1.Starting test and creeping test 2.Measuring the different constant meters synchronously. 3.With the protect function of overload, short voltage circuit and open current circuit. 4.The testing software with friendly windows 2000 and xp interface, include functional module of all kinds of modern energy meter needed, to reality error test, harmonic test, demand test, influence test. 5.The stored testing data can be transferred to multi-format for other program using
Snt 1100 single phase meter test bench is widely used in power utilities,¡émeter manufacturer,¡émeasurement/quality test lab and other enterprises to test single phase energy meter.
Measure normal parameter of power line: Vrms, irms, frequency Active power, reactive power, apparent power Phase angle between voltage and current Power factor Calibrate single phase meter; Measure harmonic of voltage and current; Measure waveform of voltage and current; Measure current transformer¡¡¥s ratio (option); Energy accumulation test; Built-in clock, record testing time exactly; Store, check and transmit the measured data; Connected to pc, reading recorded data and real-time measured data by pc; Alarm when the tested voltage and current over the testing range; Connected to portable printer (option).
Features: 1. Check the error of active and reactive of watt-hour meter at the same time, and meanwhile check the error of main and secondary meter in the same circuit. 2. Display the electrical constants such as: voltage, current, power, power factor, phase and frequency and etc. 3. Measure ct ratio, wave form display. 4. Measure 2-51 voltage and current harmonics. 5. Judge wrong wiring. 6. Measure the baud rate for multi-function energy meter and meter number reading. ¦ct secondary loading function. 8. Automatically correct the clamp error.
Ac current output (0~10/20a) Adjust fineness: 0.01%rg Accuracy: better than ¡¨¤0.05%rg Stability: better than ¡¨¤0.01%rg/1min Distortion degree: better than 0.1% (not capacitive load) Output power: 25va Full load adjust rate: less than ¡¨¤0.01%rg Full load adjust time: less than 1ms Stability time: ¡¨¤60ppm/ year Power output: Accuracy: better than 0.05%rg Stability degree: better than 0.01%/1min Phase position: Adjust range: 0¡«359.99 degree Differentiation: 0.01 degree Accuracy: ¡¨¤0.03 degree Frequency: Adjust range: 40hz¡«65hz Differentiation: 0.002hz Accuracy: ¡¨¤0.002hz Temperature float: ¡¨¤0.5ppm/¡æ Stability time: ¡¨¤4ppm/year Power factor: Adjust range: -1¡«0¡«+1 Differentiation: 0.0001 Accuracy: 0.0005 Harmonic output: The instrument can accurately output 2¡«22 harmonics. Dimension& weight: Dimension¡êo450mm¡¨¢380mm¡¨¢160mm¡ê¡§l¡¨¢w¡¨¢h¡ê© Weight¡êo¡¨¹18kg¡¡ê Environment condition: Working temperature¡êo0¡æ¡«40¡æ Relative humidity: ¡¨¹85% Storage condition: ¡ê-30¡æ¡«60¡æ
Frequency 50hz ¡¨¤2hz Outside magnetic field intensity: ¡¨¹0.025mt Warm-up: the time of warm-up: ¡y30 minutes Using condition: Environment temperature: 5¡æ¡-40¡æ Relative humidity 25%¡«85% Test current: 0.05a¡«120a Current range 1a, 10a, 100a Imax=120a Test voltage 50v¡-480v Voltage range: 50v, 100v, 200v, 400v Umax=480v Accuracy: Current: ¡¨¤0.05%rg 0.125¡«120a Voltage: ¡¨¤0.05%rg 40v¡«480v Power: Active power ¡¨¤0.05% (50v¡«480v, 0.2a¡«120a, cosØ¡y0.5) Reactive power ¡¨¤0.1% (50v¡«480v, 0.2a¡«120a) Apparent power ¡¨¤0.1% (50v¡«480v, 0.2a¡«120a) Power factor Measurement range: 0¡«¡¨¤1 Accuracy: ¡¨¤0.05%rg (cosØ¡y0.5) Phase: Measurement range: 0¡ã¡«360¡ã Accuracy: 0.05¡ã(50hz) Frequency: 0.03%rd (45hz¡«65hz) Pulse output: Ttl level Load ¡ê¾2kw High frequency output port: fh Low frequency output port: fl Affection of temperature: (5¡æ¡«40¡æ) Voltage, current and frequency: ¡¨¹¡¨¤15ppm/¡æ Power: ¡¨¹¡¨¤30ppm/¡æ Communication port: Rs232 Rs485 Power supply: Voltage: ac220v¡¨¤22v Frequency: 50hz¡¨¤2hz Power: 40va Dimension: 432mm¡¨¢131mm¡¨¢308mm Weight: 15kg