Please click here to check who's online and chat with them.

Find Verified Electronic Semi Conductor Devices Other Components Suppliers, Manufacturers and Wholesalers

Top Supplier Cities : Shenzhen   Guangzhou   -  
Apr-18-11

Mitsubishi Q00Cpu

$241
MOQ: Not Specified
 
Mitsubishi PLC Q00CPU
MITSUBISHI PLC FX1S series, FX1N series, FX2N series, FX3U series, FX3UC series, A series, Q series.

Original Mitsubishi package.
Apr-18-11

Mitsubishi Qx42

$188
MOQ: Not Specified
 
Mitsubishi Q-series PLC qx42
1.Program storage capacity:100k step, super-speed
2.New and original
3.Competitve price.


Original Mitsubishi package.
Apr-18-11

Mitsubishi A1S64Ad

$177
MOQ: Not Specified
 
Specifications
Mitsubishi A-series PLC A1S64AD
1.No copy,no fake, no renew/rebuild product.
2.New and original.
3.Competitve price.

Delivery Detail 3 days after payment.


Original Mitsubishi package.
Apr-18-11

Mitsubishi H5Cx-A-N

$83
MOQ: Not Specified
 
Specifications
Omron timer H5CX-A-N
1.Good and competitive prices.
2.New and original.
3. Fast delivery
4. Warranty.

Delivery detail depends on quantity.

Omron original package.
Nov-10-10
 
Specifications
Display: 4 digits LCD, backlit
Range: 0~1250 »m/0~50mil
(other ranges can be specified )
Min.radius workpiece: F: Convex 1.5mm/Concave 25mm
N: Convex 3mm/ Concave 50mm
Min. measuring area: 6mm
Min.Sample thickness : 0.3mm
Resolution: 0.1 »m (0~99.9»m);
1 »m (over 100»m)
Accuracy: f+1~3%n or 2.5 »m or 0.1mil
(Whichever is the greater)
Bttery Indicator: Low batter indicator.
PC interface: with RS-232C interface
Power supply: 2x1.5 AAA(UM-4) battery
Operating condition: Temp. 0~50f¦ .
Humidity <95% .

Standard accessories:
Carrying case ...................1 pc.
Operation manual ............ 1 pc.
F probe in built .................1 pc.
NF probe in built...............1 pc.
Calibration foils ..............1set.
Substrate (Iron) ................1 pc.
Substrate (Aluminium)......1 pc.
Optional accessories: RS-232C cable & software:
1.USB adaptor for RS-232C
2.Bluetooth interface




Size: 126x65x35 mm; 5.0x2.6x1.6 inch
Weight: about 81g(not including batteries)
1184 Electronic Semi Conductor Devices Other Components Suppliers
Short on time? Let Electronic Semi Conductor Devices Other Components sellers contact you.
Nov-09-10
 
Acceleration 10Hz-1KHz 0.1-400m/ms+  0.3-1312ft/ms+ 
10Hz-10KHz 0.1-400m/ms+  0.3-1312ft/ms+ 
Velocity 10Hz-1K 0.1-400mm/s 0.004-16.0inch
Displacement 10Hz-1KHz 0.001-4.0mm 0.04-160 mil
Accuracy:++5%
Auto power off
RPM(revolution):5-100000r/min
Frequency:0.1 to 10KHz
Metric/imperial conversion
With RS232C interface
Max hold
Operating conditions:0-+45f+(32=¬-104=¬),f-90%RH
Power supply:4x1.5V AAA(UM-4)battery
Battery indicator: low battery indicator
Optional accessories: RS-232C cable & software:
1.USB adaptor for RS-232C
2.Bluetooth interface




Dimensions : 124x62x30mm
Weight: 120g(not including battery)
Nov-10-10
 
Application:
Used for measuring periodic motion, to check the imbalance and deflecting of moving machinery.Is pecifically designed for present measuring various mechanical vibration. So as to prove the data for the quality control, run time and equipment upkeep.
Iuse the high-performance acceleration meter, realize the repetitiveness and accurate measurement.It has the function of testing axle bearing situation.
Specifications:
Acceleration 0.1-200m2/s (10Hz to 1KHz 10Hz to 10KHz )
Velocity : 0.1-200mm/s0. (10Hz to 1KHz)
Displacement: 0.001-2.0mm(10Hz to 1KHz)
Accuracy:·+5¼t
Auto power off
Max hold
Operating conditions:0-+40f¦(32+H-104+H),f_90%RH
Power supply: 4x1.5V AA(UM-3)battery
Battery indicator: low battery indicator



