Voltage Monitoring Series SM 501
86
Cat. No.
Parameters
MG53BH MG53BF MG63BH MG63BF
415 VAC (3 Phase, 3 Wire) 220 VAC (3 Phase, 3 Wire)
Frequency
Power Consumption (Max.) 10 VA 5 VA
50/60 Hz
Supply Voltage ( )
105% to 125% (of )
55% to 95% (of )
Trip
Settings
Under Voltage
Over Voltage
Hysterisis 7 V (�± 2 V) of Trip Voltage
Phase Loss
Phase Sequence
Phase Asymmetry
Yes
Yes
LED Indication
Storage Temperature
Operating Temperature
Separate indications for Power ON, UV and OV; ON: Phase Reverse; BLINK: Phase Asymmetry
O -15 C To + 55 C
O O -25 C To + 70 C
O
Utilization Category
AC - 15
DC - 13
Rated Voltage (Ue): 120/240 V, Rated Current (Ie): 3.0/1.5 A
Rated Voltage (Ue): 24/125/250 V, Rated Current (Ie): 2.0/0.22/0.1 A
Output
Contact Rating
Electrical Life
Mechanical Life
Relay Output
5A @ 250 VAC / 28 VDC (Resistive)
5 1X10
6 3X10
2 C/O
Enclosure
Dimension (W x H x D) (in mm)
Weight (unpacked)
Mounting
Certification
Flame Retardant UL 94-V0
36 X 90 X 60
120 g
Base / DIN rail
Degree of Protection IP 20 for Terminals, IP 40 for Enclosure
ORDERING INFORMATION
Note: 1) Voltage Setting Accuracy: �± 5 % of Full Scale; Time Setting Accuracy: �± 10 % of Full Scale
2) In the event of Phase Sequence or Phase Loss, OFF Delay is 100 ms
Humidity (Non Condensing) 95% (Rh)
0.5 to 15 s (Selectable)
5 s
0.5 to 15 s (Selectable)
5 s 0.5 to 15 s (Selectable)
5 s
0.5 to 15 s (Selectable)
Time 5 s
Delay
ON Delay
Trip Time (OFF Delay)
10% (of )
Cat. No. Description
MG53BH 415 VAC, & Single Phasing Preventor (SPP) with Selectable ON Delay (0.5 to 15 sec), 2 C/O
MG53BF 415 VAC, UV / OV & SPP with Selectable OFF Delay (0.5 to 15 sec), 2 C/O
MG63BH 220 VAC, with Selectable ON Delay (0.5 to 15 sec), 2 C/O
MG63BF 220 VAC, with Selectable OFF Delay (0.5 to 15 sec), 2 C/O
UV / OV
UV / OV & SPP
UV / OV & SPP
EMI / EMC
Harmonic Current Emissions IEC 61000-3-2 Ed. 3.2 (2009-04) Class A
ESD IEC 61000-4-2 Ed. 2.0 (2008-12) Level III
Radiated Susceptibility IEC 61000-4-3 Ed. 3.2 (2010-04) Level III
Electrical Fast Transients IEC 61000-4-4 Ed. 3.0 (2012-04) Level IV
Surges IEC 61000-4-5 Ed. 2.0 (2005-11) Level IV
Conducted Susceptibility IEC 61000-4-6 Ed. 3.0 (2008-10) Level III
Voltage Dips & Interruptions (AC) IEC 61000-4-11 Ed. 2.0 (2004-03) All 7 Levels
Conducted Emission CISPR 14-1 Ed. 5.2 (2011-11) Class A
Radiated Emission CISPR 14-1 Ed. 5.2 (2011-11) Class B
Environmental
Cold Heat IEC 60068-2-1 Ed. 6.0 (2007-03)
Dry Heat IEC 60068-2-2 Ed. 5.0 (2007-07)
Vibration IEC 60068-2-6 Ed. 7.0 (2007-12) 5g
Repetitive Shock IEC 60068-2-27 Ed. 4.0 (2008-02) 40g, 6ms
Non-Repetitive Shock IEC 60068-2-27 Ed. 4.0 (2008-02) 30g, 15ms
RoHS Compliant
LED Indications for Power and Fault conditions
Voltage Sensing Principle
2 C/O Configuration
Protects against Phase Loss, Phase Reversal & Phase Asymmetry
Can be configured for 3 Phase 4 Wire or 1 Phase system
Selectable Over Voltage / Under Voltage Trip level
Selectable Time Delay
LED Indications for Power and Fault conditions
Voltage Sensing principle
1 C/O or 2 C/O Configuration
Voltage Monitoring Series SM 500
83
Cat. No.
