Shell 4 mm thk S.S. 316
Top Flange 16 MM THK RING S.S. 316
Top Lid Loose Type in two pieces 16 swg S.S. 316. or top dished as per clients requirement.
Jacket S.S. 304. 6 mm thk with spiral stiffeners
Insulation 50 mm thk glaswool cladded with with S.S 304 with 16 Swg Welded.
Conections 25 NB, bottom valve, Jacket : Steam Inlet , condensate outlet, Jacket Drain with plug, Water Inlet is provided.
Legs 40 NB, Heavy Guage S.S. pipe S.S.304. 4 nos.
Sensor PT-100 for Digital Indicator.
Jacket Pressure 3.5 Kgs.cm.sq working.
Stirrer Suitable H.P. /960 R.P.M /440V/TEFC mounted on side or from the bottom of wax vessel & Water vessel. Agitator will be propeller type
Finish Internal and all contact parts buffed to 240 grit mirror finish and external bufed to 150 grit matt finish.
B) MANUFACTURING VESSEL
Material of construction :
Shell 6 mm S.S. 316.
Bottom Hemispherical 6 mm S.S. 316
Top Dish Type 6 mm Thick S.S. 316.
Flanges 16 mm thick S.S. 316
Jacket 6 mm thk SS. 304 with spiral patten Stiffeners . cladded with 16 swg S.S 304 welded.
Gasket silicon fitted in groove.
Insulation 50 mm Thick Glasswool with 16 swg S.S. 304 cladding welded.
Legs 3 nos S.S. pipe heavy guage.
Connection Light Glass, Sight glass, Wax inlet, Water Inlet
Nozzels Vacuum Manifold with Vacuum Gauge, Vacuum Nozzle and vent Valve, product outlet , bottom full bore ball valve S.S. 316.Jacket steam inlet, condensate outlet, Drain Plug, Cooling water inlet, Cooling Water Outlet, Manifold with safety valve, Pressure gauge etc.
Bottom Clearance 500 mm from ground level to valve or as required.
Agitator Anchor type S.S. 316 . driven by suitable HP dual rpm motor coupled with gear box.
Bearing Housing Angular Roller Bearing 2 Nos Mounted on a Lantern support caldded with S.S. 304 sheet. S.S. 304 guard is provided.
Homoginizer Bottom Entry High speed Emulsifier of suitable H.P. /440V/1440 RPM/TEFC Motor.
Shaft Seal Mechanical Seal with cooling Arrangement mounted on a conical portion.
Sensor PT-100 type will be provided.
C) PRODUCT PIPE LINE :
Pipe line will cover the following :
1) Water phase vessel to Mixing vessel thru pump
2) Wax phase vessel to Mixing Vessel thru pump & conical filter
3) Mixing Vessel for re-circulation
4) Mixing vessel to Storage Vessel through lobe pump.
5) Storage vessel to hopper of filling machine through transfer pump.
All pipe are seamless & electropolished from inside and outside. Fittings are DIN standard with silicon gasket.
D) ELECTRIC CONTROL PANEL :
It shall consist of
a Main isolator
b DOL starter for Anchor drive
c DOL starter for HSE motor
d Machine light switch for main Mixing Vessel
e Electrical Digital temperature indicator for all vessel
f. Fuses for all motors
g. Ammeter for anchor and HSE motors
h. Indicating lamps for main ON & OFF with selector switch.
i. DOL starters for propeller agitators of Wax & water Phase vessels
j. DOL Starters for all the pumps
E) PUMPS:
CENTRIFUGAL PUMP
Rate : 400 Ltrs/Hr
MOC : SS 316Q
Inlet & Outlet : DIN fitting with T connection at inlet & outlet
Above pump is used to transfer wax & water to the main mixing tank.
BUMP PUMP :
Above pump is used to recirculate final mixed cream for intense mixing & to transfer finished cream from Mixing vessel to storage vessel. Other details are as below.
1) Type : Twin BUMP
2) Design : Sanitary
3) Drive : suitable HP, 200 RPM gearbox & motor
4) Seal : Teflon bush
5) Mounting : Trolley mounted , MOC ? SS304Q
6) Inlet & outlet : DIN fittings / triclover at inlet & outlet.