Dimensions : 160x68x32mm
Weight: 181g(not including battery)
Nov-10-10
 
Features
Used in production site to measure surface roughness of various machinery-processed parts, calculate corresponding parameters according to selected measuring conditions and clearly display all measurement parameters.
Specifications
Displayª 4 digits, 10 mm LCD, with blue backlight
Parameters: Ra, Rz
Display Range
Ra: 0.05-10.00um/1.000-400.0uinch
Rz: 0.020-100.0um/0.780-4000uinch
Accuracy: Not more than 10%
Fluctuation of display value: Not more than 6%
Sensor :
Test Principle: Inductance type
Radius of Probe Pin: 10um
Material of Probe Pin: Diamond
Measurement Force of Probe: 16mN(1.6gf)
Probe Angle: 90fp
Vertical Radius of Guiding Head: 48mm
Maximum driving stroke: 17.5mm/0.7inch
Cutoff length (l): 0.25mm / 0.8mm / 2.5mm optional
Evaluation length: 1~5 cut off optional
Driving speed:
sampling length = 0.25mm Vt=0.135mm/s
sampling length = 0.8mm Vt=0.5mm/s
sampling length = 2.5mm Vt=1mm/s
returning Vt=1mm/s
Resolution : 0.001¬ªm if reading ·+10¬ªm
0.01¬ªm if 10¬ªmf_reading·+100¬ªm
0.1¬ªm if reading fª100¬ªm
Power Li-ion battery: rechargeable
Operating conditions: Temp. 0-50f¦
Humidity <80%

Attachment:
Standard Sensor RP-100
Groove Stylus SRP-110
curvature Probe SRP-120
Extension Rod SER-150
Mesurement Stand SRS-1
Standard Sample Plate SSP-180
Cable and Software for RS-232/USB)
Bluetooth interface



Size·ª140x57x48 mm (5.5x2.2x1.9 inch)
Weight: about 420 g
Nov-10-10
 
Features
This instrument is compatible with four standards of site to measure surface roughness of various machinery-processed parts, calculate corresponding and clearly display all measurement parameters.
When measuring the roughness of a surface, the sensor is placed on the surface and then uniformly slides along the surface by driving the mechanism by the sharp built-in probe. This roughness causes displacement of the probe which results in change of inductive amount of induction coils so as to generate
Specifications
Display·ª 4 digits, 10 mm LCD, with blue backlight
Parameters: Ra, Rz, Rq, Rt
Measuring Range
Ra, Rq: 0.005-16.00um/0.020-629.9uinch
Rz,Rt: 0.020-160.0um/0.078-6299uinch
Accuracy: f_f+10%
Fluctuation of display value: Not more than 6%
Sensor :
Test Principle: Inductance type
Radius of Probe Pin: 5um
Material of Probe Pin: Diamond
Dynamo-measurement of Probe: 4mN(0.4gf)
Probe Angle: 90fp
Vertical Radius of Guiding Head: 48mm
Maximum driving stroke: 17.5mm/0.7inch
Cutoff length (l): 0.25mm / 0.8mm / 2.5mm optional
Evaluation length: 5l
Driving speed:
sampling length = 0.25mm Vt=0.135mm/s
sampling length = 0.8mm Vt=0.5mm/s
sampling length = 2.5mm Vt=1mm/s
returning Vt=1mm/s
Profile digital filter
Filtered Profile: RC
Filtered Profile: PC-RC
Filtered Profile: Gauss
Non-Filtered Profile: D-P
Resolution : .001¬ªm if reading ·+10¬ªm
0.01¬ªm if 10¬ªmf_reading·+100¬ªm
0.1¬ªm if reading fª100¬ªm
Evaluation length : 5 cut-off
Power Li-ion battery: rechargeable
Operating conditions: Temp. 0~50f¦
Humidity <80%
Attachment:
Standard Sensor RP-100
Groove Stylus SRP-110
curvature Probe SRP-120
Extension Rod SER-150
Mesurement Stand SRS-1
Standard Sample Plate SSP-180
Cable and Software for RS-232/USB)
Bluetooth interface




