Please click here to check who's online and chat with them.

Find Verified Temperature Controllers Indicators Suppliers, Manufacturers and Wholesalers

VERIFIED
Jun-14-21
 
ALSTOM GBCDG11AF015SCCH
SELF-POWERED INVERSE TIME O/C OR E/F REL
Technical Specifications
Model No : CDG11AF015SC(M)
CDG11
APPLICATION - E/F
BURDEN / D.M.T - 3VA / 1.3 SECS.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F OR U/V SETTING - 0.2 - 0.8 Amps.
FLAG - YES
MOUNTING - FLUSH
O/C OR O/V SETTING - NOT APPLICABLE
Name Plate RFG9125 793
Outline Diagram MFJ012
Wiring Diagram MADZ802.64-1
VERIFIED
Jun-14-21
 
ALSTOM GBCDG11AF016SACH
SELF-POWERED INVERSE TIME O/C OR E/F REL
Technical Specifications
Model No : CDG11AF016SA(M)
CDG11
APPLICATION - E/F
BURDEN / D.M.T - 3VA / 1.3 SECS.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F OR U/V SETTING - 0.1 - 0.4 Amps.
FLAG - YES
MOUNTING - FLUSH
O/C OR O/V SETTING - NOT APPLICABLE
Name Plate RFG9125692
Outline Diagram MFJ012
Wiring Diagram MADZ802.63-1
VERIFIED
Jun-14-21
 
ALSTOM GBCDG11AF016SCCH
SELF-POWERED INVERSE TIME O/C OR E/F REL
Technical Specifications
Model No : CDG11AF016SC(M)
CDG11
APPLICATION - E/F
BURDEN / D.M.T - 3VA /1.3 SECS.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F OR U/V SETTING - 0.1 - 0.4 Amps.
FLAG - YES
MOUNTING - FLUSH
O/C OR O/V SETTING - NOT APPLICABLE
Name Plate RFG9125 792
Outline Diagram MFJ012
Wiring Diagram MADZ802.64-1
VERIFIED
Jun-14-21
 
GBCDG11AF018SACH
SELF-POWERED INVERSE TIME O/C OR E/F REL
Technical Specifications
Relay Model No CDG11AF018SACH
Relay type CDG 11 Special
Case size 1D V 10T
Application E/F
Current setting 0.2 to 0.8 amps
Contacts 3 N/O S/R
Output contacts 2 N/O S/R
Burden 3 VA
Operating time 1.3 secs
Taps Std
Frequency 50 Hz
Flag Yes
Mounting Flush
Name Plate RFG9125 793
Outline Diagram MFJ 012
Wiring Diagram MADZ 802.66-1
VERIFIED
Jun-14-21
 
ALSTOM GBCDG11AF106SACH
SELF-POWERED INVERSE TIME O/C ORE/F 60HZ
Technical Specifications
Model No CDG11AF106SACH
CDG11
Application - E/F
Burden / D.M.T - 3Va / 3 Secs.
C.T. Secondary - 1 Amp
Case Size - 1D V 10T
Contacts - 2 N/O S/R
Current Setting - 0.1 - 0.4 Amps.
Flag - Yes
Mounting - Flush
Taps - STD
Frequncy - 60 Hz
Note:-In NamePlate write 60 Hz in place of 50 Hz
Name Plate RFG9126792
Outline Diagram MFJ012
Wiring Diagram MADZ802.63-1
2125 Temperature Controllers Indicators Suppliers
Short on time? Let Temperature Controllers Indicators sellers contact you.
VERIFIED
Jun-14-21
 
Alstom Gbcdg11af8101kch
Idmt O/c Relay, Bss Curve,ac Series Trip
Technical Specification
Model No. Cdg11af8101kch
Application O/c
Burden / D.m.t 3va / 3 Secs.
C.t. Secondary 5 Amp C.t.
Case Size 1d V 10t
Contacts (S/r or H/r) 2 N/o 2 N/c H/r
E/f or U/v Setting Not Aplicable
Flag Yes
Frequency 50 Hz
Mounting Flush
O/c or O/v Setting 2.5 - 10 Amps.
Name Plate-1 Rfg9126674
Outline Drawing Mfj012
Wiring Diagram Madz821-17
VERIFIED
Jun-14-21
 
ALSTOM GBCDG11AF8104KCH
INV.TIME O/C OR E/F RELAY FOR AC SERIES
Technical Specifications
Model No : CDG11AF8104K(M)
CDG11 S/T
APPLICATION - E/F
BURDEN / D.M.T - 3 VA / 3 SECS.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F OR U/V SETTING - 0.5 - 2 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C OR O/V SETTING - NOT APPLICABLE
Name Plate RFG9126695
Outline Diagram MFJ012
Wiring Diagram MADZ821-17
VERIFIED
Jun-14-21
 
