Please click here to check who's online and chat with them.

Find Verified Transformer Oil Suppliers, Manufacturers and Wholesalers

Jan-12-19

Glass Fiber Insulation Tubes

$1 - $10
MOQ: Not Specified
Supplier From Zhengzhou, Henan, China
 Inquire Now  
Phenolic Paper-base Laminated Tube PFCP22A(IEC) Class E
Phenolic Cloth-base Laminated Tube PFCC21A/24A Class E
Epoxy Laminated Glass Cloth Tube EPGC21/22 Class B/F
Silicone Laminated Glass Tube SIGC21 Class H
Bismaleimide Laminated Glass Cloth Tube BMIGC21 Class H
Epoxy Glass Fiber Winding Tube EPCF52 Class H
Modified Diphenyl Ether Laminated Glass Cloth Tube Class H
Polyester Imide Laminated Glass Cloth Tube Class H
Non-circular Tube (square tube, oval tube)
Description:
3520(é??é??å±?å??纸管)
This product has good mechanical and electrical properties. It can be used for motor and electrical equipment and also can be used in transformer oil.
380/380A (é??é??æ£?å¸?å±?å??管)
The product has higher radial tensile strength. It can be used as support structure and wear-resistance parts of seals or bears.
EPGC21/22ã??355ã??356ã??SIGC21ã??BMIGC21
With good dielectric property and machinability, the product can be used as components of insulation structural of electrical equipment, and can also be made into coil insulation tube and insulation end coil of dry-type transformer.
Epoxy Glass Fiber Winding Tube 360 EPCF52
Description:
This product adopts fiber glass yarn that is impregnated with insulation jelly made of epoxy resin and other resins by certain proportion, and then it is rolled in wet method, and dried and finally consolidated by baking. Its heat resistance level is up to Class H, and it also has excellent electrical and mechanical properties, chemical resistance (SF6), low dielectrical loss, no deformation or delamination. It can be used as main insulator on H grade dry-type transformer, load tap changer, electricâ??reactor, lightning arrestor, SF6 inductor, etc.
5. Non-circular Tube (square tube, oval tube) Class F/H
Description:
Non-circular tube is made of high temperature resistant resin and fiber glass cloth or yarn that are rolled in the wet method, and then dried and finally consolidated by baking. It has excellent mechanical, dielectric and mechanical properties. It can be used as components of insulating structure of electrical equipment, and can be also used in transformer oil and in wet environment. It is suitable for transformer, reactor, etc.
Mar-24-17

3240 Epoxy Resin Insulation Laminate Sheet

$1.50 - $1.00K
MOQ: Not Specified
Supplier From Shenzhen, Guangzhou Proince, China
 Inquire Now  
Introduction: Epoxy phenolic glass cloth laminated sheets(insulation sheet,industry laminate sheet,Epoxy sheet) are made of alkali-free E-glass cloth impregnated with epoxy resins and phenolic resins by processing under heat and pressure. Epoxy glass cloth sheet can be processed into all kinds of insulation parts, The products are widely used transformers, electric motors, cabinets, control boxes, electric switches, household appliances, railway, automobile, computer and medical appliance,etc.
Models: 3240A sheet: High mechanical and electrical applications, suitable for insulation structural parts of machinery and electric equipments under wet condition, available in transformer oil and humidity.
3240B sheet is similar to 3240A, but with lower properties.
Dimension: Nominal dimension : 1020Ã?2040mm; Thickness: 0.5 ~ 100mm
Jan-11-17
Supplier From Shenzhen, Gungdong, China
 Inquire Now  
Keyword:
GSM 3G Power Distribution Monitoring Systems, GSM power quality monitoring, GSM 3G Power transmission line monitoring system , GSM 3G Transmission Line Security Monitor, GSM 3G energy monitoring system, GSM 3G Transformer Monitoring, GSM 3G Transformer Oil Monitoringâ??, GSM 3G Transformer Oil Health Monitoring, GSM 3G Transformer oil moisture monitoring, GSM 3G transformer oil level monitoring, gsm 3g Transformer Fire alarm, gsm 3g Remote online transformer monitoring. GSM 3G Power distribution safety monitoring system.

The GSM 3G Power Distribution Monitoring System is not only a smart power meter for measuring the power distributor voltage, current, factor, watts, frequency, active power, reactive power, when over current or exceed the pre-set value, will alarm immediately.
The GSM 3G Power Distribution Monitoring System can be used for monitoring the oil temperature, oil level of the transformers. GSM 3G Wireless Power Line monitoring.

The GSM 3G Power Distribution Monitoring System also can be used as a wireless security alarm system for the transformers, e.g.: theft-proof, fall down, and so on.
Model Description
S250 GSM GPRS Power Cable Anti-Theft Alarm System
S251 GSM 3G Power Distribution Monitoring System

1. ARM® Cortex�-M4 32 Bit RISC Core, 72MHz inside, RTOS system;
2. Quad-Band GSM Frequency,3G, supports SMS and Voice and GPRS/3G communication;
3. Programmable by SMS Commands or PC Configurator via USB;
4. A/B/C phase power up it directly, Inbuilt large capacity rechargeable backup battery;
5. Suitable for three-phase four-wire system, input voltage: 100~400V, input current:0~5A;
6. Monitoring A/B/C 3 Phase input over current, over voltage , factor, watts, active power, reactive power exceeds alarm;
7. Power input PT,CT rate are programmable;
8. Accuracy of current, voltage is 0.2 class, power and watts is 0.5 class, sampling is 0.1seond.
9. Large internal memory can save 1000 event historical data;
10. 6 analog inputs, 16bits, supports 0-5V, 0-20mA, 4-20mA;
11. 2 digital outputs, 5A/30VDC,5A/250VAC, can be program to events or turn on/off by SMS;
12. 8 digital inputs, NC/NO/EOL type, when digital input recover can alert by SMS;
13. I/O ports with opto-isolated and lightning protection;
14. Provide one 5VDC@1A power for additional device;
15. Equips LCD to display the real time data and for programming;
16. 2 IP data centers, supports GDW 376.1â??2009 protocol over GPRS/3G network;
17. 1 RS485 can be used as data transparent transmission for additional intelligent meters or PLC, with 15KV ESD protection;
18. Automatically resend the data while communication failure, GPRS failure will alert by SMS text;
19. 8 SMS Alert and auto dial numbers, can program to receive specified alarm message.
20. Automatically report its status to users by the specified time.
GOLD Member
Mar-02-26
Supplier From Nellore, Andhra Pradesh, India
 Inquire Now
Service Provider Of Manufacturer & Exporter

