This Transformer control boxof console is suitable for adjustable voltage control of 0.5-10kVA test transformer.
Technical Indicators
Maximum capacity
20kVA
Input voltage
220kV
Output voltage
0-250V
Maximum output current
0-90A
Mains phase number
single-phase
Power frequency
50HZ
Instructions precision
1.5 Class
Using Methods and Attention Matters
1.Check the test transformer measuring winding rated output voltage, and make it match the operation box correctly.
2. Connect the line between test transformer and operation box according to the wiring diagram.
3. Switch on the power supply, then close the knife switch, and the power indicator light, finally set the work time of relay.
4. Make the pressure regulator display zero, press the start button, the clockwise rotation of the hand wheel, until it reaches the required value.
5. Start the timing switch, timing begins, the electric bell will alarm automatically when it reaches the setting time(artificially controlled time if there is on alarming function), then break off the timing switch.
Q&A:
What is the difference between a control box and a box-type transformer
The control box has only control functions. It is a control unit. Its main function is to issue instructions to control the rapid breaking of the circuit breaker in the box substation; it is a component in the box substation.
The box-type transformer generally refers to the box-type substation, which integrates the functions of power transformation, power distribution, control, and protection.
Current transformer volt-ampere characteristic tester Only need to set the test voltage, current and step, the device will boost and trace voltage current characteristic test curve automatically, save the cumbersome labor of manual pressure regulation, artificial record, tracing curves, and so. Quick, simple and convenient.
I can not only test CT/PT DC resistance, volt-ampere characteristics, ratio and polarity, 10% error curve, angle difference and ratio difference, but also test secondary load of transformer, CT current test and PT AC withstand voltage test.
CT ratio not only supports traditional current method but also voltage method, so it can meet the test of CT in casing CT and GIS.
Volt-ampere characteristic test single machine output voltage 0-2500V, current 0-20A, can meet most of the transformer volt-ampere characteristic test.
220V single power input and avoids the risk of using 380V.
Current transformer volt-ampere characteristic tester
This device is designed and manufactured for 35kV cable AC withstand voltage test. The reactor is individually designed for multiple units, which can not only meet the test conditions of high-voltage and low-current equipment, but also meet the low-voltage AC withstand voltage test requirements of 10kV cables.
The special AC resonance test system for cables adopts the method of adjusting the frequency of the power supply, so that the reactor and the capacitor under test can achieve resonance, and the high voltage and large current can be obtained on the test product. It is a new method of current high voltage test and The trend has been widely used at home and abroad.
The AC resonance test system uses a dedicated SPWM digital waveform generator chip with a frequency resolution of 16 bits, and the frequency fineness can reach 0.1 Hz at 20 to 300 Hz; it adopts an orthogonal non-synchronous fixed carrier modulation method to ensure that the entire frequency The output waveform is good in the interval; the advanced IPM module is used in the power part to ensure the stability and safety of the instrument under the minimum weight.
The test system consists of a frequency and voltage regulation power supply, an excitation transformer, a reactor, and a capacitor divider.
Technical index
1. the resonant excitation power supply only needs 1/Q of test capacity, which is 1/10-1/30 of common test unit and reduces the system weight and volume greatly.
2. Rated voltage:
1.108kV meeting the alternating current withstand voltage test for 35kV cable;
2.Waveform distortion rate of output voltage should be less than 1.0
3.The permissible continuous working time is to work for 5 minutes at one time under rated condition.
4.Quality factor of unit itself: Q 50
Advantage
1.The power capacity needed is reduced greatly.
2.The weight and volume of equipment is reduced greatly.
3.The waveform of output voltage is improved.
4.The large short-circuit current is prevented from burning fault point.
