MS150 Series multi-channel temperature monitor is a multi-point temperature measurement instrument. It takes the highest measured temperature in measuring loops as its output signal which is sent out in the form of a 4 to 20 mA standard current signal and the temperature is displayed by the built-in LED. If required, temperature at any measuring point can be shown by operating the keys on panel. Isolation is provided between the input and output.
It is mainly used in the applications of multi-point temperature measurement or alarm warning system. By adopting SMT technology, it offers excellent accuracy, reliability and anti-disturbance.
Primary Technical Characteristics
Measuring range 0¡«100¡æ¡¢0¡«150¡æ¡¢0¡«200¡æ
£¨according to user's demand£©
Input type Pt100,Cu50£¨TC if specially required£©
Measuring Points 2,3,4,5,6 points
Convert accuracy ¡Ü0.5£¥FS
linearity error < 0.1%
Output 4¡«20mA Electrical isolation output
Digital display LED
Display accuracy 0.5%
Voltage drop for display 3V
Isolated voltage Drop 2V
Isolate Voltage 1500V AC (Input/Output¡¢with isolator)
Max-load £¨V -14V~16V£©/0.025A£¨Current output £©
Limit current ¡Ü25mA
Response time 1s
Power supply 14~30V DC
Temperature draft 0.025% FS/ 1¡æ
Long-term stability ¡Ü0.1¡æper year or 0.05£¥ per year
Ambient -40~+85¡æ£¨Aluminium alloy .Casing£©
-25 ~+75¡æ£¨Plastic Casing£©
Protection level IP66£¨Aluminium alloy£©/IP62£¨Plastic£©
Anti-RFI >10v/m(80MHz¡­¡­1000MHz).


Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: Multi-Channel Temperature Monitor

Oct-17-11
 
MS182 is a smart in-head transmitter module with HART® -protocol. It has measurement input for resistance Thermometers (RTD), thermocouples, resistance or millivolt signals in 2-, 3- or 4-wire connection, and converts various input signals into a standard 4 to 20 mA analog output signal after linear processing. The transmitter is programmable directly from PC or via the HART communication. Isolation is provided between the input and output. A special signal can be set in advance while the sensor burnout or short.
Primary Technical Characteristics
Programmable Use PC or the hand operator
Measuring range Set via PC or by the hand operator
Input type RTD, TC, R or Millivolt signal
Convert accuracy 0.1£¥FS
Cold junction accuracy ¡À1(TC)
Output 4¡«20mA/20¡«4mA Electrical isolation output
HART ¨CProtocol output
Max-load £¨V -13V£©/0.025A£¨Current output £©
Limit current 25mA
Response time 1s
Isolated voltage 1500V AC (input/output)
Alarm signal Programmable
Underranging linear drop to 3.8 mA
Overranging linear rise to 20.5 mA
Sensor break or short-circuit:
3.6mA or ¡Ý21.0mA
Power supply 13¡«30V DC
Temperature drift 0.01£¥ FS/1
Long-term stability 0.1 per year or 0.05 £¥per year
Ambient -40¡«+85.
Oct-17-11
 
MS181 is an intelligent temperature transmitter module which can be programmed through a PC with Configuration Kit. It has measurement input for resistance thermometers (RTD) ,thermocouples, resistances or millivolt signals in 2-,3- or 4-wire connection, and converts various input signals into a 4~ 20mA analog output signal after linear processing. Isolation is provided between the input and output. A special signal can be set in advance while the sensor burnout or short.
Primary Technical Characteristics
Programmable Use the MS181 programming tool
Measuring range Set via PC
PC Interface USB/RS232
Input type RTD, TC, R or Millivolt signal
Convert accuracy ¡Ü0.1£¥FS
Cold junction accuracy ¡À1(TC)
Output 4¡«20mA/20¡«4mA Electrical isolation output
Max-load £¨V -8V£©/0.025A£¨Current output £©
Limit current ¡Ü25mA
Response time 1s
Isolated voltage 1500V AC (input/output)
Alarm signal Programmable
Underranging linear drop to 3.8 mA
Overranging linear rise to 20.5 mA
Sensor break or short-circuit:
¡Ü3.6mA or¡Ý21.0mA
Power supply 8¡«30V DC
Temperature drift 0.01£¥ FS / 1
Long-term stability ¡Ü0.1 per year or 0.05£¥ per year
Ambient -40¡«+85
Oct-17-11
 
