ALSTOM GBCDD21PFB2AA5C
DIRECTIONAL IDMT O/C RELAY,3VA 3SEC DMT
Technical specification
Relay model no CDD21PFB2AA5C
Relay type CDD 21
Case size 1.5D S.E 10 T
Application O/C
Current setting 2.5 to 10 amps
Contacts 1 N/O S/R
Output contacts 1 N/O S/R
Flag Mech Flag
Taps Std
C.T.Secondary 5 Amp
Burden/Operating time 3VA / 3 Secs
Nominal Voltage 100/120 V AC
Frequency 50 Hz
Name plate RFG9126 021
M.T.A.I Lead/Lag 45 Deg Lead
Note: Use ZB9016224 (RV1) In Place of RZB9016059
Outline drawing RFJ0070602
Wiring diagram PDZ 001-203
VERIFIED
Jun-14-21
 
ALSTOM GBCDG11AF001SACH
SELF-POWERED INVERSE TIME O/C OR E/F REL
Technical Specifications
Model No CDG11AF001SACH
CDG11
APPLICATION - O/C
BURDEN / D.M.T - 3VA / 3 SECS.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F OR U/V SETTING - NOT APPLICABLE
FLAG - YES
MOUNTING - FLUSH
O/C OR O/V SETTING - 2.5-10 Amps.
Name Plate RFG9126674
Outline Diagram MFJ012
Wiring Diagram MADZ802.63-1
VERIFIED
Jun-14-21
 
ALSTOM GBCDG11AF001SCCH
SELF-POWERED INVERSE TIME O/C OR E/F REL
Technical Specifications
Model No : CDG11AF001SC(M)
CDG11
APPLICATION - O/C
BURDEN / D.M.T - 3VA / 3 SECS.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F OR U/V SETTING - NOT APPLICABLE
FLAG - YES
MOUNTING - FLUSH
O/C OR O/V SETTING - 2.5-10 Amps.
Name Plate RFG9126 774
Outline Diagram MFJ012
Wiring Diagram MADZ802.64-1
VERIFIED
Jun-14-21
 
ALSTOM GBCDG11AF002SACH
SELF-POWERED INVERSE TIME O/C OR E/F REL
Technical Specifications
Model No CDG11AF002SACH
CDG11
APPLICATION - O/C
BURDEN/D.M.T - 3VA/3 SECS.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F OR U/V SETTING - NOT APPLICABLE
FLAG - YES
MOUNTING - FLUSH
O/C OR O/V SETTING - 0.5-2 Amps.
Name Plate RFG9126671
Outline Diagram MFJ012
Wiring Diagram MADZ802-63-1
VERIFIED
Jun-14-21
 
GBCDG11AF002SCCH
SELF-POWERED INVERSE TIME O/C OR E/F REL
Technical Specifications
Model No : CDG11AF002SC(M)
CDG11
APPLICATION - O/C
BURDEN / D.M.T - 3VA / 3 SEC.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F OR U/V SETTING - NOT APPLICABLE
FLAG - YES
MOUNTING - FLUSH
O/C OR O/V SETTING - 0.5-2 Amps.
Name Plate RFG9126 771
Outline Diagram MFJ012
Wiring Diagram MADZ802.64-1
2117 Temperature Controllers Indicators Suppliers
Short on time? Let Temperature Controllers Indicators sellers contact you.
VERIFIED
Jun-14-21
 
ALSTOM GBCDG11AF003SACH
SELF-POWERED INVERSE TIME O/C OR E/F REL
Technical Specifications
Model No CDG11AF003SACH
CDG11
APPLICATION - E/F
BURDEN / D.M.T - 3VA / 3 SECS.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F OR U/V SETTING - 1-4 Amps.
FLAG - YES
MOUNTING - FLUSH
O/C OR O/V SETTING - NOT APPLICABLE
Name Plate RFG9126796
Outline Diagram MFJ012
Wiring Diagram MADZ802.63-1
VERIFIED
Jun-14-21
 
