Please click here to check who's online and chat with them.
Supplier From Israel
Feb-23-09
Supplier : Electronic safes

Verification Status



Contact Details:
-
Yavne 68011
Israel


Recent User Reviews

This user has not received any reviews yet!
 
 
Contact Supplier
Renew

More Items Similiar to: Jsh

Feb-06-25
Supplier From Beijing, , China
Aug-14-07
Supplier From Rizhao, Shandong, China
Dec-16-08
Supplier From Chennai, Tamilnadu, India
Dec-26-17
 
Conventional fire alarm smoke detector smoke probe sensor

This device is photoeletronic detector uses a state-of-the-art optical sensing chamber.

This smoke detector is compatible with all conventional fire alarm control panel

Dual leds, two leds blink standby, provide 360dgree visibility

With unique optical sensing chamber, engineered to sense smoke by a wide range of combustion sources.

Unpolarized wire input to prevent the likelihood of wiring errors
Specifications

Operating voltage range: 9 to 28vdc volts non-polarized

Standby current: 60µa @ 24 vdc

Maximum alarm current (led on: ) 30ma @ 24 vdc

Operating humidity range: 10% to 93% relative humidity, non-condensing

Operating temperature range: 14°f to 122°f (-10°c to50°c)

Adjustable sensitivity: 0.15ï½?0.3db/m

Height: 2.2ë� (55 mm) installed in base

Diameter: 4.0ë� (103 mm)

Weight: 5.5 oz. (155 g)
Dec-26-17
 
2zone MINI Conventional Fire Alarm Control Panel Fire Alarm Host/Master Panel /Slave Panel

Product Features

1. 2 conventional input zones.
2. 1 notification appliance circuits (NAC) with built-in synchronization forANSI 3.41and Gentex.

3. The panel comes with a 2 amp power supply.
4.Dedicated alarm and trouble relays.
5.1 RS485 can be able to connect the other panel.
6. Housed in a 205mm W x 258mm H x 81mm D metal enclosure.
7. Enclosure supports two 12V, 4Ah backup batteries.
8.The panel can be used independently or connect by RS 485.
Specifications

Primary AC 120VAC 50/60 Hz Power supply rating
240VAC 50/60 Hz
Power supply rating 2 Amps @ 24VDC
Maximum Battery Charging Current 0.98 Amps @ 26VDC
Initiating Device Circuits 2 Zones Alarm Zone 2
Normal Initiating Operating Voltage 23VDC, Maximum 26VDC, regulated
Normal Quiescent Current (normal status)
Dec-26-17
 
Dry contact Ex Double infrared flame detector relay output EXdIICT6

Dry contact Explosion proof Double infrared flame detector Fire alarm relay output Fault relay output IR2 EXdIICT6

Product function and composition

A705/IR2 can be applied to the need to monitor the implementation of the fire place, quickly found that the fire may cause the burning flame, issued in a timely manner

Fire alarm.

A705/IR2 is converted to electrical si gnal by two infrared pyroelectric sensors which work in different bands.

Signal input industrial computing chip for comparison, operation and processing, with the detecter&anysafe II Ir dedicated intelligent control software, you can Send out a fire alarm in time.

A705/IR2 uses the aluminum die-casting flameproof shell, has good protective properties and explosion-proof, corrosion resistance, aging resistance, can work for a long time

In the indoor, outdoor and all kinds of special industrial places.

Sensor sharp probe AE-S708/4 and AE-S708/5 infrared pyroelectric sensor

Optical window ï¼?white gems (Al2O3)

housing

L material: aluminum alloy

L molding process: Die Casting

L coating process: surface electrostatic powder coating, internal metal passivation treatment.

The weight is less than 1kg

Explosion proof and protection l anti explosion: EXd II CT6

L protection: IP66
Dec-26-17
 
2-wire Conventional Heat Detector Heat Alarm Sensor

The device is intelligent sensors that utilize a state-of-the-art thermistor sensing circuit for fast response.

Features and Benefits

1.Compatible with all the conventional fire alarm
control panel

2.Unpolarized wire input

3. Wide range of operating voltages

4. High precision electronic thermistor

5. Built in microprocessor intelligent software

6. wo LEDs blink standby , provide 360° visibility

7. Insect-resistant s creening

8. Twist-on mounting base with tamper lock

9. Remote Indicator LED can be connected.
Specifications

Installation Temperatures: 14°F to 122°F (-10°C to50°C)

Operating Humidity Range: 10% to 93% Relative Humidity Non-condensing

Operating Voltage Range: 16 to 32VDC Volts Non-polarized

Standby Current: 40µA @ 24 VDC

Maximum Alarm Current (LED on: ) â?¤30mA @ 24 VDC

Fixed Temperature Rating: 135°F (57°C)

Height: 2.2� (55 mm) installed in Base

Diameter: 4.0� (103 mm)

Weight: 5.5 oz. (155 g)
Dec-26-17
 
2-wire DC powered Conventional Manual Call Point Push Button

The conventional manual call point designed for conventional fire alarm system for reporting fire or emergency
condition by its button latches. The call point has one 300 ohm resistor is used on the PCB board between
Zone+ and Zone- or one relay contact (NO, COM, NC ) output when the button is pressed.
Specifications:

Operating Voltage Range: 9ï½?32VDC Volts
Nominal Operating Resistance: 300Ω
Relay Contact Ratings: 2A/30VDC
Operating Humidity Range: 95% RH, Non-condensing
Operating Temperature Range: -10C to 50C (14F to 122F)
Dimensions: W89mm ,H93mm, D26mm
Base Dimensions: W87mm ,H87mm, D31.5mm
Weight: Net Weight 125g (with base)
Colour/Case Material: Red/ ABS
Dec-26-17
 
2-wire DC24V Conventional Manual Call Point Broken Glass Button Push Button

The conventional manual call point designed for
conventional fire alarm system for reporting fire or
emergency condition by pull down the plate. The
manual call point can be reset by a special key
without breaking the glass.

Features

1. Compatible with all the conventional fire alarm control panel
2. Can be reset by key without use a new glass
3. 470 Ohm resistance
4. Easy surface mounting Base included
Specifications

Operating Voltage Range: 9 to 28VDC Volts
Alarm Resistance 470ohm/1W
Operating Humidity Range: 10% to 93% Relative Humidity, Non-condensing
Operating Temperature Range: -10C to 50C (14F to 122F)
Dimensions: Length 140mm, Width 105mm, Depth 45mm
Weight: Net Weight 220g

Verification Status