The AF Series 1-stack 3-pole contactors are of the block type design. Main poles and auxiliary contact blocks: 3 main poles, 1 built-in auxiliary contact, front and side-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) - Control circuit: AC or DC operated - Accessories: a wide range of accessories is available
UA16-30-10 RA UA26-30-10 AF9-30-10 AF1250-30-11
UA16-30-10 RA UA26-30-10 AF12-30-10 AF1350-30-11
UA16-30-10 RA UA26-30-10 AF16-30-10 AF1650-30-11
UA16-30-10 RA UA26-30-10 AF26-30-11 AF2050-30-11
UA26-30-10 RA UA30-30-10 AF30-30-11 AF2650-30-11
UA26-30-10 RA UA30-30-10 AF40-30-11 A9-30-11
UA26-30-10 RA UA30-30-10 AF50-30-11 A12-30-11
UA26-30-10 RA UA30-30-10 AF63-30-11 A16-30-11
UA30-30-10 RA UA50-30-00 AF75-30-11 A26-30-11
UA30-30-10 RA UA50-30-00 AF95-30-11 A30-30-11
UA30-30-10 RA UA50-30-00 AF110-30-11 A40-30-11
UA30-30-10 RA UA50-30-00 AF116-30-11 A50-30-11
UA50-30-00 RA UA63-30-00 AF140-30-11 A63-30-11
UA50-30-00 RA UA63-30-00 AF145-30-11 A75-30-11
UA50-30-00 RA UA63-30-00 AF146-30-11 A95-30-11
UA50-30-00 RA UA63-30-00 AF185-30-11 A110-30-11
UA63-30-00 RA UA75-30-00 AF205-30-11 A145-30-11
UA63-30-00 RA UA75-30-00 AF210-30-11 A185-30-11
UA63-30-00 RA UA75-30-00 AF260-30-11 A210-30-11
UA63-30-00 RA UA75-30-00 AF265-30-11 A260-30-11
UA75-30-00 RA UA95-30-11 AF300-30-11 A300-30-11
UA75-30-00 RA UA95-30-11 AF305-30-11 A320-30-11
UA75-30-00 RA UA95-30-11 AF370-30-11 AF460-30-11
UA75-30-00 RA UA95-30-11 AF400-30-11 AF580-30-11
UA110-30-11 UA110-30-11 UA110-30-11 AF750-30-11
UA110-30-11 UA110-30-11 UA110-30-11
GSC1 series AC Contactors are used in the circuit of 50Hz or 60Hz frequency with rated current up to 95A under usage category AC-3 at 380V AC. These AC contactors comply with IEC60947-4:
Rated Isolation Voltage: up to AC690V
Rated Voltage: 220V AC or 380V AC or 415V AC or 440V AC or 660V AC
Rated Current under usage category AC-3 at 380V AC (A) : 9A, 12A, 18A, 25A, 32A, 38A, 40A, 50A, 65A, 80A, 95A
Series ac contactor is suitable for using in the circuits up to the rated voltage 660v ac 50hz, rated current up to 95a, for making, breaking, frequently starting & controlling the ac motor. Combined with the auxiliary contact block, timer delay & machine-interlocking device etc, it becomes the delay conactor, mechanical interlocking contactor, star-delta starter. With the thermal relay, it is combined into the electromagnetic starter. The contactor is produced according to iec947-2, vde0660 & bd5452.
1. GMC electrical magnetic ac contactor is suitable for using in the circuits up to the rated voltage 660V AC 50HZ or 60HZ, rated current up to 95A, for making frequently starting & controlling the AC motor.
2. 09-220A GMC AC Contactor can be Combined with the auxiliary contact block, thermal relay & machine-interlocking device etc, it becomes the delay contactor, mechanical interlocking contactor, star-delta starter.
3. With the thermal relay, it is combined into the electromagnetic starter.
CJX2(LC1-F 3) Magnetic Contactor ac contactor is applicable in the circuit rated voltage up to 1000V AC. 50Hz or 60Hz,rated current up to 780A, for long distance breaking circuit and frequently starting or controlling the motor. It also can be used for the control of distributing circuits of rated current from 200A to 1600A.(AC-1)/115A to 780A(AC-3)
CJ40 3P magnetic motor starter ac contactor is mainly used for AC 50Hz (or 60Hz), rated voltage to 660V (or 1140V, rated
current of 1000A connected to power lines and breaking the circuit, and can with the appropriate thermal
relay or electronic protection device combined into electromagnetic starter in order to protect the circuit
overload that may occur.
Products comply with GB14048.4, IEC 60947-4-1, and GB21518-2008 "AC contactor limit value of energy
efficiency rating and energy efficiency rating.