1000 Vac /800 Vdc (UL), 35 to 2000 A
North American style bolted tags high speed fuses for the protection
of DC common bus, DC drives power converters/rectifiers, reduced
rated voltage starters and high voltage traction inverters.
Ratings
Volts
1000 Vac
800 Vdc
Amps 35-2000 A
IR
25 kA RMS Sym. (35-200 A)
100 kA RMS Sym. (250-2000 A)
50 kA at 800 Vdc (35-200 A and 450-600 A)
Agency information
UL Recognized, JFHR8, E91958 on 50-600 A only
CE
FNQ-R Class CC Limitron time-delay,
rejection-type fuse
Time-delay, branch circuit, rejection-type fuse. For superior electrical
protection, Eaton recommends upgrading FNQ-R fuse applications
to Bussmann series Low-Peak LP-CC fuses, see page 1-5. For
dimensions.
Ratings
Volts
600 Vac (or less)
300 Vdc (15-20 A)
32 Vdc (self certified)
Amps 1/4-30 A
IR
200 kA RMS Sym.
20 kA DC (15 and 20 A only)
Agency information
UL Listed, Std 248-4, Class CC, Guide JDDZ, File E4273,
CSA Certified, Class 1422-01, File 53787, RoHS compliant, CE
Features
Class CC rejection feature, with appropriate fuse block, prevents
inserting lesser-rated supplementary fuses
Time-delay compatible with inrush characteristic of small control
transformers
Current limitation at Class CC levels provides maximum
component short-circuit current rating protection
200 kA interrupting rating provides high ratings for control circuit
locations
Typical applications
Line protection, small control transformers
Industrial controls and panels
Isolated, in-line fuse holders
Time-delay supplemental fuse. Color code green (250 Vac max). For superior protection, Eaton recommends upgrading to Bussmann series Low-Peak Class CC fuses.
Agency information
UL Listed, Std. 248-14, Guide JDYX; File E19180, CSA Certified, Class 1422-01, File 53787, RoHS compliant, CE
Features
Color coded for 250 Vac maximum
Melamine tube construction with nickel-plated brass endcaps
Typical applications
Circuits with high inrush currents (motor/transformer loads)
Supplemental protection for 125 Vac and 250 Vac inductive circuits
1000 Vac /800 Vdc (UL), 35 to 2000 A
North American style bolted tags high speed fuses for the protection
of DC common bus, DC drives power converters/rectifiers, reduced
rated voltage starters and high voltage traction inverters.
Ratings
Volts
1000 Vac
800 Vdc
Amps 35-2000 A
IR
25 kA RMS Sym. (35-200 A)
100 kA RMS Sym. (250-2000 A)
50 kA at 800 Vdc (35-200 A and 450-600 A)
Agency information
UL Recognized, JFHR8, E91958 on 50-600 A only
CE
A range of UL 248-19 fastacting 600 Vdc Class RK5 fuses specifically designed to protect photovoltaic power systems in extreme ambient temperature, high cycling and low level fault current conditions (reverse
current, multi-array fault).
Ratings
Volts
600 Vac to UL 248-12
600 Vdc to UL 248-19
Amps 20-400 A
IR
200 kA RMS Sym. AC
20 kA DC (20-60 A)
10 kA DC (70-400 A)
Agency information
UL Listed, Std. 248-12, Class RK5, Guide JFGA, File E335324.
Photovoltaic to UL 248-19, CSA Component Certified C22.2, CE
Features
Current limitation for non-inductive circuits provides Class
RK5 current-limiting response to ground fault and short-circuit
conditions
Designed for the protection and isolation of photovoltaic systems
Typical applications
Photovoltaic systems
Inverters
Photovoltaic system DC safety switches
Recombiner boxes
Din hrc "s" type high voltage fuse for transformer protection:
1. According to bussmann din "s" type high performance back-up fuse
2. Comply with iec282-1, din, bs
3. This fuse is intended to protect distribution networks and transformer, for indoor as well as outdoor use.
4. Any other specifications can be designed specially.
North American style bolted tag high speed fuses used for the
protection of DC common bus, DC drives, power converters /
rectifiers and reduced rated voltage starters.
Ratings
Volts
150 Vac/dc (UL)
80 Vdc 1000 A only
Amps 70-1000 A
IR
100 kA RMS Sym. (70-400 A)
200 kA RMS Sym. (450-1000 A)
20 kA at 150 Vdc (70-800 A)
100 kA at 80 Vdc (70-1000 A)
North American style bolted tag high speed fuses used for the
protection of DC common bus, DC drives, power converters /
rectifiers and reduced rated voltage starters.
Ratings
Volts
150 Vac/dc (UL)
80 Vdc 1000 A only
Amps 70-1000 A
IR
100 kA RMS Sym. (70-400 A)
200 kA RMS Sym. (450-1000 A)
20 kA at 150 Vdc (70-800 A)
100 kA at 80 Vdc (70-1000 A)
Quick Details
D/C:
Specialty Fuses 1100A 1kV 3BKN-80 AR 170M6549 Square Body Fuse
Package:
carton box
Model Number:
170M6549
Type:
fuse
Brand Name:
170M6549
Place of Origin:
Denmark
item:
Bussmann Fuse
Current:
1100A
Voltage:
690V
Datecode:
New
MOQ:
1 PC
Condition:
original & New
Warranty:
60 days
Shipping:
DHL, FEDEX, TNT, UPS, EMS, SF, etc.
Package Type:
Carton Box
Operating Temperature:
Standard
SupplyAbility
SupplyAbility:
1200 Piece/Pieces per Week Square Body Fuse
Packaging & Delivery
Packaging Details
carton box
Delivery Time
within 3 days after payment
Port:
Shanghai
Lead Time :
within 3 days after payment
Contact Data Contact arrangement :
1 form A, 1 NO
1 form C, 1 CO
Rated voltage : 28VDC, 277VAC
Max. switching voltage : 28VDC, 277VAC
Rated current : 10A
Contact material : AgZnO, AgCdO, AgNi
Min. recommended contact load :' 100mA, 5VDC
Frequency of operation : 600 ops./h
Operate/release time max. : 10ms/5ms
Electrical endurance :
AgZnO: form A, 10A, 250VAC, res., +85°C, Class B or F only 100x103 ops.
AgCdO: form A, 10A, 250VAC, res., +85°C, Class B or F only 50x103 ops.
AgNi: form A, 10A, 250VAC, res., +85°C, Class B or F only 50x103 ops.
Contact ratings, form A/form B :
10A/6A 250VAC resistive
10A/6A 28VDC resistive
Mechanical endurance, DC coil : 10x106 operations
General Information
Extended Product Type : RT6 24DC
Product ID : 2TLA010026R0000
EAN : 7350024431858
Catalog Description : Safety Relay RT6 24DC
Long Description : A universal safety relay for many safety applications. Relay outputs 3NO/1NC
Popular Downloads
Instructions and Manuals 2TLC172028M9801
Dimensions
Product Net Depth / Length : 120 mm
Product Net Height : 84 mm
Product Net Width : 45 mm
Product Net Weight : 0.33 0 kg
Certificates and Declarations (Document Number)
Declaration of Conformity - CE : 2TLC172078D0201
Instructions and Manuals : 2TLC172028M9801
F 200 A type with neutral pole on the left
Function: protection against the effects of sinusoidal alternating and direct pulsating earth fault currents; protection against indirect contacts and additional protection against direct contacts (with In=30 mA). Product helpful where for installation habits, for wiring with busbars or cables, for special needs neutral on the left is needed.