Please click here to check who's online and chat with them.

Find Verified Electric Circuit Breakers Suppliers, Manufacturers and Wholesalers

Top Supplier Cities : Shenzhen   Guangzhou   Dongguan  
Jun-28-13
 
Product Feature
Model: EBS1B-125 MCB
Standard: IEC 60947-2
Rated current In (A): 32, 40, 50, 63, 80, 100, 125
Rated voltage Ue (V):230/400
Poles:1P, 2P, 3P, 4P
Rated insulation voltage Ui (V): 500
Rated impulse withstand voltage (V): 6000
Rated breaking capacity: 10kA
Rated frequency: 50/60 Hz
Trip characteristic:B: (3~5)
C: (5~10)
D: (10~20)
Thermal operating limit: (1.13~1.45)
Mechanical life: 20 000
Electrical life: 4000
Mount: on 35mm DIN rail

Packaging
Standard export carton
Jun-28-13
 
Product Description
Residual current circuit breaker RCCB
Rated current: 25A, 32A, 40A,50A,63A,80A,100A
Rated sensitivity: 10mA, 30mA, 100mA,300mA
Product Feature
Feature (EBS6R Residual current circuit breaker )
1. Electro-magnetic release, voltage independent
2. High ability of withstanding short circuit current
Connection ( EBS6R RCCB )
Type of terminal: Lug type and pin type
Cables up to 35mm2
Product Specification/Models
Model: EBS6R RCCB ( Residual current circuit breaker )
Standard: IEC61008-1
Rated current In (A): 20A, 25A, 32A, 40A, 50A, 63A, 80A, 100A
Rated voltage Ue (V): 2 poles: 230VAC
4 poles: 230/400VAC
Poles: 2P, 4P

Standard export carton
Feb-09-12
 
Characteristics:
Model: EBS9G-63
Standard: IEC 60947-3
Rated current In (A): 16, 25, 40, 63
Rated voltage Ue (V): 230/400
Poles: 1P, 2P, 3P, 4P
Rated insulation voltage Ui (V): 690
Rated frequency: 50/60 Hz
Mechanical life: 8500
Electrical life: 1500
Mount: On 35mm DIN rail.


The Gross weight 14kg
The dimension 46.5*23.5*17 cm
M.O.Q 500pcs (Samples Excepted)
Payment term T/T, L/C,D/P,O.A
Delivery time Usually 25 days (Negotiable for different order quantity)
Promote the products with our own brand (As one of our agents in your market)
Promote the products with neutral packing.
Feb-09-12
 
Characteristics:
Standard: IEC60898
Rated current In (A): 1,2,3,4,6,10,13,16,20,25,32,40,50,63
Rated voltage Ue (V): 230/400
Poles: 1P, 1P+N, 2P, 3P, 3P+N4P
Rated insulation voltage Ui (V): 500
Rated impulse withstand voltage (V): 6000
Rated breaking capacity: 10KA
Rated frequency: 50/60Hz
Trip curve: B, C, D
Thermal operating limit: (1.13~1.45)¡ÁIn
Energy limiting cass: 3
Mechanical lfe: 20 000
Electrical lfe: 4000
Mount: on 35mm DIN rail.


The Gross weight 14kg
The dimension 46.5*23.5*17 cm
M.O.Q 500pcs (Samples Excepted)
Payment term T/T, L/C,D/P,O.A
Delivery time Usually 25 days (Negotiable for different order quantity)
Promote the products with our own brand (As one of our agents in your market)
Promote the products with neutral packing.
Jan-20-10
 
SG2008 Automatic 12kV Capacitance & Dissipation Factor Test Set is designed to measure dissipation (Dielectric Loss Angle tgª-) or power factor (cosª+) in heavy electromagnetic interference environment such as in power plants or substations. Also it can be used in laboratory for high accurate test. The test set is all-in-one structure: including precision digital bridge, 12kV/200mA frequency conversion power unit, reference capacitor (CN), and other electronic circuits. An external power supply can expand the test range. True portability is realized by the lightweight. Simple usage is realized by the full automation. High performance is realized by the digital process.

We can also provide the professional solutions and equipments for: withstanding voltage testing, c & tan-delta (power factor) testing, partial discharge (PD) testing and impulse voltage testing.
35 Electric Circuit Breakers Suppliers
Short on time? Let Electric Circuit Breakers sellers contact you.
Sep-06-08
 
Mainly used in the low voltage distribution switchboard to control and protect power distribution systerm. Its technical index reaches the international advanced standard of that kind of products in 1990s and conforms to criteria for low voltage breaker in iec60947-2
Jul-02-08
 
CHZ series vacuum auto-recloser utilizes the model ZW7-40.5 circuit breaker and high-reliable MGK intelligent controller. The auto-recloser is designed mainly applying on the medium-voltage overhead distribution lines as well as substations, it is used to make & break the load current, overload current and short-circuit current, also auto-reclosing up to three times.

200~400KG
Aug-29-07
 
Circuit breakers

Lw-252 high voltage sf6 circuit breaker type
Lw8a-40.5 outdoor porcelain post hv sf6 circuit breaker
Lw36-126 high voltage sf6 circuit breaker
Zn28-12 series indoor ac medium-voltage vacuum circuit breaker
Zn63a-12 series indoor ac medium-voltage vacuum circuit breaker
Nv1-24 series indoor ac high-voltage vacuum circuit breaker
252kv gis
Lw3-12 outdoor ac medium-voltage sf6 circuit breaker
Zw8-12 series outdoor ac medium-voltage vacuum circuit breaker
Zw8-12(z) series outdoor intelligent ac mv vacuum circuit breaker
Zw32-12 outdoor ac hv vacuum circuit breaker
Apr-06-07
 
Circuit breaker
May-18-23

Mcb

$0.90
MOQ: Not Specified
 
MCB have short circuit protection, overload protection, and isolation Function
Model:DZ47s 1P C type 1A
rated current :1A
breaking capacity:6kA
May-18-23

Mcb

$0.90
MOQ: Not Specified
 
MCB have short circuit protection, overload protection, and isolation function
Model:DZ47s 1P C type 16A
May-16-23

Mcb

$888.89K
MOQ: Not Specified
 
DZ47-125
Poles:2P
Rated current:100A
Breaking capacity:10KA
Feb-09-12
Supplier From Shanghai, China
May-08-12
Supplier From Shanghai, China
Sep-06-08
Supplier From Shanghai, Shagnhai, China
Dec-14-06
Supplier From Shanghai, China
Nov-22-06
Supplier From Shanghai, China
Dec-21-20
Supplier From Shanghai, Qingpu, China
Aug-12-06
Supplier From Shanghai, China
35 Electric Circuit Breakers Suppliers