High efficiency high flux density carbon infrared heating lampscarbon medium wave infrared lamps features: wavelength range of carbon red heating ir heater: 2.5-2.7 um. cross sectionof carbon red heating ir heater: 33*15mm twin tube diameter.Applied industry: printing painting drying, powder coating drying, paint drying, plastic heating and drying, thin film strecthing, etc.Carbon red heating ir heater model cfir332620wlamp model: cfir332620wquartz tube: white coatinglamp length: 2620mmactive length:2500mmvolatge:400vpower: 6250wcable length: 500mm one side outcolor temperature: 1800-2400kwavelength of ir radiation: 2.5-2.7umcarbon red heating ir heatermax heated length 3200mmmax total length 3400mm;max power output: 9000-12000w;max voltage: 600v;average lifetime of carbon red heating ir heater: 10, 000 hourspart no. voltagewattagetwin tubetotal
transparent high purity quartz heater tube transparent high purity quartz heater tube is one of infrared heating element, which is the most efficient and mostenergy-saving type in the heating area. It can not only improve your heating speed by higher power, but also it will help you save more enrgy by using the shortwave infrared heater to replace the other heaters. transparent high purity quartz heater tubelamp model: swir-10500tube coating: golden reflectorlamp length: 500mmactive length: 440mmvolatge: 220vpower: 800wcable length: 600mmcolor temperature: 2000-2700kwavelength of infrared radiation: 0.75-1.4um ir benefits and features long lifemore than 5000h high speedwithin 1 second to switch onhigh efficiencymore than 85% heat efficiency of full powerhigh power densityup to 200w/cmhigh control abilityneither ballast nor special circuits are necessary for basic usageno air droughtsbecause of radiation(like solar energy)clean and odorlessno risk of contamination over environment or target object to be heatedextensive assortmentmany types of voltage, wattage, length, base, cables, horizontal
Ishcanto ixd47-63 series miniature circuit breaker is made of plastic shell, operating mechanism, contact arc system, tripping mechanisum and other components. The shell is made of high-strength special plastic, with strong impact capability and light wieght.
Feature: short circuit protection
Isolation function
Overload protection
Control
Product Description :
Modular Circuit Breakers - xC60. Breaking Capacity as per IEC 60947-2, Icn = 15kA, upto 40A, Higher Installation Life : Energy limitation class: 3, Tropicalization: T2 - relative humidity 95% at 55C. Higher performance by Low cost : Cascading. Increase system continuty : Discrimination. Reference Temperature of 50C as per IEC60947-2.
Product Specification:
Brand - Schneider
Model Name - A9N2P01C
Current Rating - 1A
Pole - Two Pole
Rated operational voltage - 100V - 125V DC, 240V AC 50/60 Hz, 380V - 415V AC 50/60 Hz
Rated service breaking capacity - 6kA conforming to EN/IEC 60947-2, 100V - 125V DC, 7.5kA conforming to EN/IEC 60947-2. 380V - 415V AC 50/60Hz
Mcb range offer the possibility to select among different characteristics (b, c, d), configurations (1p, 1p+n, 2p, 3p, 3p+n, 4p), breaking capacities (up to 15 ka) and rated currents (up to 125a).
Miniature circuit breakers protect installations against overload and short-circuit, warranting reliability and safety for operations. They have two different tripping mechanisms, the delayed thermal tripping mechanism for overload protection and the magnetic tripping mechanism for short circuit protection.
ï?? Extra-wide and complete range of MCBs to cover most applications and markets
ï?? Meeting worldwide standards
ï?? Certificates, documentation, training or background information to support customers due to their daily work
ï?? Space and time saving thanks to frame degree updates
Main features
MCB range offer the possibility to select among different characteristics (B, C, D), configurations (1P, 1P+N, 2P, 3P, 3P+N, 4P), breaking capacities (up to 15 kA) and rated currents (up to 125A).
Compliance to the worldwide standards,
IEC/EN 60898-1
IEC/EN 60947-2
IEC/EN 60947-3
IEC/EN 61009-1
GB10963.1
GB1096.1
GB14048.2
GB14048.3
GB16917.1
Allowing the use for residential, commercial and industrial applications 25 mm2 and 10 mm2 cylinder lift twin terminals for challenging industrial use. Cross Real contact position indication, directly connected to the moving contact, for more comfort and safety
ï?? Environmental
Ambient Air Temperature: Operation -5 ... +55°C Storage -40 ... +70 °C
Resistance to Shock acc. to IEC 60068-2-27: 30g / 2 shocks / 13 ms
Resistance to Vibrations acc. to IEC 60068-2-6: 5g, 20 cycles at 5 ... 150 ... 5 Hz
Environmental Conditions: 28 cycles with 55 °C / 90-96 % and 25 °C / 95-100 %
Technical Standards: IEC/EN 60898-1
Rated Current (In): 6A, 10A,16A, 20A, 25A, 32A, 40A, 50A, 63A, 80A, 125A
Rated Operational Voltage: acc. to IEC 60898-1 230 V AC & 400V AC
Rated Insulation Voltage (Ui): acc. to IEC/EN 60664-1 440 V
Rated Frequency (f): 50 Hz 60 Hz
Rated Ultimate Short-Circuit Breaking Capacity (Icu): (230V AC & 400V AC) 15 kA
Rated Service Short-Circuit Breaking Capacity (Ics): (230V AC & 400V AC) 6 kA
Instantaneous release: Type C: Lighting protection ; Type D: Motor protection
1.General
HVD85 ZN85 33kv 36KV indoor vacuum circuit breaker VCB is suitable for three-phase AC power system of 50Hz and 36kV, used to make and break the load current, overload current and fault current in industrial and mining enterprises, power plants and transformer substations, meanwhile, it is suitable for the occasion where the frequent operation is required.