Parameters
240 VAC (1 Phase & 3 Phase, 4 Wire)
Frequency
Power Consumption (Max.) 4 VA
50/60 Hz
Supply Voltage ( )
105% to 125% (of )
55% to 95% (of )
LED Indication
Operating Temperature
Storage Temperature
Separate indications for Power ON, UV and OV
O O -15 C To + 55 C
O O -25 C To + 70 C
Utilization Category
AC - 15
DC - 13
Rated Voltage (Ue): 120/240 V, Rated Current (Ie): 3.0/1.5 A
Rated Voltage (Ue): 24/125/250 V, Rated Current (Ie): 2.0/0.22/0.1 A
Trip
Settings
Under Voltage
Phase Loss
Phase Sequence
Phase Asymmetry
Over Voltage
0.5 to 15 s (Selectable)
5 s 0.5 to 15 s (Selectable)
5 s
5 s
0.5 s to 15 min (Selectable)
Time
Delay
ON Delay
Trip Time (OFF Delay)
Output
Contact Rating
Electrical Life
Mechanical Life
Relay Output
5A @ 250 VAC / 28 VDC (Resistive)
5 1X10
6 3X10
1 C/O
Enclosure
Dimension (W x H x D) (in mm)
Weight (unpacked) Approx.
Mounting
Certification
Flame Retardant UL 94-V0
36 X 90 X 60
120 g
Base / DIN rail
Degree of Protection IP 20 for Terminals, IP 40 for Enclosure
ORDERING INFORMATION
Note: 1) Voltage setting is with respect to Neutral. Voltage Setting Accuracy: �± 5 % of Full Scale; Time Setting Accuracy: �± 10 % of Full Scale
RoHS Compliant
Humidity (Non Condensing) 95% (Rh)
EMI / EMC
Harmonic Current Emissions IEC 61000-3-2 Ed. 3.2 (2009-04) Class A
ESD IEC 61000-4-2 Ed. 2.0 (2008-12) Level II
Radiated Susceptibility IEC 61000-4-3 Ed. 3.2 (2010-04) Level III
Electrical Fast Transients IEC 61000-4-4 Ed. 3.0 (2012-04) Level IV
Surges IEC 61000-4-5 Ed. 2.0 (2005-11) Level IV
Conducted Susceptibility IEC 61000-4-6 Ed. 3.0 (2008-10) Level III
Voltage Dips & Interruptions (AC) IEC 61000-4-11 Ed. 2.0 (2004-03) All 7 Levels
Conducted Emission CISPR 14-1 Ed. 5.2 (2011-11) Class A
Radiated Emission CISPR 14-1 Ed. 5.2 (2011-11) Class A
Environmental
Cold Heat IEC 60068-2-1 Ed. 6.0 (2007-03)
Dry Heat IEC 60068-2-2 Ed. 5.0 (2007-07)
Vibration IEC 60068-2-6 Ed. 7.0 (2007-12) 5g
Repetitive Shock IEC 60068-2-27 Ed. 4.0 (2008-02) 40g, 6ms
Non-Repetitive Shock IEC 60068-2-27 Ed. 4.0 (2008-02) 30g, 15ms
Cat. No. Description
MD71BH 240 VAC, UV / OV with Selectable ON Delay (0.5 to 15 sec), 1 C/O
MD71BF 240 VAC, UV / OV with Selectable OFF Delay (0.5 to 15 sec), 1 C/O
MD71B9 240 VAC, UV / OV with Selectable ON Delay (0.5 s to 15 min), 1 C/O
SWITCH OUTPUT MODULE 1756-0B16E
Deyang YOYIK skill is strong, the production of strict accordance with national standards. With the power station forging, mining metallurgy, rolling, cement and spare parts spare parts, metallurgy, rolling and other products improve the production and operation system. For hundreds of water technology change, hydropower, thermal power plant overhaul supply of high-quality equipment selection, equipment commissioning, construction plans, spare parts, after-sales service, such as through-train service. The company to undertake hydropower stations, thermal power plant unit capacity transformation, technical transformation and overhaul projects. Look forward to the major manufacturers to inquire.
