DR-45/24
1.Low price and high reliability
2.105íµ output capacitor
3.AC input power suitable for the world
4.High efficiency and low operation temperature
5.Soft-start current can reduce the AC input impact effectively
6.With short-circuit and overload protection
7.Compact size, light weight
8.100% full-load burning test
9.Installed with EMI filter, minimum wave
Model
Specification DR-45-5 DR-45-12 DR-45-15 DR-45-24
DC output voltage 5V 12V 15V 24V
Output voltage error (Note2) % í+1% í+1% í+1%
Rated output current 5A 3.5A 2.8A 2A
Output current rage 0-5A 0-3.5A 0-2.8A 0-2A
Wave and noise(Note3) 100mVp-p 200mVp-p 240mVp-p 480mVp-p
Inlet stability(Note4) í+1% í+1% í+1% í+1%
Load stability(Note5) í+1% í+1% í+1% í+1%
DC output power 25W 42W 42W 48W
Efficiency 72% 77% 77% 80%
Adjustable range for DC voltage 4.75-5.5V 10.8-13.2V 13.5-16.5V 21.6-26.4V
AC input voltage range 85í½264VAC/47í½63HZ;120í½370VDC
Input current 1.5A/115V 0.75A/230V
AC impulse current Cold-start current 30A/115V 60A/230V
Leakage current <1mA/240VAC
Overload protection 105%í½150% Typeú¦current limiting .Reset: auto recovery
Over-voltage protection 5.75-6.75V/13.8-16.2V/17.25-20.25V/27.6-32.4V
High-temperature protection í¡í¡
Temperature coefficient í+0.03%íµ(0í½50íµ)
Setup rise hold up time 800ms,60ms,50ms/230VAC
Vibration 10í½500Hz,2G 10min./1cycle,Period for 60min,Each axes
Withstand voltage Input and output intervalú¦3KVACú¼Input and enclosureú¦1.5KVACú¼Output and enclosureú¦0.5KVAC
Isolation resistance Input and output intervalú¼Input and enclosureú¼Output and enclosureú¦500VAC/100M Ohms
Working temperature and humidity -10íµí½+50íµú¼20%í½90%RH
Store temperature and humidity -20íµí½+85íµ,10%í½95RH
Overall dimension 93*78*67mm
Weight 0.31Kgs 48PCS/14.8KG/1.3CUFT
Safety standards Meet UL1012
EMC standards Meet FCC Part 15J Conduction Class B
Note:1.The testing condition for the parameter above is:230VAC input, rated load,25íµ 70%Rh,Humidity
2. Error,include the setting error, line stability and load stability.(Note:5)
3. Wave test:adoptingí¦A12í¦double wire for 20MHz,and 0.1uF&uF capacitor short-circuit for interrupting
4. Inlet voltage stability test: when is over load, the lowest voltage of inlet is representative to the highest voltage.
5. Load stability test: The load is from 0% to 100%,others 60%.
6. C2íó3íó11must be knocked down.