Supplier Of Plumbing - Pipes, Fittings, Flanges, Elbows & Hoses   |   Construction Materials   |   Computer Cables   |   Converters & Switches   |   Electric Transformers   |   Wires & Cables   |   Cable Assemblies   |   Optical Fiber Cables   |   Coaxial Cables   |   Electric Connectors   |   Electric Switches & Isolators   |   Electric Switch Gears   |   Electric Fuses   |   Electric Circuit Breakers   |   Temperature Controllers & Indicators   |   Electric Sockets & Plugs   |   Electric Relays   |   Earthing Equipments   |   Mobile Phone Accessories   |   Electronic Relays   |   Electronic Connectors   |   Electronic Transformers   |   Automobile Plugs   |   Flanges   |   Stainless Steel Pipes & Pipe Fittings   |   Stainless Steel Flange   |   Steel Pipes   |   Mustard Seeds   |   Groundnut Kernel   |   Soybean   |   Spices   |   Cumin Seeds   |   Tamarind Seed   |   Pepper   |   Coriander Seeds   |   Red Chilli   |   Turmeric   |   Chilli Powder   |   Cumin Powder   |   Turmeric Powder   |   Basmati Rice   |   Non Basmati Rice   |   Pulses   |   Fresh Onion   |   Groundnuts   |   Soya Oil   |   Groundnut Oil   |   Sunflower Oil   |   Mustard Oil   |   Solar Power Equipments   |   Solar Batteries   |   Solar Controllers   |   Solar Panels   |   Solar Inverters   |   Black Pepper   |   Seeds   |   Onion   |   Red Onion   |   Fresh Red Onion   |   Whole Turmeric Fingers
Mar-25-19
 Inquire Now  
S11 Series 6kV-35kV power Transformer With Off Circuit Tap Changer,power oill transformer,high voltage step up transformer,distribution transformer
The products implement the National Standard GB1094-2013 Power Transformer and GB / T6451-2015 Three-phase Oil-immersed Power Transformer Technical Parameters and Requirements, and are recommended as the major equipment products for the national urban and rural power grid construction and retrofit by the State Economic and Trade Commission.
Product Description
The products implement the National Standard GB1094-2013 Power Transformer and GB / T6451-2015 Three-phase Oil-immersed Power Transformer Technical Parameters and Requirements, and are recommended as the major equipment products for the national urban and rural power grid construction and retrofit by the State Economic and Trade Commission.
S11 series transformer adopts high quality material for copper winding, especially applying the new technology and new material for the coil insulation and active parts, thus the no-load and the load loss are obviously reduced, the performance and structure are more reliable and superior.

Product Features
 Good Economic Performance
The no-load loss for S11 series products decreased 10.3% averagely, no-load current decreased 22.4% based on S9 series.
Long Service Life
Transformer tank adopts hermetical structure, tank and tank cover can be connected by bolts or welded firmly, the transformer oil wont contact with air, so that extend the service life effectively.
High Operation Reliability
Improve the relevant sealing parts for the tank, increase the reliability and advance the technical level to ensure the reliability of the seal.
Small Installation Area
S11-M series transformer tank uses the corrugated plate radiator. When the oil temperature changes, the corrugated plate will proceed thermal expansion, which can replace the role of the oil conservator. the corrugated plate tank has beautiful appearance, less occupied area.
484 Transformer Oil Suppliers
Short on time? Let Transformer Oil sellers contact you.
May-17-22

250 Kva Distribution Transformer Oil Type

$3.89K
MOQ: Not Specified
Supplier From Sanliurfa, Turkey
 Inquire Now  
250 kVA OIL TYPE DISTRIBUTION TRANSFORMER
Measuring winding resistances

Measurinq rotation ratios

Inspecting polarity or connection group

Measuring short circuit and load losses

Measuring idle losses and current

Induced voltage test

Applied voltage test

Measuring insulation resistances

Transformers, for which mounting, drying

and oil filling works are completed, are

subjected to below mentioned routine and

typical tests as specified by TS 267 standard.

Oil breakdown stress control

Loss gap (tq) measurement (DOUBLE test)

Measuring painting thickness

Temperature increase (heating test)

Measuring of audible noise level

Boiler lifetime test (For Hermetic Transformers)

Mechanical strength test against short circuits

This test is conducted in CESI/ITALIA,

IPH/GERMANY test laboratories.)

Except for the mechanical strength test against

short circuits, all typical tests are conducted

in the laboratories of our company,
Jan-29-21
 Inquire Now  
1. The low-voltage winding is of cylindrical or spiral structure, with high mechanical strength and good short-circuit resistance.
2. The corrugated oil tank is adopted to replace� the oil conservator. The oil tank cover and the oil tank are all-welded along the edge or fastened with bolts, thus prolonging the service life of the transformer oil.
3. After oil removal, embroidery removal, and phosphating treatment, the product is sprayed with three times of primer and one time of finish paint inside and outside. The product is salt fog proof, damp heatproof, and fungus� proof, which can meet the special requirements of metallurgy, petrochemical system, and wet and polluted areas. It is beautiful� and reliable.
4. The transformer oil tank is� fully sealed, and� equipped with� pressure reducing valve, signal thermometer, gas relay, etc according to the standard requirements to ensure the safe operation of the transformer.
5. This series of products are beautiful in appearance, small in size, and can reduce the installation area. It is an ideal maintenance-free distribution product.
Oct-17-08
Supplier From Hosur, Tamul Nadu, India
 Inquire Now  
Transformer spares & accessories - like metal parts, cu / alu wires and strips press boards, insulating material m12 / m 20 bolt/ nut, brazing rod, transformer oiland others

Wieght
Mar-11-19
 Inquire Now  
Transformer Capacity and Loss Tester
Transformer Oil Tester

I  Introduction
Transformer Capacity Testing Instrument is specialized in bad power users evading basic electricity secretly adds capacity problems and is a high precision instrument specially used for the measurement of the transformer capacity and parameters. This product uses color LCD monitor, English display, simple and quick menu operation, man-machine interface is friendly. The internal of the instrument has a rechargeable battery and it can work without external power source. A fully charged battery can be continuously measured more than 100 sets. In addition, the instrument can provide three-phase precise 50Hz sine wave AC test power without the external three-phase test power, the pressure regulator, up flow reactor and other auxiliary equipment in measuring the capacity and transformer load loss, thus greatly improving the efficiency of the work.

This is a multi-functional measuring instrument, which is equivalent to two common devices: activity transformer capacity tester and transformer parameter tester. It can be used for test transformer capacity, model, no-load current, no-load loss, load loss, impendence voltage and so on.

This product has many advantages such as small, light , high accuracy, stability, simple operation and so on. It can replace the multi-meter method to measure the transformer loss and capacity with simple wiring and convenient testing so that the work efficiency can be greatly improved.

Function

1. We can measure a variety of distribution transformer, power transformer capacity instead of the additional power. It is more convenient and efficient.

2.Combined with the power, voltage, boost up flow and other equipment, it measures various transformer no-load current, no-load loss, impedance voltage, load loss and so on.

3.All results are automatically carried out relevant correction. You only need to input the related parameters (such as temperature, load adjustment coefficients), then the instrument can automatically correct such as waveform deformity correction, temperature correction, correction of non rated voltage, rated current correction.

4.The maximum voltage is up to 750V and the maximum current is up to 100A. It is equipped with protection circuit.

5.The voltage and current range can be very flexible and easy to expand.

6.It has large screen, high brightness LCD display, English menu and operation tips, friendly man-machine interface and wide temperature, brightness adjustable type LCD screen, which can adapt to the different temperature.
Oct-21-21

Transformer Oil Chromatography

$770 - $15.40K
MOQ: Not Specified
 Inquire Now  
Product description

This instrument absorbs the advanced technology of similar products at home and abroad, and can set up various parameters through the keyboard. This machine has a power down protection, over temperature protection, "0" C protection and gas protection, automatic electronic ignition, etc. it has the characteristics of stable and reliable performance, simple and reasonable structure, simple operation, high expansibility, etc.

Technical index

Temperature control:

a. Chromatographic column chamber temperature

a.1 Temperature control range: room temperature +8 400(Set the temperature increment 1)

a.2 The precision of temperature control: It is±0.1, which is below 200;
Jun-18-18
 Inquire Now  
Dry type transformers shall be installed in accordance with the manufacturer's requirements, and shall be equipped with temperature measuring devices, generally 630kVA and above transformers.
A,1000kVA and above oil-immersed transformer shall be equipped with an outdoor signal thermometer and can take distant signals.
Product features:
A, tank using corrugated sheet, it has the respiratory function to compensate for temperature change caused by the oil volume change, so the product without oil storage tank, obviously reduce the height of the transformer.

B, because the corrugated film replaces the storage tank, the transformer oil is isolated from the outside, thus effectively preventing the entry of oxygen and water and the decrease of insulation performance.

