DC Input Motion Sensor Module
Standard Motion Sensor Module
5V/12V DC Input Microwave Motion Sensor - Standard Version
HNS101D
5.8GHz C-band microwave, tri-level dimming function.
Input voltage 12V DC (5V & 24V DC version available on request).
Input current:25mA.
Features
5.8GHz C-band microwave, tri-level dimming function.
Input voltage 12V DC (5V & 24V DC version available on request).
Input current:25mA.
5V DC PWM output or 0~10V DC signal.
Super compact, flexible to be integrated into any suitable fixtures.
Dual-PD technology, real Dayligh t m onitoring function for built-in application.
8 pin DIP switch setting, multiple options to meet different customer demands.
Detection range up to 12m in diameter.
Mounting height: 3~6m.
Operation temperature; -20? ~ + 70?.
RoHS compliant.
Settings
Detection range
Detection range can be reduced by selecting the combination on the DIP switches to fit precisely each application.
Hold-time
Hold-time means the time period to keep the lamp on 100% after motion detected.
*when hold-time set as 3s, sensor enters into test mode, this test mode is mainly for users to choose the desired detection range. In this mode, the daylight sensor is disabled, when there is no motion, fixture keeps off, when there is motion detected, fixture keeps a cycle of 3s on and 2s off.
Daylight sensor
Daylight sensor means the daylight threshold to enable or disable the sensor function.
"Disable": The sensor works always, even during daylight.
w50lux": The sensor works only in twilight.
w10lux, 2luxw: The sensor works only in the dark.
Stand-by period
This is the time period that the lamp remains at a low light level before it is completely switched off in the long absence of people.
?+? means bi-level dimming control, the fixture never switch off.
Stand-by dimming level
This is the dimmed low light level you would like to have after the hold-time in the absence of people.
Daylight monitoring function
Utilizing the Dual-PD technology, this sensor can tell the difference of natural light and artificial light(lamp) from behind the diffuser, switch on automatically(even without movements) when the ambient light is below target value, and then switch off automatically whenever the artificial light is not required(ambient light is bright enough).
This is the REAL & INTELLIGENT daylight monitoring sensor for built-in installation.
Note: Lux-Off sampling time?30s; Lux-On sampling time?10s.
Lux-On function takes effect only when standby dimming period set at.
DC Input Motion Sensor Module
Standard Motion Sensor Module
5V/12V DC Input Microwave Motion Sensor - Standard Version
HNS101D
5.8GHz C-band microwave, tri-level dimming function.
Input voltage 12V DC (5V & 24V DC version available on request).
Input current:25mA.
Features
5.8GHz C-band microwave, tri-level dimming function.
Input voltage 12V DC (5V & 24V DC version available on request).
Input current:25mA.
5V DC PWM output or 0~10V DC signal.
Super compact, flexible to be integrated in t o any suitable fixtures.
Dual-PD technology, real Daylight monitoring function for built-in application.
8 pin DIP switch setting, multiple options to meet different customer demands.
Detection range up to 12m in diameter.
Mounting height: 3~6m.
Operation temperature; -20? ~ + 70?.
RoHS compliant.
Settings
Detection range
Detection range can be reduced by selecting the combination on the DIP switches to fit precisely each application.
Hold-time
Hold-time means the time period to keep the lamp on 100% after motion detected.
*when hold-time set as 3s, sensor enters into test mode, this test mode is mainly for users to choose the desired detection range. In this mode, the daylight sensor is disabled, when there is no motion, fixture keeps off, when there is motion detected, fixture keeps a cycle of 3s on and 2s off.
Daylight sensor
Daylight sensor means the daylight threshold to enable or disable the sensor function.
"Disable": The sensor works always, even during daylight.
w50lux": The sensor works only in twilight.
w10lux, 2luxw: The sensor works only in the dark.
Stand-by period
This is the time period that the lamp remains at a low light level before it is completely switched off in the long absence of people.
?+? means bi-level dimming control, the fixture never switch off.