2. Service conditions
2.1The ambient air temperature should be -15?~40?, the daily average temperature should not exceed 35?.
2.2 Daily mean relative humidity should not exceed 95%, and the daily mean vapor pressure should not exceed 2.2kPa; the monthly mean relative humidity should not be higher than 90%, and the monthly mean vapor pressure should not exceed 1.8kPa.
2.3 Altitude: Not exceed 1,000m.
2.4 The ambient air should be free from the dust, smoke, corrosive and flammable gas, steam, salt fog, et…
Main specifications and technical parameters
Rated voltage: 33KV 36kv
Power frequency withstand voltage: 95 kv
Lighting impulse withstand voltage: 185 kv
Rated current: 1250A, 1600A, 2000A
Rated short-time withstand current: 25KA, 31.5KA
Rated peak value withstand current: 63KA, 80KA
Rated short-circuit duration: 4 s
Rated short-circuit breaking current: 25KA, 31.5KA
Rated short-circuit making current: 63KA, 80KA
Rated operation sequence: O-0.3s-CO-180s-CO
Breaking time:
1. General
VS1 12KV vacuum circuit breaker VCB
HVD1-12(VS1-12) type indoor AC HV vacuum circuit breaker VCB (hereinafter referred to as circuit breaker) are suitable for 12kV air-insulated indoor switchgears, used as protection and control unit of power equipment of industrial& mining enterprise. Due to the super excellence, it is especially for location where requires the frequent operation of rated working current or multi breaking short circuit current.
The circuit breaker adopts the integrated design of operating mechanism and circuit breaker body, servers as not only fixed installation, but also the handcart unit through equipping with a special propelling mechanism.
2. Service conditions
3.1 Environment temperature:-15degree~+40degree;
3.2 Environment humidity: Daily average relative humidity:
1. Introduction
HVD7 33KV 36kv outdoor HV AC vacuum circuit breaker VCB has many visual advantages like reasonable design, fashionable appearance, high safety and reliability, simple maintenance, long electric life. It is the ideal upgraded products of 35KV outdoor oil circuit breakers.
HVD7-40.5 vacuum circuit breaker is applicable for three-phase power system of AC 50HZ.It is used to make and break the load current ,overload current and short-circuit current.
2. Applicable environment
3.1The ambient temperature should be -30degree~ +40degree(-40degree in the frosty area);
3.2Altitude should not exceed 2000m(over 2000m is plateau type);
3.3The wind pressure should not exceed 700Pa(equal to wind speed 34m/s);
3.4Air pollution degree: 3,that of antifouling type:4;
3.5The installation site should be free from the fire, explosion, chemical corrosion and serious vibration.
1. Main technical parameters
Rated voltage: 33kv 36KV
1 minute power frequency withstand voltage, dry test: 95 kv
1 minute power frequency withstand voltage, wet test: 80 kv
Lightning impulse withstand voltage(peak value): 185 kv
Rated current: 1600A / 2000A
Rated short-circuit breaking current: 20KA, 25KA, 31.5KA
Rated short-circuit making current(peak): 50KA, 63KA, 80KA
Rated operating sequence: O-0.3s-CO-180s-CO
Rated short-time withstand current: 20KA, 25KA, 31.5KA
Rated peak withstand current: 50KA, 63KA, 80KA
Rated short-circuit duration: 4 s
Rated control voltage: AC220,110;DC220,110
Rated short-circuit breaking current break times: 20 times
Full-break time:
1. General
HVD32 ZW32 This vacuum circuit breaker VCB is three-phase AC 50Hz, rated voltage 12 kV outdoor high voltage switch equipment. It is mainly used to opening(closing) load current, overload current and short-circuit current. It is suitable to protect or control the city or village electrical power distribution system.