C, according to the above five performance, to ensure the oil-immersed transformer within the normal operation of the don't need an oil change, greatly reduces the maintenance cost of transformer, and prolong the service life of the transformer.
D. In addition to the small capacity of copper wire, copper foil is usually used in the cylinder structure.
The high voltage winding adopts multi-layer cylindrical structure to balance the ampere-turns distribution of the winding, the leakage is small, the mechanical strength is high, and the anti-short circuit capability is strong.

E, iron core and winding each adopt the fastening measure, the height of the device, the low voltage lead wire and other fastening parts are equipped with self-locking anti-loose nuts, adopt the non-lifting structure, can withstand the shock of transportation.

F, coil and iron core adopt vacuum drying, the transformer oil adopts vacuum filter oil and oil filling process, which minimizes the moisture in the transformer.
Jun-18-18
 Inquire Now  
Dry type transformers shall be installed in accordance with the manufacturer's requirements, and shall be equipped with temperature measuring devices, generally 630kVA and above transformers.
A,1000kVA and above oil-immersed transformer shall be equipped with an outdoor signal thermometer and can take distant signals.
Product features:
A, tank using corrugated sheet, it has the respiratory function to compensate for temperature change caused by the oil volume change, so the product without oil storage tank, obviously reduce the height of the transformer.

B, because the corrugated film replaces the storage tank, the transformer oil is isolated from the outside, thus effectively preventing the entry of oxygen and water and the decrease of insulation performance.

C, according to the above five performance, to ensure the oil-immersed transformer within the normal operation of the don't need an oil change, greatly reduces the maintenance cost of transformer, and prolong the service life of the transformer.
D. In addition to the small capacity of copper wire, copper foil is usually used in the cylinder structure.
The high voltage winding adopts multi-layer cylindrical structure to balance the ampere-turns distribution of the winding, the leakage is small, the mechanical strength is high, and the anti-short circuit capability is strong.

E, iron core and winding each adopt the fastening measure, the height of the device, the low voltage lead wire and other fastening parts are equipped with self-locking anti-loose nuts, adopt the non-lifting structure, can withstand the shock of transportation.

F, coil and iron core adopt vacuum drying, the transformer oil adopts vacuum filter oil and oil filling process, which minimizes the moisture in the transformer.
Jun-18-18
 Inquire Now  
Execution standard
GB 1094.1-2 power transformer general rules, power transformer temperature rise
GB 1094.3 power transformer insulation level and insulation test
GB 1094.5 "power transformer capacity to withstand short circuit"
GB/T 6451 technical parameters and requirements of three-phase oil-immersed power transformer
GB/T 15164 load guide for oil-immersed power transformer
IEC76 power transformer
GB 2536 "transformer oil"
800KVA~31500KVA three-phase double-winding non-excitation voltage regulating power transformer:
Apr-01-17
 Inquire Now  
product description
S13-M oil-immersed distribution transformers for the distribution network and industrial and mining enterprises in the power supply and distribution system in the important equipment Transformer in the industrial and mining enterprises in various regions of the country, agriculture and civil construction can also be used in petroleum, chemical industry, Multi-chemical substances.
Capacity in the 630 ~ 2000kvA range of low-voltage windings with cylindrical or spiral structure, high mechanical strength, ampere-turn distribution balance, the product of good short-circuit resistance.
S13-M oil-immersed transformer body to add the positioning structure, so that in the transport process does not produce displacement, and all fasteners with fastening nuts to ensure that products in the long run is not loose during the fasteners to meet the Not hanging core requirements.
S13-M oil-immersed transformer uses a corrugated oil tank, cancel the oil conservator, cover and box along the complete death or bolt fastening, extending the service life of transformer oil.
S13-M oil-immersed transformer surface to the oil, to embroidery, phosphate coating after spraying primer, topcoat, to meet the metallurgical, petrochemical and wet pollution areas of special use requirements.
Selection of components, using a sealed transformer tank, according to standard requirements to install a pressure relief valve, signal thermometer, gas relays, etc., to ensure the safe operation of the transformer. The series of products beautiful shape, small size, can reduce the installation area, is the ideal maintenance-free high-quality products.
Jun-26-17

Wind Power Generation Transformer

$100.00K
MOQ: Not Specified
 Inquire Now  
Wind Power Generation Transformer
New Energy Dedicated Transformer
Product structure and features
General introduction
With the continuous growth of China's economy, the demand for electricity surged, energy has become the main contradiction. Because the traditional coal-fired and fuel power generation caused serious environmental pollution, so in order to be consistent with environmental protection requirements, wind power as a clean energy production that has been developed rapidly in our country , has become the main direction to solve the energy shortage. We company develop a series of wind power generation combination substation, which can change 690V voltage generated by wind power dynamotor to 35kVor 10kV voltage through rising and changing voltage, then send to gird system or users, finally finish the task of wind power generation. So, wind power generation combination substation is the best matching product of wind power generation system.
Structure and performance features
1, structure features
A, main body adopts the structure of common box transformer. Assemble high-voltage load switch, plug-in fuse, transformer body, off-circuit tap-switches and other H.V components in a sealed tank, transformer oil as insulating medium, its size is small and performance is excellent .

B, Overall combination type wind power substation is composed of H.V chamber, L.V. chamber, oil tank and radiator. Install chip radiator on the side of oil tank, the chip radiator is combined by guide pipe and cooling fin which can better adapt to high-power transformerâ??s cooling requirements. In order to prevent vandalism, to these cooling fins with weak mechanical, we will use steel shield that be punched cooling holes to enhance the protection. By substation, rise the voltage of power generated through wind dynamotor and merge into grids.
Jun-26-17

Usa-Type Transformer Substation

$100.00K
MOQ: Not Specified
 Inquire Now  
USA-type Transformer Substation
Box-Type Transformer Substation
ZG(F)S series prefabricated substation, also called USA-type transformer substation, is an new-mode complete set of power distribution equipments that absorbs foreign advanced technology and design concept. It is also can be used in our national power girds, including these distribution systems of industrial and mining enterprises, high-rise buildings, residential areas, stations, port terminals, especially suitable for alteration of urban and rural power grids, not only reduces engineering investment and occupying area, but also shortens the installation period.
Products features
Novel design, innovative structure, smaller volume
The high voltage overload switch, plug-in fuse and backup protection fuses are placed in transformer insulating oil tank, thus substations volume becomes smaller whose occupying area is only 1/3-1/5 of normal products.
Fully enclosed, fully insulating, safe and reliable
Transformer oil tank is fully enclosed structure without conservator. The high voltage inlet wire adopts connections of elbow-type cable plug and high voltage bushing, live parts sealed within the insulator, shape a fully insulating structure. Terminal surface is zero potential which can guarantee human safety.
Advanced protection principle, economic and reliable, easy to operate
Using full range protection mode of double fuse in high voltage side and supplemented by low voltage undervoltage protection to make operation reliable and easy. The body of transformer is used with S11,S13 series, its winding adopts Dyn11,with characteristics of neutral point not drifting, good lightning performance, low loss, low noise, etc.
Sep-25-18

Transformer

$1
MOQ: Not Specified
Supplier From Zhengzhou, Henan, China
 Inquire Now  
Electrical laminated wood is mainly used for transformers; it is also the insulation material and support material of mutual inductor. Besides, it can be used to make winding clamping plate, iron core plate, trapezoidal plate and clamping device. And it has many advantages, such as proper specific weight, high mechanical strength, good compatibility with transformer oil and easy machining. In addition, its dielectric constant is close to that of transformer oil and the insulation coordination between them is proper. It can be used in transformer oil under 105â?? for a long time.

Electrical laminated wood sheet is widely used in manufacturing some devices for oil-filled transformer, such as upper and lower pressure plate, lead bracket and iron yoke cushion block. And it is used to make clamping device in mutual inductor. It can replace steel plate, insulation paper board, epoxy paper board and epoxy fiberglass board, which can lower the weight of the transformer and the cost of materials.

