PARAMETERS
Electrical parameters
Power voltage AC220V±10% or AC110V±10%, 50/60Hz±10%
Time measurement 0.1ms-999999.999s
AC current output
Phase current output (effective value) 3 x 0-30A
Maximum power output 260VA/phase
Maximum parallel current output (effective value) 0-90A
Long-term allowable working value of phase current
(effective value) >10A
Allowable working time of maximum current >11s
Accuracy class
The three-phase microcomputer relay control tester has a 4-phase voltage 3 phase current output, which is suitable for various types of relay protection devices. The microcomputer relay control tester uses a high-speed high-performance digital signal processor comparative speed, transmission frequency bandwidth, and software application bifurcation algorithm produces each of the respective high-precision waveforms. Due to the integrated structure, each part is closely coupled, the data transmission distance is short, and the structure is compact.
Technical parameter:
AC current output
Output accuracy Level 0.5
Phase current output (effective value) 0 40A
Three merge current output (effective value) 0 120A
Phase electric length time allows work value (effective value) 10A
Phase current maximum output power 420VA
Maximum output power at the maximum output of three 1000VA
Working time is allowed when the maximum output of the three mesh is output 10s
Frequency range (foundation) 20 1000Hz
Harmonic number 1 20 times
DC current output
Output accuracy Level 0.5
Current output 0 10A / each phase, 0 20A / two superimposed
Maximum output load voltage 20V
AC voltage output
Output accuracy Level 0.5
Phase voltage output (effective value) 0120V
Line voltage output (effective value) 0210V
Maximum voltage output value 0240V
Phase voltage / line voltage output power 80VA /100VA
Frequency range (fundamental) 201000Hz
Harmonics 1 20 times
Supplier: Industrial electrical wires and cables, ups systems and ancillary, junction boxes, mccb, relays and various other electrical products and equipment. Buyer: Industrial electrical parts
Type Car charge
Charging Port 2 Ports
Connection USB Port
Warranty 12 months
Combination MP3/MP4 Player
Voltage 12-24v
DS2018
Design Style New China-Chic
Product name 12V/24V Waterproof 2.4A Dual USB Charger Socket Power Outlet
Material ABS+PC Fireproof Material
Car USB Input Voltage 12v/24V
Car Chargers Power Output: 5V 4.8A DC 5V/4.8A (2.4A for each)
LED color Blue,Green,Red
Usage Fits for Car,Boat,Marine,ATV,RV,Motorcycle and other 12-24V Vehicles
Overcharge Protection Over-heated, over-current, over-charging protection
OEM YES
Color Black
Easy to install Can be installed vertically
Packaging and delivery
Packaging Details 1pcs in one polybag,100pcs in one bigger ploybag,500pcs in one normal Carton
Function QC2.0
Maximum Output Power 18W
Place of Origin Guangdong, China
Usage Mobile Phone
Material ABS
Protection Overcurrent
Private Mold NO
Model Number DS2018
Input voltage and current 12v/4a
output voltage and current 5V/4.5A
Item 4.8A Dual USB Port Socket Charger Rocker Style,
color BLUE,, RED
Certificate CE FCC ROHS
voltage 12-24V
Material ABS+Nylon
Application car ,boat
samples free for 1 pc
market range usa, australia, japan, eupora
* Waterproof Dual USB Port Charger Socket Outlet - This 12v usb outlet is built-in dual USB charging ports, two ports output: 5V/2.1A&1A (total 3.1A), that's enough to charge two devices simultaneously! IP65 waterproof grade allows the charger socket power outlet to do a good job under bad weather.
* LED Indicator Light - With red LED indicator, when you charge your devices on your car or boat, the bright light on the 12v dual outlet socket will help you to find it easily in the dark.
* Overcharge Protection - Over-heated, over-current, over-charging protection; This dual usb charger power socket will stop charge automatically when your device is fully charged.
* Wide Compatibility - Universal usb charger socket power outlet fit for most 12-24V Car Motorcycle ATV UTV RV Vehicles Marine Boat. Charge for Samsung Galaxy Note 8/5/4/3/2, for Samsung Galaxy S9/S9 Plus/S8/S8 Plus/S7/S7 Edg, for Samsung Galaxy S3/S4/S5/S6 Active/ON5, for iPhone X/8/8 Plus7/7 Plus/6/6 Plus/6S/6S Plus/, for LG G7/G6/G5/G4/G3/G2/V10/V20/V30/G Stylo LS770, for Google Nexus 6/5/4/5X/6P and more.
* Package Included- 1 x USB Power Outlet Socket; 2 x Terminals; Easy to contact customer service.
2.Measuring the different constant meters synchronously.
3.With the protect function of overload, short voltage circuit and open current circuit.
4.The testing software with friendly windows 2000 and xp interface, include functional module of all kinds of modern energy meter needed, to reality error test, harmonic test, demand test, influence test.
