Article number 3BSE013208R1
Communication protocol Modulebus
Master or slave Slave
Line redundancy No
Module redundancy No
Hot Swap No
S800 I/O is a comprehensive, distributed and modular process I/O system that communicates with parent controllers and PLCs over industry-standard field buses. The TB820V2 ModuleBus Modem is a fiber optic interface to the ModuleBus. The ModuleBus Modem has an electric and an optical interface which are logically the same bus. A maximum of 12 I/O modules can be connected to the electrical ModuleBus and up to seven clusters can be connected to the fiber optic ModuleBus. The fiber optic interface is intended for local distribution of I/O clusters and where more than 12I/O modules are required in an I/O station.
Features and benefits
2 fiber optic ports to optical ModuleBus
ModuleBus (electrical) to the I/O Modules
Supervisory functions of I/O ModuleBus and power supply
Isolated power supply to I/O modules
TB820/TB820V2 has a rotary switch that selects its cluster number, 1 to 7, on the optical ModuleBus
Dimensions
Width 58 mm (2.39 in.)
Height 170 mm (6.7 in.) including latch
Depth 122 mm (4.8 in.)
Weight 0.3 kg (0.66 lbs)
MODBUS TCP is an open industry standard widely spread due to its ease of use. It is a request-response protocol and offers services specified by function codes.
MODBUS TCP combines the MODBUS RTU with standard Ethernet and the universal networking standard TCP. It is an application-layer messaging protocol, positioned at level 7 of the OSI model. The CI867A/TP867 is used for connection between an AC 800M controller and external Ethernet devices using Modbus TCP protocol.
The CI867 expansion unit contains the CEX-Bus logic, a communication unit, and a DC/DC converter that supplies appropriate voltages from the +24 V supply via the CEX-Bus. The Ethernet cable must be connected to the main network through an Ethernet switch.
The CI867A only uses one Ethernet port (100 Mbit/s) compared with the earlier CI867, where two Ethernet ports could be used (100 Mbit/s and 10 Mbit/s). The CI867A module will only work with System 800xA 6.0.3.3, 6.1.1, and subsequent versions.
Features and benefits
The CI867A can be set redundant and supports hot swap.
CI867A is a single channel Ethernet unit; Ch1 supports full duplex with 100 Mbps speed. Both master and slave functionality are supported.
A maximum of 70 slave and 8 master units per CI867A can be used.
PROFIBUS DP is a high speed multipurpose bus protocol (up to 12Mbit/s) for interconnecting field devices, like remote I/O, drives, low voltage electrical equipment, and controllers. PROFIBUS DP can be connected to the AC 800M via the CI854B communication interface. The CI854B includes two PROFIBUS ports to realize line redundancy and it also supports PROFIBUS master redundancy.
Master redundancy is supported in PROFIBUS-DP communication by using two CI854B communication interface modules. The master redundancy can be combined with CPU redundancy and CEXbus redundancy (BC810). The modules are mounted on a DIN rail and interface directly with the S800 I/O system, and other I/O systems as well, including all PROFIBUS DP/DP-V1 and FOUNDATION Fieldbus proficient systems.
The PROFIBUS DP must be terminated at the two outermost nodes. This is usually done by using connectors with built-in termination. To guarantee a correct working termination the connector has to be plugged and power supplied.
Package including: a CI854BK01 Communication Interface and a TP854 Baseplate.
(Only compatible with System 800xA 6.0.3.2, Compact Control Builder 6.0.0-2 and onwards. Please see Product Update for more information.)
Features and benefits
Used for connecting remote I/O and fieldbus instruments via PROFIBUS DP
Possible to connect PROFIBUS PA to the CI854B via the PROFIBUS linking device LD 800P
The CI854B can be set redundant
156 Computer Cpu Suppliers
Short on time? Let Computer Cpu sellers contact you.
