Please click here to check who's online and chat with them.

Find Verified 11Kv Transformer Bushing Din 42531 Suppliers, Manufacturers and Wholesalers

Apr-03-19
 
We manufacture transformer bushings for outdoor and indoor applications and our manufacturing program includes the following ranges :

1. Low voltage bushings in accordance with DIN 42539
- 1 kV , 250 A Low voltage bushing AB-250
- 1 kV ,630 A Low voltage bushing AB-630
- 1 kV ,1000 A Low voltage bushing AB-1000
- 1kV, 2000 A Low voltage bushing AB-2000
- 1 kV,3150 A Low voltage bushing AB-3150
2. Medium voltage Bushings in accordance with EN50180 & DIN42531
- 12.5kV,250A Indoor type transformer bushing 10Ni-250A
- 12.5 kV,250A Outdoor type transformer bushing 10Nf -250A
- 24 kV ,250A Outdoor type transformer bushing 20NF-250A
- 36 kV,250A Outdoor type transformer bushing 30NF-250A
Oct-08-20
 
Hebei Anmei produce kinds of DIN standard , ANSI standard , AS standard transformer bushing insulator, oil level gauge and transformer accessorise
Jun-02-16
 
JDZX10-12 voltage transformer, epoxy resin casting and single pole insulated VT, is widely used indoor for measuring current, electric energy and protective relaying in the isolated neutral system with the frequency 50-60Hz and highest voltage for equipment 12 kV.







Usage Terms
J: Voltage transformer
D: Single-phase
Z: Casting insulation
X: Residual voltage winding
10: Design No.
12: Rated voltage
Main technical parameter
1. Rated primary voltage:11/kV or 10/kV etc.
2. Rated secondary voltage:100/V?110/V ? 115/V? 120/V
3. Rated voltage of residual voltage windings:100/ 3V ?110/ 3V? 115/ 3V? 120/ 3V
4. Burden power factor: cosF=0.8(lagging)
5. Standards: IEC60044-2.2003 Instrument transformers-Part2: Inductive Voltage transformers
Other technical parameters pls see as follow:
x1204.png
Remarks: Upon request we are glad to offer transformers according to other standards or with non-standard technical specs.
Jun-02-16
 
LZZBJ9-12A1(A2) current transformer, epoxy resin casting insulation and fully enclosed support construction, encloses primary & secondary windings and annular core in the epoxy resin casting body. The product has the feature of light weight, omni-directional installation, withstanding nastiness and dampness. It is widely used for measuring current, electric energy and protective relaying in the electrical system with the rated frequency 50- 60Hz and highest voltage for equipment 7.2 kV /12 kV .




Main technical parameter
1. Rated voltage: 6.6 kV or 11 kV etc.
2.Rated secondary current: 5A?1A
3.Rated insulation level: 7.2/20/60 kV or 12/28/75 kV
4.Standards: IEC60044-1.2003 Part 1: Instrument transformers-Part1: Current transformers
5.Other technical parameter pls see as follows
Rated
transformation ratio(A)
Accuracy classes combination
Rated output(VA)
(ALF)
(FS)
Short-time thermal current Ith(kA/S)
Rated dynamic current Idyn(kA)
Measuring
Protective
0.2(S)
0.5
10P
10-200/5
0.2(S)/0.2(S)
0.2(S)/0.5
0.2(S)/10P
0.5/10P
0.2S/0.5/10P
0.2/0.5/10P
10
15
15
15
10
15
20
5
(10)
150I1n
375I1n
300/5
31.5
80
400/5
31.5
80
500/5
40
100
600/5
50
125
800/5
20
63
125
1000/5
80
160
1200~1500/5
80
160
1500~2000/5
100
160
2000~3150/5
130
160

Rated
transformation ratio(A)
Accuracy classes combination
Rated output(VA)
(ALF)
(FS)
Short-time thermal current Ith(kA/S)
Rated dynamic current Idyn(kA)
Measuring
Protective
0.2(S)
0.5
10P
10-200/5