MS183 , a smart 2-wire in-head and dual-input transmitter module with HART® -protocol, has measurement input for resistance Thermometers (RTD), thermocouples, resistance or millivolt signals in 2-, 3- or 4-wire connection and converts various input signals into a standard 4 to 20 mA analog(high selector, average value or D-value) output signal or 2-way digtal output signals with HART® -protocol after linear processing. The transmitter is programmable directly from PC or via the HART communication. Isolation also is provided between the input and output. A special signal can be set in advance while the sensor burnout or short.
Primary Technical Characteristics
Programmable Use PC or the hand operator
Measuring range Set via PC or by the hand operator
Input type Dual-input ( RTD, TC, R or Millivolt signal)
Convert accuracy ¡Ü0.1£¥FS
Cold junction accuracy ¡À1¡æ(TC)
Output 4¡«20mA/20¡«4mA Electrical isolation output
HART ¨CProtocol output (2-way)
Max-load £¨V -16V£©/0.025A£¨Current output £©
Limit current ¡Ü25mA
Response time 1s
Isolated voltage 1500VAC (input/output)
Alarm signal Programmable
Underranging linear drop to 3.8 mA
Overranging linear rise to 20.5 mA
Sensor break or short-circuit:
¡Ü3.6mA or ¡Ý21.0mA
Automatic switching while sensor damaged
Power supply 16¡«30V DC
Temperature drift 0.01£¥ FS/1¡æ
Long-term stability ¡Ü0.1¡æ per year or 0.05 £¥per year.
Oct-17-11
 
• Universal PC programmable (PCP)
• 2 wire technology, 4 to 20 mA analogue output
• High accuracy in total ambient temperature range
• Configuration during measurement using configuration kit
• Customer specific measurement range setting
• Wide measurement range, according to requirement
Field of application
• PC programmable (PCP) Temperature head transmitter for converting the input signal into a standard 4 to 20 mA analog output signal
• Input: Resistance thermometer (RTD) Pt100
• Configuration using a PC with MS180 configuration kit (MS180-PC).



Appearance and Size (in mm)

NOTE: When order, please specify the measuring range, we’ll offer programming tool if needed.
Sep-04-19

Temperature And Humidity Monitoring

$12.00K
MOQ: Not Specified
Supplier From Sharjah, Dubai, United Arab Emirates
 
We offer stand-alone Environmental monitoring appliance that provides dynamic, real-time temperature monitoring, humidity monitoring for server room, Datacentre and computer rooms or any critical environment. It has following features:

1) Real time monitoring of Humidity and Temperature.
2) Includes dry contact for alarms from critical equipment include power monitoring, water sensors, smoke and fire alarms, motion detectors, airflow, and access/entry sensors.
3) Permits remote monitoring of temperature, humidity and digital dry contact.
4) Notification of alarms via email, SMS, SNMP traps when specified temperature and humidity thresholds or the change of status of a digital dry contact signal
5) Simple integration to a Building Management System (BMS).
6) Capable of Modbus over TCP/IP. Built-in Web server.
7) Option of additional humidity & Temperature sensor.
8) Datacenter & Server room Environment monitoring & control.

We also offer Facility Monitoring system (FMS) equipment which extreme versatility that simplifies and consolidates monitoring of numerous types of signals and equipment available at facilities. These equipments can be UPS, water leak detection, Close control unit (CCU), access control or any equipment that has dry contact etc. Environmental monitoring, humidity monitoring, temperature monitoring, humidity & temperature monitoring, datacenter, server room, server room, rle, enviromux, nti, liebert, APC, netboltz, Aqualeak, SecurityProbe, openxtra, server room monitoring
Jun-14-20
 
We provide design, installation and service for Security & low-voltage technology solutions. Our focus is
to provide our clients with high quality installations, prompt support, and systems that are simple to use
and manage.
The thermal monitoring temperature kit includes a mobile cart, IP thermographic camera, camera
software, mini PC Quad core with Microsoft windows 10 professional 64bit, 6-port POE+ network
switch, 24-inch 1080p LED monitor, LTE WAN network used for remote support and notifications. iS3
shall pre-configure the system for you so your thermal temperature monitoring system is ready to go
upon arrival to your site. Only requirement from the customer is to provide 120v power and position
system at an ideal location.
Mar-30-16
 
Features:

1. Real-time monitoring of grain temperature to prevent spoilage
2. 1-wire digital temperature sensors
3. Unique temperature/level (EST120) monitoring cable
4. 98.5ft (30m) maximum cable length
5. Customizable number and location of temperature sensors
6. Simplified and lower installation costs using digital technology, wired or wireless
7. Operator interface with remote monitoring PC-software
Oct-03-06
 
Temperature test meters monitoring

Ph/ec(tds)/temperature test meters monitoring
Specifications ym-2006
Range
Ph: 0.00 -- 14.00ph ec:0.00 -- 19.99ec
C: -50pc -- 70pc pf; _58pf -- 158pf
Cf: 0.0 -- 199cf tds: 10 -- 19990ppm
Resolution:
Ph: 0.01ph pc: 0.1pc pf: 0.2pf
Ec:0.01ec cf:0.1cf tds:10ppm
Accuracy
Ph:+/- 0.10 ph pc:1.0pc
Ec=cf=tds:+/- 2% f.S
Operating temperature:0pc-- 50pc
Automatic temperature compensation:0pc--50pc
Batteries:dc6vor4x1.5v(ag13)
Dimensions:155x86x22mm
Weight:222g
Nov-01-16
Supplier From Ansan-si, South Korea (Republic Of Korea)
 
Compact size and easy to install
Precise and safe control with dual sensors in the wide range
Easy control and timer
RS485 communication (Modbus)