Feature:
1. A large number of cables with voltage levels of 35kV and below are used, and the test workload is large, so this type of withstand voltage test device is small in size and light in weight, and a portable cable withstand voltage test system was born;
2. This system requires that the weight of the parts that a single person can move on-site does not exceed 30kg, and the weight of the parts that two people can move on-site does not exceed 60kg, which is suitable for on-site transportation;
3. The power supply adopts 220V single-phase power supply or 380V single-phase power supply, which is convenient for on-site power supply;
4. The reactor part is made of dry epoxy casting, which is beautiful and reliable, suitable for the requirements of various cables;
5. The withstand voltage test of 110kV and above cables adopts oil-immersed reactors.
The three-phase microcomputer relay control tester has a 4-phase voltage 3 phase current output, which is suitable for various types of relay protection devices. The microcomputer relay control tester uses a high-speed high-performance digital signal processor comparative speed, transmission frequency bandwidth, and software application bifurcation algorithm produces each of the respective high-precision waveforms. Due to the integrated structure, each part is closely coupled, the data transmission distance is short, and the structure is compact.
Technical parameter:
AC current output
Output accuracy Level 0.5
Phase current output (effective value) 0 40A
Three merge current output (effective value) 0 120A
Phase electric length time allows work value (effective value) 10A
Phase current maximum output power 420VA
Maximum output power at the maximum output of three 1000VA
Working time is allowed when the maximum output of the three mesh is output 10s
Frequency range (foundation) 20 1000Hz
Harmonic number 1 20 times
DC current output
Output accuracy Level 0.5
Current output 0 10A / each phase, 0 20A / two superimposed
Maximum output load voltage 20V
AC voltage output
Output accuracy Level 0.5
Phase voltage output (effective value) 0120V
Line voltage output (effective value) 0210V
Maximum voltage output value 0240V
Phase voltage / line voltage output power 80VA /100VA
Frequency range (fundamental) 201000Hz
Harmonics 1 20 times
The digital three-phase shifter is a portable electrical tester composed of transformer phase shifter, digital phase display, voltage current digital display, output voltage adjustment, coarse adjustment, fine adjustment, and power supply, etc. The digital three-phase shifter combines the transformer phase phase technology with digital measurement techniques, which can be adjusted at any angle in the range of 0 to 360 , which has high precision, reading. Accurate intuitive, the voltage output is adjustable, the digital three-phase shifter structural components use independent fixtures, firm and reliable, full seals, easy to carry in the field and on-site use.
Technical parameter
Input voltage Three-phase four-wire 3 380 (220) V 50Hz
The output voltage Three-phase four-wire 3 (0 380) / (0 220) Triple semi-digital display, accuracy: level 1
Output current Communication 0 ~ 20A Triple semi-digital display, accuracy: level 1
Maximum output capacity 3 300VA
Three-phase coarse Ambient temperature: 0 360 Move 30 per step
845 Electronics Communications Suppliers
Short on time? Let Electronics Communications sellers contact you.
Single phase standard power supply is suitable for power department, quality control department, research units, institution of higher learning, electric energy meter, power supply management, load control, power quality, reactive power compensation device and production of the enterprise and so on. It can be as single phase voltage source, current source and power source.
Electrical parameters
Electrical parameters
Accuracy class
0.05, 0.1
Power supply
Single phase AC 85-265V, 50 60 Hz
AC Voltage output
Range
57.7V 100 V 220V 380V, Switch automatically max 500V
Current transformer field tester was developed with high-end testing technology, large-scale electronic circuit design and accord with national related protocol . It has solved the problem of big working intensity,trival operation while on-site test of current transformer, voltage transformer. Meanwhile the product has a reliable performance,and the function is strong.
