Supplier: Gas lighter, led screen protector ( not even in domestic ), refill paper cups, table runner, earing brass clamp, auto brass electric parts, cashew nuts, wire mesh, petha sweet, niwar, mohini powder, vermicompost, dry bath incubator, test tube plastic, sordium citrate tube, health care product, ornamental freshwater fish, safed musli, used polymer bag, cotton linter, auto hood cover,
areca plate, rice
PE coil pipes and tubes for water and wire cable conduit PL231
The PE coil pipes and tubes can be used:
water pipe 4 â?? 6 â?? 1-inch black coil with pressure 1.6mpa, OD 20-75mm, WT 2.3-6.8mm
pe conduit cable embedded wire cable and optical cable, OD 20-200mm, WT 1.8-3.5mm
weak current protection tube and communication tube, OD 20-200mm, WT 1.8-3.5mm
We use new 100% pure raw PE material
WHY NEW MATERIAL HDPE PIPES?
1. Health performance
PE pipe processing without adding heavy metal salt stabilizer, no scaling layer, and no bacteria.
2. Corrosion resistance
It can resist various chemical media erosion, with no electrochemical corrosion.
3. Service life
Under rated temperature and pressure conditions, PE pipes can be used for more than 50 years.
4. Impact resistance
PE pipe toughness, high impact strength, heavy objects directly pressed through the pipeline will not break.
5. Connection performance
The strength of the hot melt or electric melt interface of the polyethylene HDPE pipe is higher than that of the pipe body, and the joint will not be broken due to soil movement or live load.
6. Construction performance
It has a lightweight pipe weight, a simple welding process, convenient construction, and a low overall project cost.
AC to DC converter battery charger 150-1000VDC rectifier 120KW power supply
Product Introductionï¼?
SANDI AC/DC Charger is specially developed for DC chargers. It has high efficiency, high power factor, high power density, high reliability advantage. AC input 3 phase, DC output voltage range from 150 to 1000VDC can be set, compliant with CE safety requirements, EMC standard EN61000-6-3 and EN61000-6-1 Class A, it is an advanced international level charger.
Unique function
High efficiency over the full load range, full load efficiency greater than 95%
Wide output voltage range, 150-1000VDC, suitable for a wide range of Lithium or lead acid battery
5-inch LCD touch screen, easy to operate
Flexible application, charging voltage, charging current, charging time, timing charging can be set by LCD screen, easy to operate
Main featuresï¼?
Powerful protection, overheating, short circuit, overload, overvoltage, undervoltage, etc.
Wide input voltage range: 260~ 530Vac, adaptable to various power grid environments
Three-phase AC input without neutral wire: Simplifies system design, eliminates the risk of excessive neutral current, and reduces system costs.
Dual DSP design, achieve the full digital control, less components means high reliability
Wide input voltage range, allows operation in most poor grid conditions
Battery anti backflow: effectively protects the battery while ensuring reliable and safe operation of the system
Input, output have protective circuit breaker switch
Module adopts hot pluggable design, which is convenient for maintenance.
RS485 interface (Optional)
SANDI SERIES charging module is for electric vehicle charging station. With single-phase non neutral conductor AC input, it has the advantages of high efficiency, high power density and low harmonic.
Functional details
1. Hot plug
Plug technology is applied to the charging module to provide convenience for installation and maintenance. The access of the charging module to the system shall not disturb the output voltage of the system.
2. Advanced current sharing technology
Under constant voltage working mode, the charging modules can share current automatically within 10S, with degree of unbalance less than �±0.5A.
3. Control of input limited power
Refer to Fig. 1-10 for the relation between the output power and input voltage of the charging module. When the input voltage is within 360 Vac ~ 450 Vac (return difference is less than 5V), the module can output the maximum power of 20 KW; when the input voltage is within 260 Vac ~ 320 Vac, the module can still work normally under limited power mode.
4. Control of output constant power
When there is a rated input voltage, the output power of the module is 20 KW. Refer to Fig. 11 for the relation between the output voltage and the output current of the module.
The SD75050 module uses two operating modes with output voltage ranges of 50 to 750V.
The module only selects the operating mode based on the value of the received demand voltage, and does not select the operating mode based on the actual output voltage.
5. Temperature limited power
6. Regulation of output current limiting point
8. Regulation of output voltage
The output voltage of the module can be regulated constantly through the external monitoring module, with regulation range of 50Vdc ~ 750Vdc and minimum regulation step of 0.1 Vdc.
9. Fan control
The built-in processor of the module can regulate the speed of the fan according to the internal temperature and output current of the module.
10. Protection of input overvoltage/ voltage shortage
11. Output overvoltage protection
The overvoltage protection point is 260Vdc ~770Vdc (�±10 Vdc). Default is 778Vdc.The module can be started after manual intervention upon overvoltage protection.
12. Over-temperature protection
The environmental over-temperature protection point is 80�°C. When the DC panel has a temperature over 100�°C, the module will stop working; when the DC panel has a temperature below 90�°C, the module will automatically work again.
13. Protection of internal bus fault
When the internal bus voltage of the module is beyond the overvoltage/ voltage shortage protection point, the module will be powered off automatically. At this time, there is no output from the module and the fault indicator light is on.
14. Short circuit protection
In case of short circuit of the module, it will be subjected to protective shutdown and the red indicator light of the panel is on, and this condition will be transmitted to the monitor of the "module fault".
ALSTOM GBCDG61EG040SGCH
IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S
Relay Technical specification
Relay model no CDG61EG040SGCH
Relay type CDG 61
Case size 3D HOR.
Application 2 O/C & 1 E/F
Current setting - O/C 2.5 to 10 amps
Aux.Contacts With Flag 3M S/R
Output contacts 2M S/R
C.T.Secondary 5 amps
Frequency 50 Hz
Burden 3 VA
Operating time 1.3 secs
Current setting - E/F 0.5 to 2 amps
High set - O/C Setting 20 to 80 amps
High set - E/F Setting 5 to 20 amps
High set conts.With flag CAG 13 / 2M S/R
Name plate RFG9125 903
Outline drawing MFJ 014
Wiring diagram MADZ 821.27-1
ALSTOM GBCDG61EG041SGCH
IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S
Technical specification
Relay model no CDG61EG041SGCH
Relay type CDG 61
Case size 3D H 30T
Application 2 O/C & 1 E/F
Current setting - O/C 2.5 to 10 amps
Contacts / Output contacts 3M S/R / 2M S/R
C.T.Secondary 5 amps
Frequency 50 Hz
Burden 3 VA
Operating time 3 secs
Current setting - E/F 0.5 to 2 amps
High set - O/C Setting 20 to 80 amps
High set - E/F Setting 5 to 20 amps
High set CAG 13
Name plate RFG9126 903
Outline drawing MFJ 014
Wiring diagram MADZ 821.27-1