Size·ª140x57x48 mm (5.5x2.2x1.9 inch)
Weight: about 420 g
Nov-17-10
 
Wholesale PH Meter
Nov-17-10
 
Measurement Range
Aú¦50~12000FPM
Bú¦50~40000 FPM
Cú¦50~20000 FPM
Dú¦50~30000 FPM
Eú¦50~2000 FPMú¿fit for print and textileú¬
Displayú¦5 10mmLCD
Accuracyú¦í+ú¿0.05%n+1dú¬
Resolutionú¦0.1 FPMú¿ Less 1000 FPMú¬
1 FPMú¿Over 1000 FPMú¬
Sampling timeú¦0.3second
2 rangesú¦HíóL ú¿High, Low ú¬
Flash adjustú¦Coarse adjustmentíófine adjustment , í-2 and í-2 for fast check
Triggering Modeú¦Interior/Exterior
Temperatureú¦0~40íµ
Humidityú¦Less than 85%RH
Nov-16-10
 
Product synopsis
Model: HM-6561
Typical Applications
Die cavity of molds
Inspection of bearing and other mass produced parts on a production line
Failure analysis of pressure vessel, steam generator and other equipment
Inspection of installed machinery, permanent parts of assembled systems and heavy work pieces.
Testing surface of a small hollow space
Material identification in the warehouse of metallic materials
Rapid testing in large range and multi-measuring areas for large-scale work piece
Testing Features
Palm size for narrow space.
Test at any angle, even upside down.
Direct display of hardness scales HRB, HRC, HV, HB, HS, HL.
Large memory could store 250 groups including single measured value, impact direction, material and hardness
scale etc.
User recalibration function allowed.
Can communicate with PC computer for statistics and printing by the optional cable.
Manual or automatic shut down.
Low battery indication.
Technical Specifications
Display: 12.5mm LCD with back light
Accuracy: Display error í+0.8% at LD=900
Measuring range: 200-900L
Conversion: HL-HRC-HRB-HB-HV-HSD
Materials: 9 different common materials
With RS232C interface
Memory: 250 data can be stored and re-readable
Impact device: D Will handle the majority of hardness testing applications. Weight: 75g
Power supply: 2x1.5V AAA size battery
Working temperatureú¦ - 10íµí½ú½50íµ
Storage temperatureú¦- 30íµí½ú½60íµ;
Relative humidity: í_90úÑ


Dimension: 146í-65í-36mm
Weight: 130g (not including batteries)
Oct-05-09

Grid Paraboloid Antenna

$100
MOQ: Not Specified
 
Electrical Specifications
Frequency Range 2400-2485 MHz
Gain (co-polar ) 24dBi
H-Plane 3dB Beamwidth 8í+1 degree
E-Plane 3dB Beamwidth 10í+1 degree
Side Lobe Level ú+-15dB
Front-Back Ratio >25dB
Polarization Horizontal or Vertical
Cross-Polar Discrimination >18dB
Impedance 50ª+
VSWR < 1.5
Maximum Input Power 100W
Connector N Female
Lightning Protection Direct Ground.

Mechanical Specifications
Dimensions ú¿L í- Wú¬ 900mm í- 600mm
Weight of Antenna 3.5kg
Diameter of Installation Pole ª¦30~50mm
Angle of Pitch 0 ~ 40 degree
Rated Wind Speed 200km/h.
Oct-05-09

Ceiling Antenna

$100
MOQ: Not Specified
 
Product Numberú¬: GCI04029-3V/806~2500
Electrical Specifications
Frequency Range 806í½960 MHz &1700í½2500MHz
Gain 2dBi/5dBi
Horizontal 3dB Beamwidth 360íp
Polarization ¦¦+¦ Vertical
Impedance 50ª+
VSWR í_1.4
Maximum Input Power 50 W
Connector Nú¡F
Cable Length 290¬L
Lightning Protection +¦-˜++¦+ Direct Ground.