5.The stored testing data can be transferred to multi-format for other program using
The RT6303-S Three Phase Energy Meter Test Instrument(Split Type) adopts internationally advanced new-generation digital power source technologt,integrates all the technological advantages of both domestic and foreign watt-hour meter calibration software, and is introduced to global market by Rowwin Test in a powerful and sensational way.The Three phase energy meter test instrument¡¯s power source uses MCU single chip microprocessor as its core technology and adopts various techniques as digital synthesis,digital frequency modulation,digital amplitude modulation,digital phase-shifting,pulse width modulation and so on to bring you such important features as high reliability and good load characteristics.Its more humane and intelligent meter calibration software makes it possible for an ordinary,heavy and boring calibration to be carried out more easily and efficiently.
Technical Parameters:
1. Accuracy class: 0.1/0.05
2. Reference standard energy meter: Three phase wide-measurement range standard energy meter,Accuracy class:0.1/0.05
3. Output voltage: 3* 57.7/100/220/380V Y/¡÷,0~120%Adjustment fineness:0.01% full range,adjustable phase by phase
4. Output current: 3* 0.1~100A(200A also available),0~120%Adjustment fineness:0.0001A(minimum),adjustable phase by phase
5. Phase shift:0~360¡ãAdjustment fineness:0.01¡ã,adjustable phase by phase
6. Frequency:45Hz~65Hz,Adjustment fineness:0.01Hz
7. Output waveform distortion:Both voltage and current<0.5%
8. Output voltage,current and power stability:<0.05%(180s)
9. Output capacity(per phase): Current:650VA(120A); Voltage:300VA(16 meter testing positions). If necessary,the maximum load can be extended to Current:1,200VA and Voltage:800VA
10. Load characteristics:Resistive,inductive and capacitive(less than 4uF)
11. Harmonic wave output:2-21st sub-harmonic wave,content<40%; 3rd,5th and 7th sub-harmonic waves are superposed,content<10% each;Control of wave group(sub-harmonic wave)
12. Energy meter testing positions:16/32(standard);3~40 meter testing positions also available
13. Testing functions:Accuracy testing,Creep testing(no load testing),Starting up testing,Harmonic testing,Repeatability testing, Influencing testing,Dial testing and etc.
14. Power supply: AC 3*220/380V¡À10%,50Hz(customer define);Max. power consumption:2000VA(16 meter test positions).
Dimension:
16 meter testing positions(1 rack): 2200*700*1920mm
32 meter testing positions(2 racks): 2200*700*1920mm each
Cabinet: 600*800*1920mm.
The RT6303B Multi-function Three Phase Energy Meter Test Instrument adopts internationally advanced new-generation digital power source technology, integrates all the technological advantages of both domestic and foreign watt-hour meter calibration software, and is introduced to global market by Rowwin Test in a powerful and sensational way. The Multi-function three phase energy meter test instrument¡¯s power source uses MCU single chip microprocessor as its core technology and adopts various techniques as digital synthesis, digital frequency modulation, digital amplitude modulation, digital phase-shifting, pulse width modulation and so on to bring you such important features as high reliability and good load characteristics. Its more humane and intelligent meter calibration software makes it possible for an ordinary, heavy and boring calibration to be carried out more easily and efficiently.
Technical Parameters:
1. Accuracy class: 0.1/0.05
2. Reference standard energy meter: Three phase wide-measurement range standard energy meter, Accuracy class:0.1/0.05
3. Output voltage: 3* 57.7/100/220/380V Y/¡÷,0~120%Adjustment fineness:0.01% full range, adjustable phase by phase
4. Output current: 3* 0.1~100A(200A also available),0~120%Adjustment fineness:0.0001A(minimum),adjustable phase by phase
5. Phase shift:0~360¡ãAdjustment fineness:0.01¡ã,adjustable phase by phase
6. Frequency:45Hz~65Hz,Adjustment fineness:0.01Hz
7. Output waveform distortion: Both voltage and current<0.5%
8. Output voltage, current and power stability:<0.05%(180s)
9. Output capacity(per phase): Current:650VA(120A); Voltage:300VA(16 meter testing positions)If necessary, the maximum load can be extended to Current:1,500VA and Voltage:800VA
10. Load characteristics: Resistive, inductive and capacitive(less than 4uF)
11. Harmonic wave output:2-21st sub-harmonic wave, content<40%;3rd,5th and 7th sub-harmonic waves are superposed, content<10% each;Control of conduction angle(odd sub-harmonic wave);Control of wave group(sub-harmonic wave)
12. Starting up current: Minimum 0.3 mA, Accuracy:5%,Starting power: Accuracy:5%
13. Tests: Demand test; Frequency impact test; Voltage impact test; Second pulse clock precision test; GPS clock synchronization; Constant calibration; Combined error test; Various register checking;RS485 communication interface test
14. Energy meter testing positions:16/32(standard);3 to 40 meter testing positions also available
15. Testing functions: Accuracy testing, Creep testing(no load testing),Starting up testing, Harmonic testing, Repeatability testing, Influencing testing, Dial testing and etc
16. Power supply: AC 3*220/380V¡À10%,50Hz(customer define);Max. power consumption:2000VA(16 meter test positions).
Dimension:
16 Meter testing positions(1 rack): 2200*700*1920mm
32 Meter testing positions(2racks): 2200*700*1920mm
Cabinet: 600*800*1920mm.