Please click here to check who's online and chat with them.

Find Verified Water Meter Suppliers, Manufacturers and Wholesalers

Top Supplier Cities : Shanghai   Shenzhen   -  
Apr-27-07
 Inquire Now  
Model KFP Pressure indicating Controllers indicate and control a process variable by converting its pressure change into mechanical displacement of a bellows or a spiral pressure receiving element.
Indicating transmitters and indicating transmitting controllers also are available as well as indicating controllers. The controllers are available either in the local type to set the set-point value with the knob on the instrument or in the cascade type (remote type) to set the set-point value with a pneumatic signal.
**A wide variety of measuring elements and control mechanisms are available to meet various applications.
**A pneumatic circuit board and a heat-resistant weatherproof sturdy hard case are used, thereby greatly improving the durability and reliability.
**The pneumatic circuit board system allows to readily add or eliminate control mechanisms and units, thereby enhancing the system modification and expansion flexibility.
**Interchangeable parts are used to the maximum practicable extent, thereby reducing the number of parts to be kept in stock.
**A balancing weight and a pulsation damping spiral (optional) are employed, thereby making the instruments highly resistant against mechanical vibration and process pulsation.
Apr-27-07
 Inquire Now  
Model KFK Pressure indicating Controllers (adjustable range type) indicate and control a process variable by converting its pressure into mechanical displacement of a bellows or a spiral pressure receiving element.
Indicating transmitters and indicating transmitting controllers also are available as well as indicating controllers. The controllers are available either in the local type to set the set-point value with the knob on the instrument or in the cascade type (remote type) to set the set-point value with a pneumatic signal.
**A wide variety of measuring elements and control mechanisms are available to meet various applications.
**A pneumatic circuit board and a heat-resistant weatherproof sturdy hard case are used, thereby greatly improving the durability and reliability.
**The pneumatic circuit board system allows to readily add or eliminate control mechanisms and units, thereby enhancing the system modification and expansion flexibility.
**Interchangeable parts are used to the maximum practicable extent, thereby reducing the number of parts to be kept in stock.
**The detecting section is identical with that of the pressure transmitter of PREX3000 Pneumatic Transmitter Series.
Apr-27-07
 Inquire Now  
The KF Series of Field Mounted Indicating Controllers, which the special manufacturing techniques is introduced from Japanese Yamatak-Honeywell Co., Ltd, provides both application flexibility and instrumentation savings by employing a common type of indicating control section in each instrument. All process variables, such as temperature, pressure, level and flow, can be measured and controlled by the same type of instrument. The difference is only in the detector. Thus, the KF Series provides model simplicity and uniformity, and requires very little in the way of maintenance.
The KF Series comprises not only Indicating Transmitters but also Indicating Transmitting Controllers. They are united in structure, and combined in functions, complete in varieties and specifications with stable performance, high precision, strong anti-interference ability, high reliability, and are easy to mount and maintain. They are intrinsically safe and explosion-proof, able to drive the pneumatic performance mechanism directly, so they have been generally well accepted and trusted by domestic and foreign customers.
Apr-27-07
 Inquire Now  
Model KFT Temperature Indicating Controllers indicate and control a process variable by converting its temperature change into mechanical displacement of a bellows through change in expansion of liquid-fill by temperature or change in gas-fill pres-sure by temperature.
Indicating transmitters and indicating transmitting controllers also are available as well as indicating controllers. The controllers are available either in the local type to set the set-point value with the knob on the instrument or in the cascade type(remote type) to set the set-point value with a pneumatic set-point signal.
**A wide variety of measuring elements and control mechanisms are available to meet various applications.
**A pneumatic circuit board and a heat-resistant weatherproof sturdy case are used , thereby greatly improving the durability and reliability.
**The pneumatic circuit board system allows to readily add or eliminate control mechanisms and units, thereby enhancing the system modification and expansion flexibility.
**Interchangeable parts are used to the maximum practicable extent, thereby reducing the number of parts to be kept in stock.
**A bellows type pressure receiving element, which provides a larger torque and a higher resistance against vibration, is employed.
**A Compensation mechanisms for ambient temperature change is incorporated.
Sep-21-26
559 Water Meter Suppliers
Short on time? Let Water Meter sellers contact you.
Jul-30-26
 Inquire Now  
80-680
Water level meter can do manual inspection which can be used to observe the water level inside water wells, boreholes, water level pipes, etc.

The advantage is water level meter can check the water level in an accurate, fast, and simple way with its sensitive sensor.

There are 2 types for Naijiu Water Level Meter: ABS material blue & Ion blue, length from 30m-800m, we can do customization according to the customer requirements.