2 . Main technical parameter
Rated voltage: 12 kv
1 minute rated power frequency withstand voltage: Phase to Phase, to Ground 42 kv / Fracture 48 kv
Rated current: 630A / 1250A
Rated short circuit breaking current: 12.5KA, 16KA, 20KA / 25KA
Rated short-circuit current (peak): 31.5KA, 40KA, 50KA / 63KA
Rated peak withstand current: 31.5KA, 40KA, 50KA / 63KA
4s rated short time withstand current: 12.5KA, 16KA, 20KA / 25KA
Rated operating sequence: O-0.3s-CO-180s-CO(Electric operation)
Closing time: 30-60 ms
Opening time: 20-40 ms
Rated short circuit breaking current breaking times: 30 times
Mechanical life: 10,000 times
Secondary circuit 1 minute power frequency withstand voltage: 2000 v
Energy storage motor rated power: 40 w
Energy storage motor rated voltage V: DC220/110
Rated closing operation voltage v: DC220/110, AC220/110
Rated switching operation voltage v: DC220/110, AC220/110
Electric energy storage time: =8 s
Our MCB is an automatically operated electrical switch. Miniature circuit breakers are intended to prevent damage to an electrical circuit as a result of excess current. They are designed to trip during an overload or short circuit to protect against electrical faults and equipment failure.
Residual Current Circuit Breaker or RCCB is basically a gadget that senses current and disengages any low voltage (uneven current) circuit whenever a fault occurs. The main purpose of installing a Residual Current Circuit Breaker fundamentally is to protect people from electric shocks or death caused by them.
The 10KA MCB features an elegant and distinctive design, offering dual protection against both short-circuits and overloads.
Feature of JVM66-63-C 10ka MCB
Notable for its fine and distinctive appearance.
Provides dual protection against both short-circuits and overloads.
Boasts an impressive high-breaking capacity of 10KA, surpassing similar products worldwide.
Features a distinct label and a transparent window for added convenience.
Offers a convenient and dependable installation method.
Specification of JVM66-63-C 10ka MCB
Model: JVM66-63-CPole No.:1P, 2P, 3P, 4P
Rated current:1,2,3,4,6, 10,13,16ï¼?20,25,32,40,50,63ARated working voltage:240/415V
Rated frequency: 50/60Hz
Rated frequency (miniature circuit breaker):400VCurve (miniature circuit breaker):B,C,D
High short-circuit breaking capacity:10000A(10KA)
lnstantaneous tripping current:5In (B type)10In (C type) 20In (D type)
Instantaneous non-tripping current:3In (B type) 5In(C type)10ln(D type)Mechanical life:10000 times
Degree of protection: IP20wiring mode:Front wiring
Connecting conductor:Up to and including 16m2Wiring height:21.5mm
Miniature Circuit Breaker Automatic Assembly and inspecting line
MCB Automatic Assembly and inspecting line
Keyword: Miniature Circuit Breaker Automatic Assembly, Miniature Circuit Breaker, Automatic Assembly line, Assembly Machine, Assembly Production Line
Product Introduction
Basic operation process:
ï?¼Loading by AGV robots, printing QR codes based on the product work order issued by the SAP system, and then separating the upper and lower shells.
ï?¼Bottom coating of the upper shell: The installation of three components is completed through ten processes, and after each assembly is completed, there is a corresponding installation accuracy testing process to ensure that the assembly is completely qualified.
ï?¼Installation of lower shell components, upper and lower shell assembly: A total of 25 processes are used to install 12 components. After each part is assembled, guide pins are used to ensure the upper and lower assembly. After the installation of internal components is completed, the product's on/off function is tested. After passing the test, rivets are installed, pressed again, and the screws are removed. All installations are checked, and after passing the test, they are transferred to the inspection station.
ï?¼Unipolar products undergo instantaneous detection, delay detection, cooling tower and other unit inspections, and are then labeled with QR codes and covers before being transferred to the next workstation.
ï?¼Multi pole products require 9 steps of multi pole assembly, and after assembly, a second delay is performed to verify the stability and reliability of the product
ï?¼Finally, it is transferred to the automatic packaging unit through pressure resistance testing, transfer printing, laser labeling, and buckle installation.
The specific parameters:
(1) Equipment input voltage: 220V �± 10%, 50Hz;
(2) The equipment has functions such as automatic shell loading, lid opening, assembly of arc extinguishing plates, magnetic guide plates, handle springs, base springs, positioning pins, handles, jump buckles, locks, coil components, iron core components, wiring columns, adjustment screws, arc extinguishing covers, CCD recognition, lid closing, identification of qualified and unqualified products, assembly of cutting processes, online detection, real-time monitoring, component life monitoring, data storage, MES system and ERP system networking, parameter arbitrary formula, smart energy analysis and energy-saving management system, intelligent equipment service big data cloud platform, etc.
(3) Theoretical production effeciency: 2 seconds per unit; Daily production of approximately 14400 pieces/8 hours;
(4) This device has the function of power-off to save data for 30 days, making it easy to manage production data;
(5) This device adopts touch screen operation, has a computer communication interface, and printing function