0.2S//0.5/ 10P
0.5/0.5/10P
10
15
15

15

20

10


15
5
(10)
150I1n
375I1n
300/5
31.5
80
400/5
31.5
80
500/5
40
100
600/5
50
125
800/5
63
125
1000/5
80
160
1200~1500/5
80
160
1500~2000/5
100
160
2000~3150/5
130
160
Remarks: Upon request we are glad to offer transformers according to other standards or with non-standard technical specs.
Jul-23-20
 
Hebei anmei company produces various transformer accessories. The main products include high-voltage and low-voltage transfomrer bushings (DIN standard, ANSI standard, AS standard, and so on.), oil level gauge, dehydrationg breather, release valve, thermometer, valve, butterfly valve, brass gate valve, bellows, terminals,dry change accessories and so on. company can also be produced according to customer drawings. The products are exported to all world, Asia, the Middle East, South America, Europe, and so on.
470 11Kv Transformer Bushing Din 42531 Suppliers
Short on time? Let 11Kv Transformer Bushing Din 42531 sellers contact you.
Jul-15-20
 
DIN Standard Bushing for Transformer12kv 24kv 36kv 250A Electrical Porcelain Insulator
DIN(12~36kV/250~630A )
Sequence Number Code Model (Dimensions) Opening arcing distance Creep distance Shield Weight(kg)
H h2 h3 Md d1 d3 d4 E C d0 h1
1 AM.DDA.001 DIN-12/250 427 125 60 M121.75 140 74 51 146 70 78 174 300 2 5.3
2 AM.DDD.001 DIN-12/630 475 140 75 M202.5 150 88 60 174 70 92 174 310 2 8
3 AM.DFA.001 DIN-24/250 517 140 60 M11.75 145 74 51 146 100 78 249 440 3 7.2
4 AM.DFD.001 DIN-24/630 565 155 75 M202.5 160 88 60 174 100 92 249 460 3 10.4
5 AM.DGA.001 DIN-36/250 617 140 60 M121.75 155 74 51 146 200 78 349 610 4 8.3
6 AM.DGD.001 DIN-36/630 690 175 75 M202.5 180 88 60 174 200 92 354 670 4 13.5
7 AM.DGA.010 DIN-36/250 617 135 55 M121.75 190 74 51 146 200 78 354 950 6 12.5
Jul-15-20
 
DIN Standard Bushing for Transformer12kv 24kv 36kv 250A Electrical Porcelain Insulator
Feb-06-21
 
Transformer can transformer the voltage of a network into the voltage matching the system or load and fulfill power transferring and distributing.Taking the place of transformers with silicon steel core, AMDT can be widely applied in outdoor power distribution networks systems, which is magnificently energy saving and can lessen air pollution. It is especially applicable for areas with insufficient power supply and fluctuating load and where daily maintenance is hard. Since the transformer adopts a fully sealed structure, the insulating oil and the insulating medium are not polluted by the atmosphere, so it can be carried out in a humid environment, making the ideal power distribution equipment in the urban and rural distribution networks.
May-22-21
 
The transformer core is made of imported high-quality cold-rolled silicon steel sheet, which greatly reduces no-load loss and no-load current. The core is tightly bound to ensure the compactness and reduce noise.
*�  The high and low voltage windings are� made of oxygen-free copper. The low voltage winding of 500KVA and below is of double-layer cylinder structure, of 630kVA and above adopt double helix or four helix structure. High-voltage winding adopts multi-layer cylinder structure.
Dyn11 is used in the transformer connection group to reduce the influence of harmonics on the power grid and improve the quality of power supply.
*� The transformer is a fully sealed structure, with three coats of primer and one coat of finish paint applied on the inner and outer surfaces. The product is salt fog proof, moisture proof and fungus-proofing, beautiful, durable and reliable
The measured noise value is lower than the standard and maintenance free under normal operation.
Jan-29-21
 
1. Low energy consumption: The� adoption of isotropic soft magnetic material generates low magnetization power, high electrical resistivity and low eddy current consumption. The no-load loss and current of the core made of amorphous alloy are very low, only 1 / 3 of that of silicon steel sheet.
2. Strong corrosion resistance: the amorphous alloy core� is fully wrapped by resin and high temperature resistant silica glen� which� effectively prevent corrosion and falling off amorphous alloy fragments, and� provide better� protection for the core and coil.
3. Low noise. Improvement of� the structure of iron core and coil and� adoption� of special noise -reduction materials greatly reducing the operation noise.

