Please click here to check who's online and chat with them.

Find Verified Auto Pressure Transducer (Ceramic) (Apt) Suppliers, Manufacturers and Wholesalers

Nov-10-06
 
Ceramic rice cooker

Led display , intelligent computer digital control , pressure cabin design . Make rice , pot rice , and sticky rice . Timer 24 hours . Adopt high effective heating system to get the best optimization of the power use .

Two pieces put in one carton , gross weight
:10.3kgs dimensions :55*37.5*26
Nov-10-06
 
Slow cooker

Taking the traditonal chinese food culture , created the natural ceramic inner pot . Keeping fresh for a long time . Help people live longer and healthier . It can save 35% electricity compare with the normal tile pot . Including braising , boiling , and stewing .

4 pcs pack in one carton , gross weight :16.2 ,
Dimensions :56*28.5*56.5
GOLD Member
Apr-02-20
 
Product Information
1.Product Name: Infrared Thermometer
2.Model / Specification: AET R701
Maximum allowable error: 0.2 C (35 C ~ 42 C)
0.3 C (below 35 C or above 42 C)
3. Power supply: two AAA batteries (DC3V)
4. Memory function: 32 issues
5.Auto power off: about one minute
6.Body weight: about 138g
7.Appearance size: 146mm * 90mm * 41mm
8. Product technical requirements number:
9. Registration certificate number:
10. Production license number:
11. Operating environment: temperature is 16 ~ 35
Relative humidity: 15% ~ 80%;
Air pressure: 70 ~ 106kPa
12. Transportation and storage environment: the temperature is -20 ~ 55 4
Relative humidity: 15% ~ 93%
Air pressure: 70 ~ 106kPa
Mar-16-21
 
1,Wrist Band Range: 135-195mm
2,Display: Digital liquid crystal display
3,Pressure Range: 0-280mmHg
4,Pulse Range: 40-199Times/Min
5,Pressure Mode: Air Pump Pressurizes Automatically
6,Decompression Mode: Solenoid valve Controls Decompression
7,Accuracy Rating:Pressure Value: 3mm Hg; Heart Rate Value 5%
8,Memory Capacity: Double 90 Pairs
9,Force Touch: Semiconductor pressure Sensor
11,Operating Temperature and Humidity: +10 C - +40 C/40% - 85%R.H.
12,Preservation Temperature and Humidity:-20C - +50C/15% - 90%R.H.
13,Power Supply:2*AAA Battery
14,Product Features:
a),Intelligent Pressure Mode
b),Ninety Pairs Data Memory Function
c),WHO Blood Pressure Health Status Alert
d),Irregular Heartbeat Lifting Function
e),Overpressure Protection Function
f),Intelligent Automatic Shutdown Function
g),The Measurement Results Can Be Queried Sequentially
h),Three - Color - Dimensional Backlight, Blood Pressure More Visual.
15,Packing: 100Pcs/Carton; 20ft container: 220Cartons
Aug-31-12
 
Pt124b-123/123t series melt pressure transducer(flexible stem & high accuracy)can measure the pressure and temperature in one point. The model pt124b-123t is with thermocouple. This series adopts special construction and excellent alloy elastic membrane to reduce the thermal draft and improve the accuracy. Zero & full span can be adjustable, amplified signal can be connected with plc, which is the international standard. It is suitable for pressure measuring and controlling in melt fluid medium, such as the plastic & polymer in the process equipments. Can replace dynisco / gefran /gp50 etc. International brand absolutely.

Specification
Pressure range:0-3.5mpa to 0-150mpa
Output:2mv/v 3.33mv/v0~5v 0~10v 4-20ma
Input voltage:10vdc24vdc
Accuracy:+/-0.5%fs, +/-0.25%fs
(including linearity , repeatability & hysteresis )
Repeatability:+/-0.2% fso
Construction:Wheatstone bridge
Bridge resistance:Input: 345 ohms minimum output: 350 ohms+/-10%
Overload pressure:1.5*fso
Internal shunt calibration:80%+/-1%
Insulation resistance:200megohms @100vdc
Standard wetted partsDiaphragm coated 15-5ph sst
Mounting torque500inch/lbs , maximum
Max. Diaphragm temp:0~400 degree
Electronic operating temperature:-25 - +85degree
Electric connector: 6pin
Thermocouple type:J, k, e, pt100 optional
Process connector:1/2-20unf, m14*1.5, m18*1.5, customer design.

Application:
Chemical fiber & spinning equipment
Plastic and rubber, polyester process equipment
Other pressure measurement and control

Feature:
High-standard quality
Stainless steel seal
Simple installation
Completely interchange similar import products
Internal 80% calibration
Excellent stability.


