Please click here to check who's online and chat with them.

Gf1021 Single Phase Energy Meter Test System

Supplier From China
May-17-22

GF1021 single phase portable energy meter test system used to test single phase energy meter error. Adopt mature signal synthetic and power amplifier technology, high precision voltage source and current source output. Widely used in lab and field, and then as single phase standard source. The portable meter test equipment offers high functionality combined with an excellent menu guided operation via coloured 7' touch screen or externally via interface.

Price and Minimum Quantity

Price: $12655
MOQ: Not Specified

Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: Gf1021 Single Phase Energy Meter Test System

Feb-20-23
 
GF1021 single phase portable energy meter test system used to test single phase energy meter error. Adopt mature signal synthetic and power amplifier technology, high precision voltage source and current source output. Widely used in lab and field, and then as single phase standard source. The portable meter test equipment offers high functionality combined with an excellent menu guided operation via coloured 7 touch screen or externally via interface.
Jun-04-21
 
Introduction
GF1021 portable single phase energy meter test system used to test single phase energy meter. Adopt mature signal synthetic and power amplifier technology, high precision voltage source and current source output. Widely used in lab and field, and then as single phase standard source.
TECHINICAL SPECIFICAITON
Accuracy class 0.05%, 0.1%
Power supply One Phase AC 85-265V, frequency 50/60Hz.
AC Voltage output
Range 57.7V, 100V, 220V, 380V; max 500V
Adjustment range (0-120)%RG(1)
Adjustment fineness 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability 0.01%/120s
Distortion 0.1% (Non-capacitive load)
Output load max 30VA
Measuring accuracy 0.05%RG
AC Current output
Range 200mA, 1A, 5A, 20A, 100A; max 120A
Adjustment range (0-120)%RG
Adjustment fineness 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability
May-23-14
 
Snt 1100 single phase meter test bench is widely used in power utilities,¡émeter manufacturer,¡émeasurement/quality test lab and other enterprises to test single phase energy meter.
Jul-14-11
 
Overview:
The RT6103-S Single Phase Energy Meter Test Instrument (Split Type) adopts internationally advanced new-generation digital power source technologt, integrates all the technological advantages of both domestic and foreign watt-hour meter calibration software, and is introduced to global market by Rowwin Test in a powerful and sensational way. The single phase energy meter test instrument comprises of PWM power source, standard digital energy meter,error processor and PC processing software, this energy meter test instrument can test 3 to 60 various watt-hour meters of Grade 0.5 or lower simultaneously, also is an ideal new-generation multi-position energy meter testing instrument.

Technical Parameters:
1. Accuracy class: 0.1/0.05.
2. Reference standard energy meter£ºSingle phase wide-measurement range standard energy meter.(Accuracy class:0.1/0.05). Multi-path voltage transformer: Accuracy class:0.01; Rated load per path:10VA.
3. Voltage range:220v(240V option),Output range:0~125%,Resolution:0.01%full range.
4. Current measurement range:0.1~100A(200A option),Output range:0~120%,Resolution:0.0001A(minimum)
5. Phase angle:0~360¡ã,Resolution of phase angle setting:0.01¡ã.
6. Frequency:45Hz~65Hz,Resolution:0.01Hz.
7. Output waveform distortion:Both voltage and current<0.5%.
8. Output voltage,current and power stability:<0.05%.
9. Output capacity:Current:1,000VA(120A);Voltage:400VA(24 meter testing positions). If necessary,the maximum load can be extended to Current:1,800VA and Voltage:1,000VA.
10. Load characteristics:Resistive,inductive and capacitive(less than 4uF).
11. Starting current output:5mA(minimum);Accuracy:5%;Starting power:Accuracy 5%.
12. Energy meter testing positions:24/48 standard (3 ~60 meter positions also available).
13. Testing functions:Accuracy testing,Creep testing(no load testing),Starting up testing,Harmonic testing,Repeatability testing, Influencing testing,Dial testing and etc.
14. Input power supply:220VAC,¡À10%,50Hz;Max.power consumption:1,500VA(24 meter testing positions).


