Please click here to check who's online and chat with them.

Find Verified Temperature Controllers Indicators Suppliers, Manufacturers and Wholesalers

Top Supplier Cities : Manila   -   Makati  
Jan-05-10
Supplier From Bacoor, Philippines
Jan-05-10
 
Size: FY400(48X48 mm), FY600(96X48mm), FY700(72X72mm), FY800(48X96mm), FY900(96X96mm)
Supply voltage: AC 85-265V, DC 24V
Frequency: 50/60 Hz
Memory: Non-volatile memory E PROM
Input: Universal
Thermocouple - type K, J, R, S, B, E, N,T , W5Re/W26Re
RTD - DPT100, JPT100, JPT50
mA dc - 4-20mA, 0-20mA
voltage Dc - 0-1V, 0-5V, 0-10V, 1-5V, 2-10V, -10-10mV 0-10 mV, 0-50mV, 10-50mV
DP position: 0000, 000.0, 00.00, 0.000 (available for mA or Voltage dc input).

Output:
Relay: SPST or SPDT Type 3A, 220V electrical life 100,000 times or more(under rated load)
Voltage Pulse: for SSR, On: 24V Off: 0V maximun load current 20mA
mA DC: 4-20 mA, 0-20 mA maximum load resistance 560 ohms
Voltage DC: 0-5V, 0-10V, 1-5V, 2-10V Maximum load current 20mA
Alarm: SPST or SPDT type 3A, 220V electrical life 100,000 times or more (under the rated load)
Control Algorithms: PID, P, PI, PD On/Off (P=0), Fuzzy
PID range P= 0-200%, I=0-3600 secs, D=0-900 Secs
Isolation: Output terminal ( control output, alarm, transmission) and input terminal are isolated separately
Operating Temperature: 0-50 deg C
Humidity: 20-90% RH
Optional Specs
RAMP/SOAK program : 2 patterns with 8 segments each, the 2 patterns can be linked together as 16 segments use
Output 2:
Relay: SPST or SPDT Type 3A, 220V electrical life 100,000 times or more(under rated load)
Voltage Pulse: for SSR, On: 24V Off: 0V maximun load current 20mA
mA DC: 4-20 mA, 0-20 mA maximum load resistance 560 ohms
Voltage DC: 0-5V, 0-10V, 1-5V, 2-10V Maximum load current 20mA
Alarms capable up to 3 alarms
Heater Break Alarm: Display range of Heater Current: 0.0-99.9A Accuracy 1%FS
Included CT; SC_80_T (5.8mm dia, 0.0-80.0A) or SC_100 12mm Dia, 0.0-99.9A)
Alarm Relay AL1
Transmission: Available for PV and SV transmission
mA DC: 4-20 mA, 0-20 mA maximum load resistance 560 ohms
Voltage DC: 0-5V, 0-10v, 1-5V, 2-10V maximum load current 20mA
Remote SV Input: 4-20mA, 0-20mA 0-5V 0-10V, 1-5V, 2-10V are available
Communication: Protocol: MODBUS RTU, MODBUS ASCII, TAIE
interface: RS232, RS485, TTL
Baudrate: 38400, 19200, 9600, 4800, 2400 bps.
8 bit, start bit: 1bit, Parity : ODD or even stop bit: 1 or 2 bit
WaterProof/Dustprof: IP65.
2 Temperature Controllers Indicators Suppliers
Short on time? Let Temperature Controllers Indicators sellers contact you.