It has been recognized to GB/T20634 or IEC61061.
Jun-03-17
 Inquire Now  
Introduction to Products
Its core is made of quality cold-rolled silicon sheet and is of a full-miter non-puncture structure and its coil is made of quality oxygen-free copper. It is artistic in appearance and safe in running and is widely used in transmission and distribution of industrial and agriculturalist.
Main Function And Features
It adopts radiator oil tank of corrugated sheet type or expansion type. As it doesnâ??t need oil conservator, the height of transformer is reduced , and as the transformer oil doesnâ??t contact with air , the oil ageing is retarded, thus prolonging the service life of transformer. The no-load loss of Model S10-M is 20% lower than that of Model S9-M , and S11-M is 30% lower than S9-M. the transformers are high in reliability , advanced in performance and rational in economical indexes . The oil tank is diversified in types and looks artistic and elegant.
May-17-12
 Inquire Now  
KLD-Z is an on-line oil particle counter of high precision. It adopts the principle of laser blockage method (laser shading method) to detect the size and number of solid particles in the oil. Based on the measurement, it does the analysis and then displays the oil contamination level in various standards (e.g NAS1638, ISO4406, GJB) so as to help the operator be aware of the potential risks and therefore avoid the evitable wear of parts.

KLD-Z is able to give out the result within 45 sec. An optical fiber cable goes along with the counter to connect the device to a PC or display screen to transfer data. KLD-Z can be widely applied to various kinds of oil, such hydraulic oil, lubricant oil, gearbox oil, insulating oil (transformer oil), etc. Due to its small size and light weight, it can be easily installed on equipments which consist of hydraulic system or lubricant circuit, etc. Therefore, the real time monitoring of the oil quality will be available!

Technical specification:
Weight 2.5Kg
Dimension: 94mm * 87mm * 46mm
Operating Ambient Temperature -20-60 Centigrade
Number of Channels 4
Flow Rate for online 50-500ml/min
Max Operating Pressure 500pa
Power Supply 9-36VDC
Viscosity 10-100 cSt(46-2000SUS)plus-minus 20%
Measurement Standard NAS 1638 00-21;ISO4406 01-29;GJB 420A 000-12.


Wrapped in see-through plastic bags and packed in standard export cardboard cartons.
Nov-24-25
 Inquire Now  
The load switch and fuse are immersed in transformer oil,
with good insulation and safe operation; The transformer
is placed outside in the air, which has better heat
dissipation; The structure is compact, small in size, easy
and flexible to install; Equipped with measurement and
control devices, with a high degree of automation, it can
remotely control and protect the low-voltage circuit
breaker, and monitor the status of various switches in the
compact substation, which is safe to operate and
convenient for control center
Jan-29-21
 Inquire Now  
As the most widely used power facility, power transformers have a wide variety of types and are of great significance to energy conservation and emission reduction. The S13 fully-sealed oil-immersed power transformer is currently the main selection product for power distribution equipment, with significant energy-saving effects. At present, mainstream distribution transformers generally use S13 laminated core power transformers. It adopts a fully oil-filled sealed type, no oil conservator, and a corrugated sheet box structure. The volume of the transformer changes due to changes in temperature and load, which is completely adjusted by the corrugated oil tank. Its no-load loss is much lower than that of S9, and it is resistant to lightning impact It has strong short-circuit resistance, obvious energy-saving effect, and reduces the overall size of the transformer.

The S13 transformer is made of high-permeability oriented silicon steel sheet with a thickness of 0.27-0.30mm and a unit iron loss of 1w/kg, while the new S9 type is an ordinary silicon steel sheet with a thickness of 0.30-0.35mm and a unit iron loss of 1.20 -1.55w/kg. The S13 distribution transformers produced by our company all use 30P series high-permeability oriented silicon steel, using foil-wound coils and new insulating materials and processes. The product is resistant to high temperature, impact, and fully sealed structure design to ensure the stability of transformer oil quality It prolongs the maintenance cycle. At the same time, the integral fuel tank composed of corrugated fin radiator is produced by phosphating and multi-layer anti-rust spraying process, which has good weather resistance.
May-28-19

Transformer Oil

$85
MOQ: Not Specified
Supplier From Jaipur, Rajasthan, India
 Inquire Now  
Transformer Oils in India that were more environment friendly and of high performance with higher oxidation stability, lower gassing tendency and non corrosive with ultra low levels of sulphur.

We produces a comprehensive range of high quality Transformer oils from selected severely hydro treated Naphthenic and Isodewaxed / hydrocracked Isoparaffinic Oils free from polar compounds and have very high oxidation stability and ageing properties guaranteeing long service life. The low sulphur wax free naphthenic oils with low Viscosity Index ensure excellent cooling characteristics, high solvency and low corrosivity and the highly refined ultra low sulphur paraffinic oils ensure excellent non corrosive properties. These optimum refined Transformer Oils also possess very good electrical and insulating properties, oxidation stability and controlled low or negative gassing tendency. Extensive efforts are taken to up grade our oils to meet the latest more severe and stringent control requirements of non corrosive oils.
Nov-04-25

Transformer Oil Filter Machine, New Manufacturered

$800 - $2.00K / Liter (CFR)
MOQ: Not Specified
 Inquire Now  
Sumesh Petroleum Pvt. Ltd. offers a complete range of high-performance oil filtration, purification, and transformer maintenance equipment. Our products are designed for efficiency, durability, and reliability in power and industrial applications. From Transformer Oil Filter Machines and Reclamation Plants to Air Dryer Systems, Hydraulic Oil Filters, and Ester Oil Filtration Plants, each unit ensures optimal oil quality and extended equipment life. Built with advanced technology and precision engineering, Sumesh systems help buyers maintain clean oil, reduce downtime, and improve transformer performance.
Feb-06-25
 Inquire Now  
Air Pressure Regulator 67CFR-600B
Is a spare part for power plants. Deyang YOYIK specializes in producing all kinds of generating units supporting the processing of power plants, power plants, metallurgical systems, chemical systems, color systems, steel mills, chemical fertilizer plants, colored copper and aluminum processing plants, coking plants, oxygen plants and other industrial and mining enterprises , Including: rolling mill, compressor, circulating compressor, air compressor, steam turbine, high pressure pump ice machine, ball mill, coal mill, motor and other bearings, cross head, slide and other products. YOYIK strict promises, timely supply, in order to sincerity, refinement, durability, and trustworthy for the quality policy, only low-profit, user satisfaction, welcomed the new and old customers come to our factory.

#DF-Air Pressure Regulator 67CFR-600B-DF
pt 100 sensor WZPM-225
BRAUN MONITOR MODULE E1610
static pressure pickup SZCB-01-B01-C1
Eddy Current Sensor PR6422/102-000
Eddy Current Sensor PR6423/003-031
Sensor DF311180-90-03-00
MAGNETIC SPEED SENSOR CS-1 D-065-05-01
Guide Vane Opening DYK-11-1013
Transformer Oil Temperature Measuring Device BWR-906L9
Pressure reducing valve PQ-235C
LVDT transmitter XCBSQ-03/35-02-02
Bolt electric heating rod ZJ-20-7
capacitive linear position sensor DET-300B
DC contactor CZ0-150/20TH
EH OIL PRESSURE HIGH HR307 HHCC
thermocouple with highest temperature limit TE-302
speed sensor UKCSG-01-075-05-01-03-01
prox sensor CWY-DO-810503
Wheel Blade Opening Control LYK-11-1013
Pulse amplifying card A51
float type level gauge UHZ-10C00N4000 S1.00DN25PN1.6V
DF Communication cable RS232
Head tachometer probe ZS-04-180-5000
heating oil tank level gauge UHZ-519C
4 20ma linear position sensor 14000TD 0-700mm
vibration motion sensor JM-B-6Z
Manual Inductor CT1-400A
Speed probe CS-3F-M10-L55-1
tank float level indicator 16062013
contact displacement sensor 4000TDG
panel/monitor vibration transmitter STA 220
Current Transformer LZZBJ9-10C6
speed sensor 143.35.19-1
Eddy Current Sensor PR6423/004-010
PUSH BUTTON ( RAGA ACTUATOR) RA II 14AF14B
Eddy Current Sensor PR6422/105-111
Air Pressure Regulator 67CFR-600B