7) MOC : SS 316Q for contact parts
TRANSFER PUMP ? RECIPROCATING TYPE, POSITIVE DISPLACEMENT & METERING TYPE
Above pump is used to transfer CREAM/OINTMENT from storage vessel to hopper of filling machine.
a) Type : Reciprocating Plunger type
b) Capacity : 1000 LtR./Hr
c) Drive : suitable HP, 1440 RPM
d) Head : 2.5 Mtr.
e) Mounting : Trolley mounted , MOC ? SS304Q
The above pump doses metered quantity of cream into the hopper of filling machine which suits filling rate of filling machine. There is control feed back system between Filling machine & pump .
VACUUM PUMP :
Above pump is suitable HP & capacity depending on the capacity of the ointment plant vessel . watering / oilring type with silencer & non return valve.
F) STORAGE TANK:
The vessel shall be in SS 316Q having cylindrical conical bottom. The vessel will be provided with 40mm ball valve. Shell portion will be flanged from top & bolted to top dish with gasket in bet-ween. All joints are fusion free argon arc welded & inside mirror finished.
The vessel will be supported by 4 nos. cladded ?C? class 3? pipe and to maintain 450mm ground clearance. Vessel has 50mm inlet nozzle for finished product entry & vent.
G) WORKING PLATFORM :
This platform will cover both tanks & with AL dimpled plate and SS counter sunk screw. SS 304 Q railing on either side. There is provision of steps on either side.
These totally exhaust system are designed for 100% exhaust of HEPA filtered air outside the room through a exhaust duct protects user product as well as the laboratory. Fitted with Microprocessor LCD display controller with facility to display air velocity across work table.
Features
100 % air exhaust
Negative pressure air surrounding all biological contaminated parts
Class II, Type B2 cabinets are total exhaust cabinets, widely used in toxicology laboratories and similar applications where chemical effluent is present and clean air is essential.
There is no recirculation within the work area.
Room air enters through a blower/motor in the top of the cabinet and passes through a HEPA supply filter into the work area as the vertical unidirectional airflow.
Descending air is pulled through the base of the cabinet through the perforated front and rear grilles.
Simultaneously, air entering through the perforated front opening is pulled through the grille and exhausted immediately,
100% of the air is pulled into the facility exhaust system for appropriate treatment.
Type B2 cabinet is hard-connected to an exhaust system.
Negative pressure surrounds the work area with double-wall plenums for protection.
Air drawn through pre-filter is made to pass through highly effective HEPA (High-Efficiency Particular Air) filters. The prefilter fitted extends the life of the HEPA filter drastically. Fitted with HEPA Filter made from water-resistant, fire retardant, imported microfine glass fiber media; conforms to EU - 14 Grade, with an efficiency rating better than 99.999% for 0.3 �¼. These filters are designed to accommodate higher air flow volume.
Prefilter is made from Non-Woven Synthetic with HDPE mesh and Al expanded mesh on the air leaving side; conforms to EU-4 /G-4 Grade, with the efficiency of down to 10 microns. These filters can be cleaned by compressed air & also washable.
Mounted on heavy tubular stand with lockable castors.
Aerodynamic airflow grills maintain safety and prevents blockage.
U.V and fluorescent interlock available
Ergonomic and comfortable sloped front window for comfortable head and elbow rest position, thus reducing fatigue
Sash is counterbalanced for smooth and lightweight operation with a standard opening for easier access to the work zone and enhanced user safety.
CLASS-II design ensures PERSONNEL, PRODUCT and ENVIRONMENT PROTECTION.
Class II Biosafety Cabinet Protection
Personnel protection from harmful agents used inside the biosafety cabinet.
Product protection to avoid contamination of the works, experiment or process from outside contaminants.
Environmental protection from contaminants contained within the biosafety cabinet.
Class II Biosafety Cabinet Key Features
A front access opening with carefully maintained inward airflow.
HEPA-filtered, vertical, unidirectional airflow within the work area.
HEPA-filtered exhaust air to the room or exhaust to a facility exhaust system.
Class II Biosafety Key Applications
Typically used for biosafety levels 1 through 3 for low to moderate risk biological agents.
