A&s transmitter co., ltd. Provide all types of emerson/rosemount pressure transmitters
Rosemount pressure transmitters 3051cd
Rosemount pressure transmitters 3051cg
Rosemount pressure transmitters 3051ca
Rosemount pressure transmitters 3051tg
Rosemount pressure transmitters 3051ta
Rosemount pressure transmitter 3051s
Rosemount pressure transmitters 3051l
Etc.
Besides rosemount 3051 pressure transmitters, we can also help you with other rosemount transmitters as follows:
Rosemount 2051 pressure transmitters
Rosemount 1151 pressure transmitters
Rosemount 5300 series pressure transmitters
Rosemount 5400 series pressure transmitters
Rosemount 3100 series pressure transmitters
Rosemount temperature transmitters.Etc.
Since 1969, the innovative rosemount 1151 pressure transmitter has provided the process control industry with unsurpassed service. With over four million transmitters in service worldwide, the 1151 continues to offer industry leading value and quality. The rosemount 1151 is world-renowned for proven field performance, reliability, and longevity.
1151 transmitter:
The 1151 transmitters bring true precision and measurement to differential, flow, gage, absolute, vacuum, liquid level, and specific gravity applications. Compact design, integral junction box, and local span and zero adjustments simplify installation, calibration, and commissioning.
Rosemount metric style rtds are highly linear and have a stable resistance versus temperature relationship. These temperature sensors are used primarily in industrial environments where high accuracy, durability, and long-term stability are required.
Enhanced performance and optimal temperature measurement accuracy is available for series 65 pt100 temperature sensors coupled with a range of smart temperature transmitters through calibration schedules and callendar van dusen constants.
A sanitary offering is also included through the 65q model, offering sanitary process connections, polished sst connection heads, and greater response time. Every metric style rtd is part of our global network ensuring a globally consistent, high quality product every time.
A&S Transmitter Co., Ltd. provide all types of Yokogawa Pressure Transmitters:
Yokogawa Y/11AL Pneumatic Absolute Pressure Transmitter,
Yokogawa P10 series pneumatic pressure transmitters,
Yokogawa DPharp EJX series pressure transmitters,
Yokogawa DPharp EJA-E series pressure transmitters,
Yokogawa DPharp EJA series pressure transmitters,etc.
Model:
Yokogawa Temperature Transmitter YTA110
Yokogawa Temperature Transmitter YTA310
Yokogawa Temperature Transmitter YTA320
Yokogawa Temperature Transmitter YTA70
Yokogawa Temperature Transmitter YTA50
1. All the supplied products are provided with product certificates and instructions, including product number, technical parameters, wiring diagram,factory date, etc. Please check carefully to avoid misuse.
2. Installation should check whether the field interface is connected to the product according to the connection mode and thread type of the product.The mouth is the same. If it is a threaded interface, it should be tightened slowly and sealed carefully. Torque can not be added directly to the transmitter shell, but only on the six sides of the pressure interface.
3. The wiring should be strictly in accordance with the instructions of our company.
4.This product is a precise instrument. It is forbidden to disassemble, colide,fall,throw hard or punch the drainage hole with a sharp instrument.
5. The transmitter can work by electricity, but the preheating output is stable for 30 seconds.
6. If any abnormality is found in use, the power supply should be turned off, the use should be stopped, the inspection should be carried out, or contact our technical department direct.
7.When transporting and storing, the original packaging should be restored and stored in a cool, dry and ventilated warehouse.
8.The quality assurance period is 12 months.
Intelligent Operation Method
1. LCD shows the output percentage or process pressure. Press the S key to select the display percentage or pressure.Press Z key to select pressure unit KPa or Mpa when displaying pressure.
2. Press S+Z key for 8 seconds, then release it at the same time, press Z key to set the zero value; Press the S key set the range. note: this function can only be triggered once an operation.
3. Adjustments to zeros or ranges may cause changes in the displayed options, i.e.The percentage being displayed becomes pressure or KPa becomes Mpa, etc. All these changes are shown only in the display, and have no effect on the internal parameters of the transmitter, pressure detection and current output. After adjusting the zero point and range, the S and Z keys can be used to select the desired percentage or pressure.
4. Zero-setting in field pressure-free state: 30 seconds after pressing S+Z key, the display shows zero time at the same time release the two keys, that is, zero.
Simulated operation method
1.Zero-setting in pressure-free condition: The potentiometer with the word "zero" on the circuit board is adjusted to zero when it is displayed on the spot.(Note: Clockwise increase, counterclockwise decrease)
2.The potentiometer marked "range" on the circuit board can not be adjusted without standard pressure, so as to avoid the disorder of measurement range.