Specail carton
3653 Auto Pressure Transducer (Ceramic) (Apt) Suppliers
Short on time? Let Auto Pressure Transducer (Ceramic) (Apt) sellers contact you.
Oct-29-13
Supplier From Xiaogan, Hubei, China
Mar-13-09
Supplier From Jiangsu, China
Jan-02-08
 
Nominal Scale:
35KPa ,100KPa, 250KPa, 600KPa, 1MPa, 1.6MPa, 2.5MPa, 4MPa, 6MPa, 10MPa, 16MPa, 25MPa, 40MPa, 60MPa
Overload Capacity:
2 times £íº35KPa íºC 2.5MPa£©
1.5 times (4MPa íºC 60MPa)
Accuracy: ¡À0.1%F.S., ¡À0.25%F.S., ¡À0.5%F.S.
Power Supply: 1mADC or 5VDC(Optional)
Long Term Stability: ¡À0.2%F.S./ Y
Operating temperature: -30¡æ ¡« 100¡æ
Insulation resistance: £¾100M¦¸(100VDC)
GOLD Member
Apr-22-25

Polysaccharide Cas: 9000-30-0, Food Grade

$2.00K - $5.00K / Ton (US) (FOB)
MOQ: 1  Tons (US)
Sample Available
 
escription:
Guar gum is obtained from the endosperm part of Cyamposis tetragonolobus seeds after removing the skin and germ. After drying and grinding, water is added, pressure hydrolysis is carried out and precipitation is made with 20% ethanol. After centrifugation, the endosperm is dried and crushed. Guar gum is a nonionic galactomannanextracted from the endosperm of guar bean, a leguminous plant. Guar gum and It's derivatives have good water solubility and high viscosity at low mass fraction.
Application:

The most important property of guar is the ability to hydrate rapidly in cold water to attain a very high viscosity. In addition to the food industry, guar is used in the mining, paper, textile, ceramic, paint, cosmetic, pharmaceutical, explosive, and other industries.
In food industry, guar gum is used in frozen food, like ice-cream, stop ice dreg from forming and increase the frozen stability; baking food: keep the humidity and improve the texture; drink: improve taste and stabilize particle suspension; salad dressing: thickener, alternative oil; cheese and cream: improve the texture; cooked meat food: maintain water, increase oily slippery feeling; vegetarian food: alternative fat ingredients, keep moisture.
VERIFIED
Oct-04-21
 
Today, many healthcare professionals are shifting to automatic B.P. monitors. Besides being mercury free, automatic digital B.P. monitor gives accurate reading, it is more easy to use and 90 memory helps in better monitoring of the B.P.
and managing health in a more simpler and accurate way.
EU has recently banned the sale of raw mercury due to waste management hazards related to disposal of waste mercury; which has led to ban on using mercury in sphygmomanometers, thermometers and other medical devices.
Automatic B.P. monitors are Mercury Free and substitute conventional type of sphygmomanometers.
BPX is thus a safer and a time saving solution with many added features.
FEATURES
LCD Display for clear visualization.
Recall values from Memory recall button.
Memory capacity of 90.
Systolic/ Diastolic pressure and pulse rate measurement.
Automatic inflation and deflation of cuff.
Auto shut off after one minute of last key operation.
Specially designed device and cuff to prevent electrical shocks.
Minimum Order Quantity 500 Piece
Usage/Application Hospital,Clinic
Power Source Electric
Measurement Range high
Accuracy 0.03 (pressure)
Cuff Circumference 22-42 cm
Usage Hospital, Clinic
Features LCD Display for clear visualization. Recall values from Memory recall button.
Brand Multib
GOLD Member
Feb-25-25

Lithium Hydroxide Cas 1310-65-2

$0
MOQ: Not Specified
Sample Available
Supplier From North York, Ontario, Canada
 
Lithium hydroxide can be used as developing agent and lubricating oil for spectral analysis The additive of alkaline battery electrolyte can increase the electric capacity by 12 to 15 and increase the service life by 2 to 3 times
It can be used as an absorbent for carbon dioxide and can purify the air in submarines
The chemical equation is 2LiOHsCO2gLi2CO3sH2Ol
It is used to make lithium salt and lithiumbased grease electrolyte of alkaline battery absorption liquid of lithium bromide refrigerator etc used in petroleum chemical industry light industry nuclear industry etc When used in alkaline batteries the aluminum content is not more than 006 and the lead content is not more than 001 It is used as an analytical reagent a photographic developer and also in the manufacture of lithium it is used as a raw material for the preparation of lithium compounds It can also be used in metallurgy petroleum glass ceramics and other industries
Lithium hydroxide is mainly consumed for the production of lithium greases A popular lithium grease is lithium stearate which is a generalpurpose lubricating grease due to its high resistance to water and usefulness at both high and low temperatures
Carbon dioxide scrubbing
Lithium hydroxide is used in breathing gas purification systems for spacecraft submarines and rebreathers to remove carbon dioxide from exhaled gas by producing lithium carbonate and water
It is used as a heat transfer medium and as a storagebattery electrolyte It is also used in ceramics and some Portland cement formulations Lithium hydroxide isotopically enriched in lithium7 is used to alkalize the reactor coolant in pressurized water reactors for corrosion control
GOLD Member
Aug-22-23

