This surge protective device( hereinafter referred to as SPD) are suitable for AC 50/60Hz, rated voltage up to 380v IT,TT,TN-C, TN-S,TN-C-S and other power supply system, it protect to indirect and direct lightning effect or other transient over voltage
SPD design according with GB18802.1/IEC61643-1 standard.
Specification details:
Model PQ1-60
Poles 4P
Max. continious working voltage(Uc) 420V AC(can customized)
Nominal discharge current(In) 30kA
Max.discharge current(In) 60kA
Voltage protection level(Up) 2.0kV
Matched circuit breaker/Fuse 32A
Response time
This surge protective device( hereinafter referred to as SPD) are suitable for AC 50/60Hz, rated voltage up to 380v IT,TT,TN-C, TN-S,TN-C-S and other power supply system, it protect to indirect and direct lightning effect or other transient over voltage
SPD design according with GB18802.1/IEC61643-1 standard.
Specification details:
Model PQ1-80
Poles 2P
Max. continious working voltage(Uc) 420V AC(can customized)
Nominal discharge current(In) 40kA
Max.discharge current(In) 80kA
Voltage protection level(Up) 2.5kV
Matched circuit breaker/Fuse 32A
Response time
Applications:
C/d class surge protective device for ac power system.
Sensitive electronic equipment
Telecom centers
Automatic control centers
Intelligent mansions
Industrial enterprises
Medical institutes
Features:
Din rail mounting for easy installation
Plug connectors for quick and easy connection or rewiring
40ka maximum surge current
Thermal disconnect device
Status indicators visually verify protection level
Surge protection device with n-pe residual current spark gap as 3+1 circuit
Specifications about m40b3+n
Parameterm40dnpe50
Iec /vde level ii/c ii/c
Nominal operating voltage 110/220v ac 500v(n-pe)
Max. Continuous operating voltage 275v 61630;/250v
Leakage current at 1ma <15ua -
Nominal discharge current at 8/20+s 20ka 20ka
Max discharge current at 8/20+s 40ka 50ka
Protection mode <1100v <1100v
Response time <25ns <100ns
Short current 61630; 200arms
Installing forward insurance device 32a gl 32a gl
Long-distance alarm
Max. Continuous operating voltage250vac/125vdc
Max. Continuous operating current imax ac (61527;/ind.)1a /1a
Max. Continuous operating current imax dc (61527;/ind.)0.2a/30ma
Mechanical specification
Dimension (mm)90 * 72 * 66
Dos shell material:pc
Obstructing burn level+according with ul94:v0
Adopting iec529/en60529ip20
Dos shell colorwhite
Test standardiec61 643-1: 1982-02, pren61 634-1 ul1449ed.2
E din vde0675part6: 1989-11/a1: 1996-03/a2: 1996-10
Environment
Operating temperature-40 ~ +85
Relative humidity_95%
Our featured products automatic transfer switch, circuit breaker, contactor, pilot light,relay, SPD, etc. with solid quality and considerable price and could equip them with enclosure.
Surge Protection Device (SPD)
It is a device used to limiting instant surge voltage and discharge surge current, it at least including a non-linear component.
SPD for Power Supply System Series Selection Guide
The installation of SPD at each lightning protection zone, according to the standard of low voltage electrical appearance, make classification of electrical equipment in accordance with the over voltage category, its insulation withstand impulse voltage level can determine the selection of SPD. According to the standard of low voltage electrical appearance, make classification of electrical equipment in accordance with the over voltage category as signal level, loading level, distribution and control level, power supply level. Its insulation withstand impulse voltage level are:1500V,2500V,4000V,6000V. As per to the protected equipment installation position different and the different lightning current of different lightning protection zone, to determine the installation position of SPD for power supply and the break-over capacity.
The installation distance between each level SPD should not more than 10m, the distance between SPD and protected equipment should as short as possible, not more than 10m. If due to limitation of installation position, can't guarantee the installation distance, then need to install decoupling component between each level SPD, make the after class SPD can be protected by the prior class SPD. In the low voltage power supply system, connecting an inductor can achieve the decoupling purpose.
SPD for power supply system specification selection principle
Max. continuous operating voltage: bigger than protected equipment, the system's max. continuous operating voltage.
TT System: Uc 1.55Uo (Uo is low voltage system to null line voltage)
TN System: Uc 1.15Uo
IT System: Uc 1.15Uo(Uo is low voltage system to line voltage)
Voltage Protection Level: less than the insulation withstand impulse voltage of protected equipment
Rated discharge current: determined as per to the lightning situation of the position installed and lightning protection zone.
SP1 Series
Normal Working Conditions
-Altitude not exceed 2000m
-Ambient air temperature:
Normal range: -5 ºC~+40 ºC
Extend range: -40 ºC~+80 ºC
-Relative Humidity: 30% - 90% under indoor temperature condition
- At the place without obviously shaking and shock vibration
- Non-explosion danger medium, non-corrosion gas and dust ( including conductive dust)
Classification
-As per Nominal Discharge Current:
5,10,20,30,40,60KA(8/20 µs)
- As per Maximu
Fnad Electrical Appliance Plant, established is located in Ningbo, China. It is 2km away from Geely Automobile Industrial Park. It is a science and technology enterprise integrating with R&D, manufacture, trade and service. The Plant has focused on motor protection for more than years. It is specialized in applications of single-chip microcomputer technology in the fields of industrial control, power electronics and automobile electronics.
Our main products include motor protectors, phase failure protectors, phase sequence protectors, volt-ammeters, surge protector, temperature controllers, etc. we have an in-depth study in prevention of occurrence of phase failure, phase sequence, overload, under-load, overvoltage, under-voltage, three-phase imbalance, over-current and similar abnormalities in customersâ?? equipments and provide such solutions as prevention, alarming and equipment protection. It supports major elevator plants, thermal power plants, automobile plants, crane factories, textile mills, refrigerating plants and chemical plants and provides solutions for them. Some products have passed CE certification and ROSH environmental certification of European Union.
We endeavor to make the company to be listed in Hong Kong in 2020. Welcome to visit and communicate with us.