ALSTOM GBCDG11AF003SCCH
SELF-POWERED INVERSE TIME O/C OR E/F REL
Technical Specifications
Model No : CDG11AF003SC(M)
CDG11
APPLICATION - E/F
BURDEN /D.M.T - 3VA / 3 SECS.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F OR U/V SETTING - 1-4 Amps.
FLAG - YES
MOUNTING - FLUSH
O/C OR O/V SETTING - NOT APPLICABLE
Name Plate RFG9126 796
Outline Diagram MFJ012
Wiring Diagram MADZ802.64-1
VERIFIED
Jun-14-21
 
ALSTOM GBCDG11AF004SACH
SELF-POWERED INVERSE TIME O/C OR E/F REL
Technical Specifications
Model No CDG11AF004SACH
CDG11
APPLICATION - E/F
BURDEN - 3VA / 3 SECS.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F OR U/V SETTING - 0.5 - 2 Amps.
FLAG - YES
MOUNTING - FLUSH
O/C OR O/V SETTING - NOT APPLICABLE
Name Plate RFG9126-795
Outline Diagram MFJ012
Wiring Diagram MADZ802.63-1
VERIFIED
Jun-14-21
 
ALSTOM GBCDG11AF004SCCH
SELF-POWERED INVERSE TIME O/C OR E/F REL
Technical Specifications
Model No : CDG11AF004SC(M)
CDG11
APPLICATION - E/F
BURDEN / D.M.T - 3VA / 3 SECS.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F OR U/V SETTING - 0.5 - 2 Amps.
FLAG - YES
MOUNTING - FLUSH
O/C OR O/V SETTING - NOT APPLICABLE
Name Plate RFG9126 795
Outline Diagram MFJ012
Wiring Diagram MADZ802.64-1
VERIFIED
Jun-14-21
 
ALSTOM GBCDG11AF005SACH
SELF-POWERED INVERSE TIME O/C OR E/F REL
Technical Specifications
Model No : CDG11AF005SA(M)
CDG11
APPLICATION - E/F
BURDEN / D.M.T - 3VA / 3 SECS.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F OR U/V SETTING - 0.2 - 0.8 Amps.
FLAG - YES
MOUNTING - FLUSH
O/C OR O/V SETTING - NOT APPLICABLE
Name Plate RFG9126793
Outline Diagram MFJ012
Wiring Diagram MADZ802.63-1
VERIFIED
Jun-14-21
 
ALSTOM GBCDG11AF005SCCH
SELF-POWERED INVERSE TIME O/C OR E/F REL
Technical Specifications
Model No : CDG11AF005SC(M)
CDG11
APPLICATION - E/F
BURDEN / D.M.T - 3VA / 3 SECS.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F OR U/V SETTING - 0.2 - 0.8 Amps.
FLAG - YES
MOUNTING - FLUSH
O/C OR O/V SETTING - NOT APPLICABLE
Name Plate RFG9126 793
Outline Diagram MFJ012
Wiring Diagram MADZ802.64-1
VERIFIED
Jun-14-21
 
GBCDG11AF011SCCH
SELF-POWERED INVERSE TIME O/C OR E/F REL
Technical Specifications
Model No : CDG11AF011SC(M)
CDG11
APPLICATION - O/C
BURDEN / D.M.T - 3VA / 1.3 SECS.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F OR U/V SETTING - NOT APPLICABLE
FLAG - YES
MOUNTING - FLUSH
O/C OR O/V SETTING - 2.5 - 10 Amps.
Name Plate RFG9125 774
Outline Diagram MFJ012
Wiring Diagram MADZ802.64-1
VERIFIED
Jun-14-21
 
ALSTOM GBCDG11AF012SACH
SELF-POWERED INVERSE TIME O/C OR E/F REL
Technical Specifications
Model No : CDG11AF012SA(M)
CDG11
APPLICATION - O/C
BURDEN / D.M.T - 3VA / 1.3 SECS.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F OR U/V SETTING - NOT APPLICABLE
FLAG - YES
MOUNTING - FLUSH
O/C OR O/V SETTING - 0.5 - 2 Amps.
Name Plate RFG9125671
Outline Diagram MFJ012
Wiring Diagram MADZ802.63-1
VERIFIED
Jun-14-21
 