Stand-by dimming level
This is the dimmed low light level you would like to have after the hold-time in the absence of people.
Daylight monitoring function
Utilizing the Dual-PD technology, this sensor can tell the difference of natural light and artificial light(lamp) from behind the diffuser, switch on automatically(even without movements) when the ambient light is below target value, and then switch off automatically whenever the artificial light is not required(ambient light is bright enough).
This is the REAL & INTELLIGENT daylight monitoring sensor for built-in installation.
Note: Lux-Off sampling time?30s; Lux-On sampling time?10s.
Lux-On function takes effect only when standby dimming period set at+?
Introduction
Irm300 is one of the general ndir co2 gas modules, which adopting ndir principle, consists of carefully designed light chamber, precise electric circuit and intelligent software. With the help of single light source, dual channel detector, and
Unit
Storage temperature
Tstg
-20 to 80
¡ãc
Working temperature
Ta
0 to +50
¡ãc
Working humidity
Ha
0 to 90
% rh
Working pressure
Pa
0.8 to 1.2
Atm
Electric characteristics
Description
Symbol
Min.
Typical
Max.
Unit
Supply power
Vs
4.6
5
5.4
V
Maximum current
Imax
130
160-
Ma
Light current
Iavg
60
70
Ma
Frequency
F
0.2
1
2
Hz
Preheat time
Twarm
90
120
180
Sec
Performance characteristics
Description
Min
Typical
Max
Unit
Detection range
0
2000
50000
Ppm
Detection accuracy
-
¡¨¤60ppm¡¨¤5% fs
-
Ppm
T90
Diffusing
-
60
90
Sec
Pumping
-
10
20
Sec
Repeatability
Zero
SH-300-NDC NDIR CO2 Sensor Module Features
* Best Extremely Precise Sensor
* Quick Response Time
* Long Time Use, Stable performance at High & Low Temperature
* Waterproof Filter for anti static filters fine dust and humidity in the air
* One-way air indraft for represent average value when momentary CO2 Value change in the air
* Low Current consumption
* Output support: UART, 0~3V Analog
SH-300-NDC NDIR CO2 Sensor Module Application
* CO2 Control for Indoor Air Quality
* CO2 Measuring for Ventilation Control
* CO2 Control for Building, Hospital, School
* CO2 Control for Air cleaner, Air conditioner.
* Mushroom Control, Boiler Control
HG-P40C Ultrasonic Proximity Sensor & Module Description
* Using only a single transceiver sensor unit for transmit and receive signals.
* Convenient for distance measuring and object detection.
* Two types of transmit mode for convenience.
- Free Run : With a power supply, sensor transmits trigger and burst signal itself - for basic application
- External Trigger : External system(controller or processor circuit) controls the trigger signals - for advance application(distance measure)
* Two types of input power - Low(5V) for processor circuit usage and High(12V) for controllers.
* Four different output signal (simultaneously).
- Real time ultrasonic wave amplified from actually received ultrasonic. (for sound pressure measuring)
- Real time TTL level square signal(Square Wave) of detection signal. (for robots)
- Distance pulse width signal which is proportional to the nearest object from the sensor. (for robots and distance measuring)
- Proximity output signal(10mA current) within the preset range(0.5~4.5m) (for industrial use)
- Preset range is adjustable from 0.5 to 4.5 m. (factory distance preset available for volume orders)
* High performance ASIC Chip for stable transmission and sensitive reception. (Max. approx. 4,000 times amplification)
HG-P40C Ultrasonic Proximity Sensor & Module Features
* Multi functional transceiver model
* Two types of transmit modes (Free Run / External Trigger)
* Power Supply (Low : 5V / High : 6~16V)
* 4 different output signals (simultaneously)
- Real time received and amplified ultrasonic wave
- Real time TTL square signal
- Distance pulse width signal
- Detecting objects within the preset range(proximity)
* High performance ASIC Chip
HG-P40C Ultrasonic Proximity Sensor & Module Specification
* Input DC: Low : 5V / High : 6~16V
* Current consumption (when 12V is used)
- 12mA (Standby Mode)
- 18mA (When an object is detected within the range)
- 28mA (Proximity signal 10mA deducted)
* Distance Range (at flat plate)
- 0.4~3m (when 5V is used)
- 0.4~6m (when 12V±3V is used)
* Size
Module : 20x36x20(mm)
Sensor : Φ16
HG-P40C Ultrasonic Proximity Sensor & Module Description
* Using only a single transceiver sensor unit for transmit and receive signals.
