Please click here to check who's online and chat with them.

Gts Global

Supplier From Turkey
Aug-22-24
Supplier : Transformers, electric and electronic

Services :
Established: 2020 Standards: ISO 9001:2015

Verification Status



Contact Details:
Gaziantep Turkey
Gaziantep 27010
Good Turkey


Recent User Reviews

This user has not received any reviews yet!
 
 
Contact Supplier
Renew

More Items Similiar to: Gts Global

Dec-10-21

Transformers

$770 - $15.40K
MOQ: Not Specified
 
Product Introduction
Capacitive voltage transformer (CVT) in calibration the test must be conducted under the condition of 50Hz frequency complex geographical condition on site at the same time the traditional experiment device is difficult to meet the requirements of on-site handling testing series resonance booster device is first used in domestic field tunable resonance device has been widely used in domestic 500 kv and below the field calibration of capacitor voltage transformer.



Product Parameters
Technical parameters
Rated Capacity 80kVA
rated voltage 160kV
Adjustable inductance range 65~130H
Rated frequency 50Hz
Rated current 0.5A
Adjustable gap range 0~300mm
May-22-23
 
Dear customers,, we are a manufacturer of transformers,
Jun-30-22
 
Rated power: 320kVA
Winding connection: Dyn11
Frequency: 50Hz
Voltage: 22/0,4kV
No-load losses (Po): 390 W
Short-circuit losses(Pk): 3330 W
Maximum no-load current(I0): 2%
Short circuit voltage(Uk ): 6%
Standard: : TCVN 6306 (IEC 60076); Decision 62 / Q EVN
Quality standard: ISO 9001:2015; ISO 14001:2015
Sep-01-22
 
Product description

Transformer Standard current transformer are also called precision current transformers, current transformer standards, standard CT and current transformer standards. Transformer standards are divided into current transformer standards and voltage transformer standards. Standard current transformers are used in the error test of transformers. Used as a current transformer calibration standard



technical parameter

1. Temperature:

2. Relative humidity

3. Rated Primary Current:5-5000A 5A,1A

4.Rated secondary current:5 1A

5 Accuracy Class 0.05S

6. Allow long-term work under the rated current; More than120A across the core.



Precautions:

1. The current of standard CT and tested CT must be the same in CT calibration.

2. Follow the given wiring diagram strictly.

3. Test whether the load box is accurate or not before calibrating the transformer.

4. Forbid secondary winding opening during the calibration.

5. Select demagnetization before calibration.The wiring diagram is shown in figure 5.

Short out the secondary winding before cutting off the power when the demagnetization is finished.

6.Principle wiring diagram of CT with large current generator is similar to above diagram. They are the same except the output winding of large current generator and primary winding of transformer are the same one.
Dec-03-21

Current Transformer

$770 - $15.40K
MOQ: Not Specified
 
Product description

Transformer Standard current transformer are also called precision current transformers, current transformer standards, standard CT and current transformer standards. Transformer standards are divided into current transformer standards and voltage transformer standards. Standard current transformers are used in the error test of transformers. Used as a current transformer calibration standard



technical parameter

Temperature -5 40

Relative humidity 80%

Rated Primary Current 5-5000A 5A,1A

Rated secondary current 5A 1A

Accuracy Class 0.05S
Allow long-term work under the rated current; More than120A across the core.



Precautions

The current of standard CT and tested CT must be the same in CT calibration.

Follow the given wiring diagram strictly.

Test whether the load box is accurate or not before calibrating the transformer.

Forbid secondary winding opening during the calibration.

Select demagnetization before calibration.The wiring diagram is shown in figure 5.

Short out the secondary winding before cutting off the power when the demagnetization is finished.

Principle wiring diagram of CT with large current generator is similar to above diagram. They are the same except the output winding of large current generator and primary winding of transformer are the same one.
Jul-06-22

Transformer

$999
MOQ: Not Specified
Supplier From Amravati, Maharashtra, India
 
Transformer Manufacturers in and , Suppliers and exporters. Our offered Transformers are designed for keeping different customers and their requirements in mind, we use only superior quality raw material while the transformers which make us trusted Transformer Manufacturers in . Being a leading Transformer Manufacturers In we have a wide scope of our items including Control Transformer, Step-down Transformer, etc.
Dec-24-21
 
Overview

In the process of semi finished and finished production of power transformers, before the newly installed transformers are put into operation and according to the state Grid's preventive test rules, it is required to test the transformer's turn ratio or voltage ratio regularly.The traditional variable ratio bridge operation is tedious, the reading is not intuitive, and the necessary conversion, the test result is only one phase change ratio value.The transformer transformer ratio tester overcomes the shortcomings of the traditional transformer ratio bridge test, the screen uses a large screen high resolution LCD screen, convenient to use in the field, with Chinese menu prompt function, simple and intuitive operation, a complete three phase change ratio test, test speed, high accuracy.