External DIN-rail mounted rechargeable battery unit for AC 800M controllers, including lithium-ion battery, 24V DC connector, and connection cable TK821V020. Width=85 mm. Equivalent amount of Lithium metal=0,8g (0,03oz)
Features and benefits
Simple DIN-rail mounting
Battery back-up for AC 800M
Article number 3BSE037760R1
Communication protocol Modulebus
Master or slave Slave
Line redundancy Yes
Module redundancy Yes
Hot Swap Yes
S800 I/O is a comprehensive, distributed and modular process I/O system that communicates with parent controllers and PLCs over industry-standard field buses. The TB840 ModuleBus Modem is a fiber optic interface to the Optical ModuleBus. TB840A is used in redundancy configurations where each module is connected to different optical ModuleBus lines, but connected to the same electrical ModuleBus.
The ModuleBus Modem has an electrical and an optical Modulebus interface which are logically the same bus. A maximum of 12 I/O modules can be connected to the electrical ModuleBus and up to seven clusters can be connected to the fiber optic ModuleBus. The fiber optic interface is intended for local distribution of I/O clusters and where more than 12 I/O modules are required in an I/O station.
Features and benefits
2 fiber optic ports to optical ModuleBus
ModuleBus (electrical) to the I/O Modules
Supervisory functions of I/O ModuleBus and power supply
Isolated power supply to I/O modules
TU840, MTU for redundant TB840/TB840A, dual ModuleBus
TU841, MTU for redundant TB840/TB840A, single ModuleBus
Input power fused
Dimensions
Width 54 mm (2.13 in.)
Height 119 mm (4.69 in.)
Depth 96 mm (3.78 in.)
Weight 0.2 kg (0.44 lbs)
Article number 3BSE041882R1
Communication protocol PROFIBUS DP-V1
Master or slave Slave
Line redundancy Yes
Module redundancy Yes
Hot Swap Yes
S800 I/O is a comprehensive, distributed and modular process I/O system that communicates with parent controllers and PLCs over industry-standard field buses. The CI840 Fieldbus Communication Interface (FCI) module is a configurable communication interface that performs operations such as signal processing, gathering of various supervision information, OSP handling, Hot Configuration In Run, HART pass-through and configuration of I/O modules. CI840 is designed for redundant applications. The FCI connects to the controller by way of the PROFIBUS-DPV1 fieldbus. Module termination units to use, TU846 with redundant I/O and TU847 with non-redundant I/O.
Features and benefits
PROFIBUS DP PROFIBUS-DPV1 fieldbus interface.
Supervisory functions of I/O ModuleBus
Isolated power supply to I/O modules
OSP handling and configuration
Input power fused
Hot Configuration In Run
HART pass-through
Dimensions
Width 54 mm (2.13 in.)
Height 119 mm (4.69 in.)
Depth 96 mm (3.78 in.)
Weight 0.2 kg (0.44 lbs.)
COMLI can be used on the built-in COM3 port and optionally on the CI853 ports. The cable length can be extended considerably (to several km) using a fiber optic converter. RS-232C is the standard communication interface used for serial communication with COMLI. The CI853 supports Hot Swap. COMLI is an ABB protocol for data transmission between controllers. It is designed for asynchronous master/slave communication in half-duplex. COMLI protocol supports dial-up modems controlled from the application. CI853 supports both Master/Slave modes in COMLI.
MODBUS RTU is a standard protocol widely spread because of its ease of use and reliability. Modbus RTU is an open, serial (RS-232 or RS-485) protocol derived from the Master/Slave architecture exchanging information in half duplex mode. The Modbus functionality can be configured both on the COM ports of AC 800M and CI853. Module Redundancy is not available in MODBUS RTU. CI853 supports only Master mode in MODBUS RTU.
Features and benefits
COMLI can be used on the built-in COM3 port and optionally on the CI853 ports. RS-232C is the standard communication interface used for serial communication with COMLI. The CI853 supports Hot Swap. COMLI is an ABB protocol for data transmission between controllers.
MODBUS RTU is an open, serial (RS-232) protocol derived from the Master/Slave architecture exchanging information in half duplex mode. The Modbus functionality can be configured both on the COM ports of AC 800M and CI853.
Siemens 3964R can be used on the built-in COM3 port and optionally on the CI853 ports. A standard RS-232C/485 communication channel is required.
Self-defined Serial Communication can be used on the built-in COM3 port (on an AC 800M Controller) and optionally on the CI853 ports.
The CI853 module also supports Hot Swap.
The CPU board contains the microprocessor and RAM memory, a real-time clock, LED indicators, INIT push button, and a CompactFlash interface.