* Convenient for distance measuring and object detection.
* Two types of transmit mode for convenience.
- Free Run : With a power supply, sensor transmits trigger and burst signal itself - for basic application
- External Trigger : External system(controller or processor circuit) controls the trigger signals - for advance application(distance measure)
* Two types of input power - Low(5V) for processor circuit usage and High(12V) for controllers.
* Four different output signal (simultaneously).
- Real time ultrasonic wave amplified from actually received ultrasonic. (for sound pressure measuring)
- Real time TTL level square signal(Square Wave) of detection signal. (for robots)
- Distance pulse width signal which is proportional to the nearest object from the sensor. (for robots and distance measuring)
- Proximity output signal(10mA current) within the preset range(0.5~4.5m) (for industrial use)
- Preset range is adjustable from 0.5 to 4.5 m. (factory distance preset available for volume orders)
* High performance ASIC Chip for stable transmission and sensitive reception. (Max. approx. 4,000 times amplification)
HG-P40C Ultrasonic Proximity Sensor & Module Features
* Multi functional transceiver model
* Two types of transmit modes (Free Run / External Trigger)
* Power Supply (Low : 5V / High : 6~16V)
* 4 different output signals (simultaneously)
- Real time received and amplified ultrasonic wave
- Real time TTL square signal
- Distance pulse width signal
- Detecting objects within the preset range(proximity)
* High performance ASIC Chip
HG-P40C Ultrasonic Proximity Sensor & Module Specification
* Input DC: Low : 5V / High : 6~16V
* Current consumption (when 12V is used)
- 12mA (Standby Mode)
- 18mA (When an object is detected within the range)
- 28mA (Proximity signal 10mA deducted)
* Distance Range (at flat plate)
- 0.4~3m (when 5V is used)
- 0.4~6m (when 12V±3V is used)
* Size
Module : 20x36x20(mm)
Sensor : Φ16
Ee893 digital co2 sensor module for oem applications
The e+e co2 module ee893 is designed for oem applications and for demanding environment. A multiple point co2 and temperature adjustment procedure leads to excellent co2 measurement accuracy over the entire temperature working range; this is a must for process control and outdoor applications.
The e+e dual wavelength ndir co2 sensing procedure compensates automatically for ageing effects. Ee893 is highly insensitive to pollution and offers outstanding long term stability.
With its small dimensions and electrical connection via contact pins and pads, ee893 is the optimal choice for oem devices such as wireless transmitters, hand-helds or data loggers. The measured data, with a range of up to 10000ppm, is available on the e2 digital interface.
An optional kit facilitates easy configuration and adjustment of the module. The measurement interval can be set according to the application requirements; by this the average current consumption can be reduced to less than 60î¼a for battery-operated devices.
Ee893 digital ndir co2 sensor module typical applications
* data loggers
* hand helds
* wireless transmitters
* building management
* demand controlled ventilation
Ee893 digital co2 sensor module key features
* autocalibration
* outstanding long-term stability
* temperature compensation
* low power consumption
* very small size
Ee893 digital ndir co2 sensor module technical data
* co2 working range: 0 - 2000 / 5000 / 10000ppm
* supply voltage: 4.75 - 7.5v dc
* average power consumption: 58âµa ~ 3.7ma
* calibration interval: >5 years
* operation temperature: -40~60'c (-40~140'f)
* operation humidityâ??: 0~95% rh (not condensating)
* operation pressure: 85~110kpa (12.33 ~ 15.95psi)