The type B2 total exhaust cabinets are widely used in toxicology laboratories and similar applications where chemical effluent is present and clean air is essential.
All types of Class II cabinets may be used in biosafety level 4 laboratories when workers utilize positive pressure suits. However, for level 4 Class III cabinets are recommended.
Upper & front cover
Removable upper and front cover simplifies filter, blower and front control panel replacements and maintenance easier.
Material of construction
Working Table is made up of Stainless Steel (SS-304). External Cabinet is fabricated of electrogalvanized powder coated OR Stainless Steel (SS-304) (as ordered).
Front Window/Sash
Front Sash consists of a thick plexi-glass or toughened transparent glass (Option) for a clear inside view. In addition it serves optimum resistance and protection from harmful UV rays, protection user from exposure to harmful Ultraviolet radiation.
Drain Trough with Valve
The trough at base is easy to clean and for offloading liquid spillage if any.
Decontamination by UV Lamp
UV Lamp to produce UV rays of 253.7 nanometers and fluorescent lamp are interlocked and the motor blower is turned off/on as and when the front sash is closed/opened. UV lamps function through a timer (Option) to control the decontamination cycle and maximize UV lamp life. The UV lamp shuts off once the desired set time of decontamination is over and switches the fluorescent lamp to ON position.
Splash Proof Electric Supply Socket
Splash proof sockets is provided for optimum convenience of using small electrical devices inside the cabinet.
Front Airflow Intake Grid
Aerodynamically designed front airflow intake grid eliminates potential turbulence and contamination.
Floor Stand and Castor Wheels
Floor Stand is made up of heavy-duty tubular pipe duly powder coated and fitted with durable castor wheels for rotation and total brake system on front wheels.
Controller
These models are provided with Microprocessor Based Digital Controller with LCD display and air velocity sensor to display the air velocity across the work table
These totally exhaust system are designed for 100% exhaust of HEPA filtered air outside the room through a exhaust duct protects user product as well as the laboratory. Fitted with Microprocessor LCD display controller with facility to display air velocity across work table.
Features
100 % air exhaust
Negative pressure air surrounding all biological contaminated parts
Class II, Type B2 cabinets are total exhaust cabinets, widely used in toxicology laboratories and similar applications where chemical effluent is present and clean air is essential.
There is no recirculation within the work area.
Room air enters through a blower/motor in the top of the cabinet and passes through a HEPA supply filter into the work area as the vertical unidirectional airflow.
Descending air is pulled through the base of the cabinet through the perforated front and rear grilles.
Simultaneously, air entering through the perforated front opening is pulled through the grille and exhausted immediately,
100% of the air is pulled into the facility exhaust system for appropriate treatment.
Type B2 cabinet is hard-connected to an exhaust system.
Negative pressure surrounds the work area with double-wall plenums for protection.
Air drawn through pre-filter is made to pass through highly effective HEPA (High-Efficiency Particular Air) filters. The prefilter fitted extends the life of the HEPA filter drastically. Fitted with HEPA Filter made from water-resistant, fire retardant, imported microfine glass fiber media; conforms to EU - 14 Grade, with an efficiency rating better than 99.999% for 0.3 �¼. These filters are designed to accommodate higher air flow volume.
Prefilter is made from Non-Woven Synthetic with HDPE mesh and Al expanded mesh on the air leaving side; conforms to EU-4 /G-4 Grade, with the efficiency of down to 10 microns. These filters can be cleaned by compressed air & also washable.
Mounted on heavy tubular stand with lockable castors.
Aerodynamic airflow grills maintain safety and prevents blockage.
U.V and fluorescent interlock available
Ergonomic and comfortable sloped front window for comfortable head and elbow rest position, thus reducing fatigue
Sash is counterbalanced for smooth and lightweight operation with a standard opening for easier access to the work zone and enhanced user safety.
CLASS-II design ensures PERSONNEL, PRODUCT and ENVIRONMENT PROTECTION.
Class II Biosafety Cabinet Protection
Personnel protection from harmful agents used inside the biosafety cabinet.
Product protection to avoid contamination of the works, experiment or process from outside contaminants.
Environmental protection from contaminants contained within the biosafety cabinet.
Class II Biosafety Cabinet Key Features
A front access opening with carefully maintained inward airflow.
