Buyer is interested to receive quotations for the following RFQ -
Product Name: Electrical Immersion Heaters
Specifications:
Type: Vulcanic Flanged Immersion Heater
Make: Vulcanic
Quantity: 2 Units Initially, Later Less Than Container Load (LCL)
Standards: Relevant IEC Standards
Electrical Specifications: SP-1103 And SP-1107
Process And Mechanical Specifications: SP-2454
Supply Characteristics: As Per DEP, With Deviations Specified
Allowed Total Harmonic Distortion (THD): 6.5%
Rated Supply Voltage: 415 V Plus Or Minus 5%, 3-Phase, 4-Wire
Rated Frequency: 50 Hz Plus Or Minus 2%
Power Supply: 3 KW
Prospective Short Circuit Current At PC: KA RMS, KA Peak, Or Fuse Protection Rated In A
P&C Assembly Service Conditions: As Per DEP, Specify Separately
Heater Service Conditions: As Per DEP, Specify Separately
Area Classification: Zone 2
Temperature Class: T3
Gas Group: IIB
Incoming Switch In P&C Assembly: Required
Key Interlock: Not Required
Unit Transformer: Not Required
Transformer In Heater Supplier Scope: No
HV Supply: Not Applicable
Transformer Data: Not Applicable
Input Signal: 4 To 20 MA
Transducers For Remote Metering: In The Heater
Suncover: Required
Over-Temperature Control: Via Instrument Interface
Incoming Cable Size: 4C X 16 Sq Mm, M25 Gland
Fuse Type: DIN
Outgoing Cable Size: 2 X 2 X 1.13 Mm
P&C Assembly Space Heater: Required
Space Heater Cable Size: 3C X 4 Sq Mm, M20 Gland
Witnessed Inspection And Testing: Not Required
Cable Entry: From Below
Document Language: English
Equipment Language: English
Cable Gland Plate: Drilled
Cable Glands: Required
Gland Type: 3/4 Inch NPT, Brass Double Compression
Nearest Service Organization: Vulcanic, Torrelavega, Spain
Maximum Power Requirement: 3 KW
P&C Assembly Space Heater Included: Yes
Main Terminal Box Space Heater Included: Yes
Suncover Over Main Terminal Box: Yes
Over-Temperature Devices: PT100
Cooling: Natural
Specified Tender Documentation Attached: No
Detailed Test Protocol Attached: No
Heating Element Material: SS321
Flange Material: SS316
GDD150 Box: SS316L, No
Material Compliance: SP-2337 And SP-2454
Air Flow Capacity: 148 Nm3/Hr
Minimum Inlet Air Temperature: 5°C
Outlet Air Temperature: 54°C
Maximum Air Pressure: 950 KPag
Heater Element Head Outer Diameter: 204 Mm
Heating Element Diameter: 86 Mm
Heating Element Length: 800 Mm
Heating Element Total Length: 1,143 Mm
Heater Shell Outer Diameter: 114.3 Mm (4 Inches)
Heater Shell Total Length: 996 Mm
Heater Shell: Excluded From Scope Of Supply
Bellelli Scope: NPT To Metric Adapters For All Cable Glands
Supply Requirement: Compliance With All Attached Documents
Quotation Requirement: All Deviations And Exceptions Must Be Clearly Identified And Detailed For Evaluation And Approval
Quantity Required : 1 Less than Container Load/LCL
Please quote for the following wholesale product requirement -
Product Name: Electrical Immersion Heaters
Specifications:
Qyt: 2 Units initially later LCL.( Relevant IEC Standards )
Note: The proposed supply shall comply with all the attached documents. Any deviations or exceptions shall be clearly identified and detailed in your quotation for our evaluation and approval.
Please note that the heater shell is not included in the scope of supply.
Electrical : SP-1103 & SP-1107
Process/mechanical : SP-2454
Supply Characteristics : as per DEP / deviations:
Allowed Total Harmonic Distortion (THD) : 6.5%
Rated Supply Voltage : 415 V ± 5%, 3-phase, 4-wire
Rated Frequency : 50 Hz ± 2%
Power Supply : 3 kW
Prospective short circuit current at PC : kA r.m.s; kA peak; or protected by fuse rated: A
Service conditions P&C Assembly : as per DEP (specify separately)
Service conditions Heater : as per DEP (specify separately)
Area Classification Heater : Zone 2 Temp class: T3 ;Gas group: IIB
Incoming switch required in P&C Assembly : yes ; key interlock: no
Unit Transformer : no; in scope of heater supplier : no
HV supply (if applicable) :N/A
Transformer data (if applicable) :N/A
Input signal : 4 - 20 mA
Transducers for remote metering : in the heater Suncover required : yes
Over-temperature control : via intrument inferface Cable size : incoming 4C x 16 sqmm M25 Gland *)
Type of fuses :DIN : outgoing 2 x 2 x 1.13 mm *)
Space heater in P&C Assembly : yes Space Heater cable size : 3C x 4 sqmm M20 Gland
Witnessed inspection/test required : no Cable entry : from below
Language on documents :English Cable gland plate : drilled
Language on equipment :English Glands required : yes
Gland type : 3/4" NPT (brass double compression)
Make and type :Vulcanic Flanged immersion Heater
Name / location nearest service organisation :Vulcanic - Spain (Torrelavega)
Maximum power requirements : 3 kW at pf:
Rated input current : A / phase Voltage : V
Maximum heater current : A
Peak inrush current : A
Transformer data (if applicable) :N/A
P&C Assembly space heater included : yes
Main terminal box space heater included : yes
Suncover over main terminal box : yes
Over-temperature devices :PT 100
Cooling : natural
Specified tender documentation attached : no
Detailed test protocol attached : no
Element material :SS 321
Flange Material :SS316
GDD150 box :SS316L No
All materials shall be in line with SP-2337 and SP-2454 S
PECIAL REQUIREMENTS AND REMARKS REMARKS ON REVISIONS
1. Heater is sized for 148 Nm3/hr of Air, Inlet minimum temperature: 5°C,
Outlet temperature: 54°C, maximum Air pressure 950 kPag.
