Quick Sense Digital AC 90V 250V Digital Temperature Controller Thermostat
Switch the modes between cool and heat; Control temperature by setting the temperature set value and the different value; Temperature collaboration; Refrigerating control output delay protection; Alarm when the temperature exceeded temperature limit or when sensor error.
Specification and size
Front panel size: 75(L)x34.5(W)(mm)
product size: 75(L)x34.5(W)x85(D)(mm)
Mounting size: 71(L)x29(W)(mm)
Sensor length: 2m(Include the probe)
Technical parameters
Temperature measuring range: -50C~90C
Resolution: 0.1C
Accuracy: +-1 C(-50C~70C)
Power supply: 220VAC 50Hz/60Hz
Power consumption:
Cd-x08 series 3 digital temperature controller
Feature
1. New algorithm using fuzzy logical pid control
2. Six alarm mode setting freely
3. Tc input, rtd input, voltage input, ampere input
4. Relay output, voltage output, ampere output
5. 3 digit led display
Model and parameter
1.How to select input type
Rtd Pt100(0-499.9ípc) No need custom-mode; free exchange the input way
Tc K(0-600ípc)
R(0-1600ípc), s(0-1600ípc)ú¼bú¿0-1800ípcú¬ú¼eú¿0-1000ípcú¬ú¼nú¿0-1200ípcú¬ú¼jú¿0-800ípcú¬ú¼tú¿0-400ípcú¬ Need custom-mode
2.Technical parameters
Measuring accuracy Less ía0.5%f.Síal dig
Control mode On/off control, pid direct action, pid reverse action
Control accuracy ía1ípc
Control output Relay output, voltage output
0-10madc output, 4-20madc output
Relay contact burden 3a/250vac
Power 90-250vac 60hz
Anti-interference Iec 3g
Model no.: sf-103
Digital temperature controller
For fan cooling cake display showcases of medium& high temperatures
Waterproof panel
Temperature control / light control
Automatically=manually defrost by turning off the unit
Manually defogging control
Re-start delay
Renew factory defaults by button operation
Rangeí4545¦
Accuracy: +1¦
Sensor: ntc, 2pcs(room temperature & defrosting control)
Power supply: 230vac or 120vac 50/60hz
Compressor:20a/ 250vac (1hp)
Defogging heater:10a/250vac
Light: 5a/250vac
Dimension: 77(l)-35(w)-60(d)mm
Mounting hole dimension:71(l)-29(w)
Model no.: sf-104a
Feature: same as sf-104s (besides built-in relays and transformer)
Digital temperature controller
For fan cooling freezers & cold rooms of low temperature
Waterproof panel
Manually=automatically defrost by electric heater
Evap. Fan control
Time/temp.Setting to end defrosting
Re-start delay
Parameter locking
Celsiuc / fahrenheit degree selection
Buiit-in transformer and relays
Range:4545¦(40120h)
Accuracy: +1¦(+2h)
Sensor:ntc, 2pcs (room temperature & defrosting control)
Power supply: 230vac or 120vac 50/ 60 hz
Compressor:16a/1hp
Defrosting:10a/250vac
Evap.Fan:8a/250vac
Dimension: 77(l)-35(w)-60(d)mm
Mounting hole dimension:71(l)-29(w)mm
Digital temperature controller
For fan cooling freezers& cold rooms of low temperature
Waterproof panels
Double displays (with an outer small display shows temperature synchronously)
Manuallyf=automatically defrost by electric heater
Evaporator fan control
Time/temp.setting to end defrosting
Parameter locking
Renew factory defaults by button operation
Range:·í45f+45f¦(·í40f+120+H)
Accuracy: f+1f¦(2+H)
Sensor: NTC, 2pcs (room temperature &defrosting control)
Power supply: 230VAC or 120VAC 50 / 60Hz
Compressor:20A/ 250VAC (1HP)
Heater:10A/250VAC
Evap.fan:5A / 250VAC
Host controller dimension: 77(L)f-35(W)f-60(D)mm
Mounting hole dimension of host panel:71(L)f-29(W)mm
Accessional display dimension: 83(L)f-23(W)f-18(D)mm
Mounting hole dimension of accessional display:66(L)f-19.5(W)mm
BRAND : FUJI TEMPERATURE CONTROLLER
PXF9 , PXF4, PXF5, PXF4 SOCKET TYPE ALL SERIES AVAILABLE .
Precise control:
Achieved a processing speed of 50 ms which is 10 times faster than conventional models. Reading accuracy is also improved from �±0.5% to �±0.2%*.
*Comparison under 0â??850�°C range, with RTD. See the Data Sheet for details.
Easy-to-see display
MVA LCD* which offers high contrast and wide viewing angle
Process value is displayed in white
*Minimal translucent type vertical alignment liquid crystal display
Practical options
Simple watt-hour metering function: allows you to monitor energy consumption
Operating days alarm: tells you the appropriate time for maintenance work
Most compact class in industry
36% smaller (than conventional models) and 58-mm depth shallow body helps downsize your facility
Universal input
You can use any input among RTD, thermocouples, voltage, current, and mV. The set-up for input change is very easy, only requires parameter change. This allows reduction of maintenance parts
BRAND: WEST PID TEMPERATURE CONTROLLER
WEST Controller:
Model: WEST-6100+,P6100
Model: WEST-4100+,P4100
Model: WEST-8100+,P8100
Features and Benefits:
Dual setpoints & optional remote selection
Plug-in output modules allow installing just the functions needed in
Expanded user-selectable operator modes in
User-selectable plug-and-play output cards in
Process and loop alarms in
Adjustable hysteresis in
Optional 10V SSR driver in
Improved Windows PC configuration software
Improved easy-to-use HMI
Jumperless input configuration
Auto-hardware recognition
Faster communication speeds
More security options
Backward compatible panel cutout, housing and terminal wiring capability
P6100/P6170/P8100/P4100