ECO-SURE (2E) Carbon Monoxide (CO) Gas Sensor Description
ECO-SURE (2E) Carbon Monoxide Sensor, 2 Electrode, long life sensor designed for residential, fire detection and ventilation control applications. UL certified.
ECO-SURE (2E) Carbon Monoxide (CO) Gas Sensor Features:
* Long Life
* Stable Performance
* UL Certified - UL2075
ECO-SURE (2E) Carbon Monoxide (CO) Gas Sensor Applications:
* Residential
* Fire Detection
* Ventilation Control
ECO-SURE (2E) Carbon Monoxide (CO) Gas Sensor Technical Specifications
* Operating Principle: 2-electrode electrochemical
* Measurement Range: 0-500 ppm CO
* Maximum Overload: 1000 ppm CO
* Sensitivity: 45 ± 15 nA/ppm
* Response Time (T90):
Cirius1 Infrared Sensor for Hydrocarbons Description and Operation
The Cirius range of sensors use the non-dispersive infrared method to detect the presence of gases. The sensors contain an infrared radiation source, a dual element infrared detector and a patented optical arrangement into which gas diffuses. The dual element infrared detector responds to changes in incident radiation and to operate he sensor the infrared source should be pulsed with a duty cycle of 50% at a frequency typically between 2Hz and 4Hz. The sensor produces outputs for active wavelengths, which are modified by the presence of target gas, and for reference wavelengths, which are not modified by the presence of target gas. These outputs consist of a small AC signal in sympathy with the source pulse that is superimposed on a DC voltage pedestal. The sensor also provides a measure of internal temperature via an embedded thermistor. The sensor requires a voltage supply to operate the infrared detector and the connections to the sensor follow the industry standard 7 pin format.
To operate the sensor it must be connected to a suitable circuit that provides the source drive and extracts the small AC signals from the DC voltage pedestal. The circuit must amplify the small AC signals, extract a value from them and treat the results to provide a linear output related to gas concentration. The temperature output from the sensor should be used to apply temperature compensation in order to achieve the full performance specification.
Cirius1 Infrared Sensor for Hydrocarbons Features
* Sensing ranges: 0-100% LFL Methane, 0-100% LFL Hydrocarbons and 0-100% volume Methane
* All metal construction
* Small internal volume
* 'Lightlocked': not affected by external illumination
* Low power
* Active and Reference signal outputs
* Embedded thermistor temperature sensor output
* Wide operating temperature range
* Fast response
* Immunity from 'poisoning'
* Fail safe operation
* Zero maintenance
* Electrically isolated housing
IMR EX610 SMART Sensor Gas Detector MAIN FUNCTION AND FEATURES
* SMART sensor module, easy for replacement and maintenance
* Intrinsically safe design
* Wide screen LCD
* High / Low alarm adjustable
* Calibration level adjustable for each calibration
* Combustible gas channel with high-concentration protection function
* Low-voltage alert
* Internal memory storage of measurements (10,000 records)
* Data upload to PC
* Audible, visual and vibration alarm
* Self-test power on
* Self-diagnostic and self-correction function
IMR EX610 SMART Sensor Gas Detector TECH SPECIFICATIONS
* Target gas: combustible gas, toxic gas, Oxygen
* Detecting method: Natural diffusion
* Response Time:
Semi-conductor, Catalytic, Thermal Conductivity t 90 < 30s
Oxygen, Carbon Monoxide, Hydrogen Sulfide t 90 < 30s
Other Sensors t 90 < 120s
* Working Conditions:
Combustible Gas: -40'C ~ 70'C
Toxic Gas: -20'C ~ 50'C
Working humidity â?¤ 95%RH non-condensating
* Power Source: Lithium battery (DC3.7V 1800mAh)
* Charging time: 4 ~ 6hours
* Continuous working time:
â?¥ 8 hours (for combustible gas and toxic gas)
â?¥ 300 hours (for toxic gas under temperature of 20'C)
* USB connectivity for data transfer
* Explosion-proof grade: Exia II CT4
* Ingress protection: IP66
* Dimensions: 108.4mm x 61mm x 36mm
* Weight: about 191g
FSM-10H-01 Pre-calibrated Module for LPG Gas
FSM-10H-01 is Pre-calibrated Module for LPG gas alarm which applies TGS2610-D00 sensor together, it features durability and stability. The module outputs PWM signal which is proportional to LPG gas concentration (The module has a memory which is stored with factory calibration data), also is capable of detecting sensor wire breakage and short. The module can operate at wide temperature from -10~70'C.