Main Parts
Probe
Material: Stainless Steel

Steel ruler
Material: Steel & Plastic

Receiving system
It consist of Sounder (beep) & indicator light

Specification For 30m-500m, exceed 500m need to do customization.
Minimum Reading(mm): 1.0
Repetitive Reading(mm): �±2.0
Operation Voltage(V): DC=9

Operation Steps
1. Power On
2. Probe Inside Well
3. Probe Move Down Slowly
4. Probe Touch Water
5. Sounder Beep

Notes
Turn off immediately & Remove the battery (9V) after used.
Probe and the Steel ruler must be clean and neat after used.
Donâ??t bend the measuring cable to avoid the cable to be damaged.
Storage Temp: - 10 ~ +40 â?? . Dry & Ventilated , room temp should below 80% with non-corrosive gas
Oct-09-26
 Inquire Now  
Sanitary Vs. Standard Electromagnetic Flow Meters
d and beverage processing. Choosing between sanitary and standard models can significantly impact cost, compliance, and operational efficiency. This guide helps you select the right flow meter for your facility, whether you need an electromagnetic flow meter for beer, pure water, or jam, or a food grade flow meter for dairy and beer.

Key Requirements for Food-Grade Flow Meters
Food and beverage applications require hygienic electromagnetic flow meters that meet strict hygiene and safety standards:

Hygienic Design

3-A Sanitary Certification: Ensures smooth surfaces (â?¤0.8 �µm roughness) with no crevices to prevent bacterial growth.
FDA-Compliant Materials: PTFE or PFA liners and 316L stainless steel electrodes prevent contamination.
CIP/SIP Compatibility: Withstands high-temperature caustic cleaning cycles.
Material Safety

Non-toxic, non-absorbent materials.
No lubricants or seals that could harbor pathogens.
Performance in Low-Conductivity Fluids

Advanced models with â??Signal Boostâ?? technology can measure low-conductivity liquids like milk (~500 �µS/cm).
Ideal for applications requiring a conductivity meter for food and beverage or a food grade electromagnetic flow meter.
Oct-09-26

Liquid Mass Flow Meter, SHLEES

$100 - $1.00K / Set (FOB)
MOQ: Not Specified
 Inquire Now  
liquid mass flow meter

Coriolis Mass Flowmeter (abbreviated as CMF) is a high â?? precision flow instrument that directly measures the mass flow of fluids. It operates based on the principle of the Coriolis Effect. It can not only measure mass flow but also simultaneously obtain parameters such as density and temperature, and is widely used in fields such as petrochemical, food and medicine, and energy metering.

Working Principle
Coriolis Effect
When the fluid flows through the vibrating measuring tube, a Coriolis Force is generated, causing the measuring tube to undergo a slight deformation. By detecting this deformation, the mass flow of the fluid can be calculated.



Measuring tube vibration: The electromagnetic drive makes the measuring tube vibrate at its natural frequency.
Phase difference detection: When the fluid is flowing, the vibration phase difference between the inlet and the outlet is proportional to the mass flow.
Density calculation: The vibration frequency of the measuring tube is related to the fluid density, enabling synchronous density calculation.
Oct-08-26

Mag7000 Flow Meter, SHLEES

$100 - $1.00K / Set (FOB)
MOQ: Not Specified
 Inquire Now  
MAG7000 Flow Meter
https://www.leestransmitter.com/products/7000electromagnetic-flowmeter/

An electromagnetic flow meter (mag meter) measures the flow rate of conductive liquids using Faradayâ??s law of electromagnetic induction. When a conductive fluid flows through a magnetic field, it generates a voltage proportional to the flow velocity, which the meter converts into a flow measurement.

Key Features of MAG7000 Flow Meter
Non-intrusive measurement â?? No moving parts, reducing maintenance.
High accuracy â?? Typically �±0.5% of flow rate.
Suitable for various liquids â?? Works with water, slurries, acids, bases, and beverages.
Bidirectional measurement â?? Can measure flow in both directions.
Wide pipe sizes â?? Available from small to very large pipelines.
Selection of installation site
The measuring tube must be fully filled with medium at all times â?? electromagnetic flowmeters cannot operate normally when the tube is not full or empty.
1) Select a straight pipe section filled with liquid, such as a vertical section of the pipeline (the flow direction is preferably from bottom to top) or a horizontal pipe filled with liquid (the lowest point of the entire pipeline is the Xuan). During the installation and measurement process, non-full pipe conditions must not occur.
2) The measurement position should be selected at a location greater than 5D upstream of the flowmeter and a straight pipe section of 3D downstream.
3) The measurement points should be selected as far away as possible from pumps, valves and other equipment to avoid their interference with the measurement.

4)The measurement points should be selected as far away as possible from large radio frequency, strong magnetic fields, strong vibration interference sources, etc.
Jun-25-22
Jan-27-21
Dec-17-20
Supplier From China
 Inquire Now
Dec-15-20
Supplier From Ningbo, China
 Inquire Now
Dec-31-19
Supplier From Shanghai, Shanghai, China
 Inquire Now
Dec-31-05
Supplier From Chongqing, China
 Inquire Now
Apr-11-06
Supplier From Zhuhai, China
 Inquire Now
Jul-25-06
Supplier From Ningbo, Zhejiang, China
 Inquire Now
Sep-22-06
Supplier From Ningbo, Zhejiang, China
 Inquire Now
Sep-25-06
Supplier From Ningbo, Zhejiang, China
 Inquire Now
Jan-29-07
Supplier From Dalian, Liaoning, China
 Inquire Now
559 Water Meter Suppliers
Short on time? Let Water Meter sellers contact you.
See what buyers and suppliers are discussing in Water Meter import export community