General Information
Product ID: 3BSE045584R1
Medium Description: AO845A Analog Output Module, Redundant or single, 8 channels, HART
Technical Information: Supersedes 3BSE023676R1
Product Type: I/O Module
Country of Origin: India
Customs Tariff Number: 85389091
Length: 102 mm
Height: 119 mm
Width: 45 mm
Weight: 0.3 kg
General Information
Product ID: 3BSE052605R1
Medium Description: AO815 Analog Output Module, 8 channels with HART
Product Type: I/O Module
Country of Origin: India
Customs Tariff Number: 85389091
Length: 102 mm
Height: 119 mm
Width: 45 mm
Weight: 0.3 kg
General Information
Product ID: 3BSE038415R1
Medium Description: AO810V2 Analog Output Module, 8 channels, 0(4)...20mA
Technical Information: Supersedes 3BSE008522R1/3BSE038415Z1
Product Type: I/O Module
Country of Origin: Estonia /India
Customs Tariff Number: 85389091
Length: 102 mm
Height: 119 mm
Width: 45 mm
Weight: 0.19 kg
Description
The Trusted TMR Analogue Output module interfaces to 40 field devices. Triplicated diagnostic tests are performed throughout the module including measurements for current, and voltage on each portion of the voted output channel. Tests are also performed for stuck on and stuck off failures. Fault tolerance is achieved through a Triple Modular Redundant (TMR) architecture within the module for each of the 40 output channels.
Automatic line-monitoring of the field device is provided. This feature enables the module to detect both open and short circuit failures in field wiring and load devices.
The module provides on-board Sequence of Events (SOE) reporting with a resolution of 1ms. An output change of state triggers an SOE entry. Output states are automatically determined by voltage and current measurements on board the module.
Features
40 Triple Modular Redundant (TMR) output channels per module.
Comprehensive, automatic diagnostics and self-test.
Automatic line monitoring per point to detect open circuit and short circuit field wiring and load faults.
2500V dc optical isolation barrier.
On-board Sequence of Events (SOE) reporting with 1ms resolution. Module can be hot-replaced on-line using dedicated Companion (adjacent) Slot or SmartSlot (one spare slot for many modules) configurations.
Front panel output status LEDs for each point indicate output status and field wiring faults
Front panel module status LEDs indicate module health and operational mode (Active, Standby, Educated)
TUV Certified for non-interfering applicatins
Outputs are powered in isolated groups of eight
Description
The Trusted TMR Analogue Output module interfaces to 40 field devices. Triplicated diagnostic tests are performed throughout the module including measurements for current, and voltage on each portion of the voted output channel. Tests are also performed for stuck on and stuck off failures. Fault tolerance is achieved through a Triple Modular Redundant (TMR) architecture within the module for each of the 40 output channels.
Automatic line-monitoring of the field device is provided. This feature enables the module to detect both open and short circuit failures in field wiring and load devices.
The module provides on-board Sequence of Events (SOE) reporting with a resolution of 1ms. An output change of state triggers an SOE entry. Output states are automatically determined by voltage and current measurements on board the module.
Features
40 Triple Modular Redundant (TMR) output channels per module.
Comprehensive, automatic diagnostics and self-test.
Automatic line monitoring per point to detect open circuit and short circuit field wiring and load faults.
2500V dc optical isolation barrier.
On-board Sequence of Events (SOE) reporting with 1ms resolution. Module can be hot-replaced on-line using dedicated Companion (adjacent) Slot or SmartSlot (one spare slot for many modules) configurations.