GBCDG11AF012SCCH
IDMT OVER CURRENT RELAY
Technical Specifications
Relay Model No CDG11AF012SCCH
Relay type CDG 11
Case size 1D V 10T
Application O/C
Current setting 0.5 to 2 amps
Frequency 50 Hz
Contacts 2 N/O 2 N/C H/R
Output contacts 2 N/O 2 N/C H/R
Taps Std
Burden 3 VA
Operating time 1.3 Secs
C.T.Secondary 1 amps
Flag Yes
Mounting Flush
Name Plate RFG9125 771
Outline Diagram MFJ 012
Wiring Diagram MADZ802.64-1
VERIFIED
Jun-14-21
 
ALSTOM GBCDG11AF013SACH
SELF-POWERED INVERSE TIME O/C OR E/F REL
Technical Specifications
Model No : CDG11AF013SA(M)
CDG11
APPLICATION - E/F
BURDEN / D.M.T - 3VA / 1.3 SECS
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F OR U/V SETTING - 1 - 4 Amps.
FLAG - YES
MOUNTING - FLUSH
O/C OR O/V SETTING - NOT APPLICABLE
Name Plate RFG9125696
Outline Diagram MFJ012
Wiring Diagram MADZ802.63-1
VERIFIED
Jun-14-21
 
GBCDG11AF013SCCH
SELF-POWERED INVERSE TIME O/C OR E/F REL
Technical Specifications
Model No : CDG11AF013SCCH
CDG11
APPLICATION - E/F
BURDEN / D.M.T - 3VA / 1.3 SECS.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F OR U/V SETTING - 1 - 4 Amps.
FLAG - YES
MOUNTING - FLUSH
O/C OR O/V SETTING - NOT APPLICABLE
Name Plate RFG9125 796
Outline Diagram MFJ012
Wiring Diagram MADZ802.64-1
VERIFIED
Jun-14-21
 
ALSTOM GBCDG11AF014SACH
SELF-POWERED INVERSE TIME O/C OR E/F REL
Technical Specifications
Model No : - CDG11AF014SA(M)
CDG11
APPLICATION - E/F
BURDEN /D.M.T - 3VA /1.3 SECS.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F OR U/V SETTING - 0.5 - 2 Amps.
FLAG - YES
MOUNTING - FLUSH
O/C OR O/V SETTING - NOT APPLICABLE
Name Plate RFG9125-795
Outline Diagram MFJ012
Wiring Diagram MADZ802.63-1
VERIFIED
Jun-14-21
 
ALSTOM GBCDG11AF014SCCH
SELF-POWERED INVERSE TIME O/C OR E/F REL
Technical Specifications
Model No : CDG11AF014SC(M)
CDG11
APPLICATION - E/F
BURDEN / D.M.T - 3VA / 1.3 SECS.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F OR U/V SETTING - 0.5 - 2 Amps.
FLAG - YES
MOUNTING - FLUSH
O/C OR O/V SETTING - NOT APPLICABLE
Name Plate RFG9125 795
Outline Diagram MFJ012
Wiring Diagram MADZ802-64-1
VERIFIED
Jun-14-21
 
ALSTOM GBCDG11AF015SACH
SELF-POWERED INVERSE TIME O/C OR E/F REL
Technical Specifications
Model No : CDG11AF015SA(M)
CDG11
APPLICATION - E/F
BURDEN / D.M.T - 3VA / 1.3 SECS.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F OR U/V SETTING - 0.2 - 0.8 Amps.
FLAG - YES
MOUNTING - FLUSH
O/C OR O/V SETTING - NOT APPLICABLE
Name Plate RFG9125693
Outline Diagram MFJ012
Wiring Diagram MADZ802.63-1
VERIFIED
Jun-14-21
 
ALSTOM GBCDG11AF015SCCH
SELF-POWERED INVERSE TIME O/C OR E/F REL
Technical Specifications
Model No : CDG11AF015SC(M)
CDG11
APPLICATION - E/F
BURDEN / D.M.T - 3VA / 1.3 SECS.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 1D V 10T
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F OR U/V SETTING - 0.2 - 0.8 Amps.
FLAG - YES
MOUNTING - FLUSH
O/C OR O/V SETTING - NOT APPLICABLE
Name Plate RFG9125 793
Outline Diagram MFJ012
Wiring Diagram MADZ802.64-1