4. Strong short-circuit resistance. This� product adopts three-phase five-column structure, and the iron core is protected by frame structure. Featured by low temperature-rise and strong heat dissipation, this� product� can work� by� 150% rated load under air cooling condition. Perfect temperature control protection system is applied� to provide reliable guarantee for safe operation of transformer
Jan-29-21
 
As the most widely used power facility, power transformers have a wide variety of types and are of great significance to energy conservation and emission reduction. The S13 fully-sealed oil-immersed power transformer is currently the main selection product for power distribution equipment, with significant energy-saving effects. At present, mainstream distribution transformers generally use S13 laminated core power transformers. It adopts a fully oil-filled sealed type, no oil conservator, and a corrugated sheet box structure. The volume of the transformer changes due to changes in temperature and load, which is completely adjusted by the corrugated oil tank. Its no-load loss is much lower than that of S9, and it is resistant to lightning impact It has strong short-circuit resistance, obvious energy-saving effect, and reduces the overall size of the transformer.

The S13 transformer is made of high-permeability oriented silicon steel sheet with a thickness of 0.27-0.30mm and a unit iron loss of 1w/kg, while the new S9 type is an ordinary silicon steel sheet with a thickness of 0.30-0.35mm and a unit iron loss of 1.20 -1.55w/kg. The S13 distribution transformers produced by our company all use 30P series high-permeability oriented silicon steel, using foil-wound coils and new insulating materials and processes. The product is resistant to high temperature, impact, and fully sealed structure design to ensure the stability of transformer oil quality It prolongs the maintenance cycle. At the same time, the integral fuel tank composed of corrugated fin radiator is produced by phosphating and multi-layer anti-rust spraying process, which has good weather resistance.
Jan-29-21
 
Product introduction
This product conforms to the national standard gb1094.1-2013 power transformer and GB / t6451-2015 three phase oil immersed power transformer technical parameters and requirements.� This product has adopted a series of major reforms in material, technology and structure, so that the electrical performance of the product can reach the advanced level of similar products. With the characteristics of high efficiency and low consumption, it can save a lot of power consumption and operation costs, and has remarkable social benefits. It is a new product promoted by the state. It is also one of the more popular products for users.
Aug-04-20
 
Transformer bushing insulators are applied as a structure, carrying on conductor through a partition such as transformer tank and insulating it, incorporating the means of attached flange to the partition for medium voltage level.
For Entire Range of Bushings Ratings from - 1 Kv to 72 Kv & - 100 Amp. to 10,000 Amp.
All Ares Insulator transformer bushing insulators are made of ceramic materials according to IEC 672. Other Transformer bushing custom-made insulators can be supplied upon customer's request and specifications.
Jan-03-20

Transformer Bushing Parts

$8
MOQ: Not Specified
Supplier From Aurangabad, Maharashtra, India
 
Transformer Lv And Hv Bushing parts used in Current, Voltage, Instrument Transformers, CT/PT/IVT Units & Tapchanger
Aug-04-20
 
Product Details
It is the insulating sleeve that leads the transformer's internal high and low voltage leads to the outside of the oil tank, which not only insulates the ground as the lead, but also plays the role of fixing the lead.
Therefore, the transformer sleeve has the following requirements:
(1) it must have specified electrical strength and sufficient mechanical strength.
(2) must have good thermal stability, and can withstand the short circuit of the instant overheating.
(3) small appearance, small quality, good sealing performance, strong universality and easy maintenance folding.
Sep-18-20
 
Standards IEC60044-1; IEC 61869-2; ANSI C57.13; NTC 2205; GB1208-2006
Rated primary current 30-1000A
Rated load 20VA
Rated frequency 50Hz or 60Hz
Rated secondary current 5A or 1A
Rated short-time thermal current 40kA, 1S
Rated continuous thermal current 120%I1n
Secondary winding power-frequency voltage 3kV, 1min
Instrument security factor FS 10
Mechanical parameters
Dimensions (WDH) (mm) 45x120x65
Weight (kg) 2.1
Operating conditions
Operating temperature -35C to +55C
Daily average temp
VERIFIED
Sep-09-22
Supplier From Visakhapatnam, Andhra Pradesh, India
 
Control transformers are mostly used for industrial applications where electromagnetic devices are used such as solenoids, contactors and relays. Also control transformers can be utilized in industrial electrical applications for regulating voltages through electrical and electronic circuits.