Technical index
Test range: 5A5A~25000A5A or 5A1A~5000A1A
Tested current transformer work scope: 1% 120%
Second load 2.5 VA 300VA, COS 0.8 1.0
Be tested current transformer accuracy range 1.0, 0.5, 0.5 S, 0.2 and 0.2 S
Resistance, admittance measurement errors 5.0%
Measurement range R 0.00 ~20.0 Y 0.000mS~100.0 mS
Power consumption 20 VA
Accuracy level 0.05 S level
Shape dimension mm 460 L 375 W 183H
Weight kg 10
Feature
HCCT-H Current Transformer Field Tester with recursive method to measure current transformer error, as well as potential difference method to measure voltage transformer error function, convenient for carrying out calibration work of field metering device.
HCCT-H Current Transformer Field Tester without using Standard Current Transformer, Current Source, Load Box, Double Adjustable Control Box and Primary cable, using extremely simple test connection and operation to realize the current transformer test, greatly reduce work intensity and improve the work efficiency, convenient to carry out current transformer field test work.
Current Transformer Analyzer is new product created after widely adopt customers advices and deep theoretical study. It is based on the automatic FA Series Transformer Tester General which is produced by our company that is widely acclaimed and applied. The adoption of high-performance DSP and ARM, advanced manufacturing technology ensure a stable and reliable product performance, full-featured, high degree of automation, high efficiency, in the domestic leading level, they are the professional testing equipments for transformer check in power industry.
Single-phase standard power supply is suitable for power department, quality control department, research units, institution of higher learning, electric energy meter, power supply management, load control, power quality, reactive power compensation device and production of the enterprise and so on. It can be as single phase voltage source, current source and power source.
Insulation resistance tester with absorption ratio embedded real-time industrial microcomputer operating system, ultra-thin wire-shaped sheets header with the perfect combination of dot matrix liquid crystal display, the instrument is with a variety of voltage output level (250V,500V,1000V,2500V,5000V,10000V), high capacity, strong anti-interference, the pointer and digital synchronous display, AC-DC dual-use, simple operation, automatic calculation of various insulation index (absorption ratio, polarization index), all measured characteristics with the anti-power-down function .
Microcomputer relay protection tester also known as three-phase microcomputer relay protection tester, three-phase microcomputer relay protection tester is a special power relay protection tester.Three-phase microcomputer relay protection tester has 4 phase voltage 3 phase current output, suitable for various types of relay protection device test.Three-phase microcomputer relay protection tester adopts high speed and high performance digital control processor as control microcomputer, and the software uses double precision algorithm to generate arbitrary high precision waveform of each phase.Because of the integrated structure, each part is closely combined, the data transmission distance is short, and the structure is compact.It overcomes the problem of low number of output waveform points caused by long data communication line and narrow frequency band in the measurement and control instrument directly controlled by laptop computer.
Technical parameter :
AC current output
Phase current output (effective value) 040A
Three merge current output (effective value) 0120A
Phase electric length time allows work value (effective value) 10A
Phase current maximum output power 420VA
Maximum output power at the maximum output of three 900VA
Working time is allowed when the maximum output of the three mesh is output 10s
Frequency range (fundamental) 201000Hz
Harmonics 1 20 times
AC voltage output
Output accuracy Level 0.2
Phase voltage output valid value 0120V
Line voltage output valid value 0210V
Maximum voltage output value 0240V
Phase voltage / line voltage output power 80VA /100VA
Frequency range (fundamental) 201000Hz
Harmonics 1 20 times
volume and weight Dimensions 365*300*165MM
Stand-alone weight 15.5KG
Frequency conversion series resonance test device is designed and manufactured for alternating-current withstand voltage test of Possessing a wider application scope, it is the ideal withstand voltage equipment for prefecture-level, municipal-level and county-level high-voltage test departements as well as power installation and repair & testing engineering units.
