Size DN3-DN3000
Electrode:SS316,HC,HB,Ti,Tan,Pt
Liner Material: PTFE,PFA,FEP,NEOPRENE,HARD RUBBER
Accurance: 0.5% of reading velue,0.3% and 0.2% optional
Connection: Flange,Tri-clamp,Wafer,Union
Introduction
Electromagnetic flow meter is hallmarked by its high performance and reliability based on successful, field-proven technology.
It is being widely used in industries such as petroleum, chemical engineering, iron and steel, food, electricpower, paper making,
water treatment, petrochemical, medicine etc
Features
Medium temperature can be -20~200.
Integrated vertification, diagnostic function and empty pipe detection.
Measure forward and reverse direction flows.
Built-in reference electrodes, no need to connect ground ring.
Dual frequency excitation and stable zero point.
Precision coil winding technology, makes magnetic field more uniform.
High protection grade,IP65.
No moving parts, no pressure loss.
High accuracy: ±0.5% of reading,±0.3% and ±0.2% optional, velocity >0.3 m/s.
Application
Chemical
Medicine
Beverage
Iron and steel
Water supply
Electricpower
Water treatment
Our Electromagnetic Flow Meter accurately measures the flow rate of conducting liquids or slurries flowing in closed pipes. Due to simple and right design the Electromagnetic Flow Meter is an obstruction-less & maintenance-free instrument in place of conventional mechanical flow measuring device. The use of "Pulsed DC" technology offers highest ability & better measuring accuracy in form of 4-20 mA DC linearly proportional to volumetric flow
Features :
Size DIN 10 to DIN 3000 NB pipe line.
High Accuracy better than + 0.5% of reading.
Zero pressure drop.
Suitable for high viscosity conductive liquids.
Digital flow rate / Totalizer Indication / Batching system
Isolated Transmitting Output 4-20 mA.
No Grounding Rings require.
Minimum Upstream & Downstream straight length.
Compact & Rugged, IP 65 protection.
Remote flow indication totalizer / Batching system
Data Logging & Wireless Data Transfer System through GSM Modem
Applications :
Effluent Treatment Plants.
Sewage Treatment Plants.
Water supply schemes.
Steel & aluminum.
Pulp & Paper.
Chemical & Fertilizers.
Food & Drug.
Pumps & valve calibration lab.
Dairy Industry.
Corrosive liquids.
Sugar industry.
Sugar Industry.
Textile and printing textiles
Hotels & Resorts
Water parks
Buildings & Infrastructure
Municipal corporation
Sea river measuring waste water treatment diving open channel electromagnetic flowmeter
Electromagnetic Flow Meter Chemical Industry, Orifice Plate Flowmeter, High Quality flowmeter
Quick Detailsï¼?
Place of Origin Henan, China (Mainland) Brand Name WEILI Model Number MGG
Accuracy ±0.5% ~ ±1.5% Application Widely Name waste water treatment diving open channel electromagnetic flowmeter
Product Name Orifice plate flowmeter Power supply DC24 V/220VAC 50HZ measurement accuracy ±1cm(Pillar diameter 1cm)
Output 4-20mA /RS485 Medium Sewage Material SS304
Product Descriptionï¼?
Magne W3000 PLUS Diving type electromagnetic flowmeter is mainly used for flow rate measurement in open or closed channels .This flowmeter has been widely used in departments of water supply and sewage in towns ,industrial waste water sewage ,sewage management ,farmland irrigation ,etc.
Characteristicsï¼?
1.The body is made of plastics ,resulting in light and corrision resistant structure .
2.The structure is simple and without moving parts .The flowmeter have sturdy resistance against staining,dogging or eroding if a fluid contains suspensions or adherents .
3.The sensor can also be easily installed on any gate of an exsisting water channel .The channel may be an open or closed type with retangular or circular cross section .
4.The flow signal is linear ,having a high measuring accuracy from 100% down to zero flow rate .Stable measurement can be done even when the channel is affected by the tide .
Technical Parametersï¼?
Nominal Bore: DN50,100,200,400,600,800mm
Measuring range 0 ~ 1m/s to 0 ~ 10m/s(Flow velocity)
Max diving depth 10m
Accuracy ±1.0%;±2.0%
Measuring Electrodes 316L Stainless steel , Harrington alloy B/C, Titanium , or special material
Medium Temperature 0 ~ +40
Output signals of sensor 0 ~ 0.2mVp ~ p to 0 ~ 2mVp ~ P
Output signals of the flowmeter 4 ~ 20mA.Dc and 0 ~ 5000Hz or 0 ~ 2000Hz
Electrical conductivity �5μs/cm
Electronet series ELMAG-200 are micro-controller based full bore type electromagnetic flow meters specially used for various industrial applications. These flow meters accurately measure the flow rate of conductive liquids & slurries in closed pipes.
Due to its simple and rigid design, the flow meter is an obstruction-less and maintenance-free instrument in place of conventional mechanical flow measuring devices. The use of 'Pulsed DC' technology offers highest ability and better measuring accuracy in the form of electrical signal 4-20 mA DC linearly proportional to volumetric flow.
A magnetic field is generated by the instrument in the flow tube. The fluid flowing through this magnetic field generates a voltage that is proportional to the flow velocity. Corresponding electrical output is provided with respect to measuring flow range.
Electronet series ELMAG-2516 are micro-controller based full bore type electromagnetic flow meters specially used for various industrial applications. These flow meters accurately measure the flow rate of conductive liquids & slurries in closed pipes. The use of 'Pulsed DC' technology offers highest ability & better measuring accuracy in the form of electrical signal 4-20 mA DC linearly proportional to volumetric flow.
Diameter DN3 to DN3000
Accuracy 0.5;1.0
Flow rate range 0.1~15m/s
Conductivity =5µm/s
Fluid temperature Ordinary rubber liner -20~+60?
High temperature rubber liner -20~+90?
Ptfe liner -30~+100?
High temperature Ptfe liner -30~160?
Power supply: 24VDC;220VAC
Straight pipe requirements Pipe type: upstream=5D,downstream=3D
Connection mode : Flange connection are between flow meter and piping that follows GB11988 rules
Explosion-proof grade: Exd?CT4
Display : LED displayer
Electromagnetic flowmeter is composed of sensor and converter. It has two forms: compact-type and remote-type. The remote-type also needs a special double-layer shielded cable to connect the converter and the sensor. There are seven kinds of electrode materials and four kinds of lining materials available for sensor.