ZYR-DFYL-2025-2-6
May-29-24
 Inquire Now  
Wearable displacement sensor potentiometer 3000TDZ-A Quality assurance by Yoyik
Deyang YOYIK skill is strong, the production of strict accordance with national standards. With the power station forging, mining metallurgy, rolling, cement and spare parts spare parts, metallurgy, rolling and other products improve the production and operation system. For hundreds of water technology change, hydropower, thermal power plant overhaul supply of high-quality equipment selection, equipment commissioning, construction plans, spare parts, after-sales service, such as through-train service. The company to undertake hydropower stations, thermal power plant unit capacity transformation, technical transformation and overhaul projects. Look forward to the major manufacturers to inquire.

Yoyik can offer many spare parts for power plants as below:

#DF-displacement sensor potentiometer 3000TDZ-A-DF
Eddy Current Sensor PR6423/004-041
PLUG YOX 280
LVDT Sensor 2000TD-E
magnetic pickup sensor generator SMCB-01-16L
Pneumatic Positioner F001798154
Relay HYE41PN24DC
UA Board UA D215 A102 3BHE026284R0102
transmitter CS-â?£
Crusher bearing temperature sensor WZRK-105/�¦5/L=400mm
Pressure relief valve YSF16-55/130KKJ
Transformer Oil Temperature Measuring Device BWR-906L9
Turbine bolt electric heating rod ZJ-17-1
linear position sensor types HL-6-200-15
Bearing Bush Temperature Measuring Element WZPM2-08-75-M16-S
rpm proximity sensor TM301-A02-B00-C0-D00-E00-F00
Regulating valve oil motor displacement LVDT CCH02A.318Z-1
Anti freezing wind direction sensor YH9120-CMM
Transmitter for LVDT 20000TD 0-1000mm
SENSOR, VIBRATION VELOCITY SDJ-SG-2H
thermocouple WREK-231
hydraulic cylinder with linear transducer TDZ-1-35
Servo Position controller DSPC
Ampere Meter HCD194I-9D1
Displacement Proximitor WT0122-A50-B00-C00
Sensor PR6423/010-140+CON021
FUSE 170M6421
Eddy Current Sensor PR6422/002-130
proximity sensor speed measurement TM0180-A07-B00-C04-D05
hydraulic pressure transmitter 460983-QFA015
LVDT transmitter XCBSQ-01/400-01-00
speed sensor CS-1H-G-080-03-02
displacement sensor potentiometer 3000TDZ-A
Jul-29-24
 Inquire Now  
hydraulic gear pump types 2CY-45/9-1A
YOYIK, located in the industrial city of Deyang, Sichuan, is a leading enterprise specializing in the production of power station equipment and accessories. With its excellent manufacturing technology and strict quality management system, it has won wide acclaim in the domestic and foreign markets. The company not only provides key components of traditional power generation equipment such as turbines and generators, but also keeps pace with the times and actively develops products that adapt to new energy trends, such as wind power generation and solar power generation system accessories, and is committed to providing diversified solutions for the global energy industry.

In order to support the operation of the power plant, we have prepared various parts inventory as follows:
#DF-hydraulic gear pump types 2CY-45/9-1A-DF
solenoid valve DG4V 5 2C M U ED6 20
actuator solenoid valve 4WE6E6X/EW220-50NZ5L
O-ring �?25*3.1
5 port solenoid valve 300AA0086A
transformer oil circulation pump F3-20V12A
Filter pressure reducing valve FS-67CFR-600
Guide vane sleeve HPT300-340-04-04
wafer type valve 80DSF4PR3
First stage (second stage) pump casing HPT300-340-04-03(05)
sealing ring HY-SO-0065-V
servo proportional hydraulic valve SF21A
5 2 way directional control valve DG4V-5-2BJ-MU-H6-20
pressure relief valve YSF8-55/130
Spigot Ring P29617D-00 for dome valve DN200 P29617D-00
Inflatable seal- dome valve 200DV (silicone) Poids net 0, 445 P17460C-01
oil pump PVH141R13AF30A230000002001AB01A
variable displacement hydraulic pump for sale PVH74QZC-RSM-1S-1XC25-31
Seal kit-actuators 120 and 129 A1390
hydraulic servo control valve FRD.WJA5.021
pressure relief valve YSF16-35/25-TA
Rotary Feeder YQ-200
valve sealing set 0125ZMAW16KQ13UEXERH
EH oil shock-absorbing pipe clamp SP320PA-DP-AS
Fluorine rubber ring C8689537
Van solenoid 22FDA-K2T-W110R-20/LV
solenoid valve SC8327B102
Gypsum slurry pump SDH150-125-400
Pilot relief valve DB10-2-30/315
24vac solenoid valve GS021600V
pressure relief valve YSF12-35/50-TA
accumulator bladder NXQ-L-10/31.5-A
vacuum pump unit P-1762
Accumulator NXQ-B-L20/10L
valve SDKE-1634/2DC 10S
sewage pump YH50-32-160
Anti-fuel pump outlet pipe 16G2AT-HMP(DN25)*1600DKOL-28-DN25
hydraulic gear pump types 2CY-45/9-1A

hydraulic gear pump types 2CY-45/9-1A

MY-DFYL-2024-7-29
Aug-02-22
 Inquire Now  
2000TD linear differential sensor (Linear variable differential transformer) cá»§a van MSV Spare parts with COO/COM
Dongfang Yoyik is specializing in the production and supply of spare parts of power plant steam turbine, generators, can provide from customized parts to finished factory product. The company regards "scientific management, continuous improvement, quality excellence, customer needs" as the quality of the enterprise policy, and in 2008 passed the ISO9001 quality system certification.
Need more products for power plant? Contact YOYIK now if you don't know where to search a product.
#DF-2000TD linear differential sensor (Linear variable differential transformer) cá»§a van MSV-DF
Regeneration device precision Filter Element filter 01-094-006
O-RING HB4-56J8-180
output speed sensor SZCB-01-00-060-00-05
jacking HP filter SFX-850*20
Brushing Dipping Adhesive 53841WC AB
machin oil filter element XJL0209
Gasket of Bellows Globe Valve LJC100-4.0P
pleated filter cartridge 210LD560K10-WG
oil filter elements HX-160*3W
shaft sealing filter SL12/50
solenoid valve breville dual boiler 4WE-6GE-W240-20
solenoid valve b2015-s85 STERLING HYDRAULICS 230VDC 19W PAT5002253
actuator filter (flushing) JCAJ002
Proportional reversing valve D1FBE32BC0NK7015C10
best oil filter ZL12CX-122/80
hydraulic line filter element STXX-40*30
oil filter cartridge HX-630*30
EH Oil Station Filter Element XJL-03-03
oil filter guide 0330R010BN3HC/-V
centrifugal pump prices KSB65-250A
Automated Back Flushing Oil Filter Cartridge HDX-630*40
transformer oil filter machine ASME-600-150A
excavator filter element TZX-E160*30Q2
2000TD linear differential sensor (Linear variable differential transformer) cá»§a van MSV

