Size: length 2.9cm x width 1.1cm
Blinking or non blinking
LED balloon light can be used for following points:
1. Light up your balloons as balloon lights.
2. Decorating your flowers
3. Light up your swimming pool
4. Light up your vase
5. Light up your fish case
5. Light up your bathtub
6. Use as a flashlights
7. Light up your yard
8. Light up any item you want to make your life fun.
The material of composite rivet's working layer is more flexible to choose than the solid precious metal rivet's, even though the precious alloy material has excellent electrical contact property. Rivet contact is suitable for the continuous automatic production of riveting and processing. It doesn't other processing technique(such as electroplating, welding, etc). So, it not only simplified the manufacturing process of contact component, improve the productivity and lower the cost, but also increase the assembling precision and reliability of the component.
Vacuum package with dryer or as customer request
1104 Electronics Communications Suppliers
Short on time? Let Electronics Communications sellers contact you.
MW MY Miniature Circuit Breaker
Application
MW MY series circuit breaker is used in lighting distribution system or motor distribution system for protection overload and short-circuits in the system. The product is neoteric in structure, reliable and excellent in performance. It has high breaking capacity, can trip quickly, and its case and items are adopted by high fire-resistant and shockproof plastic. The product, with long life, is mainly used in AC 50HZ/60HZ single-pole 230V or two, three, four poles 400V circuit for overload and short-circuit protection as well as for infrequent on-and-off switching electric equipment and lighting circuit in normal case. The products comply with IEC 60898.
Solid river is one of the most popular rivet-type contacts used in low-voltage appliances which has better electrical and thermal conductivity, low resistivity and easy to process.
Main material:
Cu, pure silver, agcdo, agni, agsno2, agcu, agzno, etc.
Agni features:
(1) agni contact material contains 10% to 40% ni
(2) produced by powder metallurgical production, with low and stable contact resistance, high hardness and mechanical strength
(3) material transfer in case of dc is very low
(4) high electrical and thermal conductivity
(5) with very low arc erosion. On making higher current, normally asymmetric pairs with ag contact materials are applied
(6) wire of solid and composite rivets produced by powder sintering-extruding method
Inner package: vaccum plastic bag outside package:carton packing
Features: Ceiling and Suspended Lamps, general illumination
Installation & maintenance: suspension wire, suspender or ceiling mounting, generally we provide 1.0m electrical wire & suspension wires and they can be customized in different length accordance with customerí»s requirement.
Product description:
Terse & generous appearance design with elegant.
Lamp-body adopts extruded forming aluminum alloy(6063).
Can be connected in linear rows for use with the accessories along with the lamp.
Using PMMA diffuser with symmetrical light distribution, can eliminate glare, the illuminating performance is very good.
Electronic ballast: XIONGYU, OSRAM, PHILIPS, HONGLIDA
Applicable for office building, large shopping mall, teaching room, library, airport, waiting room etc..
Model L*W*H(mm) Body Material Color
MX607-3*35W 1500*265*66 Aluminum alloy Silver
MX607-3*28W 1200*265*66 Aluminum alloy Silver
MX607-2*35W 1500*172*66 Aluminum alloy Silver
MX607-2*28W 1200*172*66 Aluminum alloy Silver
MX607-4*14W 605*605*66 Aluminum alloy Silver
1.Low price and high reliability
2.105íµ output capacitor
3.AC input power suitable for the world
4.High efficiency and low operation temperature
5.Soft-start current can reduce the AC input impact effectively
6.With short-circuit and overload protection
7.Compact size, light weight
8.100% full-load burning test
9.Installed with EMI filter, minimum wave
Model
Specification DR-240-24 DR-240-48
DC output voltage 24V 48V
Output voltage error (Note2) % 1%
Rated output current 10A 5A
Output current rage 0-10A 0-5A
Wave and noise(Note3) 80mVp-p 150mVp-p
Inlet stability(Note4) í+0.5% í+0.5%
Load stability(Note5) í+1% í+1%
DC output power 240W 240W
Efficiency 84% 85%
Adjustable range for DC voltage 21.6-26.4V 43.2-52.8V
AC input voltage range 88í½264VAC 47í½63HZ;120í½370VDC
Input current 3.5A/115V 1.8A/230V
AC impulse current Cold-start current 30A/115V 50A/230V
Leakage current <3.5mA/240VAC
Overload protection 105%í½150% Typeú¦current limiting; Reset: auto recovery
Over-voltage protection 30-34V 54-60V
High-temperature protection 100íµí+5íµ(TSW1)
Temperature coefficient í+0.03%íµ(0í½50íµ)
Setup rise hold up time 800ms,40ms,20ms/230VAC 800ms,40ms,20ms/115VAC
Vibration 10í½500Hz,2G 10min./1cycle,Period for 60min,Each axes
Withstand voltage Input and output intervalú¦3KVACú¼Input and enclosureú¦1.5KVACú¼Output and enclosureú¦0.5KVAC
Isolation resistance Input and output intervalú¼Input and enclosureú¼Output and enclosureú¦500VAC/100M Ohms
Working temperature and humidity -10íµí½+50íµú¼20%í½90%RH
Store temperature and humidity -20íµí½+85íµ,10%í½95RH
Overall dimension 125.2*125.2*100mm
Weight 1.2Kgs 20PCS/14.4KG/1.2CUFT
Safety standards Meet UL1012
EMC standards Meet Part 15J conduction class B
Note:1.The testing condition for the parameter above is:230VAC input, rated load,25íµ 70%Rh,Humidity
2.Error,include the setting error, line stability and load stability.(Note:5)
3.Wave test:adoptingí¦A12í¦double wire for 20MHz,and 0.1uF&uF capacitor short-circuit for interrupting
4.Inlet voltage stability test: when is over load, the lowest voltage of inlet is representative to the highest voltage.
