3. The panel comes with a 2 amp power supply.
4.Dedicated alarm and trouble relays.
5.1 RS485 can be able to connect the other panel.
6. Housed in a 205mm W x 258mm H x 81mm D metal enclosure.
7. Enclosure supports two 12V, 4Ah backup batteries.
8.The panel can be used independently or connect by RS 485.
Specifications
Primary AC 120VAC 50/60 Hz Power supply rating
240VAC 50/60 Hz
Power supply rating 2 Amps @ 24VDC
Maximum Battery Charging Current 0.98 Amps @ 26VDC
Initiating Device Circuits 2 Zones Alarm Zone 2
Normal Initiating Operating Voltage 23VDC, Maximum 26VDC, regulated
Normal Quiescent Current (normal status)
A705/IR2 can be applied to the need to monitor the implementation of the fire place, quickly found that the fire may cause the burning flame, issued in a timely manner
Fire alarm.
A705/IR2 is converted to electrical si gnal by two infrared pyroelectric sensors which work in different bands.
Signal input industrial computing chip for comparison, operation and processing, with the detecter&anysafe II Ir dedicated intelligent control software, you can Send out a fire alarm in time.
A705/IR2 uses the aluminum die-casting flameproof shell, has good protective properties and explosion-proof, corrosion resistance, aging resistance, can work for a long time
In the indoor, outdoor and all kinds of special industrial places.
Sensor sharp probe AE-S708/4 and AE-S708/5 infrared pyroelectric sensor
Optical window ï¼?white gems (Al2O3)
housing
L material: aluminum alloy
L molding process: Die Casting
L coating process: surface electrostatic powder coating, internal metal passivation treatment.
The weight is less than 1kg
Explosion proof and protection l anti explosion: EXd II CT6
2-wire DC powered Conventional Manual Call Point Push Button
The conventional manual call point designed for conventional fire alarm system for reporting fire or emergency
condition by its button latches. The call point has one 300 ohm resistor is used on the PCB board between
Zone+ and Zone- or one relay contact (NO, COM, NC ) output when the button is pressed.
Specifications:
The conventional manual call point designed for
conventional fire alarm system for reporting fire or
emergency condition by pull down the plate. The
manual call point can be reset by a special key
without breaking the glass.
Features
1. Compatible with all the conventional fire alarm control panel
2. Can be reset by key without use a new glass
3. 470 Ohm resistance
4. Easy surface mounting Base included
Specifications
Operating Voltage Range: 9 to 28VDC Volts
Alarm Resistance 470ohm/1W
Operating Humidity Range: 10% to 93% Relative Humidity, Non-condensing
Operating Temperature Range: -10C to 50C (14F to 122F)
Dimensions: Length 140mm, Width 105mm, Depth 45mm
Weight: Net Weight 220g