Differential Pressure Controller 4NN-EE4-N4-C2A 14~170kPa
hydraulic line filter element ZL366-100*40
dehydration filter SKX-60*10
pressure hose SMS-15-610mm-B
Control oil filter SFX-160*20
cartridge filters 0330D003BN3HC
EH oil pump filter XJL.03.03
vane vacuum pump 0508.1842T1201.AW014
automobile filter element 707DQ1621C732W025H0.8F1C-B
hydraulic filter numbers STZX2-400*5
oil filter cross reference PA684DM25/W
main fuel pump PVH098R01AD30A
Tracking Opening GZK-1010
Filter element of HFO oil tank GY135-200*5
replacement filter HBJP25-15-10
Oil filter element FAX (NX)-40*20
oil filter price Q2U-H25*10S
pp melt blown filter cartridge MSL-31
angle globe valve LJC50-16
oil filter assembly HC1361FKP10H
2000TD linear differential sensor (Linear variable differential transformer) van MSV

DFYL-2022-8-1-ZJ
Aug-03-13
 Inquire Now  
Cuum evacuating, ultimate vacuum value ,161;,220; 5pa
2. Two vacuum separating chambers, efficient oil film sprayer, increasing separating size and separating time to ensure the dry-level and dielectric strength improving greatly.
3. Double-horizontal film evaporation technology, combined with unique and advanced dewatering, degassing components, can rapidly and effectively separate water, gas from oil.
4. Multi-stage precision filtration system, mesh filtration combined with molecular adsorption technologies
5. Efficient electric heating system, heating uniformity, less power consumption, safe, and reliable.
6. Double-infrared liquid level sensor, pressure protective system to ensure machine operation easy and safely.
7. Adopt interlocked protective system, which connect oil pump, heater and liquid level sensor, avoiding blank heating, blank pumping, oil leak and electricity leak. If there is any fault, machine will be power off automatically.
8. Functions of live line work onsite, vacuum drying and vacuum oiling.
,161;,244; advantages
Comparing with single stage transformer oil purifier, series zyd oil purifier can increase the effectiveness more than three times, more quickly and completely dewater, degas, remove particles to get higher dielectric strength. This equipment can be used as independent vacuum source with the functions of vacuum drying and vacuum oiling for the electric plants.



Wooden case
Feb-06-25
 Inquire Now  
ROTATING SPEED MONITOR JM-D-5KF
Deyang YOYIK skill is strong, the production of strict accordance with national standards. With the power station forging, mining metallurgy, rolling, cement and spare parts spare parts, metallurgy, rolling and other products improve the production and operation system. For hundreds of water technology change, hydropower, thermal power plant overhaul supply of high-quality equipment selection, equipment commissioning, construction plans, spare parts, after-sales service, such as through-train service. The company to undertake hydropower stations, thermal power plant unit capacity transformation, technical transformation and overhaul projects. Look forward to the major manufacturers to inquire.

#DF-ROTATING SPEED MONITOR JM-D-5KF-DF
voltage sensor CE-VM01-52MS1-0.2
Power Board SY-V2-POWER (Ver 1.10)
eddy current proximity sensor CWY-DO-816002
Dust-proof ring of adjusting door guide sleeve GSF50
pressure transducer types CS-III
Coil Solenoid R90021396
LVDT Sensor TD-1GN-800-15
Travel switch WLGCA2-TH
PULLCORD SWITCH HKLS-1
Integrated communication terminal ICTes03
analog pressure switch RC771BZ090H
Probe CS-3F-M16*1-L20
different thermometers WSS-401
LVDT Sensor 191.36.09.14
Limit Switch WLGCA2
Armoured Thermocouple WRNK2-101
TACHO METER SZC-04FG
Extension cable 330130-085-02-CN
different types of displacement transducers 3000TD
LVDT Sensor TH-6GN-150-15-01
Pressure Switch 860300
Bearing Reverse Temperature Thermal Resistance WZPK2-380B
transformer oil level indicator DYW-250
Thermostat Pinhole Lens DXTV600B
Electromagnetic Speed Controller DEC8505D
pressure measuring machine BH-053003-053\500~4000PSI
Tracking Opening GZK-1010
PLC module NFLR121-S00 S50
MOV module A144I, A144I BZ-K2-3J 141010430
Eddy current probe 330901-00-12-70-12-CN
speed sensor G-065-08-01
ROTATING SPEED MONITOR JM-D-5KF

ZYR-DFYL-2025-2-6
Aug-04-03

Transformer Oil

$0.10
MOQ: Not Specified
Supplier From Bangkok, Minburi, Thailand
 Inquire Now  
Transformer oil
Used transformer oil at 100 ton/month

200ltrs steel drum
Mar-11-19
 Inquire Now  
Gas Dew Point Detection Instrument/Trace Water Content Tester
Transformer Oil Tester

Application:
Dew point uses imported alumina or polymer film capacitive dew point sensor. It measures the trace moisture content in various trace gases. It is suitable for some online analysis occasion where the moisture content control requirement is quiet strict such as petrochemical, natural gas, industrial gas, semiconductor industry, drying industry, food industry, power industry, machinery manufacturing, air separation industry, and pharmaceutical industry.

dew point tester Feature
Portable design:light,portable,convenient to use.
Rapid measurement:when start work,it takes a short time on measurement,and get the humidity value.
Low gas consume:it just consume 2L(101.2kPa)in a test.
Self-locking joint:the self-locking joint is imported from Germany,safe,reliable,leakproof.
Data memory:high-capacity design,save up to 50 test data.
Legible display:dew point,Micro moisture(ppm),ambient temperature,ambient humidity,time,date,battery,etc,can be read from the LCD.
RS232 port:can be connected with serial printer,carry on data printing.
Built-in power supply:built-in 4Ah rechargeable lithium battery,it can work continuously at least 10 hours.

dew point tester Specification
dew point Ranges -60 ~+20
Accuracy ±1(-60~+20)
Test time(+20)
May-14-13
 Inquire Now  
Series zyd insulating oil purifier is double-stage transformer oil purifier can quickly remove water, trace water, gas, particles as well as acetylene, hydrogen, methane and other harmful ingredients from oil effectively to improve oil's dielectric strength, effectively making sure electric equipments working safely and normally. Series zyd oil purifier is particularly suitable for treating high-grade transformer oil, super-voltage transformer oil and new transformer oil. It can be used for filtration of more than 110v substation live line work onsite. Meanwhile, series zyd oil purifier can be used as independent vacuum source with functions of vacuum drying and vacuum oiling.
Features:1. Double-stage vacuum system
Two vacuum separating chambers, efficient oil film sprayer
3. Duplex-stereo film evaporation technology, combined with unique and advanced dewatering, degassing components
4. Multi-stage precision filtration system, mesh filtration combined with molecular adsorption technologies5. Efficient electric heating system
6. Double-infrared liquid level sensor, pressure protective system

Delivery: sea, air, railway
Lead time: 15 days
Price term: fob shanghai
Payment term: tt/lc/da/dp
Minimum order: 1 set
Packing: wooden case
Standards certificate: ce certificate iso9001

Quality makes living. Top will spare no effort to provide you products of superior quality and best services.
Mr jason wang:8615215071486 86-23-68677712 86-23-88901306
Skype: dadawandouge msn:wandouge
You are welcome to visit our web site: www. Topoilpurifier.Com

Wooden case
May-06-13
 Inquire Now  
1. Double-stage vacuum system
2. Two vacuum separating chambers, efficient oil film sprayer
3. Duplex-stereo film evaporation technology, combined with unique and advanced dewatering, degassing components
4. Multi-stage precision filtration system, mesh filtration combined with molecular adsorption technologies
5. Efficient electric heating system
6. Double-infrared liquid level sensor, pressure protective system

Delivery: sea, air, railway
Lead time: 15 days
Price term: fob shanghai
Payment term: tt/lc/da/dp
Minimum order: 1 set
Packing: wooden case
Standards certificate: ce certificate iso9001


Wooden case
Aug-05-21

Transformer Oil Dielectric Strength Tester

$770 - $15.40K
MOQ: Not Specified
 Inquire Now  
Overview

Many power systems, railway systems, large-scale petrochemical plants and enterprises have a lot of electrical equipment whose internal insulation are mostly oil-filled insulation type, and therefore, test on insulating oil dielectric strength is common and necessary. To meet the needs of the market, we have developed and produced a series of insulating oil dielectric strength testers according to national standard GB/T507-2002, industry standard DL429.9-91 and the latest Electric Power Industry Standard DL/T846.7-2004 by ourselves. This instrument, by using a single-chip microcomputer as the core, can operate in full automation with high accuracy, greatly improving work efficiency and reducing the labor intensity of workers. Moreover, it is small in size and convenient to carry.

