Specifications:
TVMUGR-880000-220-11-4-020-00000G-000 —
Honeywell “MultiTrend GR” Series Paperless/Graphic Recorders (advanced graphical recorders / HMIs). They are colour TFT touch-screen recorders that log process signals (many analog inputs), display trends, alarms and provide on-device data storage (and removable storage). The long TVMUGR part number encodes specific I/O, display and software options/configuration.
ontinuous recording and visualization of process variables (temperature, pressure, flow, level, etc.), operator HMI display, alarm management, historical data logging for QA/compliance and process troubleshooting. Common in process plants, utilities, heat treatment, batch records, and anywhere multiple analog inputs must be monitored and archived.
Please quote for the following wholesale product requirement -
Product Name: Gas Chromatography Equipment
Specifications:
Purpose
The equipment is intended for the identification and quantitative determination of acetic acid, volatile poisons (e.g., chloroform, ethanol, methanol), and other volatile organic compounds (VOCs) from biological samples (blood, urine, internal organs) as part of forensic chemical-toxicological analysis.
Main Technical Specifications
Thermostatting System
Number of independent heating zones: at least 8.
Maximum column oven temperature: at least 460 °C.
Temperature programming rate: from 0.1 to at least 160 °C/min.
Number of temperature steps: at least 24.
Maximum hold time per temperature step: at least 999 minutes.
Temperature maintenance accuracy: not less than ±0.03 °C.
Temperature programming repeatability: not more than 1%.
Hardware and software overheat protection.
Gas Supply System
Number of electronic pressure control (EPC) channels: at least 13.
Gas flow range: from 0 to at least 999.999 ml/min.
Flow setting accuracy: at least 0.001 ml/min.
Pressure setting accuracy: at least 6.89 Pa.
Protection against heating activation without gas supply.
Injector System
Injector type: Split/Splitless with septum purge.
Maximum injector temperature: at least 450 °C
Support for direct injection mode.
Flame Ionization Detector (FID)
Detection limit: not more than 2 picograms/second (for n-hexadecane).
Operating temperature range: up to 450 °C.
Low background noise level.
High sensitivity to hydrocarbons and volatile organic compounds.
Software
Control of all gas chromatograph and autosampler parameters via PC.
Support for at least 4 channels for chromatographic signal acquisition.
Signal recording accuracy: at least 1 µV.
Input signal range: from -1250 mV to +1250 mV.
Support for quantitative analysis methods:
External standard method.
Internal standard method.
Normalization method.
Automatic and manual peak integration.
Real-time chromatogram viewing.
Support for AIA format.
Batch data processing and automatic report generation.
Compatibility with operating systems not lower than Windows 10.
Configuration (per set)
Gas chromatograph: 1 unit.
Flame ionization detector: 1 unit.
Injector port: at least 1 unit.
Headspace autosampler: 1 unit:
Fully automatic.
Capacity: at least 20 vials.
Support for headspace analysis.
Software license: 1 unit.
Set of capillary columns and fittings: 1 set.
PC or laptop with pre-installed software: 1 unit.
Documentation in Russian: 1 copy
Hydrogen cylinder with regulator: 1 unit
Spare parts kit for 1 year of operation (filters, gaskets, septa, columns, liners, needles, vials).
Capillary Column
Designed for VOC analysis (acetic acid, ethanol, acetone, methanol, and specific toxicants in biological samples).
Length: at least 30 m.
Inner diameter: 0.25 mm.
Film thickness: 0.25 µm.
Polarity: hydrophilic or hydrophobic (depending on methods).
Operating Conditions
Ambient temperature: +10 °C to +35 °C.
Humidity: not more than 85% at 25 °C.
Power supply: 220–240 V, 50/60 Hz.
Warranty: at least 24 months.
Restoration of functionality in case of failure: within 30 working days.
Manufacturer Requirement
The manufacturer must be certified to ISO 9001 and ISO 13485 standards.
The potential supplier must provide copies of ISO 9001 and ISO 13485 certificates as part of the tender application.
Additional Requirements
Quantity: 5 sets.
Terms of warranty and post-warranty service.
Confirmation of equipment compliance with the specified parameters.
Copies of the manufacturer’s ISO 9001 and ISO 13485 certificates.
The proposal must be submitted in English or Russian.
Buyer is interested to receive quotations for the following RFQ -
Product Name: Sugar Refinery Machinery Spare Parts
Specifications:
Type :- For P.r. Red-038
For Final Molasses Pumps Spare Parts.
Bare Shaft (pump Only) Gear Pump
Note: Brand: Rotan Pump, Desmi A/s
Model: Hd101e-1u22b Serial #: 307950101 (1pc)
For P.r. Red-037
for Final Molasses Pumps Spare Parts.