The base plate of the PM862 controller has two RJ45 Ethernet ports (CN1, CN2) for connection to the Control Network, and two RJ45 serial ports (COM3, COM4). One of the serial ports (COM3) is an RS-232C port with modem control signals, whereas the other port (COM4) is isolated and used for the connection of a configuration tool. The controller supports CPU redundancy for higher availability (CPU, CEX-Bus, communication interfaces and S800 I/O).
Simple DIN rail attachment / detachment procedures, using the unique slide & lock mechanism. All base plates are provided with a unique Ethernet address which provides every CPU with a hardware identity. The address can be found on the Ethernet address label attached to the TP830 base plate.
(Only compatible with System 800xA 6.0.2, Compact Control Builder 6.0.0-1 and onwards. Please see Product Update for more information.)
Features and benefits
- ISA Secure certified - Read more
- Reliability and simple fault diagnosis procedures
- Modularity, allowing for step-by-step expansion
- IP20 Class protection without the requirement for enclosures
- The controller can be configured with 800xA control builder
- The controller has full EMC certification
- Sectioned CEX-Bus using a pair of BC810 / BC820
- Hardware based on standards for optimum communication connectivity
(Ethernet, PROFIBUS DP, etc.)
- Built-in redundant Ethernet Communication ports
General info
Article number 3BSE076940R1 (PM862K01)
Redundancy No
High Integrity No
Clock Frequency 67 Mhz
Performance, 1000 boolean operations 0.18 ms
Performance 0.18 ms
Memory 32 MB
RAM available for application 23.521 MB
Flash memory for storage Yes
Detailed data
Environment and certification
Dimensions
The CPU board contains the microprocessor and RAM memory a realtime clock LED indicators INIT push button and a CompactFlash interface
The base plate of the PM862 controller has two RJ45 Ethernet ports CN1 CN2 for connection to the Control Network and two RJ45 serial ports COM3 COM4 One of the serial ports COM3 is an RS232C port with modem control signals whereas the other port COM4 is isolated and used for the connection of a configuration tool The controller supports CPU redundancy for higher availability CPU CEXBus communication interfaces and S800 IO
Simple DIN rail attachment detachment procedures using the unique slide lock mechanism All base plates are provided with a unique Ethernet address which provides every CPU with a hardware identity The address can be found on the Ethernet address label attached to the TP830 base plate
Only compatible with System 800xA 602 Compact Control Builder 6001 and onwards Please see Product Update for more information
Package including
2 pcs PM862 CPU
2 pcs TP830 Baseplate width 115mm
2 pcs TB807 ModuleBus terminator
1 pcs TK850 CEXbus expansion cable
1 pcs TK851 RCULink cable
2 pcs Battery for memory backup 49430136 one for each controller
Features and benefits
ISA Secure certified Read more
Reliability and simple fault diagnosis procedures
Modularity allowing for stepbystep expansion
IP20 Class protection without the requirement for enclosures
The controller can be configured with 800xA control builder
The controller has full EMC certification
Sectioned CEXBus using a pair of BC810 BC820
Hardware based on standards for optimum communication connectivity
Ethernet PROFIBUS DP etc
Builtin redundant Ethernet Communication ports
The CPU board contains the microprocessor and RAM memory, a real-time clock, LED indicators, INIT push button, and a CompactFlash interface.
The base plate of the PM860A controller has two RJ45 Ethernet ports (CN1, CN2) for connection to the Control Network, and two RJ45 serial ports (COM3, COM4). One of the serial ports (COM3) is an RS-232C port with modem control signals, whereas the other port (COM4) is isolated and used for the connection of a configuration tool.
Simple DIN rail attachment / detachment procedures, using the unique slide & lock mechanism. All base plates are provided with a unique Ethernet address which provides every CPU with a hardware identity. The address can be found on the Ethernet address label attached to the TP830 base plate.
Features and benefits
Reliability and simple fault diagnosis procedures
Modularity, allowing for step-by-step expansion
IP20 Class protection without the requirement for enclosures
The controller can be configured with 800xA control builder
The controller has full EMC certification
Hardware based on standards for optimum communication connectivity (Ethernet, PROFIBUS DP, etc.)