HEPA-filtered, vertical, unidirectional airflow within the work area.
HEPA-filtered exhaust air to the room or exhaust to a facility exhaust system.
Class II Biosafety Key Applications
Typically used for biosafety levels 1 through 3 for low to moderate risk biological agents.
The type B2 total exhaust cabinets are widely used in toxicology laboratories and similar applications where chemical effluent is present and clean air is essential.
All types of Class II cabinets may be used in biosafety level 4 laboratories when workers utilize positive pressure suits. However, for level 4 Class III cabinets are recommended.
Upper & front cover
Removable upper and front cover simplifies filter, blower and front control panel replacements and maintenance easier.
Material of construction
Working Table is made up of Stainless Steel (SS-304). External Cabinet is fabricated of electrogalvanized powder coated OR Stainless Steel (SS-304) (as ordered).
Front Window/Sash
Front Sash consists of a thick plexi-glass or toughened transparent glass (Option) for a clear inside view. In addition it serves optimum resistance and protection from harmful UV rays, protection user from exposure to harmful Ultraviolet radiation.
Drain Trough with Valve
The trough at base is easy to clean and for offloading liquid spillage if any.
Decontamination by UV Lamp
UV Lamp to produce UV rays of 253.7 nanometers and fluorescent lamp are interlocked and the motor blower is turned off/on as and when the front sash is closed/opened. UV lamps function through a timer (Option) to control the decontamination cycle and maximize UV lamp life. The UV lamp shuts off once the desired set time of decontamination is over and switches the fluorescent lamp to ON position.
Splash Proof Electric Supply Socket
Splash proof sockets is provided for optimum convenience of using small electrical devices inside the cabinet.
Front Airflow Intake Grid
Aerodynamically designed front airflow intake grid eliminates potential turbulence and contamination.
Floor Stand and Castor Wheels
Floor Stand is made up of heavy-duty tubular pipe duly powder coated and fitted with durable castor wheels for rotation and total brake system on front wheels.
Controller
These models are provided with Microprocessor Based Digital Controller with LCD display and air velocity sensor to display the air velocity across the work table
Bio safety Cabinet Class II Type A 2,Recirculates 70% of HEPA filtered air and rest 30% air exhausted through optional exhaust system. Fitted with Microprocessor LCD display controller with facility to display air velocity across work table.
Features
30% air exhaust
70% air recirculation
HEPA OR ULPA -filtered exhaust air in Type A2 cabinet may be recirculated into the room or exhausted to the outdoors through a canopy exhaust connection.
HEPA OR ULPA -filtered downflow air is a portion of mixed downflow and inflow air from a common plenum.
Negative Pressure air surrounding all biological contaminated ducts and plenums.
Negative pressure surrounds the work area with double wall plenums for protection.
Air drawn through pre-filter is made to pass through highly effective HEPA OR ULPA (High Efficiency Particular Air) filters. The prefilter fitted extends the life of HEPA OR ULPA filter drastically. Fitted with HEPA OR ULPA Filter made from water resistant, fire retardant, imported micro fine glass fibre media; conforms to EU â?? 14 Grade, with an efficiency rating better than 99.999% for 0.3 �¼.These filters are designed to accommodate higher air flow volume.
Prefilter are made from Non-Woven Synthetic with HDPE mesh and Al expanded mesh on air leaving side; conforms to EU â?? 4 / G-4 Grade, with an efficiency of down to 10 micron. These filters can be cleaned by compressed air & also washable.
Mounted on heavy tubular stand with lockable castors.
Aerodynamic airflow grills maintain safety and prevent blockage
U.V and fluorescent interlock available
Ergonomic and comfortable 10 degrees sloped front window for comfortable head and elbow rest position, thus reducing fatigue.
The sash is counterbalanced for smooth and lightweight operation with the standard opening of 200mm �±10 mm for easier access to work zone and enhanced user safety.
Class II Biosafety Cabinet Protection
High velocity air forced through HEPA OR ULPA filters.
Filtered air is thrown in the chamber through jet nozzles with a high velocity which in turn disperse particulate matter on all surface.
The lower portion of the Air showers suck the contaminated air and allow it to pass to blower supply plenum through pre-filter installed at the base.