ALSTOM GBCDG11AF9007ACH
INVERSE TIME E/F RELAY MULTI-AUX-VOLTAGE
Technical specification
Relay model no CDG11AF9007ACH
Relay type CDG 11
Case size 1D S/E
Application E/F
Current setting 1 to 4 amps
C.T.Secondary 5 amps
Taps Std
Burden 3 VA
Operating time 3 secs
Frequency 50 Hz
Aux.voltage vdc 30-50 / 100-125 V
220-250 V dc
Contacts shunt 2 N/O S/R
Flag Yes
Mounting Type Flush
Name plate RFG9126 796
Outline drawing MFJ 012
Wiring diagram MADZ 802.26-1
VERIFIED
Jun-14-21

Alstom Relay

$2.00K
MOQ: Not Specified
 
Alstom Gbcdg21af001zmch
Obsoleted Model Ref.gbcdg21af101zmch
Obsoleted Model Ref.gbcdg21af101zmch
VERIFIED
Jun-14-21

Alstom Relay

$1.50K
MOQ: Not Specified
 
Alstom Gbcdg21af003zmch
Obsoleted Model Ref.gbcdg21af102zmch
Obsoleted Model Ref.gbcdg21af102zmch
VERIFIED
Jun-14-21
 
ALSTOM GBCDG21AF035SYCH
IDMT EARTH FAULT RELAY WITH H/SET CAG13
TECHNICAL SPECIFICATION
Relay Model CDG21AF035SYCH
Relay Type CDG 21 SPR
Application E/F
Case Size 1D V 10T
C.T. Secondary 1 Amp
E/F Setting 0.1 TO 0.4 Amps
Frequency 50 Hz
Burden / D.M.T 3 Va / 1.3 Secs
Contacts 2 N/O 2 N/C H/R
Flag Yes
High Set Type CAG13
Highset Contacts 2 N/O S/R
Highset E/F Setting 2 TO 8 Amps
Mounting Flush
Name Plate RFG9125 792
Outline Drawing MFJ 012
Wiring Diagram MADZ821.29-1
VERIFIED
Jun-14-21
 
ALSTOM GBCDG21AF101ZMCH
1 POLE INV.TIME O/C OR E/F RELAY WITH IN
Technical Specifications
Model No : CDG21AF101ZM(M)
CDG21/CAG17(MRK-III)
APPLICATION - O/C
BURDEN / D.M.T - 3VA / 3 SEC.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O S/R
FLAG - YES
FREQUENCY - 50 HZ
HIGH SET TYPE - CAG17
HIGHSET CONTACTS - 2M S/R
HIGHSET O/C SETTING - 12.5-100 Amps.
MOUNTING - FLUSH
O/C SETTING - 2.5 - 10 Amps.
Name Plate RFG9126 674
Outline Diagram MFJ 012
Wiring Diagram MADZ821.31
VERIFIED
Jun-14-21
 
GBCDG21AF101ZNCH
1 POLE INV.TIME O/C OR E/F RELAY WITH IN
TECHNICAL SPECIFICATION
Relay Model CDG21AF101ZNCH
CDG21/CAG17(MRK-III)
Application - O/C
Case Size - 1D V 10T
Burden / D.M.T - 3Va / 3 Secs
C.T. Secondaray - 5 Amp C.T.
Contacts - 2 N/O 1 N/C H/R
Flag - Yes
Frequency - 50 Hz
High Set Type - CAG17
Highset Contacts - 2M S/R
Highset O/C Setting - 12.5-100 Amps.
Mounting - Flush
O/C Setting - 2.5 - 10 Amps.
Name Plate RFG9126-774
Outline Drawing MFJ 012
Wiring Diagram MADZ821.32
VERIFIED
Jun-14-21
 
ALSTOM GBCDG21AF102ZMCH
1 POLE INV.TIME O/C OR E/F RELAY WITH IN
Model No : CDG21AF102ZM(M)
CDG21/CAG17(MRK-III)
APPLICATION - O/C
BURDEN / D.M.T - 3 VA / 3 SEC.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O S/R
FLAG - YES
FREQUENCY - 50 HZ
HIGH SET TYPE - CAG17
HIGHSET CONTACTS - 2M S/R
HIGHSET O/C SETTING - 2.5-20 Amps.
MOUNTING - FLUSH
O/C OR O/V SETTING - 0.5 - 2 Amps.
Name Plate RFG9126 671
Outline Diagram MFJ 012
Wiring Diagram MADZ821.31
VERIFIED
Jun-14-21
 