5.Load stability test: The load is from 0% to 100%,others 60%.
6.C2íó3íó11must be knocked down.
1.Low price and high reliability
2.105íµ output capacitor
3.AC input power suitable for the world
4.High efficiency and low operation temperature
5.Soft-start current can reduce the AC input impact effectively
6.With short-circuit and overload protection
7.Compact size, light weight
8.100% full-load burning test
9.Installed with EMI filter, minimum wave
Model
Specification DR-120-12 DR-120-24 DR-120-48
DC output voltage 12V 24V 48V
Output voltage error (Note2) 2% 1%
Rated output current 10A 5A 2.5A
Output current rage 0-10A 0-5A 0-2.5A
Wave and noise(Note3) 80mVp-p 80mVp-p 100mVp-p
Inlet stability(Note4) í+0.5% í+0.5% í+0.5%
Load stability (Note5) í+1% í+1% í+1%
DC output power 120W 120W 120W
Efficiency 80% 84% 85%
Adjustable range for DC voltage 10.8-13.2V 21.6-26.4V 43.2-52.8V
AC input voltage range 88í½132VAC/176-264 47í½63HZ;248í½370VDC
Input current 3.3A/115V 2A/230V
AC impulse current Cold-start current 30A/115V 60A/230V
Leakage current <3.5mA/240VAC
Overload protection 105%í½150% Typeú¦current limiting; Reset: auto recovery
Over-voltage protection 15-16V 29-33V 58-62V
High-temperature protection 85íµí+5íµ(TSW1) 90íµí+5íµ(TSW1) 90íµí+5íµ(TSW1)
Temperature coefficient í+0.03%íµ(0í½50íµ)
Setup rise hold up time 500ms,70ms,30ms/230VAC
Vibration 10í½500Hz,2G 10min./1cycle,Period for 60min,Each axes
Withstand voltage Input and output intervalú¦3KVACú¼Input and enclosureú¦1.5KVACú¼Output and enclosureú¦0.5KVAC
Isolation resistance Input and output intervalú¼Input and enclosureú¼Output and enclosureú¦500VAC/100M Ohms
Working temperature and humidity -10íµí½+50íµú¼20%í½90%RH
Store temperature and humidity -20íµí½+85íµ,10%í½95RH
Overall dimension 65.5*125.2*100mm
Weight 0.8Kgs 20PCS/16KG/1.1CUFT
Safety standards Meet UL1012
EMC standards Meet FCC Part 15J Conduction class B
Note:1.The testing condition for the parameter above is:230VAC input, rated load,25íµ 70%Rh,Humidity
2.Error,include the setting error, line stability and load stability.(Note:5)
3.Wave test:adoptingí¦A12í¦double wire for 20MHz,and 0.1uF&uF capacitor short-circuit for interrupting
4.Inlet voltage stability test: when is over load, the lowest voltage of inlet is representative to the highest voltage.
5.Load stability test: The load is from 0% to 100%,others 60%.
6.C2íó3íó11must be knocked down.