Furthermore, the unit is less sensitivity to VOCs gas, it immunes poison by silicon compounds, it suits to work at rugged environment.
FSM-10H-01 Combustible Gas Sensor Module Features
* PWM, USART digital output proportional to gas concentration
* Maintain Free
* Compact size, low cost
* Meets RoHS requirement
FSM-10H-01 Combustible Gas Sensor Module Applications
* Detect flammable gas leakage
* Flammable gas leakage Detector
* Industrial detector
FSM-10H-01 Combustible Gas Sensor Module Specification
* Gas sensor: TGS2610-D00(Semiconductor)
* Detection range: 0 ~ 4,000ppm H2
* Error: ± 300ppm
* Response time (T90): â?¤30S
* Operation temperature: -10'C ~+70'C
* Operation humidity: 20~95%RH(No condensing)
* Input voltage (VIN): 5.00.2V DC
* Power consumption: 15W
Fsm-t-04a combustible gas sensor module description
The fsm-t-04a combustible gas sensor module is a new unit which utilizes tgs6812, catalytic pellistor type gas sensor which features durability and stability. This module provides analog output voltage proportional to hydrogen gas concentration.(there is a memory in module, where factory calibration data has been store). Fsm-t-04a has conformal coatings for moisture proofing and electrical insulation purposes, and is also capable of detecting sensor wire breakage. The unit has a wide range of operating temperature from -10 to +70'c.
Furthermore, the unit can detect ch4, lpg, h2. It is less sensitivity to vocs gas, it immunes poison by silicon compounds, it suits to work at rugged environment.
Fsm-t-04a combustible gas sensor module features:
* linear analog output proportional to gas concentration
* maintenance free
* compact size
* meets rohs requirements
Fsm-t-04a combustible gas sensor module applications:
* gas leak detection in fuel cell systems
* hydrogen & combustible gas leak detectors
Fsm-t-04a combustible gas sensor module specification
* gas sensor: tgs6812 (catalyâ??tic type)
* detection range: 0 ~ 50, 000ppm ch4
* error: 3%lel
* response time (t90): 30s
* operating temperature: -10'c ~ +70'c
* operating humidity: 20~95%rh (no condensing)
* input voltage: 5.00.2v dc, 3.00.1v dc
* power consumption: 1.5w
15695 O2 M2 Oxygen Gas Sensor (O2 Sensor) Suppliers
Short on time? Let O2 M2 Oxygen Gas Sensor (O2 Sensor) sellers contact you.
FS7002 series mass flow/clog sensors can be used for open air space flow measurement or applied for clog sensing in an open space configuration. The sensor can measure air flow up to 10 m/sec with a fast response. The compact design make the installation an easy task. Examples are clog sensing in LCD projector; HVAC air flow monitoring, air fresher and fan status monitoring.
Features and Applications
- Measure open space air flow up to 10 m/sec
- Fast response < 20 msec
- Compact miniature design
- Excellent sensitivity
- Bi-direction capability
- Additional customization available
FS4003/08 series mass flow sensors are designed for general purpose flow monitor and control applications, and are made with world leading proprietary MEMS mass flow sensors and the smart electronic control system. The sensors directly measure mass flow in the designed channel with a low pressure loss. These sensors can readily be applied for electronics flow meters for anesthesia equipments, clean room air flow or nitrogen flush monitor and control, environmental equipments such as air sampler, analytical instrumentation such as GC spectrometer.
FS4008 can be configured to measure flow up to 50 SLPM. It can be applied for gas flow measurement and/or control equipments. Applications include electronic flow meter for anesthesia equipments, clean room gas flow monitor, air sampler, and gas analyzer.
Features and Applications
- Designed for 3 and 8 mm package
- Mass flow detectable from 0 ~ 2 SLPM to 0 ~ 50 SLPM
- Exchangeable connectors for easy installation
- Digital and analog output provide easy access for various communications
- Compact design ready for multiple channel assembly
- Excellent for electronic meters in anesthesia equipment
- Fast response and low power consumption
- Low pressure loss
Indoor Air Quality Sensor IAQ Gas sensor 100ppm
- Zero Power Sensor
o Sensor Circuit - < 10 uW max
- Cold operation - No Heating required
-Rugged Design- Not poisoned by
sulfides, chlorides, NH3
- Stable Response– Not affected by
humidity, CO2, N2, Ar, most saturated
hydrocarbons, hexane
- Small Size& Low Profile - 20x20x3 mm
• Sensitive - In the ppm range
• Easy to Use - Linear Response
• Long Life - 10 years expected life
• Fast Response - < 20 seconds
• ROHS Compliant
Applications:
• Bad Air Quality Detection
• Indoor Air Monitor
• Air Purifier Controls
• Weather Stations
• Internet of Things
• Smart Homes
• Early Fire Detection
• Leak Detection
• HVAC Ventilation Control
With a Freestyle Libre Sensor you can continuously measure your blood sugar for 14 days. Attaching the sensor using the sensor applicator is well described in the instructions for use. When attaching the sensor, a small, 5mm long, flexible cannula is placed under the skin (usually painless). The sensor is worn on the back of the upper arm and continuously measures your glucose levels. It is waterproof and can be worn while bathing, showering or swimming. If you set up additional optional alarms, you will be warned in good time about hypoglycemia, for example, and can therefore feel even safer - day and night.