This process is a continuous process in which air is continuously filtered and recirculated inside the chamber without any exchange with the external environment.
Upper & front cover
Removable upper and front cover simplifies filter, blower and front control panel replacements and maintenance easier.
Material of construction
Working Table is made up of Stainless Steel (SS-304). External Cabinet is fabricated of CRC sheet duly powder coated
Front Window/Sash
Front Sash consists of a toughened transparent glass for a clear inside view. In addition it serves optimum resistance and protection from harmful UV rays, protects user from exposure to harmful Ultraviolet radiation.
Drain Trough with Valve
The trough at base is easy to clean and for offloading liquid spillage if any.
Decontamination by UV Lamp
UV Lamp to produce UV rays of 253.7 nanometers and fluorescent lamp are interlocked and motor blower are turned off/on as and when front sash is closed/opened. UV lamps functions through a timer (Option) to control the decontamination cycle and maximize UV lamp life. The UV lamp shuts off once the desired set time of decontamination is over and switches the fluorescent lamp to ON position.
Splash Proof Electric Supply Socket
Splash proof sockets is provided for optimum convenience of using small electrical devices inside the cabinet.
Front Airflow Intake Grid
Aerodynamically designed front airflow intake grid eliminates potential turbulence and contamination.
Floor Stand and Castor Wheels
Floor Stand is made up of heavy duty tubular pipe duly powder coated and fitted with durable castor wheels for rotation and total brake system on front wheels.
Controller
These models are provided with Microprocessor Based Digital Controller with LCD display and air velocity sensor to display the air velocity across the work table.
Bio safety Cabinet Class II Type A 2 GMP model,Recirculates 70% of HEPA filtered air and rest 30% air exhausted through optional exhaust system. Fitted with Microprocessor LCD display controller with facility to display air velocity across work table.
Features
30% air exhaust
70% air recirculation
HEPA OR ULPA -filtered exhaust air in Type A2 cabinet may be recirculated into the room or exhausted to the outdoors through a canopy exhaust connection.
HEPA OR ULPA -filtered downflow air is a portion of mixed downflow and inflow air from a common plenum.
Negative Pressure air surrounding all biological contaminated ducts and plenums.
Negative pressure surrounds the work area with double wall plenums for protection.
Air drawn through pre-filter is made to pass through highly effective HEPA OR ULPA (High Efficiency Particular Air) filters. The prefilter fitted extends the life of HEPA OR ULPA filter drastically. Fitted with HEPA OR ULPA Filter made from water resistant, fire retardant, imported micro fine glass fibre media; conforms to EU â?? 14 Grade, with an efficiency rating better than 99.999% for 0.3 �¼.These filters are designed to accommodate higher air flow volume.
Prefilter are made from Non-Woven Synthetic with HDPE mesh and Al expanded mesh on air leaving side; conforms to EU â?? 4 / G-4 Grade, with an efficiency of down to 10 micron. These filters can be cleaned by compressed air & also washable.
Mounted on heavy tubular stand with lockable castors.
Aerodynamic airflow grills maintain safety and prevent blockage
U.V and fluorescent interlock available
Ergonomic and comfortable 10 degrees sloped front window for comfortable head and elbow rest position, thus reducing fatigue.
The sash is counterbalanced for smooth and lightweight operation with the standard opening of 200mm �±10 mm for easier access to work zone and enhanced user safety.
Class II Biosafety Cabinet Protection
High velocity air forced through HEPA OR ULPA filters.
Filtered air is thrown in the chamber through jet nozzles with a high velocity which in turn disperse particulate matter on all surface.
The lower portion of the Air showers suck the contaminated air and allow it to pass to blower supply plenum through pre-filter installed at the base.
This process is a continuous process in which air is continuously filtered and recirculated inside the chamber without any exchange with the external environment.
Upper & front cover
Removable upper and front cover simplifies filter, blower and front control panel replacements and maintenance easier.
Material of construction
Working Table is made up of Stainless Steel (SS-304). External Cabinet is fabricated of SS 304
Front Window/Sash
Front Sash consists of a toughened transparent glass for a clear inside view. In addition it serves optimum resistance and protection from harmful UV rays, protects user from exposure to harmful Ultraviolet radiation.