Major Technical Indicators
1. Output voltage: 0-100KV (optional)

2. Voltage distortion rate: 3%

3. Voltage raising speed: 0.5-5 KV/S (adjustable)

4. Standing time: 15min (adjustable)

5. Boosting interval: 5 min (adjustable)

6.Boosting frequency: 1-9 time(s) (optional)

7. Booster capacity: 1.5KVA

8.Measuring accuracy: ±3

9. Supply voltage: AC220V ±10%

50Hz±1 Hz

10. Power: 200W

11.Applicable temperature: 0-45

12.Applicable humidity: 75%RH

13. Overall dimension: 465 385 425
Jul-10-21

Transformer Oil Bdv Tester (Three Cups)

$770 - $152.40K
MOQ: Not Specified
 Inquire Now  
Product Characteristics
1. Dielectric strength tester for insulation oil use large capacity single-chip microcomputer control stable and reliable work
2. Dielectric strength tester for insulation oil there is the function of temperature and humidity in time clock display and is equipped with grounding alarm to remind customers pay attention to safety
3. Dielectric strength tester for insulation oil has a wide range of watchdog circuit to eliminate the phenomenon of crash
4. Multiple operating option Dielectric strength tester for insulation oil program with GB1986 GB2002 two methods of national standard and custom operation able to adapt to a variety of different users choice
5 Dielectric strength tester for insulation oil oil cup is made of a special glass casting forming to eliminate the phenomenon of oil and other interference
6. Dielectric strength tester for insulation oil special high voltage side sampling design for test values directly into the A/D converter to avoid the error caused in the analog circuit makes the measurement more accurate
7. Dielectric strength tester for insulation oil inside has over current over voltage short circuit protection and other functions and with a strong anti-jamming capability good electromagnetic compatibility
Jul-09-21

Transformer Oil Bdv Tester (Single Cup)

$770 - $15.40K
MOQ: Not Specified
 Inquire Now  
Product Introduction
In the power system factories and enterprises have a large number of electrical equipment. Most of its internal insulation is oil-filled insulation type. Dielectric strength test of insulating oil is a necessary routine test item. In order to adapt to the rapid development of the power industry our company is the first in China to develop a fully automatic oil dielectric strength test system. This series of products according to the latest national standard GB/ t507-2002 the power industry standard dl429.9-91 and the latest power industry standard DL/ t846.7-2004 design and manufacture using microcomputer control mechanical and electrical integration of all automation high test accuracy greatly improve the work efficiency but also greatly reduce the labor intensity of the staff. It is agreed that this series of products is the ideal insulation oil voltage test equipment in China.

Product names insulation oil tester oil pressure tester insulated oil pressure tester oil dielectric strength tester insulation oil dielectric strength tester insulation oil pressure tester automatic insulation oil tester microcomputer automatic insulation oil tester automatic oil tester automatic oil tester portable oil pressure test device electrical strength tester
Jul-31-21

Transformer Oil Flash Point Tester

$770 - $15.40K
MOQ: Not Specified
 Inquire Now  
Product description

Transformer oil flash point tester is used to determine the flash point value of petroleum products. The instrument adopts electric ignition mode without any flammable gas and meets the requirements of GB3536-2008 and GB267-88. Moreover, it utilizes many kinds of latest technologies such as ARM series high-performance microprocessor, electric erasing memory (can store thousands of data records), 7-inch color liquid crystal display and touch screen and PID self-tuning, etc.



Technical index

Test range: 40~400

Test type: Open flash point

Temperature detection: Platinum resistance

Accuracy: ±1

Repeatability: Meet GB3536-2008 and GB/T 267-88

Display: 7-inch touch screen and colorful LCD

Information storage: 1000 test results can be stored

Ignition method: Electronic ignition

Cooling method: Forced air cooling

Atmospheric pressure: Automatic detection of atmospheric pressure, automatic correction of test results

Printer: Dot matrix thermal printer

Self-check function: Lift lever, scratch lever, printing, etc.

Power: 600VA

Power supply: (AC) 220V ±11V frequency: 50Hz ±2.5Hz

Ambient temperature:10~35

Ambient humidity: 90%

Packaging weight: about 17kg
May-30-17

The Waste Oil Decolor And Reanimate

$30.00K
MOQ: Not Specified
 Inquire Now  
The waste oil decolor and reanimate Primary useHD - 1 series multi-function is a high-efficient decolorizing huadu long gold machinery equipment co., LTD., the latest patent product (patent no. 200920090989.4), in addition to containing series vacuum filter oil machine at home and abroad all function, also have decolorizing, regeneration, and other functions. Applicable to the cement, chemical fertilizer, chemical, petroleum, metallurgy, mining, power, shipbuilding, machinery, military industry, rubber, instrumentation, transportation, building materials, paper and other industries of all kinds of liquid and solid waste oil regeneration process. Especially for oil serious aging, the phenomenon such as color change after the purification treatment equipment, can achieve or close to the country's new oil standards, fully meet the use requirements of the recovered oil.
HD - 1 series multi-functional efficient decoloring to life again by chemical treatment system, oil and water separation system, break emulsion separation system, decoloring regeneration system, the cooling system, filtering system and electric control system, etc. It is not only suitable for the reproducing and decoloring reduction of the low grade oil combustion engine. It can also deal with other kinds of waste oil regeneration and decoloration (such as degraded transformer oil, switching oil, insulation oil, sewing machine oil, etc.).Second, characteristic introduction 1, this equipment adopts the physics, chemistry, elimination of waste oil in polarity between micro particle charge, make them together into larger particles surface impurities by precipitation, the glue and removing oil, asphalt, and various compounds. At the same time through the exhaust cleaner and vacuum dewatering, degassing effect, remove the harmful gas and water, can not only remove the inferior oil in the acidic ingredients, suspended substance, precipitation, and make inferior oil regeneration.
2, use a special kind of renewable cleanser and make the processed oil does not damage the basic composition and the oxidation resistance, oil to meet the new standards, at the same time improve the performance of the insulation of the equipment and safety.
The equipment is equipped with advanced hydraulic magnetic automatic control system, which completely solves the oil pump and running oil in the oil filter. Additionally, there is an advanced pressure automatic controller, which can automatically stop when the equipment overpressure and prevent the machine
Jul-15-24

Phenolic Paper Laminated Sheet

$1.95 - $2.20
MOQ: Not Specified
 Inquire Now  
The product is made of an insulating impregnated paper soaked with phenolic resin, through baking, hot pressing. Application: The product is suitable for high performance requirements of electrical machinery,
electrical equipment as insulating structural parts, and can be used in transformer oil.Appearance: The surface should be smooth, does not allow any impurities and other
obvious defects, allow a slight abrasions. Edge should be cut neatly, and face may not
have hierarchical crack.
Nominal thickness: 0.2mm~60mm
Jul-25-18
 Inquire Now  
FDH-1001 Transformer Oil Oxidation Stability Tester
Scope
The instrument uses advanced contemporary technology, set machinery, optical electronics and computer technology in one, it can be temperature measurement, temperature control. Temperature control accuracy and stability.
The instrument structure is reasonable, stable performance, simple operation, it is the ideal analysis and testing equipment.