2 pcs idler Rotan Pos Ab
4 pcs bush Idler Rotan Pos Ad
2 pcs bush Main Bearing Rotan Pos Bc
2 pcs pin Idler Rotan Pos Ac
Note: All Parts Of Rotan Pump, Desmi A/s,
Model: Hd101e-1u-22b Serial #; 307950101
For P.r. Red-034
for Refined Sugar Warehouse #14-#16 Belt Conveyor Geared Motor, Replacement And Spare
2 units geared Motor Model: Ka 87/t Dv 112 M4/bmg
Power: 4kw Voltage: 460vac, 60hz
Amps: 7.9amps Brake V: 440vac
Rectifier: Bge 1.5 Brand: Sew-euro Drive
2 units geared Motor Model: Ka 107/t Dv 160 M4
Power: 11kw Voltage: 460vac, 60hz
Amps: 20.5amps Brand: Sew-euro Drive
For P.r. Red-035
for Refined Sugar Warehouse #14-#16 Belt Conveyor Geared Motor, Replacement And Spare
2 units geared Motor Model: Ka 97/t Dv 132 S4/bmg
Power: 5.5kw Voltage: 460vac, 60hz Amps: 10.4amps Brake V: 440vac Rectifier: Bge 1.5
Brand: Sew-euro Drive
2 units brake Full Set, Bmg For Sew-euro Drive
Model: Ka 97/t Dv 132 S4/bmg Voltage: 460vac
Brand: Sew-euro Drive
For P.r. Phd-044
for Cogen Steam Trap Replacement
2 pcs thermodynamics Steam Trap, Bimetalic
Element 3/4" 800lbs Pn60, A216 Body
(or Better), Socket Weld Connection
Operating Condition Sh Steam @ 45bar (ci)
440°c (temp Range: 450°c Max) Brand: Spirax Sarco, Ari Germany Or Equivalent
For P.r. Mid-039
for Mill Repair Use
1 unit impact Wrench (cordless, Brushless) Brand : Makita Model : Dtw285rfjx
Complete Set Includes:
1 Unit Makita Dtw285rfjx Cordless Impact Wrench
1 Pc : Belt Clip
2 Pcs : Battery (18v 3.0 Ah Lxt Li-ion)
1 Pc : Charger
1 Pc : Makpac Type 2 Case (821550-0)
1 Pc : Socket Bit (b-65232)
1 Pc : Extension
For P.r. Bld-017
for Boiler Retubing (boiler Tube Expander (without Mandrel;, Thomas C. Wilson,
Inc
1 unit tube O.d. = 2" Tube Expander
Tube Wall Thickness = 3.66mm To 4.2mm
Tube Seat Thickness = 2-1/4"(57.15mm) To 3-1/4"
(82.55mm)
1 unit tube O.d. = 2-1/2“ Tube Expander
Tube Wall Thickness = 3.8mm To 4.57mm
Tube Seat Thickness = 2-1/4"(57.15mm) To 3-1/4"
(82 55mm)
1 unit tube O.d - 3" Tube Expander
Tube Wall Thickness - 3.8mm To 4.5mm
Tube Seat Thickness = 2-1/4"(57.15mm) To 3-1/4"
(82 55mm)
1 unit tube O.d. = 4" Tube Expander
Tube Wall Thickness = 3.4mm To 5.08mm
Tube Seat Thickness = 2-1/4"(57.15mmi To 3-1/4" (82.55mm)
Note: Please Advise Tube Seat Thickness For Each Tube Size So We Can Quote The Appropriate Tube Expander For The Job. For Tube Seat Thickness More Than 2-5/8" Thick, Step Expansion Is Required Which Requires 2 Types Of Expanders - Series 65 & Series 114. Supplier Can Quote Accordingly
For P.r. Bld-020
item 1- For Evaporator Set #4 Cell 2, 3, & 4 Tubes Use. Item 2- For Replacement Of Damaged Tube Expander For Juice Heater Use
1 unit expander Tube 1-1/2" Brand: Thomas Wilson
3 units expander Tube 1-1/2" Brand: Thomas Wilson
For P.r. Bld-020
for Inside Tube Cleaning/jta1 & Jta2 Boiler
4 sets hose Tube Cleaner Assy 1/2in X Soft 2 Braid, Armored Type Fig.3 Cat. 7053-0050 1/2 Npt
4 sets motor Air Set Ect-212 4090-0175 Set
Cat. No. 4090-0175
2 pcs head Cutter Assy T C. Wilson M-chj-212
4195-4606
Cat. No. 4195-4606
Ref: Thomas C Wilson Inc.
21-11 44thave.
Long Island City
NEW YORK
FOR P.R. MID-025
For B and l-Mill Hydraulic Top Caps
2 pcs CHESTERTON 22KE ULTRASEAL Materials: : Thermoset diamined core polymer seal shore 95A Pressure : 15,000 PSI Temp. : 85°C Tensile strength : 5,000 PSI Size : 390.2 x 360mm x 25mm H
3 pcs CHESTERTON 22 KPM ULTRA SEAL DOU-SEAL Materials: : Thermoset Diamined Cure Polymer Seal Shore 95A Pressure : 15,000 PSI
Tensile Strength : 5,000 PSI
Size :