Drain Trough with Valve
The trough at base is easy to clean and for offloading liquid spillage if any.
Decontamination by UV Lamp
UV Lamp to produce UV rays of 253.7 nanometers and fluorescent lamp are interlocked and motor blower are turned off/on as and when front sash is closed/opened. UV lamps functions through a timer (Option) to control the decontamination cycle and maximize UV lamp life. The UV lamp shuts off once the desired set time of decontamination is over and switches the fluorescent lamp to ON position.
Splash Proof Electric Supply Socket
Splash proof sockets is provided for optimum convenience of using small electrical devices inside the cabinet.
Front Airflow Intake Grid
Aerodynamically designed front airflow intake grid eliminates potential turbulence and contamination.
Floor Stand and Castor Wheels
Floor Stand is made up of heavy duty tubular pipe duly powder coated and fitted with durable castor wheels for rotation and total brake system on front wheels.
Controller
These models are provided with Microprocessor Based Digital Controller with LCD display and air velocity sensor to display the air velocity across the work table.
Integral Dental Unit(DTK-898)
Water tubes and suction tubes are from USA,air and water system is control by Italy valves
Suspension Type design, optimal comfort when adjust the chair position
Spittoon and assistant system, which are positioned by intelligent remote control, makes it much simpler for patient to spit and effective for doctor to operate equipment
Intelligent LCD display screen and touch control panel with 12 position memorize
Aluminum base for the backrest and strong steel base for the chair, strong enough for heavy patients
Denmark "Linak" Electric Motor
LED Sensor Operation Lamp
STANDRAD CONFIGURATION
Dentist stool DTK-010, same color with dental chair: 1 set
Imported(4-hole) high-speed air turbine handpiece tie-in 2 sets
Imported(4-hole) low-speed air turbine handpiece tie-in: 1 set
Three-way syringe(cold and hot): 1 set each
Built-in clean and disinfection system for water pipe in machine
X-film viewer(DC/Low voltage)
Super sensor operation lamp 1 set
Water supply control system for cup filler and bowl rinse 1 set
Handpieces water purified and air purified system 1 set
Back position with negative angle compensation function
Foot controller 1 set
Dental stool 1 set
SPECIFICATIONS:
Power supply voltage------------AC220V,50Hz
Air source presssure------------ï¼?0.55Mpa
Water source pressure-----------0.2Mpa-0.4Mpa
Optional:
Scaler
Camera and monitor
NSK hand piece
Air Compressor
Central suction machine
Intra Oral Camera
Wesupply CNC machines highqualitywithCE and FDA Certificate ,Website:http://www.sdbk-cnc.com,3 YearsWarranty .Wedevotedourselvestocnc machinesmanyyears,coveringmostofEuropeandtheAmericasmarket.Weareexpectingbecomeyourlong-termpartnerinChinaApplications of 4X8 feet 1325 CNC router Woodworking industry: three-dimensional wave board processing, furniture like solid wood door, kitchen cabinets, wardrobe cabinets, tables, beds, computer desk and cylinders like
table legs, sofa legs, wooden craft, paint door, screen, craft fan window processing, shoe polisher, game cabinets and panel, mahjong table, auxiliary processing.Advertising industry: advertising sign, logo making, acrylic cutting, plastic molding, a variety of materials advertising the production of decorative product.Mold industry: engraving wood, foam, EPS, copper, aluminum mold, as well as artificial marble, sand, plastic sheeting, PVC pipe, wood and other non-metallic