Features
1, constant temperature metal bath system:
The use of aluminum as a bath, to avoid oil pollution and oil and gas pollution, but also to avoid accidents.
2, the temperature control system:
Using intelligent temperature controller with microprocessor, with self-tuning, self-diagnosis function, PID three parameters to adjust the temperature, auxiliary heating automatically shut down, so high precision temperature control, stable and reliable performance.
3, with six test baths, both for a sample test can also be up to six samples of the test, convenient and flexible.
4, equipped with six flow meters, can be adjusted and directed into the six oxidation tube gas flow.
5, equipped with digital timer, used to set and record the test time.

Technical Parameters
1, the power supply: AC220V 50Hz, power consumption: â?¤ 1100W.
2, temperature control mode: digital temperature control table automatic temperature control.
3, temperature range: room temperature ~ 160 â??,
4, temperature control accuracy: set temperature ± 0.2 â??.
5, temperature components: thermal resistance.
6, the number of samples: 6 Road, at the same time for six samples.
7, the heating method: metal bath
Jul-28-17
 Inquire Now  
Scope
Test standards: astm d1816, astm d877.
This instrument uses special hardware and software anti-interference technology, it can work in a strong magnetic field environment, and widely used in power, oil and research departments.

Features
1. The instrument uses a microprocessor, three cups of whole, auto-complete boost, hold, stirring, static discharge, calculate, print and other operations, oil circulation pressure test can be carried out within 0-80kv range.
2, large-screen lcd, english menu, easy to operate.
3, this instrument is simple to operate, the operator simply simple setup, the instrument will automatically complete the 1-3 oil sample pressure test in accordance with the setting. Each oil sample, each cycle of breakdown voltage and frequency are automatically stored, after completion of the test, a thermal printer can print out the voltage value of each oil sample breakdown various times and average.
4, retentive, it can store 100 test results and can display the current ambient temperature and humidity.
5, using scm control uniform boost, voltage frequency accuracy of 50hz, making the entire process easy to control.
6, overvoltage, overcurrent, limit and other protection to ensure the safety of the operator.
7, having a temperature measuring and display function displays the system clock.
 
Technical parameters
1, the test voltage: 0-80kv (optional)
2, the voltage distortion:
Aug-25-16
 Inquire Now  
Scope
This equipment according to GB/ T507 and industry standards DL429.9 national standard GB designed and manufactured, using a special software and hardware anti-jamming technology, can work in strong magnetic field environment, widely used in electricity, oil and scientific research departments .

Features
1. The instrument uses a microprocessor, three cups of whole, auto-complete boost, hold, stirring, static discharge, calculate, print and other operations, oil circulation pressure test can be carried out within 0-80KV range.
2, large-screen LCD, English menu, easy to operate.
3, this instrument is simple to operate, the operator simply simple setup, the instrument will automatically complete the 1-3 oil sample pressure test in accordance with the setting. Each oil sample, each cycle of breakdown voltage and frequency are automatically stored, after completion of the test, a thermal printer can print out the voltage value of each oil sample breakdown various times and average.
4, retentive, it can store 100 test results and can display the current ambient temperature and humidity.
5, using SCM control uniform boost, voltage frequency accuracy of 50HZ, making the entire process easy to control.
6, overvoltage, overcurrent, limit and other protection to ensure the safety of the operator.
7, having a temperature measuring and display function displays the system clock.

Technical Parameters
1, the test voltage: 0-80KV (optional)
2, the voltage distortion:
Mar-18-16
 Inquire Now  
Product Description
According to user's requirements, we developed series ZYM trailer type insulating oil purification plant, this machine is mainly used for dealing with unqualified transformer oil, switch oil, mutual inductor oil, ZYM belongs to double-stages transformer oil purification, it can quickly remove water, trace water, gas, particles as well as acetylene, hydrogen, methane and other harmful ingredients from insulating oil effectively to improve insulating oil's dielectric strength, effectively making sure electric equipments working safely and normally. Series ZYM oil purification is particularly suitable for treating high-grade insulating oil, super-voltage insulating oil and new insulating oil. It can be used for filtration of more than 110V substation live line work onsite. Meanwhile, series ZYM oil purification can be used as independent vacuum source with functions of vacuum drying and vacuum oiling. The best advantage of ZYM is that can move long distance working in field.





wooden case
May-25-16
 Inquire Now  
Product description
According to user's requirements, we developed series zym trailer type insulating oil purification plant, this machine is mainly used for dealing with unqualified transformer oil, switch oil, mutual inductor oil, zym belongs to double-stages transformer oil purification, it can quickly remove water, trace water, gas, particles as well as acetylene, hydrogen, methane and other harmful ingredients from insulating oil effectively to improve insulating oil's dielectric strength, effectively making sure electric equipments working safely and normally. Series zym oil purification is particularly suitable for treating high-grade insulating oil, super-voltage insulating oil and new insulating oil. It can be used for filtration of more than 110v substation live line work onsite. Meanwhile, series zym oil purification can be used as independent vacuum source with functions of vacuum drying and vacuum oiling. The best advantage of zym is that can move long distance working in field.
May-25-16
 Inquire Now  
Product description
Zy single-stage vacuum transformer oil filtration, mainly for the power station, industrial and mining enterprises purifying the unqualified transformer oil, mutual inductor oil, switch oil and so on. Series zy can remove water, trace water, gas, particles from transformer oil quickly and effectively, improving oil dielectric strength. Also, it can be used as vacuum drying and vacuum oiling for power equipments.
Sep-27-18
Supplier From Zhengzhou, Henan, China
 Inquire Now  
Process: Phenolic laminated paper board (bakelite, phenolic board) is made from phenolic resin, impregnated paper soaked with phenolic resin under high temperatures and pressures.

Performance: It has higher mechanical properties and electrical properties.

Application: Phenolic paper sheet is widely used for transformers, electric motors, electric switches etc., used as all kinds of insulation parts. It is also can be used in transformer oil.
Jul-20-18

Transformer Oil

$85
MOQ: Not Specified
Supplier From Jaipur, Rajasthan, India
 Inquire Now  
transformer oil
Sep-27-18
Supplier From Zhengzhou, Henan, China
 Inquire Now  
Introduction:

Basic Materials: Insulation paper and phenolic resin

Specifications:

Performance: Good dielectric property under dry state and good mechanical strength

Color: Brown

Standard: IEC UL

Application:

Insulating structural parts of electrical apparatus in transformer oil
Sep-27-18

Electrical Paperboard & T4 Paperboard

$1
MOQ: Not Specified
Supplier From Zhengzhou, Henan, China
 Inquire Now  
Description:
Electrical paperboard is made of sulfate wood pulp with 100% purity processed by high-pressure. It has high mechanical strength, and high compatibility with the transformer oil. It is widely used on oil-immersed transformers, electric reactors, capacitors and switches, etc.
T4 cardboard has high density, higher tightness, lower shrinkage and good flatness. It is mainly used on equipment such as transformers, capacitors, mutual inductor, etc.( namely oil clearance pad of pie winding , partition board, cardboard tube, corrugated paper, iron yoke insulation, clip insulation, end insulation, winding plate, etc.)
Specifications: Thickness: 0.5/1/2/3/4/5mm Long * Wide: 1000*2000 Weight for Each Package: 500Kg
Jun-03-26
Supplier From Sharjah, , United Arab Emirates
 Inquire Now
484 Transformer Oil Suppliers
Short on time? Let Transformer Oil sellers contact you.
See what buyers and suppliers are discussing in Transformer Oil import export community