Din hrc "s" type high voltage fuse for transformer protection:
1. According to bussmann din "s" type high performance back-up fuse
2. Comply with iec282-1, din, bs
3. This fuse is intended to protect distribution networks and transformer, for indoor as well as outdoor use.
4. Any other specifications can be designed specially.
Type rated voltage (kv) rated current (a) diameter (mm) length (mm)
Xrnt1 3.6 6.3 10 16 20 25 31.5 40 51 192
Xrnt1 7.2 6.3 10 16 20 25 31.5 40 50 63 51 292
Xrnt1 7.2 80 100 125 160 76 292
Xrnt1 12 10 16 20 25 31.5 40 51 292
Xrnt1 12 50 63 71 80 100 76 292
Xrnt1 12 125 76 292
Xrnt1 12 160 200 88 292
Xrnt1 24 6.3 10 16 20 25 31.5 40 51 442
Xrnt1 24 50 63 71 80 100 76 442
Xrnt1 24 125 76 442
Xrnt1 24 160 88 442
Xrnt1 40.5 3.15 6.3 10 16 20 25 51 537
Xrnt1 40.5 31.5 40 76 537
Xrnt1 40.5 63 88 537
3pcs a carton
Technical parameters for XRNT-36KV fuse: Rated voltage: 36KV Rated current of fuse: 25A Dimension: 442mm*51mm Type Rated voltage (KV) Rated current (A) Diameter (mm) Length (mm) XRNT1 3.6 6.3 10 16 20 25 31.5 40 51 192 XRNT1 7.2 6.3 10 16 20 25 31.5 40 50 63 51 292 XRNT1 7.2 80 100 125 160 76 292 XRNT1 12 10 16 20 25 31.5 40 51 292 XRNT1 12 50 63 71 80 100 76 292 XRNT1 12 125 76 292 XRNT1 12 160 200 88 292 XRNT1 24 6.3 10 16 20 25 31.5 40 51 442 XRNT1 24 50 63 71 80 100 76 442 XRNT1 24 125 76 442 XRNT1 24 160 88 442 XRNT1 40.5 3.15 6.3 10 16 20 25 51 537 XRNT1 40.5 31.5 40 76 537 XRNT1 40.5 63 88 537 3pcs a carton
Supplier: Engineering components for automotive, electrical, construction, transmission tower projects , rail road components hardware like different types of washers, circlips & retaining rings, clips , clamps ,hose clamp , spring band clamps ,metal pressed parts, wire form parts.
Services: Manufacturing & sourcing agents
Advantages: 1. Full scope protection 2. High breaking capability 3. High voltage current limiting fuse 4. Design as customer required 5. Utility model patent 6. Appearance design patent Specification: Material: ceramic Color: white, brown Length: 142mm, 192mm, 195mm, 260mm, 355mm, 465mm Diameter: 22mm, 25mm, 51mm Type rated voltage (kv) rated current (a) diameter (mm) length (mm) Xrnp1 3.6 0.5 1 2 3.15 6.3 22 25 142 Xrnp1 7.2 0.5 1 2 3.15 6.3 22 25 142 Xrnp1 7.2 0.5 1 2 3.15 6.3 22 25 192 195 Xrnp1 10(12) 0.5 1 2 3.15 22 25 192 195 Xrnp1 24 0.5 1 2 3.15 22 25 355 Xrnp1 24 0.5 1 2 3.15 30 365 Xrnp1 40.5 0.5 1 2 3.15 30 465 3 pcs a carton
Supplier: Ndfeb magnet, magnetic assembly, ferrite magnets, smco, halbach array magnet, surge protection device, gas discharge tube, lightning protection earthing system, spd, gdt, arrester, surge, lightning
Supplier: Biscuits, toothpaste, laminated rolls, packing material, raw material, extra neutral alcohol, shrink films, copier paper, aluminum foil, deo, perfumes, toothpaste, glycerine, pet resins, cable, wires, dg sets, transformers, automobiles, bikes, electric bikes, vehicles, canned food, coffee, peanut butter, ena, petroleum jelly, soap noodles, pp bags, corrugated boxes, personal care products, shampoo, conditioner, face cream, candies, lollipops, skin care, hair care, over the counter, a4 paper, paper, packing film, packaging film
Services: Exporting from india
Supplier: Consumer electronics, industrial control, and high speed connectivity cables and connectors.
Services: Manufacturer, designing, customization for consumer electronics, industrial control, and high speed connectivity cables and connectors.
Buyer: Consumer electronics, industrial control, and high speed connectivity cables and connectors.
SANDI SERIES charging module is for electric vehicle charging station. With single-phase non neutral conductor AC input, it has the advantages of high efficiency, high power density and low harmonic. Functional details 1. Hot plug Plug technology is applied to the charging module to provide convenience for installation and maintenance. The access of the charging module to the system shall not disturb the output voltage of the system. 2. Advanced current sharing technology Under constant voltage working mode, the charging modules can share current automatically within 10S, with degree of unbalance less than �±0.5A. 3. Control of input limited power Refer to Fig. 1-10 for the relation between the output power and input voltage of the charging module. When the input voltage is within 360 Vac ~ 450 Vac (return difference is less than 5V), the module can output the maximum power of 20 KW; when the input voltage is within 260 Vac ~ 320 Vac, the module can still work normally under limited power mode. 4. Control of output constant power When there is a rated input voltage, the output power of the module is 20 KW. Refer to Fig. 11 for the relation between the output voltage and the output current of the module. The SD75050 module uses two operating modes with output voltage ranges of 50 to 750V. The module only selects the operating mode based on the value of the received demand voltage, and does not select the operating mode based on the actual output voltage. 5. Temperature limited power 6. Regulation of output current limiting point 8. Regulation of output voltage The output voltage of the module can be regulated constantly through the external monitoring module, with regulation range of 50Vdc ~ 750Vdc and minimum regulation step of 0.1 Vdc. 9. Fan control The built-in processor of the module can regulate the speed of the fan according to the internal temperature and output current of the module. 10. Protection of input overvoltage/ voltage shortage 11. Output overvoltage protection The overvoltage protection point is 260Vdc ~770Vdc (�±10 Vdc). Default is 778Vdc.The module can be started after manual intervention upon overvoltage protection. 12. Over-temperature protection The environmental over-temperature protection point is 80�°C. When the DC panel has a temperature over 100�°C, the module will stop working; when the DC panel has a temperature below 90�°C, the module will automatically work again. 13. Protection of internal bus fault When the internal bus voltage of the module is beyond the overvoltage/ voltage shortage protection point, the module will be powered off automatically. At this time, there is no output from the module and the fault indicator light is on. 14. Short circuit protection In case of short circuit of the module, it will be subjected to protective shutdown and the red indicator light of the panel is on, and this condition will be transmitted to the monitor of the "module fault".