mold.Other industry: a variety of large-scale relief sculpture, shadow carving, widely used in the craft industry.Features of 4X8 feet 1325 CNC router :11300*2500*200mm effective work area.23. 0KW water cooling spindle, 24000rpm33.7kw Fuling inverter(China top quality)4NK105 DSP controller.5Taiwan HIWIN #20 square linear guide.6Helical rack transmission for X, Y axis, powerful and stable.7Taiwan TBI ballscrew transmission for Z axis, most accurate precision.8Vacuum and T-slot working table9Water mist cooling sprayer(for metal working).10Manual lubrication system.11Tool sensor calibration12Japan OMRON limit switch.13The best cable, highly flexible, fire resistant.4X8 feet 1325 CNC router optional items: 1Rotary device(4th axis).22. 200mm/300mm/400mm/500mm for Z axis.33KW water-cooling spindle.4NC studio/DSP control system5Stepper motor(Japan Yaskawa servo, Taiwan DELTA servo for choose)6Automatic tool changer(ATC).7Dust collector.8Vacuum pump.ModelBKM1325Working Area1300x2500x200mmTraveling Positioning Accuracy±0.03/300mmRepositioning Accuracy±0.03mmTable SurfaceVacuum and T-slot working tableFrameWelded StructureX, Y StructureHelical rack, Taiwan HIWIN Rail Linear BearingsZ StructureTaiwan HIWIN Rail Linear Bearings and Ball ScrewMax. Power Consumption(Without Spindle) 3.2KWMax. Rapid Travel Rate33000mm/minMax. Working Speed25000mm/minSpindle Power3KW water cooling spindle (Italy HSD spindle for option)Spindle Speed0-24000RPMDrive MotorsYAKO or Lead shineWorking VoltageAC380V/50/60Hz,3PH (Option: 220V)Command LanguageG CodeOperating SystemDSP (Options: Ncstudio/Mach3)Computer InterfaceUSBColletER20X,Y Resolution
PX LASER CUTTING MACHINES are advanced tools engineered for precision cutting of pipes with varying diameters and shapes. Utilizing laser technology, these machines deliver clean, accurate cuts across a diverse array of materials, making them indispensable in industrial and manufacturing settings. Designed to accommodate pipe diameters ranging from 20 mm to 220 mm, these machines feature a high-powered laser beam, a precision cutting head, and a computerized control system for precise operations. Whether deployed as standalone units or integrated with existing laser cutting systems, pipe cutting laser machines offer exceptional precision, speed, and efficiency, making them ideal for diverse industrial and manufacturing applications.
Number of Chuck:
Standard: 2
Option: -
Cutting Head: Raytools (As per Power Source)
Bevel Cutting: -
Loading: Manual
Loading Options: -
Tube Length: 6000 mm
Loading Weight: Up to 20 kg/m
Laser Power: 1000, 2000 W
Accuracy:
Positioning X/Y Axis: ± 0.05 mm
Re-Positioning X/Y Axis: ± 0.03 mm
Round: 010 mm - 0160 mm
Square: 15/15 mm - 100/100 mm
Diagonal: within 160 mm
Model: PX 2260/2290
Chuck Size: 220 mm
Number of Chuck:
Standard: 2
Option: 3
Cutting Head: Raytools (As per Power Source)
Bevel Cutting: Optional with 3 Chuck
Loading: Manual
Loading Options: Optional Semi or Auto Load
Tube Length: 6000 mm / 9000 mm
Loading Weight: Up to 30 kg/m
Laser Power: 1500, 3000 W
Accuracy:
Positioning X/Y Axis: ± 0.05 mm
Re-Positioning X/Y Axis: ± 0.03 mm
Round: 015 mm - 0220 mm
Square: 15/15 mm - 145/145 mm
Diagonal: within 220 mm
Model: PX 3260/3290
Chuck Size: 320 mm
Number of Chuck:
Standard: 2
Option: 3/4
Cutting Head: Raytools (As per Power Source)
Bevel Cutting: Optional with 3 & 4 Chuck
Loading: Manual
Loading Options: Optional Semi or Auto Load
Tube Length: 6000 mm / 9000 mm
Loading Weight: Up to 40 kg/m
Laser Power: 1500, 6000 W
Accuracy:
Positioning X/Y Axis: ± 0.05 mm
Re-Positioning X/Y Axis: ± 0.03 mm
Round: 020 mm - 0320 mm
Square: 15/15 mm - 210/210 mm
Diagonal: within 320 mm
Plastic housing made of PP, POM or PA, rust free for water flow.
Vertical or horizontal installation, easy to set up for different applications.
Sensitive start up volume setting and accurate to measure volume.
Features of plastic water flow switch
Multiple mounting options: can be mounted vertically or horizontally.
Different connecting options: barbed connector or threaded connector with different sizes.
Wide range of application with working temperature up to 100â??.
For more information about pvc pipe flow switch and buy position sensor, please feel free to contact us!