxygen sensors which measure ambient oxygen partial pressure (ppo2) levels using the principle of fluorescence quenching by oxygen.
By default luminox measures ppo2 (mbar) and temperature (°c). An optional pressure sensor enables luminox to also measure barometric pressure (mbar) and to convert the ppo2 reading to an oxygen concentration (o2%).
The sensor benefits from low power operation, traditionally associated with electrochemical sensors, while providing a much longer lifetime due to the non-depleting sensing principle.
Luminox is ppo2 and temperature compensated, enabling accurate operation over a wide environmental range without the need for additional system components. Unlike other sensor technologies, luminox is very stable and robust, does not contain lead or any other
Hazardous materials and has negligible cross sensitivity to other gases.

2.Cleaning
The housing of the sensor can be cleaned using a damp cloth. The sensor should not be immersed in any cleaning media.
Full application and technical support can be provided by our knowledgable and highly experienced engineering team if required.

3.Benefits
-low power
-can also measure o2% & barometric pressure (lox-02)
-suitable for battery power use
-long life
- high accuracy
- small & compact
- low cost
-maintenance free contains no hazardous materials
-connects directly to microcontroller
- without any additional circuitry.
- factory calibrated

4.Applications
-oxygen detection
-portable equipment
- breathing apparatus
- inerting
- medical
-lab equipment
- agriculture
-incubation
-fire prevention
- flue gas in condensing boilers
Dec-02-16
Supplier From Shenzhen, Guangdong, China
 
Features
* oxygen pressure range 2 mbar - 3bar
* zirconium dioxide (zro2) sensing elements
* non-consumption technology
* integral heating element
* no need for temperature stabilisation
* no reference gas required
* high accuracy
* linear output signal
* operates with external interface boards
* m18x1.5 screw mount

Specifications
Heater voltage* 4.35v dc +/- 0.1v dc (1.85a)
Stand by 2v dc (0.85a)
Jun-13-17
Supplier From Shenzhen, Nanshan, China
 
Luminox ppm fluorescence o2 sensors features
* fluorescenceâ??based optical technology
* contains no hazardous materials; rohs & reach compliant
* factory calibrated
* high accuracy
* maintenance free
* long life, non-depleting technology - can be stored in any oxygen %

Luminox ppm fluorescence o2 sensors benefits
* low power, long life due to non-depleting sensing principle
* compact footprint

Luminox ppm fluorescence o2 sensors technical specifications
Supply voltage (vs) : 8-30v dc
Supply current (ls) :
GOLD Member
VERIFIED
Mar-15-17
Supplier From Buenos Aires, Argentina
 
ANALYSIS VALUES

Organoleptic Bright, clear; with absence of foreign odors and flavors
Peroxide index 0.1 – 1.0 (meq O2 / Kg)
Free fatty acid as oleic acid 0.03 – 0.07 (g / 100g)
Lovibond color
Yellow 10 – 15 (in 133.35mm cell)
Red 0.6 – 1.5 (in 133.35mm cell)
Unsaponifiable matter Max.: 1.00 (g / 100g)
Soap Max.: 10 (ppm)
Winter Test Oil will remain clear after cooling it for 24hs a 0ºC
Moisture and volatile matter Max.: 0.05 (g / 100g)
Impurities Will not contain naked eye
Insoluble impurities Max.: 0.02 (g / 100g)
Specific gravity at 25ºC 0.9133 – 0.9175
Refractive index at 25ºC 1.4706 – 1.4740
Iodine index 110 – 140 (g I2 / 100g)
Saponification value 188 – 192 (mg OHK / g)
Halphen – Gastaldi test Negative
Linolenic acid Max.: 0.3 (as fatty acid / 100g of total fatty acids)
Jun-24-17
Supplier From Shenzhen, Nanshan, China
 
Zirconia o2 sensors
Probe series - long housing

Features
* zirconium dioxide (zro2) sensing elements
* long life, non-depleting technology
* integral heating element
* high accuracy
* requires an external interface board to operate

Benefits
* no reference gas required
* no need for temperature stabilisation
* two lengths available; 220mm and 400mm

Technical specifications
Heater voltage
Operating: 4v dc ± 0.1v dc (1.7a)
Standby: 1.65v dc (0.7a)
Pump impedance at 700'c: < 6k
Permissible gas temperature
Standard temperature: -100'c to +250'c
High temperature: -100'c to +400'c
Gas flow rate: 0 - 10 m/s
Repetitive permissible acceleration: 5g
Incidental permissible acceleration: 30g

Output values
Oxygen pressure range: 2mbar - 3bar max
Accuracy: 5 mbar max
Internal operational temperature: 700'c
Response time (10 - 90% step): < 15s
Warm up time (prior to sensor operation): 100s
Warm up time (from stand by): 20s
Output stabilisation time: ~ 180s
15577 O2 M2 Oxygen Gas Sensor (O2 Sensor) Suppliers
Short on time? Let O2 M2 Oxygen Gas Sensor (O2 Sensor) sellers contact you.