Mechanical Specifications
Dimensions ª¦170mmí-89mm
Weight of Antenna 500g
Radome Material ABS.
Dec-28-09

Arm Type

$20
MOQ: Not Specified
 
Specification
60 groups memory function.
Average function for last 3 times measurement value.
Fuzzy Logic technology.
Arrhythmia detection function (IHB).
Automatically inflate and deflate.
Automatic power-off function.
Power: 4 AA size alkaline batteries.
Measurement Range: Pressure: 0mmHg~299mmHg; Pulse: 40~200 times/min.
Measurement Accuracy: Pressure: +/- 3mmHg; Pulse: +/- 5% of reading.
Aug-22-08
 
Clamp on ground resistance tester

ETCR 2000C
*Accurate ground resistance measurement from 0.01to 1000Ohms
*current measurement including leakage current
*Accurate readings regardless of power quality in 1 seconds
*Simple and easy to use, no test leads or auxiliary electrodes necessary
*Data logging capability - 50 records
*Individual data point recording
*User selectable audible alarms
*Auto power off
*Low battery indicator
*Large LCD display

Ground Resistance: 0.010 - 0.099 Ohms (¿¬+ 1% ¿¬+ 0.01 Ohms, resolution 0.001 Ohms)
Ground Resistance: 0.10 - 0.99 Ohms (¿¬+ 1% ¿¬+ 0.01 Ohms, resolution 0.01 Ohms)
Ground Resistance: 1.0~49.9 Ohms (¿¬+ 1.5% ¿¬+ 0.1 Ohms, resolution 0.1 Ohms)
Ground Resistance: 50.0~99.5 Ohms (¿¬+ 2% ¿¬+ 0.5 Ohms, resolution 0.5 Ohms)
Ground Resistance: 100~199 Ohms (¿¬+ 3% ¿¬+ 1 Ohms, resolution 1 Ohms)
Ground Resistance: 200~395 Ohms (¿¬+ 6% ¿¬+ 5 Ohms, resolution 5 Ohms)
Ground Resistance: 400~590 Ohms (¿¬+ 10% ¿¬+ 10 Ohms, resolution 10 Ohms)
Ground Resistance: 600~1000 Ohms (¿¬+ 20% ¿¬+ 20 Ohms, resolution 20 Ohms)
Ground Leakage Current: 0.00~299 mA (¿¬+ 5% ¿¬+2 mA) resolution 1 MA
Ground Leakage Current: 100~299 mA (¿¬+ 5% ¿¬+5 mA) resolution 1 mA
Ground Leakage Current: 0.30~2.99 A (¿¬+ 5% ¿¬+0.03 mA) resolution 10 mA
Ground Leakage Current: 0.30~2.99 A (¿¬+ 5% ¿¬+0.03 mA) resolution 10 mA
Ground Leakage Current: 10.00~20.00 A (¿¬+ 5% ¿¬+0.5 mA) resolution 10 mA.
May-26-09
 
Earth Resistance Tester:
Model: ETCR2100+(basal)
Category: Ground Resistance tester
Earth Resistance Tester (ETCR2100+)-Illustration:
ETCR 2100+ of Pincers Earth Tester, in the measurement of a grounding system with loop current, does not require breaking down the grounding wire, and need no auxiliary electrode. It is safe, fast and simple in use.
1.Wider range: 0.01Ñ+-1200Ñ+
2.Stored data: 99 groups.
3.Resistance Resolution: 0.01Ñ+
4.Size of Jaw: ¬¬32ú¿mmú¬
5. Sound and light alarm, "beep - beep - beep -" alarm sound.
6. Breakthrough in self-test the boot a long time to wait, start immediately into the test.
7. Breakthrough relay self-test mode, using the most advanced processing algorithms and digital integration technology, a fully intelligent.
8. Break the old product to heavy issues, more in line with characteristics of handheld devices.
9. The new design, panel 6 button operation, the performance through.
10. Lower power consumption: Maximum operating current not exceeding 50mA.