ALSTOM GBCDG21AF102ZNCH
1 POLE INV.TIME O/C OR E/F RELAY WITH IN
Model No : CDG21AF102ZNCH
CDG21
APPLICATION O/C
BURDEN / D.M.T 3VA / 3 SEC.
C.T. SECONDARY 1 AMP CT.
CASE SIZE 1D V 10T
CONTACTS (S/R OR H/R) 2 N/O 1 N/C H/R
FLAG YES
FREQUENCY 50 HZ
HIGH SET TYPE CAG17
HIGHSET CONTACTS 2M S/R
HIGHSET O/C SETTING 2.5-20 Amps.
MOUNTING FLUSH
O/C SETTING 0.5 - 2 Amps
NAME PLATE-1 RFG9126 671
OUTLINE DRAWING MFJ 012
WIRING DIAGRAM MADZ821.32
VERIFIED
Jun-14-21
 
GBCDG21AF103ZMCH
1 POLE INV.TIME O/C OR E/F RELAY WITH IN
Model No : CDG21AF103ZM(M)
CDG21/CAG17(MRK-III)
APPLICATION - E/F
BURDEN / D.M.T - 3 VA / 3 SEC.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F SETTING - 1 - 4 Amps.
FLAG - YES
FREQUENCY - 50 HZ
HIGH SET TYPE - CAG17
HIGHSET CONTACTS - 2M S/R
HIGHSET E/F SETTING - 5 - 40 Amps.
MOUNTING - FLUSH
Name Plate RFG9126 696
Outline Diagram MFJ 012
VERIFIED
Jun-14-21
 
ALSTOM GBCDG21AF104ZMCH
1 POLE INV.TIME O/C OR E/F RELAY WITH IN
Model No : CDG21AF104ZM(M)
CDG21/CAG17(MRK-III)
APPLICATION - E/F
BURDEN / D.M.T - 3 VA / 3 SEC.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F SETTING - 0.5 - 2 Amps.
FLAG - YES
FREQUENCY - 50 HZ
HIGH SET TYPE - CAG17
HIGHSET CONTACTS - 2M S/R
HIGHSET E/F SETTING - 5 - 40 Amps.
MOUNTING - FLUSH
Name Plate RFG9126 695
Outline Diagram MFJ 012
Wiring Diagram MADZ821.31
VERIFIED
Jun-14-21
 
ALSTOM GBCDG21AF104ZNCH
1 POLE INV.TIME O/C OR E/F RELAY WITH IN
RELAY MODEL CDG21AF104ZNCH
CDG21
APPLICATION E/F
BURDEN / D.M.T 3 VA / 3 SEC.
C.T. SECONDARY 5 AMP C.T.
CASE SIZE 1D V 10T
CONTACTS (S/R OR H/R) 2 N/O 1 N/C H/R
E/F OR U/V SETTING 0.5 - 2 Amps.
FLAG YES
FREQUENCY 50 HZ
HIGH SET TYPE CAG17
HIGHSET CONTACTS 2M S/R
HIGHSET E/F SETTING 5 - 40 Amps.
MOUNTING FLUSH
NAME PLATE-1 RFG9126 695
OUTLINE DRAWING MFJ 012
WIRING DIAGRAM MADZ821.32
VERIFIED
Jun-14-21
 
ALSTOM GBCDG21AF105ZMCH
1 POLE INV.TIME O/C OR E/F RELAY WITH IN
Technical specification
Relay Model No - CDG21AF105ZMCH
CDG21/CAG17(MRK-III)
Case size - 1D V 10T
Application - E/F
Current setting - 0.2 to 0.8 amps
Burden / D.M.T - 3 VA / 3 sec
C.T.Secondary/Frequency - 1 amps /50 Hz
Contacts (S/R OR H/R) - 2 N/O S/R
Flag - Yes
Mounting - Flush
High set type - CAG17
Highset contacts - 2M S/R
Highset E/F Setting - 1 to 8 amps
Name Plate RFG9126 793
Outline Diagram MFJ 012
Wiring Diagram MADZ821.31
VERIFIED
Jun-14-21
 
ALSTOM GBCDG21AF105ZNCH
1 POLE INV.TIME O/C OR E/F RELAY WITH IN
Model No : CDG21AF105ZNCH
CDG21
APPLICATION E/F
BURDEN / D.M.T 3VA / 3 SEC.
C.T. SECONDARY 1 AMP CT.
CASE SIZE 1D V 10T
CONTACTS (S/R OR H/R) 2 N/O 1 N/C H/R
E/F SETTING 0.2 - 0.8 Amps.
FLAG YES
FREQUENCY 50 HZ
HIGH SET TYPE CAG17
HIGHSET CONTACTS 2M S/R
HIGHSET E/F SETTING 1 - 8 Amps.
MOUNTING FLUSH
NAME PLATE-1 RFG9126 693
OUTLINE DRAWING MFJ 012
WIRING DIAGRAM MADZ821.32
2125 Temperature Controllers Indicators Suppliers
Short on time? Let Temperature Controllers Indicators sellers contact you.
See what buyers and suppliers are discussing in Temperature Controllers Indicators import export community