Frequency Conversion Series Resonance Test Device
(I) Technical index
1. Rated voltage:
2. Quality factor under full load in test of fire power generator: Q10 (relating to load)
3. Quality factor under full load in cable test: Q 30 (relating to load)
4. Quality factor under full load in test of main transformer: Q 30 (relating to load)
5. GIS, the quality factor under full load in switch test and other tests: Q 50 (relating to load)
6. Input power supply: single phase of 380V
7. Frequency adjustment range: 20Hz 300Hz
8. Accuracy of system measurement: 1.5
9. The unit possesses protective functions, such as over voltage, over current and zero start.
(II) Description for main configuration and technical data of equipment:
1. One set of variable-frequency power supply:
Rated power: 10kVA;
Input voltage: single phrase of 220V or three phase of 380V 10% and 45 65Hz
Output voltage: 0 400V adjustable
Output voltage frequency: 30 300Hz
0.1Hz adjustable stepping
Instability degree of frequency 0.02%
Output current: 0 25A
2. High-voltage resonane reactor (4sets in all): 27kV/1A
Overview
The gas relay calibrator is a tester device that specializes in verification of gas gas relays. The gas relay calibrator is a detection check device for the detection of the Vaste Relay Flow Period Value, Cable Point Value, and Sealing Pressure Value. Gas Relay Calibrator is suitable for more than 90 of Gas Relay checks in .
Gas relay is also known as gas gas relay, is a protective unit in an oil immersion transformer, mounted in an oil pipe under transformer oil pillow. The gas relay detector is a dedicated gas relay pressure release valve calibrator device for the gas relay value, a capacity value, and sealing pressure value, and the gas relay tester uses a microcomputer control technology, and the gas relay tester is detected by detecting a high-precision pressure sensor. When the gas relay tester simulates the internal failure of the transformer, the gas method of the gas relay tester is calculated to calculate the flow rate value to achieve the detection of gas relatives, the Gas protection action value, the gas relay calibrator adopts the fine container combined with the US MCC's micro Press the precision sensor, detect the inside of the gas relay to exclude the liquid volume method to calculate the light gas capacity value
Technical parameter
Portable gas relay calibrator
Protection IP65
Execution standard Compliance with DL T540 1994 standards and IEC
power input 50HZ 220V
Flow speed detection heavy gas 0.1-0.5m s 0.05m s resolution 0.01
0.5-2.5m s 0.1m s resolution 0.1
High pressure wireless phase detector is a dedicated test high-voltage nuclear phase tester based on national power industry standard norms and market demand, and high-voltage nuclear photographic applies to detecting the two-sided circuit breaker of the ring or dual power supply power network closed loop circuit breaker. Whether it is produced in the same phase.
Before the closed loop two power supply, you must perform a nuclear phase, otherwise a short circuit can occur, suitable for the 6KV 220KV transmission line with the electrical core, the sight can reach 200 meters, and the wall can be used, and it has a test function.
Wireless high pressure cores use wireless transmission technology, safe and reliable operation, easy to use, in line with national electric power safety equipment quality supervision and testing standards. Compared with the cable core, it is the main advantage that the lead wire connected to both grids power supply is removed, and the safety is used to improve the security in a manner that is not subject to any terrain and facility architecture.
Technical parameter
Phase difference
Error 5
Frequency accuracy 0.1Hz
The voltage grade measured by this product is 6kv 220kv
Transmission distance of the transmitter and receiving host
The digital millisecond tape RS232 communication interface is widely used in electric power, electronics, telecommunications, railway, transportation and electromechanical, mechanical and other departments. It is used to measure the electromagnetic contact, remote device, and automatic device various action time, action intervals, machinery. The contacts, contacts, power switch main contacts, time, three phases, interval, tensile interval, tensilate, slightly separation, interval between closures, hierarchics, tensile gain machine B contact, and Active pulse lines such as various band switches, lock switches, limit switches, and universal conversion switches are also available for sports, and measure the speed of the A point to the B point.