2. Heater element dimensions: OD Head 204 mm, Heating element diameter 86mm, Heating element length 800 mm, Total length 1143 mm.
3. Heater shell dimension: OD 114,3mm (4"), Total lenght 996mm
4. Bellelli scope includes NPT to metric adapters for all cable glands.
Quantity Required : 1 Less than Container Load/LCL
Please quote for the following wholesale product requirement -
Product Name: Hot Water Vertical Calorifier SS 316L
Specifications:
Pressure: 10 Bar Working Pressure
Capacity: 5,000 Liters – 5 Units, 4,000 Liters – 4 Units
Supplier From: India Only
Note: Share Me Offer With Technical Data Sheet
Please provide a quotation to the following requirement from importer -
Product Name: Commercial Water Heaters
Specifications :
Types: Electric Water Heaters, Gas Water Heaters, Storage Water Heaters
Purpose: Retail
Note: Contact Via Email Only
HS Code: 841919
Packaging Terms : Cartons and Wooden Crates
Please provide a quotation to the following requirement from importer -
Product Name: Cabinet Heater And Liquid Line Dryer Filter
Specifications:
Cabinet Heater 230vac, 130w, Size 80mm X 118mm X 140mm ,
Model /part No.: Sk 3107.000 Qty- 4
Liquid Line Dryer Filter, 3/8in Solder Odf , Model /part No.: Ihs3 Qty 5
For Refrigeration And Air Conditioning Systems
Buyer is interested to receive quotations for the following RFQ -
Product Name: Cabinet Heater And Liquid Line Dryer Filter
Specifications:
Cabinet Heater 230vac, 130w, Size 80mm X 118mm X 140mm , Model /part No.: Sk 3107.000 Qty- 4
Liquid Line Dryer Filter, 3/8in Solder Odf , Model /part No.: Ihs3 Qty 5
For Refrigeration And Air Conditioning Systems
Please provide a quotation to the following requirement from the importer -
Product Name: Solar Water Heater And PV
Specifications:
1. Solar panel to heat water up to +95 Celsius degree and circulate 35 m3 /h in close loop to be attached with the existing 400KW boiler
2. Solar Panels to get 45KW and 200kw power with on grid system (Battery not required)
3. Water temperature controller 30 – 40 Celsius degree 600 L/h for our food production line to control and stabilize the water temperature in patch.
4. Day-lighting (sunlight) for hangars
Please provide a quotation to the following requirement from importer -
Product Name: Solar Heaters
Specifications:
Type: Solar Water Heater
Heating System: Thermosyphon (Passive)
Usage: Home, House, Project, Swimming Pool
Solar Collector: Vacuum Tube 58*1800 or 47*1500
Coating Of The Tube: SS-CU-AIN/ALN
Tube Material: High Borosilicate Glass
Material Of The Inner Tank: sus304-2B Imported Food Grade Stainless Steel
Insulation: Polyurethane Foam
Material Of Outer Tank: Galvanized Steel Alloy Or Stainless Steel
Frame: Galvanized Steel Alloy Or Stainless Steel Or Aluminum Alloy
Heat Preservation:72-80 Hours
Electrical Heating:1.5-3KW
Specifications:
Origin: Any port
Capacity: 1.0 & 2.5 meter cube
System: Full system with panel and chiller
Solar system: On-grid
Installation regions: Kingdom of Bahrain
Quantity Required : MOQ
Shipping Terms : CIF
Destination Port : King Ahmed Khalif Bin Salman Port, Bahrain
Specifications :
Type: Solar Water Heater
Heating System: Thermosyphon (Passive)
Usage: Home, House, Project, Swimming Pool
Solar Collector: Vacuum Tube 58*1800 or 47*1500
Coating Of The Tube: SS-CU-AIN/ALN
Tube Material: High Borosilicate Glass
Material Of The Inner Tank: SUS304-2B Imported Food Grade Stainless Steel
Insulation: Polyurethane Foam
Material Of Outer Tank: Galvanized Steel Alloy Or Stainless Steel
Frame: Galvanized Steel Alloy Or Stainless Steel Or Aluminum Alloy
Heat Preservation: 72-80 Hours
Electrical Heating: 1.5-3KW
Specifications:
- 2400w And 3400w
- Sample Of 2-3 Units
- First Order: 20 To 50 Units /month
- Certificate Of European Standard With Pictures And Specification Of Product Required
Buyer is interested to receive quotations for the following RFQ -
Product Name: Air Heater
Specifications:
5 KW
to run on heavy oil such as Hydraulic oil and Compressor oil, As well as diesel oil.
Quantity : 1 unit for sample later more as per the requirement
The buyer is interested to receive quotations for the following RFQ -
Product Name: Electric Hair Remover Wax Heaters
Specifications:
Application: Use On Large Areas Of The Body: Leg
Material: Plastic And Aluminium
Color: Purple
Style: Portable Electric Wax Warmer
Service: OEM / ODM
Certification: CE
Warranty: 1 Year