260*90*66(MM)
May-26-09
 
Function random phase measurement, AC current and leak current measurement, AC Voltage detection, distinguish the inductive circuit and capacitive circuit, sequence of three-phase voltage detection and connection group of transformer detection, etc.
Power supply DC9V alkaline dry battery LR6f-6 continuous duty :300h
LCD 3-1/2 LCD display
Dimension Width *length* thick·ª92mmf-192mmf-50mm
LCD dimension Display domain·ª64mmf-54mm ·+font high·ª40mm
Clamp mouth ¬+7.5mm ·+¬+40mm lectotype·¼
Measuring range phase·ª0~360fp·+current·ª0~200mA/2A/10A·+voltage·ª0~20V/200V/500V
resolution phase·ª1fp·+current·ª0.1mA·+voltage·ª0.01V
Measurement accuracy
·+50Hz,23f¦f+1f¦·+40-60%RH·¼ phase·ªf+3fp
current·ªf+1%f+2dgt
Voltage·ªf+1.2%f+2dgt
line voltage Line test under AC500V
Sampling speed About 3 times /s
Signal frequency sine wave 45Hz~55Hz ¬-=0.05
Data hold Data holding function·ªdisplayed by fªDHfª symbol
Back light function Blue back light ,suit for dark occasion
Automatic shutdown After starting up 15min·+it shutdown automatically to reduce battery consumption
Battery voltage When battery voltage is low ,battery low voltage symbol will filker to remind replacing battery;
Quality Core about590g·+with battery·¼·+long flat nose current pliers about ·ª175gf-2·+big round tongs clamp·ª120g
Work temperature and moisture -10f¦~40f¦·+85%rh below
Storage temperature and moisture -20f¦~60f¦·+70%rh below
Driving point impedance AC voltage driving point impedance·ª2M¬+·+when test phase U1-U2·ª40K¬+
Insulation intension fª10M¬+9·+Between wire of meter and crust·+two voltage input port·¼
Voltage bear Between port of voltage input and box, split core type currenttransformator and clamp handle& winding coil: 1000V/50Hz, 1min experiment can be reach when sine wave AC voltage 500V/50Hz between port of voltage input.




92*192*50(mm)
May-26-09
 
Specifications

Function AC leak currentú¼high-harmonic currentú¼0n line current testú¼phaseíóelectrical energyú¼power factor revise
Test mode Clip-onCT
Output mode Current mutual inductance output uA/mAú+mA/A or voltage output mV/mAú+mV/Aú¿lectotypeú¬
Dimensions Widthí-heightí-thicknessú¦64mmí-160mmí-23mm
Clamp mouth ª+40mm
Wire length 2.0mú¿by orderú¬
Measure range AC 1uAí½80Aú+10uAí½300Aú+10mAí½600Aú¿lectotypeú¬
Resolution 1uAú+10uAú+5mAú¿lectotypeú¬
Accuracy 1% ú+2%ú¿50Hzú+25íµí+3íµú¬ú¿lectotypeú¬
Linearity degree 1% ú+2%ú¿50Hzú+25íµú¬ú¿lectotypeú¬
Work frequency 10í½100KHz
Wire voltage Line test under AC600V
Quality About120g
Working temperature and humidity -25íµí½70íµú+below 80%rh
Storage temperature and humidity -10íµí½60íµú+below 70%rh
Insulation AC2kV/rms (between core and box)
Applicable safety rules IEC1010-1íóIEC1010-2-032íópollution, etc 2íóCAT ó=(600V).
May-26-09
 
Specifications
Function AC leak currentú¼high-harmonic currentú¼0n line current testú¼phaseíóelectrical energyú¼power factor revise
Test mode Clip-onCT
Output mode Current mutual inductance output uA/mAú+mA/A or voltage output mV/mAú+mV/Aú¿lectotypeú¬
Dimensions Widthí-heightí-thicknessú¦138mmí-42mmí-20mm
Clamp mouth ª+7.5mm
Wire length 2.0mú¿by orderú¬
Measure range AC 1uAí½10Aú+ 5uAí½20Aú+10uAí½50A
Resolution 1uAú+5uA ú¦10uAú+ú¿lectotypeú¬
Accuracy 0.1-0.2ú¿50Hzú+25íµú¬
Ungraded load í_50ª+
Work frequency 10í½100KHz
Wire voltage Line test under AC600V
Quality About175g
Working temperature and humidity -25íµí½70íµú+below 80%rh
Storage temperature and humidity -10íµí½60íµú+below 70%rh
Insulation AC2kV/rms (between core and box)
Applicable safety rules IEC1010-1íóIEC1010-2-032íópollution, etc 2íóCAT ó=(600V).
1184 Electronic Semi Conductor Devices Other Components Suppliers
Short on time? Let Electronic Semi Conductor Devices Other Components sellers contact you.