Technical parameter
Measuring range 0.0001 999.9999 seconds
Timing accuracy 0. 01 2 words
power supply AC 220V 10 50Hz
power 5W
input signal Mechanical air contact or electrical signal 5 20V
Reset method Manual or software clearing
Relative humidity 80 RH
Dimensions 195 175 80
weight 1.5 kg
Intelligent digital millisecond 1Intelligent digital millisecond
Insulating boots and gloves withstand voltage device is a power frequency power supply with low voltage working voltage of 220V/50Hz for insulating boots and gloves. According to the principle of electromagnetic induction, the input voltage is changed to the minimum value required for the test. high pressure. Insulating boots (gloves) withstand voltage test device generally consists of a special dedicated test box, an intelligent power frequency withstand voltage console, and a power frequency withstand voltage test transformer.
A special water tank can be customized according to needs to test 6-8 insulated boots or 6 insulated gloves at a time, and display the leakage current of the insulated boots or insulated gloves at the same time. The intelligent power frequency withstand voltage console is equipped with overcurrent protection and zero protection. Time protection and alarm function. The preventive voltage resistance test device for insulating boots and gloves is a special product developed and produced according to the needs of users according to the test procedures of insulating boots (gloves).
The selection has an automatic boost (buck) function, automatically reads the leakage current of each test product, the whole process is automatically completed, and the test data is automatically printed, which effectively solves the previous non-standard test methods, thereby simplifying .Simplifies the test procedure and improves the test speed. More reliable identification of parameters such as leakage current and power frequency withstand voltage of insulating boots (gloves). To ensure the safety of test personnel, it is an ideal pre-treatment of insulating boots (gloves) to protect power frequency withstand voltage test equipment.
Technical Parameters
Input voltage AC220V 50 Hz
Output voltage 0~30kV
Capacity 3kVA
Test number 3 pairs each time
Quality Gloves (insulating boots) test car: 80kg; power frequency withstand voltage test bench: 70kg
Current transformer volt-ampere characteristic tester Only need to set the test voltage, current and step, the device will boost and trace voltage current characteristic test curve automatically, save the cumbersome labor of manual pressure regulation, artificial record, tracing curves, and so. Quick, simple and convenient.
I can not only test CT/PT DC resistance, volt-ampere characteristics, ratio and polarity, 10% error curve, angle difference and ratio difference, but also test secondary load of transformer, CT current test and PT AC withstand voltage test.
CT ratio not only supports traditional current method but also voltage method, so it can meet the test of CT in casing CT and GIS.
Volt-ampere characteristic test single machine output voltage 0-2500V, current 0-20A, can meet most of the transformer volt-ampere characteristic test.
220V single power input and avoids the risk of using 380V.
Current transformer volt-ampere characteristic tester
Frequency conversion series resonance test device is designed and manufactured for alternating-current withstand voltage test of Possessing a wider application scope, it is the ideal withstand voltage equipment for prefecture-level, municipal-level and county-level high-voltage test departements as well as power installation and repair & testing engineering units.
Frequency Conversion Series Resonance Test Device
Technical index
Rated voltage
Quality factor under full load in test of fire power generator Q 10 relating to load
Quality factor under full load in cable test Q 30 relating to load
Quality factor under full load in test of main transformer: Q 30 relating to load
GIS, the quality factor under full load in switch test and other tests Q 50 relating to load
Input power supply single phase of 380V
Frequency adjustment range 20Hz 300Hz
Accuracy of system measurement 1.5
The unit possesses protective functions, such as over voltage, over current and zero start.
Description for main configuration and technical data of equipment
One set of variable-frequency power supply
Rated power 10kVA;
Input voltage single phrase of 220V or three phase of 380V 10 and 45 65Hz
Infrared Thermometers Industrial Gloves Electric Power Generators Medical Thermometers Television Police & Military Uniforms Scientific Instruments Medical Face Masks Uniforms Furniture Medical Supplies & Disposable Iron Medical Coveralls Teak Furniture Army & Police Equipment Medical Clothing Gloves Medical Gloves Steel Tubes Touch Screen/LCD Monitors Garden & Outdoor Furniture Computer Monitors
.