Used Air Compressor

$565.00K - $670.00K
MOQ: 1  Pieces
 
Type Used Air Compressor
Color Blue

Feature Auto Controller
Voltage 220V
Condition Used
Frequency 60Hz
Automatic Grade Semi Automatic
Power Source Electric
Pressure High Pressure
Port India port
Jun-26-19
 
Intek Instruments is engaged in offering a wide gamut of high quality Linear Transducer / Linear Potentiometer / Linear Scale / LVDT Transducer / Displacement Transducer / Contactless Magnetostrictive Transducer.

We are an Authorised Distributor for Gefran Italy in North India. We also deals in other brands, includes, Novotechnik, Opkon, Minor, Balluff, Waycon, etc.

For authentic price and further information, please contact us.
Sep-18-10
 
Ultrasonic Transducers Name Method

Eg, UCE-6845D-20LA PZT8

UCE mean our company logol.

68 is stand for the dimetions of radiation head, 45 is stand for the dimetions of the piezoelectric ceramic,PZT8 is mean the material of piezoelectric ceramic,PZT8 is yellow ceramic,PZT4 is black.

Ultrasonic Transducers is one of main products of at UCE ultrasonic,which used the piezoelectric effort to realize transduction between electric and sound energy,also named as BLT transducer,ultrasonic transducer normally used in ultrasonic cleaning industry,high power ultrasonic etc.
Sep-09-09
 
The platform measures the three orthogonal force components along the X, Y, and Z axes, and the moments about the three axes, producing a total of six outputs. The high sensitivity, low crosstalk, excellent repeatability and long term stability of this platform makes it ideal for research and clinical studies.

The JP5050 is easy to use and is available in 5,000 Newton vertical capacity.

Fx, Fy Capacity (N): 2.5 KN
Fz Capacity (N): 5 KN
Mx Capacity (Nm): 1 KNm
My Capacity (Nm): 1.5 KNm
Mz Capacity (Nm): 0.75 KNm
Fx, Fy Sensitivity (µV/[V*N]): 0.30
Fz Sensitivity (µV/[V*N]): 0.12
Mx, My Sensitivity (µV/[V*Nm]): 0.25
Mz Sensitivity (µV/[V*Nm]): 0.37

Safe Temperature Range: 0í½50OC
Compensated humidity Range: 20í½70%RH
Safe Excitation Voltage: 12V DC

Crosstalk: Less than 2% on all channels
Sensitivity Change with Temperature:í_1%/ípC
Fx, Fy, Fz hysteresis: í_ 1% Full Scale Output
Fx, Fy, Fz non-linearity: í_ 1%Full Scale Output



400*600*117mm
Net Weight: 35 Kg
Packaged in carton
Sep-09-09
 
Applications
An Electromyography (EMG) use EMG electrodes to pick up the electromyographic signal directly from the skin surface or within the subjects muscle using disposable fine-wire electrodes. Both are typically expressed in SI units micro Volt (mv). The Bioforcen-TB0810 model Biomechanics EMG can be used for biomechanics, engineering, medical research, orthopedics, rehabilitation evaluation, prosthetics, and general industrial uses. Specific uses include gait analysis, testing or stability analysis, neurological analysis, prosthetics fitting, athletic performance, shoe design, and force, power, and work studies.

Description
The EMG signal from each muscle is individually pre-amplified, band-pass filtered prior to digitization, and then converted to a binary sample for each of the channels. These operations are all performed directly in the subject back-pack to maximize signal quality. The binary information is then sent from the subject back-pack unit, via a single lightweight cable or wireless, to the desktop unit where it checked for transmission accuracy and then converted to an analog signal suitable for almost any analog data recording system. The desktop unit provides full electrical safety isolation for the subject.

AMPLIFICATION
The Bioforcen-TB0810 model Biomechanics EMG provides excitation and amplification for multiple channels in one convenient package. These amplifiers process the transducer signals and provide outputs suitable for an A/D converter so that the data can be stored and processed by a computer.

CALIBRATION
Each platform is inspected and tested in JUNE calibration facility. The calibration procedure provides a detailed sensitivity matrix and a complete test of all system components, including the amplifier and the connecting cable if ordered together.

