.1 Description
DEM8900-1/DEM8900-2/DEM8900-3 (short form for DEM8900) is designed by adopting the updated microprocessor and digital signal processing technology, which can be applied for monitoring the electrical system. DEM8900 can measure and analyze the real time electrical parameters, such as I,kWh,kvarh., Meanwhile, DEM8900 has functions of multi-tariff,RS485 communication ( MODBUS protocol),analog output, remote input and electrical pulse output.
All our instruments fulfill all important requirements and regulations concerning electromagnetic compatibility and safety isolation (IEC61000, IEC1010 standard and EN61010 standard). The devices have been developed, manufactured, and tested in accordance with Quality Assurance System ISO 9001.
1.2 Measured parameters
Note 1. DEM8900-1 measure current, active energy, active power (optional, with analog output)
2. DEM8900-2 measure current, reactive energy, reactive power (optional, with analog output)
3. DEM8900-3 measure Current, active energy, reactive energy, active/reactive power (optional, with analog output)
1.3 EMC and Safety standard
IEC61000-4-2 (GB/T17626.2)
IEC61000-4-8 (GB/T17626.8)
IEC61000-4-4 (GB/T17626.4)
IEC61010-1 (GB/T4793.1).
Three Phase Energy Meter with following features
- Dual Source
- Prepaid Function with inbuilt relays
- Whole Current
- Load Curtailment
- Modbus/RS485 Protocol Communication
- 10-60 Amps
Especially developed for indication and
supervision of the three-phase circuit. Provide
three-phase active power, reactive power,
power factor measurement and display, can
expand the measurement range, replaces old
analogical meter, reducing installation
manpower and optimizing the used one of
spaces in the panel.
Ideal for protection of three-phase networks is
monitored and generally to own alarm superior
and inferior. Protection of the parameters of
programming by password.
DDS5558 Single Phase Meter is a kind of new style single phase two wire active energy meter, it adopts micro-electronics technique, and imported large scale integrate circuit, use advanced technique of digital and SMT techniques, etc. It has minimum size, and also a new single phase two wire active energy meter. It has already passed the test of the international authority CE.
The meter completely accords with relevant technical requirements of class 1 single phase active energy meter stipulated in international standard IEC 62053-21. It can accurately and directly measure 50Hz or 60Hz active energy consumption from single phase AC electricity net. This meter has white backlight source eight digits LCD monitors shows the active energy power consumption. It has following features: Good reliability, small volume, light weight, specious nice appearance, convenient installation, etc.
Features:
Bi-directional total active energy measurement
25mm standard DIN rail installation, complying with standard DIN En50022.
Single pole width (Modules17.5mm), complying with standard DIN43880.
Small modular size, DIN rail mounted.
Easy installation to distribution boards, load center, miniature & etc. by identifying where energy is being used.
Application:
All power parameter measurements;
Energy measurement and electrical fire monitor and control;
Replacing the three-phase power meter, three-phase electricity transmitter;
Transformers, generators, capacitors, and electric motors distributed detection;
Medium and low-pressure systems;
SCADA, EMS, DCS integrators.
Product description
Three-phase electric energy meter calibrator is used for grid corporation of measurement and energy test center, management department of power supply bureau, national energy measurement of testing authorities, and also used to test each kind of single/three-phase kWh meter of industries and mining enterprises as well as electric meter manufacturers. Meanwhile, the calibrator also can be used as one high-precision standard power source.
Technical index
Electrical parameters
Accuracy
0.05%, 0.1%
Power Supply
One Phase AC 180-265V, frequency 50/60Hz.
AC Voltage Output
Range(U1,U2,U3)
57.7V, 100V, 220V, 380V
or 69.3V, 120V, 240V, 480V( optional)
Adjustment range
(0-120)%RG(1)
Adjustment �neness
0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Especially developed for indication and
supervision of the three-phase circuit, can
expand the measurement range, replaces
old analogical meter, reducing installation
manpower and optimizing the used one of
spaces in the panel.
Ideal for protection of three-phase
networks is monitored and generally to
own alarm superior and inferior. Protection
of the parameters of programming by
password.
Especially developed for indication and
supervision of the three-phase circuit, can
expand the measurement range, replaces
old analogical meter, reducing installation
manpower and optimizing the used one of
spaces in the panel.
Ideal for protection of three-phase
networks is monitored and generally to
own alarm superior and inferior. Protection
of the parameters of programming by
password.