UV Flame sensor is fire detect sensor which detecs ultraviolet rays of a flame instantly and output warning signal outside. By using emergency call equipment or adjusting the sensor connection, SKH-)$& can supervise multiple sensors at a long range.
LOX-02-S LuminOx Sealed Optical Oxygen Sensor General Description
The LuminOx Sealed Optical Oxygen Sensor Range Offers Users With Application Requirements To Only Measure Sample Gas At The Front Face Of The Sensor.
The LuminOx Sealed Optical Oxygen Sensor is developed and manufactured by SST, it is part of the LuminOx family, which is a range of factory calibrated oxygen sensors which measure ambient oxygen levels using the principle of luminescence quenching.
The LuminOx Sealed Optical Oxygen Sensor (LOX-02-S) is an extension to the standard range of LuminOx oxygen sensors. It is a similar diffusion type sensor like the original LOX-02 sensor. However, the LOX-02-S has a sealed base that is gas-tight, meaning only the face of the sensor with the protective membrane needs to be in the sample gas environment, externally leaving easy access to the pins of the sensor.
LOX-02-S LuminOx Sealed Optical Oxygen Sensor Features
* Luminescence-based optical technology, NOT electrochemical
* Contains no hazardous materials; RoHS & REACH compliant
* Connects directly to a microcontroller without any additional circuitry
* Factory calibrated
* High accuracy
* Maintenance free
LOX-02-S LuminOx Sealed Optical Oxygen Sensor Benefits
* Compact, diffusion-type housing with sealed base
* Low power, long life due to non-depleting sensing principle
* Low cost
SO-E2-960
Limiting Current Type Sensor Oxygen Sensors
When voltage is applied to a zirconia electrolyte cell, oxygen is pumped through the zirconia disc from the cathode side to the anode side because the carriers of the current flowing through the zirconia electrolyte are oxygen ions. By attaching a cap with a pinhole on the cathode side of the cell and by increasing the voltage over the cell the current shows saturation due to the rate limiting step in the transfer of oxygen to the cathode. This saturation current is called limiting current and is nearly proportional to the ambient oxygen concentration.
Below the advantages of the oxygen sensor:
measuring range 1.00 to 96.0 vol.% oxygen
High accuracy
For many types a more or less linear characteristic
Small temperature dependence of the sensor signal
Low interference with other gases
Long service life
In many cases "Single point calibration" necessary only once
Applications:
Medical
Laboratory
Food industry
Household/Gastronomy
Measuring technique
Security technology/Monitoring
(Electrical-) industry
Characteristic Data:
Measuring gas: Oxygen concentration
Measuring medium: Gaseous atmosphere
Measuring principle: Limiting current type sensor
Measuring ranges: 1.00 - 96.0 vol.% O2
Response time (t90): 2 to 25 sec. (Depends on: sensor type, gas flow, measuring chamber)
Sensor voltage / heating voltage / power consumption / heater cold resistance
Sensor voltage: 0.7 to 1.6 Volt
Heating voltage: 3.6 - 4.4 Volts
Power consumption: 1.3 to 1.8 Watts (depends on application and packaging)
Cold resistance: R( 25'C ) = 3.25 ohm ± 0.20 ohm
Warm up time: Min. 30 s
Firefighter protective Clothing: 2019 models:
Clothing outer fabric: The use of 210g arylon three anti-fabric, which not only has a permanent flame retardant, high temperature resistance, acid and alkali resistance and other properties, and its strong performance is very excellent, with high heat insulation, permanent flame retardant, high strength, anti-cutting, acid and alkali resistance, arc resistance and other characteristics, improve the overall protection performance of clothing, clothing overall main technical parameters are much higher than the industry standard and bidding technical requirements. The fire retardant performance of the firefighter\'s fire extinguishing suit: the warp and weft continuous burning time is 0s, the warp and weft damage length is less than 51mm; Breaking strength: longitude and latitude 1000N; Tear strength: longitude and latitude 120N; Moisture resistance 3, thermal stability: change rate 1.0%; Color fastness: Color resistance 4, water friction resistance 4.