We make wide range of control transformers with E-I Lamination core and with various termination styles to suit for customer applications either single phase or Two phase or Three phase as per customer requirements . We provide termination with lead wires, terminal blocks, Din rails, solder points, screws, and terminal connectors. We can provide EI transformers up to 10kVA. We can provide with electrostatic shields, Thermal protector switches and circuit breakers.

Features
Insulation Class as per UL/IS (A,B,F,H)
C and L clamps are provided according to specifications.
High quality Terminal blocks are provided.
High quality XLPE leads wires used.
Low loss EI stampings used for high efficiency.
High quality hardware used.
Glass filled Nylon Bobbins used.
Flame retardant insulation tapes used inside.
High quality insulation used.
Fiber glass sleeves used for external wires.
Compact in space
Cost effective
Particularly well suited for resin cast
Less in weight
UL Approved

Standards
We follow IS11171.
Compatible to IEC61558-1
We can provide UL 5085-1 and UL 5085-2

Applications
Used in converters, inverters, instruments and power supplies.
Used in many types of machines and accessories.
Used in electronic sensing circuits.
Used in voltage stabilizers.
Used in power conditioning equipments.
Used in Rectified Modules
Jul-26-16

Resin Cast Current Transformer

$1 - $119.15
MOQ: Not Specified
Supplier From Noida, Uttar Pradesh, India
 
Resin cast current transformers are available for metering and protection application. These current transformers are mainly fabricated according to client’s specification. Ct coils are encapsulated in cast resin (polyester / epoxy). Secondary terminals are provided with either screws or studs. The main insulation between primary and secondary and earth is obtained by this epoxy resin. These transformers are of compact design with high mechanical and electrical properties. These are non-hygroscopic and hence give very good insulation properties even in given humid conditions.

General particulars

Rated voltage: 11 kv
Rated primary current: 100 a
Rated secondary current: 1a or 5a
Rate burden: 5va
Rated frequency: 50hz
Accuracy class: 0.5 or 0.5s
Temperature: as per is-2705/1992
Highest system voltage: 12kv
Insulation level: 28kvrms/75kv(p)
Stc: 13.1ka for 1 sec
Continues thermal current: 1.2 times of rated current

Core material: crgo
Copper wire material: enameled wire as per is-4800 part-4 or iec-317
Insulation class/material: epoxy resin
Secondary terminal: m5 brass bolt with nut &washer or m5 threaded bush with screw &washer
Primary terminal p1 & p2 size and material
Mounting base: ms 5mm thick zinc plated
Rountine test :as per is-2705/1992
Jul-26-16

Resin Cast Potential Transformer

$1 - $119.15
MOQ: Not Specified
Supplier From Noida, Uttar Pradesh, India
 
We manufacture highly efficient and accurate resin cast potential transformers. These resin cast potential transformers are used in ac circuits, for the purpose of measuring large voltages. Their main function is to reduce the supply voltage to a small value so that it can be easily measured with standard low range ac instruments of moderate size and capacity. There are many advantages of using resin cast potential transformers for range extension of ac meters. We also offer resin cast potential transformers of dual purpose metering & protection that are also commonly used.
Oct-30-19

33Kv Potential Transformer

$499
MOQ: Not Specified
Supplier From Delhi NCR, Delhi, India
 
These Current Transformers are manufactured in Wound Primary type and Window type construction. It is manufactured using Automatic Pressure Gelation casting and Vacuum Casting Technique. It ranges from 3.3 kV to 33 kV.
470 11Kv Transformer Bushing Din 42531 Suppliers
Short on time? Let 11Kv Transformer Bushing Din 42531 sellers contact you.