Dimension:
24 meter testing positions(1 rack): 2200*700*1920mm.
48 meter testing positions(2 racks): 2200*700*1920mm each.
Cabinet: 600*800*1600mm.
May-23-14
 
Measure normal parameter of power line:

Vrms, irms, frequency

Active power, reactive power, apparent power

Phase angle between voltage and current

Power factor

Calibrate single phase meter;

Measure harmonic of voltage and current;

Measure waveform of voltage and current;

Measure current transformer¡¡¥s ratio (option);

Energy accumulation test;

Built-in clock, record testing time exactly;

Store, check and transmit the measured data;

Connected to pc, reading recorded data and real-time measured data by pc;

Alarm when the tested voltage and current over the testing range;

Connected to portable printer (option).
Feb-20-23
 
GF102 series portable single phase energy meter test bench used to test 1pc or 3pcs single phase energy meter or AC meter at same time. Adopt mature signal synthetic and power amplifier technology, high precision voltage source and current source output from 120A/600V. Widely used in lab and field, and then as single phase standard source. It is suite for electricity meter manufacturing enterprises, scientific research institutes, metrological service institutions, electric power companies etc.
Nov-28-19

Single Phase Energy Meters

$0
MOQ: Not Specified
 
May-23-14
 
1.Starting test and creeping test

2.Measuring the different constant meters synchronously.

3.With the protect function of overload, short voltage circuit and open current circuit.

4.The testing software with friendly windows 2000 and xp interface, include functional module of all kinds of modern energy meter needed, to reality error test, harmonic test, demand test, influence test.

5.The stored testing data can be transferred to multi-format for other program using
Jul-14-11
 
Overview:

The RT6303-S Three Phase Energy Meter Test Instrument(Split Type) adopts internationally advanced new-generation digital power source technologt,integrates all the technological advantages of both domestic and foreign watt-hour meter calibration software, and is introduced to global market by Rowwin Test in a powerful and sensational way.The Three phase energy meter test instrument¡¯s power source uses MCU single chip microprocessor as its core technology and adopts various techniques as digital synthesis,digital frequency modulation,digital amplitude modulation,digital phase-shifting,pulse width modulation and so on to bring you such important features as high reliability and good load characteristics.Its more humane and intelligent meter calibration software makes it possible for an ordinary,heavy and boring calibration to be carried out more easily and efficiently.

Technical Parameters:
1. Accuracy class: 0.1/0.05
2. Reference standard energy meter: Three phase wide-measurement range standard energy meter,Accuracy class:0.1/0.05
3. Output voltage: 3* 57.7/100/220/380V Y/¡÷,0~120%Adjustment fineness:0.01% full range,adjustable phase by phase
4. Output current: 3* 0.1~100A(200A also available),0~120%Adjustment fineness:0.0001A(minimum),adjustable phase by phase
5. Phase shift:0~360¡ãAdjustment fineness:0.01¡ã,adjustable phase by phase
6. Frequency:45Hz~65Hz,Adjustment fineness:0.01Hz
7. Output waveform distortion:Both voltage and current<0.5%
8. Output voltage,current and power stability:<0.05%(180s)
9. Output capacity(per phase): Current:650VA(120A); Voltage:300VA(16 meter testing positions). If necessary,the maximum load can be extended to Current:1,200VA and Voltage:800VA
10. Load characteristics:Resistive,inductive and capacitive(less than 4uF)
11. Harmonic wave output:2-21st sub-harmonic wave,content<40%; 3rd,5th and 7th sub-harmonic waves are superposed,content<10% each;Control of wave group(sub-harmonic wave)
12. Energy meter testing positions:16/32(standard);3~40 meter testing positions also available
13. Testing functions:Accuracy testing,Creep testing(no load testing),Starting up testing,Harmonic testing,Repeatability testing, Influencing testing,Dial testing and etc.
14. Power supply: AC 3*220/380V¡À10%,50Hz(customer define);Max. power consumption:2000VA(16 meter test positions).

Dimension:
16 meter testing positions(1 rack): 2200*700*1920mm
32 meter testing positions(2 racks): 2200*700*1920mm each
Cabinet: 600*800*1920mm.

Verification Status