Waterproof breathable heat insulation layer: aramid non-woven fabric and flame retardant PTFE film, gram weight 180g/m2. It can not only prevent the infiltration of water and other general liquid chemicals, but also discharge a large amount of hot gas generated in the body during fire rescue in time. The fabric has hydrostatic pressure & 50kPa, moisture permeability 5439g/m2/24h, oil-repellent performance 3, and thermal shrinkage 1%.
Comfort layer: The use of intermediate arylon fiber and flame retardant viscose fiber blended, gram weight 125g/m2, flame retardant performance, thermal stability and other properties are very good.
NAP-57A Catalytic Type Gas Sensor Description
NAP-57A is a newly developed catalytic type gas sensor based on conventional type NAP-56A for not only residential but also commercial or semi-industrial applications because of having highly excellent poisoning resistivity. Since its power consumption and pin positions are completely the same as NAP-55A and 56A, it is easily replaceable as it is. However, it does not possess the explosion proof by itself, then it is recommended to install it into an explosion proof chamber for actual application.
NAP-57A Catalytic Type Gas Sensor Features
* Good stability
* Excellent repeatability and detection accuracy
* Good linearity against gas concentration at wide range
* Quite excellent poisoning resistivity
* Down sizing for design flexibility of gas alarm or detector
NAP-57A Catalytic Type Gas Sensor Usage
* Gas alarm or detector of general combustible gases for all applications
* Gas densitometer
* Driving module for gas leakage detector
IMR EX610 SMART Sensor Gas Detector MAIN FUNCTION AND FEATURES
* SMART sensor module, easy for replacement and maintenance
* Intrinsically safe design
* Wide screen LCD
* High / Low alarm adjustable
* Calibration level adjustable for each calibration
* Combustible gas channel with high-concentration protection function
* Low-voltage alert
* Internal memory storage of measurements (10,000 records)
* Data upload to PC
* Audible, visual and vibration alarm
* Self-test power on
* Self-diagnostic and self-correction function
IMR EX610 SMART Sensor Gas Detector TECH SPECIFICATIONS
* Target gas: combustible gas, toxic gas, Oxygen
* Detecting method: Natural diffusion
* Response Time:
Semi-conductor, Catalytic, Thermal Conductivity t 90 < 30s
Oxygen, Carbon Monoxide, Hydrogen Sulfide t 90 < 30s
Other Sensors t 90 < 120s
* Working Conditions:
Combustible Gas: -40'C ~ 70'C
Toxic Gas: -20'C ~ 50'C
Working humidity â?¤ 95%RH non-condensating
* Power Source: Lithium battery (DC3.7V 1800mAh)
* Charging time: 4 ~ 6hours
* Continuous working time:
â?¥ 8 hours (for combustible gas and toxic gas)
â?¥ 300 hours (for toxic gas under temperature of 20'C)
* USB connectivity for data transfer
* Explosion-proof grade: Exia II CT4
* Ingress protection: IP66
* Dimensions: 108.4mm x 61mm x 36mm
* Weight: about 191g
Fsm-10h-01 pre-calibrated module for lpg gas
Fsm-10h-01 is pre-calibrated module for lpg gas alarm which applies tgs2610-d00 sensor together, it features durability and stability. The module outputs pwm signal which is proportional to lpg gas concentration (the module has a memory which is stored with factory calibration data), also is capable of detecting sensor wire breakage and short. The module can operate at wide temperature from -10~70'c.
Furthermore, the unit is less sensitivity to vocs gas, it immunes poison by silicon compounds, it suits to work at rugged environment.
Fsm-10h-01 combustible gas sensor module features
* pwm, usart digital output proportional to gas concentration
* maintain free
* compact size, low cost
* meets rohs requirement
Fsm-10h-01 combustible gas sensor module applications
* detect flammable gas leakage
* flammable gas leakage detector
* industrial detector
Fsm-10h-01 combustible gas sensor module specification
* gas sensor: tgs2610-d00(semiconductor)
* detection range: 0 ~ 4, 000ppm h2
* error: â± 300ppm
* response time (t90): â?¤30s
* operation temperature: -10'c ~+70'c
* operation humidity: 20~95%rh(no condensing)
* input voltage (vin): 5.0â±0.2v dc
* power consumption: â?¤1.5w