1.Low price and high reliability
2.105íµ output capacitor
3.AC input power suitable for the world
4.High efficiency and low operation temperature
5.Soft-start current can reduce the AC input impact effectively
6.With short-circuit and overload protection
7.Compact size, light weight
8.100% full-load burning test
9.Installed with EMI filter, minimum wave
Model
Specification DR-75-12 DR-75-24 DR-75-48
DC output voltage 5V 12V 15V
Output voltage error (Note2) í+2% í+1% í+1%
Rated output current 6.3A 3.2A 1.6A
Output current rage 0-6.3A 0-3.2A 0-1.6A
Wave and noise(Note3) 100mVp-p 150mVp-p 240mVp-p
Inlet stability(Note4) í+0.5% í+0.5% í+0.5%
Load stability(Note5) í+1% í+1% í+1%
DC output power 75.6W 76.8W 76.8W
Efficiency 76% 80% 81%
Adjustable range for DC voltage 10.8-13.2V 21.6-26.4V 43.2-52.8V
AC input voltage range 85í½264VAC/47í½63HZ;120í½370VDC
Input current 1.8A/115V 0.90A/230V
AC impulse current Cold-start current 30A/115V 60A/230V
Leakage current <3.5mA/240VAC
Overload protection 105%í½150% Typeú¦PULSING HICCUP SHUTDOWN Reset: auto recovery
Over-voltage protection 10.8-13.2V 27.6-32.4V 58-62V
High-temperature protection í¡í¡
Temperature coefficient í+0.03%íµ(0í½50íµ)
Setup rise hold up time 1000ms,60ms,50ms/230VAC
Vibration 10í½500Hz,2G 10min./1cycle,Period for 60min,Each axes
Withstand voltage Input and output intervalú¦3KVACú¼Input and enclosureú¦1.5KVACú¼Output and enclosureú¦0.5KVAC
Isolation resistance Input and output intervalú¼Input and enclosureú¼Output and enclosureú¦500VAC/100M Ohms
Working temperature and humidity -10íµí½+50íµú¼20%í½90%RH
Store temperature and humidity -20íµí½+85íµ,10%í½95RH
Overall dimension 55.5*125.2*100mm
Weight 0.55Kgs 20PCS/14KG/1.1CUFT
Safety standards Meet UL1012
EMC standards Meet Part 15J conduction class B
Note:1.The testing condition for the parameter above is:230VAC input, rated load,25íµ 70%Rh,Humidity
2.Error,include the setting error, line stability and load stability.(Note:5)
3.Wave test:adoptingí¦A12í¦double wire for 20MHz,and 0.1uF&uF capacitor short-circuit for interrupting
4.Inlet voltage stability test: when is over load, the lowest voltage of inlet is representative to the highest voltage.
5.Load stability test: The load is from 0% to 100%,others 60%.
6.C2íó3íó11must be knocked down.
1.Low price and high reliability
2.105íµ output capacitor
3.AC input power suitable for the world
4.High efficiency and low operation temperature
5.Soft-start current can reduce the AC input impact effectively
6.With short-circuit and overload protection
7.Compact size, light weight
8.100% full-load burning test
9.Installed with EMI filter, minimum wave
Model
Specification DR-45-5 DR-45-12 DR-45-15 DR-45-24
DC output voltage 5V 12V 15V 24V
Output voltage error (Note2) % í+1% í+1% í+1%
Rated output current 5A 3.5A 2.8A 2A
Output current rage 0-5A 0-3.5A 0-2.8A 0-2A
Wave and noise(Note3) 100mVp-p 200mVp-p 240mVp-p 480mVp-p
Inlet stability(Note4) í+1% í+1% í+1% í+1%
Load stability(Note5) í+1% í+1% í+1% í+1%
DC output power 25W 42W 42W 48W
Efficiency 72% 77% 77% 80%
Adjustable range for DC voltage 4.75-5.5V 10.8-13.2V 13.5-16.5V 21.6-26.4V
AC input voltage range 85í½264VAC/47í½63HZ;120í½370VDC
Input current 1.5A/115V 0.75A/230V
AC impulse current Cold-start current 30A/115V 60A/230V
Leakage current <1mA/240VAC
Overload protection 105%í½150% Typeú¦current limiting .Reset: auto recovery
Over-voltage protection 5.75-6.75V/13.8-16.2V/17.25-20.25V/27.6-32.4V
High-temperature protection í¡í¡
Temperature coefficient í+0.03%íµ(0í½50íµ)
Setup rise hold up time 800ms,60ms,50ms/230VAC
Vibration 10í½500Hz,2G 10min./1cycle,Period for 60min,Each axes
Withstand voltage Input and output intervalú¦3KVACú¼Input and enclosureú¦1.5KVACú¼Output and enclosureú¦0.5KVAC
Isolation resistance Input and output intervalú¼Input and enclosureú¼Output and enclosureú¦500VAC/100M Ohms
Working temperature and humidity -10íµí½+50íµú¼20%í½90%RH
Store temperature and humidity -20íµí½+85íµ,10%í½95RH
Overall dimension 93*78*67mm
Weight 0.31Kgs 48PCS/14.8KG/1.3CUFT
Safety standards Meet UL1012
EMC standards Meet FCC Part 15J Conduction Class B
Note:1.The testing condition for the parameter above is:230VAC input, rated load,25íµ 70%Rh,Humidity
2. Error,include the setting error, line stability and load stability.(Note:5)
3. Wave test:adoptingí¦A12í¦double wire for 20MHz,and 0.1uF&uF capacitor short-circuit for interrupting
4. Inlet voltage stability test: when is over load, the lowest voltage of inlet is representative to the highest voltage.
5. Load stability test: The load is from 0% to 100%,others 60%.
6. C2íó3íó11must be knocked down.
We are a professional Chinese manufacturer of HID xenon lamp company.
Good quality,best service,reasonble price,fast deliver is our faith
We can supply you with many models of high quality HID xenon lamp, such as H1, H3, H4(H/X), H4(H/L), H4(F/N), H7, 9004, 9004(H/L), 9005, 9006, 9007 and so on. The ballast is GF-34,GF-89,GF-100 and so on. The color temperature is from4300k to 12000k.