Front panel output status LEDs for each point indicate output status and field wiring faults
Front panel module status LEDs indicate module health and operational mode (Active, Standby, Educated)
TUV Certified for non-interfering applicatins
Outputs are powered in isolated groups of eight
The device is an Ultraviolet-only flame detector designed
to detect fires and provide alarm outputs directly from the
detector while maintaining false alarm immunity. It
detects in the ultraviolet (UV) spectral range for
optimized speed of response.
It is fast and capable to detecting the ultraviolet (UV) rays
emitted by a burning substance and is used in high hazard
applications such as petrochemical plants, munitions
factories and other areas where flammable or explosive
liquids or solids are handled or stored.
The flame sensor adopts an ultraviolet photosensitive
tube, with qualities of highly sensitive, reliable,
dust-resistant, corrosion proof and moisture-resistant,
therefore is not sensitive in sunlight, dust, oil, tolerance of
fume, and humidity. Set in a standard calibration to detect
a flames at a distance of 25 meters, which flame created
by 2Kg ethanol in a Container of Base 33cmX33cm,
Height 5cm.
Specifications
Operating Voltage Range: 12 to 28 VDC Volts
Standby Current: â?¤10 mA @ 24 VDC
Alarm Current â?¤40 mA @ 24 VDC
Spectrum: 180~290nm
Detection Angle: 120 degree
Detection Sensitivity: Grade I, 25m@flame (Container 33cmX33cm,Height 5cm with 2Kg ethanol )
Relay Contact Load: 1A@DC24V
Normal Status: LED blinking in 5 seconds interval
Alarm Status: LED lit steady
Protection rating: IP 21
Operating Humidity Range: 10% to 93% Relative Humidity, Non-condensing
Operating Temperature Range: -20°C to 55°C
Height: 45 mm installed in Base
Diameter: 103 mm
Weight: 153g
The device is an Ultraviolet-only flame detector designed to detect fires and provide alarm outputs directly from the detector while maintaining false alarm immunity. It detects in the ultraviolet (UV) spectral range for optimized speed of response.
It is fast and capable to detecting the ultraviolet (UV) rays emitted by a burning substance and is used in high hazard applications such as petrochemical plants, munitions factories and other areas where flammable or explosive liquids or solids are handled or stored.
The flame sensor adopts an ultraviolet photosensitive tube, with qualities of highly sensitive, reliable, dust-resistant, corrosion proof and moisture-resistant, therefore is not sensitive in sunlight, dust, oil, tolerance of fume, and humidity. Set in a standard calibration to detect a flames at a distance of 25 meters, which flame created by 2Kg ethanol in a Container of Base 33cmX33cm, Height 5cm.
3. When repairing or replacing the relay, first remove the national relay spring, and then pull out the relay. Do not use excessive force or shake left and right when pulling it out, as it may damage the relay or socket.
Faults and troubleshooting methods
1. The relay contact has no output
The analysis and elimination methods of the relay contact without output are as follows:
(1) Make sure that the relay and socket should be reliably plugged in;
(2) Check that the relay should not be mechanically blocked. If foreign matter in the relay blocks the armature, the armature cannot work reliably (forward rotation) or release (reverse rotation), and the contacts cannot be reliably contacted;
(3) Check that there should be no foreign matter between the contacts, there is foreign matter between the contacts, and the contacts cannot be reliably contacted;
(4) Check that the contact resistance of the relay contact should not be too large.
2. The relay does not work or the relay with a pole cannot be reversed in the forward direction
be reliably released.
48V smoke detector with relay output is a fire safety detector device. It is widely used for Telecom or Mobile's machine room or computer room of factory or electric power. When it detects smoke, the detector sent a relay signal to fire alarm system to remind with LED lit on.
Features:
4 wire interconnection
48V DC powered
Frosting plastic
High sensitivity
To Set NC or NO
Description:
Working voltage: DC48V
Static current:
Conventional Optic Smoke Detector With Relay Output Function is a safety fire detection. It can be link with alarm system to prevent fire.
Features:
1. Strong adaptability for circumstance
2. SMT Design, High stability
3. 9-35V DC Wide voltage operating range
4. Low standby currency
5. Power supply non-polarized input
6. Twin LED for 360�° visual
7. Flashing LED power indicator
8. Remote LED indicator output
9. Metal shield, anti-electromagnetic interference