SOFTWARE
Automated data collection and reduction requires a computer and software. Bioforcen-Analysis, Bioforcen-software package, is specifically designed for biomechanics .

EMG channels: 8
High pass filter (1st order): 10 Hz
Low pass filter (2nd order): 1000Hz (Butterworth)
EMG signal input mode: Raw Signal (¡À3 mV)
EMG signal output mode: Signal (0~2 V)
EMG channel sample rate 500~4,000 samples per second per channel.

Number of event switches: 8 switches, Independent of EMG channels
Indicator Lights: USB ok, Status ok

Safe Temperature Range: 0í½50OC
Compensated humidity Range: 20í½70%RH
Safe Excitation Voltage: 9 V DC


180*80*20mm
Net Weight: 260g
Packaged in aluminum alloy chest
VERIFIED
Oct-11-18
Supplier From Ghaziabad, Uttar Pradesh, India
May-11-11
 
MCC-w Miniature load cell uses the stainless steel structure , High precision ,Low contour ,sealed waterproofing ,stable performance; has strongly anti-torsion , anti-side ability, is suitable in electronic weighing apparatus and so on for automobile scale, track scale, platform scale, bunker scale, crane, and compression testing machine.

Specification:
Range 20,30,50,100,200 ,300,500,1000 kg

Bridge voltage :10 V(DC)
Output signal :1.5 mV/V
Non-linearity :0.5 % F¡¤S
Hysteresis :0.5 % F¡¤S
Non-repeatability :0.5 % F¡¤S
Temperature dirft :0.05 F¡¤S/¡æ
Zero output :¡Ü2 % F¡¤S
Operating temperature :-20~80.


Standard export package.
Jun-02-10

Ip/ep Converter

$170
MOQ: Not Specified
 
Ip/ep converter
Ip/ep transducer
Electropneumatic transducer
Input electrical current:4-20ma, 0-10v
Output pressure:20-100kpa
Et-500 is electropneumatic transducer equipment, it can decrease supply pressure to produce output pressre which is effectively proportional to input electric signal.
Supply pressure range:125kpaí½1000kpa.With bulk augmenter supply big flow (20.4 m3/h).
Features:
Flow rate: 7.6m3/h when supply pressure is 175kpa
20.0m3/h when supply pressure is 700kpa
Min/max. Supply pressure:
Minimum-3psig(21kpa) above maximum output
Maximum-100psig(700kpa)
Sensitivity: <+-0.15% of span per 10 psig
Linearity:<+-0.75% of span
Repeaability: <0.5% of span
Hysteresis: <0.1% of span
Flow rate: 4.5 scfm(7.6m3/hr anr) at 100 psig(175 kpa) supply
12.0 scfm(20.0m3/hr anr) at 100 psig(700 kpa) supply
Maximum air consumption: 0.05scfm(0.07m3/hr ) midrange typical
Port size:
1/4 npt(pneumatic)
1/2 npt(electric)
Weight: 2.1lb.(0.94kg)
Input current:4-20ma
Output pressure:20-800kpa



Plastic bag, inner box, master carton
Jun-02-10

Electropneumatic Transducer

$100 - $170
MOQ: Not Specified
 
Electropneumatic transducer
Input electrical current:4-20ma, 0-10v
Output pressure:20-100kpa
Et-500 is electropneumatic transducer equipment, it can decrease supply pressure to produce output pressre which is effectively proportional to input electric signal.
Supply pressure range:125kpaí½1000kpa.With bulk augmenter supply big flow (20.4 m3/h).
Features:
Flow rate: 7.6m3/h when supply pressure is 175kpa
20.0m3/h when supply pressure is 700kpa
Min/max. Supply pressure:
Minimum-3psig(21kpa) above maximum output
Maximum-100psig(700kpa)
Sensitivity: <+-0.15% of span per 10 psig
Linearity:<+-0.75% of span
Repeaability: <0.5% of span
Hysteresis: <0.1% of span
Flow rate: 4.5 scfm(7.6m3/hr anr) at 100 psig(175 kpa) supply
12.0 scfm(20.0m3/hr anr) at 100 psig(700 kpa) supply
Maximum air consumption: 0.05scfm(0.07m3/hr ) midrange typical
Port size:
1/4 npt(pneumatic)
1/2 npt(electric)
Weight: 2.1lb.(0.94kg)
Input current:4-20ma
Output pressure:20-800kpa



Plastic bag, inner box, master carton
3653 Auto Pressure Transducer (Ceramic) (Apt) Suppliers
Short on time? Let Auto Pressure Transducer (Ceramic) (Apt) sellers contact you.