Technical parameter

range 0.910000
The accuracy of
reading 0.1 2 words or equal to 500

reading 0.2 2 words 500 3000

Reading 0.3 2 words 3000

The resolution of the
0.9 9.9999 0.0001 100 999.99 0.01 10000 and above 1

10 99.999 0.001 1000 9999.9 0.1

Working power supply AC220V 10 50Hz
Instrument weight 3.5kg
The use of temperature 10 50
Overall dimensions 260mm l 200mm W 160mmH
Relative humidity 90 no dew


Feature

Full three phase sinusoidal inverter output, the output voltage is automatically adjusted, with soft start, soft stop function, so the test speed is fast, high precision

Three-phase transformer, single-phase transformer, PT, Z type transformer ratio, group, polarity test function

Blind test function, that is, variable ratio and group test when high and low pressure connection mode is not known;

CT variable ratio polarity test function

Angle difference test function for single-phase test

Tap position can be tested up to 197
GOLD Member
Mar-01-24

Transformers

$20
MOQ: Not Specified
Supplier From Ludhiana, Punjab, India
 
Transformers,Distribution and Power Transformer,Varivolt
Safety Transformers
Diesel Generators
Industrial Panels
Stabilizers
Energy Saver
Industrial Panels
Feb-03-23
 
factory Linier Variable Differential Transformer (LVDT) HTD-400-6 for power station
is a research and development, production, sales, import agents in one of the manufacturing and processing enterprises. Our company was established in 2004. For more than 20 years, our company's products are widely used in electric power, petroleum, chemical, environmental protection, refractory materials, metallurgy, fire fighting equipment, natural gas, electronics, nuclear industry and other fields. Our company is willing to work with colleagues from all walks of life at home and abroad wholeheartedly cooperation to create a better future power plant, steel spare parts are as follows:

can offer many spare parts for power plants as below:

DF-Linier Variable Differential Transformer (LVDT) HTD-400-6-DF
rotation sensor ZS-03 L90
lvdt 20mm sensor A156.33.01.28
pt100 WZPM-001
Tacho RPM sensor ZS-03 L=90
linear displacement transducer HL-6-600-15
lvdt transducer TDZ-1E-45
lvdt displacement transducer 20000TDGN
lvdt linear position sensor FRD.WJA2.608H
Non-Contact Linear Displacement sensor HTD-200-3
speed meter sensor D075-05-01
speed sensor symptoms IMFCS01
lvdt transducer displacement TDZ-1G-13
Analog Linear Displacement Sensor A157.33.01.3
speed sensor CS-3-M16-L185
thermocouples extension lead wires WRNK-322
sensor de lvdt ZDET-400B
thermowell flange TE-109
thermistor TE-203
lvdt transducer 191.36.09.09
Shaft Rotation Speed Sensors CS-3-L180
inductive displacement sensor A157.33.01.31
stainless steel Thermocouple WRNK2-291
Gear rpm sensor HTC-40D10ES
Sheath Cartridge Heater HY-GYY-1.2-415V/3
temperature measurement sensor pt100 WZPK2-380B
rpm sensor indicator CS-1-AD-B100-C10-D01
lcd speedometer DF9011-B
Gear speed sensor CS-1
Magnetic Pick-up Speed Sensor G-075-02-01
speedometer lcd DM-11B
ptfe pt100 temperature sensor WZPM2-001 �¦5
lvdt position sensor B151.36.09G32
Bimetal Temperature Gauge WTY-1021
pt100 thermal resistance WZPM2-08-67.5-M18-B
Surface Thermocouple WREX2-001
Analog Linear Displacement Sensor TDZ-1-H
Linier Variable Differential Transformer (LVDT) HTD-400-6
angular displacement sensor 6000TDGN-30-01-01
dual sensor rtd WZP-221
5000 rpm torque sensor CS-1 G-100-02-01
temperature sensors WZPK2M-201
lvdt displacement sensor TDZ-FRD-301
displacement inductive sensor B151.36.09.04-006


DFYL-2023-2-3-MY
Mar-11-22
 
Product description

Current transformer field tester was developed with high-end testing technology, large-scale electronic circuit design and accord with national related protocol . It has solved the problem of big working intensity,trival operation while on-site test of current transformer, voltage transformer. Meanwhile the product has a reliable performance,and the function is strong.



Technical index

Verification Status