Temperature test meters monitoring

Ph/ec(tds)/temperature test meters monitoring
Specifications ym-2006
Range
Ph: 0.00 -- 14.00ph ec:0.00 -- 19.99ec
C: -50pc -- 70pc pf; _58pf -- 158pf
Cf: 0.0 -- 199cf tds: 10 -- 19990ppm
Resolution:
Ph: 0.01ph pc: 0.1pc pf: 0.2pf
Ec:0.01ec cf:0.1cf tds:10ppm
Accuracy
Ph:+/- 0.10 ph pc:1.0pc
Ec=cf=tds:+/- 2% f.S
Operating temperature:0pc-- 50pc
Automatic temperature compensation:0pc--50pc
Batteries:dc6vor4x1.5v(ag13)
Dimensions:155x86x22mm
Weight:222g


Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: Temperature Test Meters Monitoring

Feb-19-23
 
What exactly is a bomb calorimeter
Bomb calorimeters are used to precisely calculate the energy shift that occurs during a reaction. The original Berthelot calorimeter was developed into the contemporary Bomb calorimeter. The combined bomb calorimeter of today is constructed of corrosion-resistant steel.
An apparatus known as a bomb calorimeter is used to measure the heat of reaction at a constant volume and the measured heat, also known as the change of internal energy (E). Chemistry allows for the measurement of a reaction's heat changes at a fixed pressure or volume.
How a Bomb Calorimeter Works
The combustion heat of samples that can burn with oxygen is measured using a specific kind of constant-volume calorimeter called a bomb calorimeter. Four crucial components are
Features:
Fully automated with a coloured PLC touch-screen display
One unit; no assembly is necessary
With automatic oxygen filling, direct screen reading, standardising capability, and 400 data storing in memory
RSD +/- 1 percent and temperature resolution of 0.001 degrees Celsius.
100 pills of 1 g of or 100 calories (imported)
Used for calculating the amount of heat produced during the combustion of fuel and other organic materials. Supplied complete with a water jacket constructed of brass/steel sheet that has been duly nicked and chromium-plated, with a bakelite lid.
Heavy-duty motorised duly stirrer for consistent circulation
Pettel, Briquette Apply forcefully.
Lighting and firing apparatus
spanners, a magnifying lens with nickel-chrome wire, a vibrating and buzzing device, and a cotton reel
Steel crucible, gas-releasing valve
Oct-25-12
Supplier From Wuhan, Huifeng, China
Mar-30-22
Mar-27-15
Supplier From Changsha, Hunan, China
Apr-01-22
 
The GF302D1 three phase portable energy meter test equipment consists of an integrated three phase current source(up to 500V/120A or 500V/20A) and built-in three-phase electronic reference standard of accuracy class 0.05%. Characteristic features of the GF302D1 are its wide measuring range, high accuracy and high tolerance to unwanted external influences. The equipment offers high functionality combined with an excellent menu guided operation via built-in keyboards and colored 7" touch LCD-display. Voltage & current harmonics output from 2 to 63 times. This model portable meter test equipment can be programmable by PC, automatic generation of energy meter error test report.
Sep-04-19

Temperature And Humidity Monitoring

$12.00K
MOQ: Not Specified
Supplier From Sharjah, Dubai, United Arab Emirates
 
We offer stand-alone Environmental monitoring appliance that provides dynamic, real-time temperature monitoring, humidity monitoring for server room, Datacentre and computer rooms or any critical environment. It has following features:

1) Real time monitoring of Humidity and Temperature.
2) Includes dry contact for alarms from critical equipment include power monitoring, water sensors, smoke and fire alarms, motion detectors, airflow, and access/entry sensors.
3) Permits remote monitoring of temperature, humidity and digital dry contact.
4) Notification of alarms via email, SMS, SNMP traps when specified temperature and humidity thresholds or the change of status of a digital dry contact signal
5) Simple integration to a Building Management System (BMS).
6) Capable of Modbus over TCP/IP. Built-in Web server.
7) Option of additional humidity & Temperature sensor.
8) Datacenter & Server room Environment monitoring & control.

We also offer Facility Monitoring system (FMS) equipment which extreme versatility that simplifies and consolidates monitoring of numerous types of signals and equipment available at facilities. These equipments can be UPS, water leak detection, Close control unit (CCU), access control or any equipment that has dry contact etc. Environmental monitoring, humidity monitoring, temperature monitoring, humidity & temperature monitoring, datacenter, server room, server room, rle, enviromux, nti, liebert, APC, netboltz, Aqualeak, SecurityProbe, openxtra, server room monitoring
Jun-14-20
 
We provide design, installation and service for Security & low-voltage technology solutions. Our focus is
to provide our clients with high quality installations, prompt support, and systems that are simple to use
and manage.
The thermal monitoring temperature kit includes a mobile cart, IP thermographic camera, camera
software, mini PC Quad core with Microsoft windows 10 professional 64bit, 6-port POE+ network
switch, 24-inch 1080p LED monitor, LTE WAN network used for remote support and notifications. iS3
shall pre-configure the system for you so your thermal temperature monitoring system is ready to go
upon arrival to your site. Only requirement from the customer is to provide 120v power and position
system at an ideal location.
Mar-30-16
 
Features:

1. Real-time monitoring of grain temperature to prevent spoilage
2. 1-wire digital temperature sensors
3. Unique temperature/level (EST120) monitoring cable
4. 98.5ft (30m) maximum cable length
5. Customizable number and location of temperature sensors
6. Simplified and lower installation costs using digital technology, wired or wireless
7. Operator interface with remote monitoring PC-software
Oct-17-11
 
MS150 Series multi-channel temperature monitor is a multi-point temperature measurement instrument. It takes the highest measured temperature in measuring loops as its output signal which is sent out in the form of a 4 to 20 mA standard current signal and the temperature is displayed by the built-in LED. If required, temperature at any measuring point can be shown by operating the keys on panel. Isolation is provided between the input and output.
It is mainly used in the applications of multi-point temperature measurement or alarm warning system. By adopting SMT technology, it offers excellent accuracy, reliability and anti-disturbance.
Primary Technical Characteristics
Measuring range 0¡«100¡æ¡¢0¡«150¡æ¡¢0¡«200¡æ
£¨according to user's demand£©
Input type Pt100,Cu50£¨TC if specially required£©
Measuring Points 2,3,4,5,6 points
Convert accuracy ¡Ü0.5£¥FS
linearity error < 0.1%
Output 4¡«20mA Electrical isolation output
Digital display LED
Display accuracy 0.5%
Voltage drop for display 3V
Isolated voltage Drop 2V
Isolate Voltage 1500V AC (Input/Output¡¢with isolator)
Max-load £¨V -14V~16V£©/0.025A£¨Current output £©
Limit current ¡Ü25mA
Response time 1s
Power supply 14~30V DC
Temperature draft 0.025% FS/ 1¡æ
Long-term stability ¡Ü0.1¡æper year or 0.05£¥ per year
Ambient -40~+85¡æ£¨Aluminium alloy .Casing£©
-25 ~+75¡æ£¨Plastic Casing£©
Protection level IP66£¨Aluminium alloy£©/IP62£¨Plastic£©
Anti-RFI >10v/m(80MHz¡­¡­1000MHz).