Please quote for the following wholesale product requirement -

Product Name: Gas Chromatography Equipment

Specifications:
Purpose
The equipment is intended for the identification and quantitative determination of acetic acid, volatile poisons (e.g., chloroform, ethanol, methanol), and other volatile organic compounds (VOCs) from biological samples (blood, urine, internal organs) as part of forensic chemical-toxicological analysis.

Main Technical Specifications

Thermostatting System
Number of independent heating zones: at least 8.
Maximum column oven temperature: at least 460 °C.
Temperature programming rate: from 0.1 to at least 160 °C/min.
Number of temperature steps: at least 24.
Maximum hold time per temperature step: at least 999 minutes.
Temperature maintenance accuracy: not less than ±0.03 °C.
Temperature programming repeatability: not more than 1%.
Hardware and software overheat protection.

Gas Supply System
Number of electronic pressure control (EPC) channels: at least 13.
Gas flow range: from 0 to at least 999.999 ml/min.
Flow setting accuracy: at least 0.001 ml/min.
Pressure setting accuracy: at least 6.89 Pa.
Protection against heating activation without gas supply.
Injector System
Injector type: Split/Splitless with septum purge.

Maximum injector temperature: at least 450 °C

Support for direct injection mode.

Flame Ionization Detector (FID)
Detection limit: not more than 2 picograms/second (for n-hexadecane).
Operating temperature range: up to 450 °C.
Low background noise level.
High sensitivity to hydrocarbons and volatile organic compounds.
Software

Control of all gas chromatograph and autosampler parameters via PC.

Support for at least 4 channels for chromatographic signal acquisition.

Signal recording accuracy: at least 1 µV.

Input signal range: from -1250 mV to +1250 mV.
Support for quantitative analysis methods:
External standard method.
Internal standard method.
Normalization method.
Automatic and manual peak integration.
Real-time chromatogram viewing.
Support for AIA format.
Batch data processing and automatic report generation.
Compatibility with operating systems not lower than Windows 10.

Configuration (per set)
Gas chromatograph: 1 unit.
Flame ionization detector: 1 unit.
Injector port: at least 1 unit.
Headspace autosampler: 1 unit:
Fully automatic.
Capacity: at least 20 vials.
Support for headspace analysis.
Software license: 1 unit.
Set of capillary columns and fittings: 1 set.
PC or laptop with pre-installed software: 1 unit.
Documentation in Russian: 1 copy

Hydrogen cylinder with regulator: 1 unit

Spare parts kit for 1 year of operation (filters, gaskets, septa, columns, liners, needles, vials).

Capillary Column

Designed for VOC analysis (acetic acid, ethanol, acetone, methanol, and specific toxicants in biological samples).
Length: at least 30 m.
Inner diameter: 0.25 mm.
Film thickness: 0.25 µm.
Polarity: hydrophilic or hydrophobic (depending on methods).

Operating Conditions
Ambient temperature: +10 °C to +35 °C.
Humidity: not more than 85% at 25 °C.
Power supply: 220–240 V, 50/60 Hz.
Warranty: at least 24 months.

Restoration of functionality in case of failure: within 30 working days.

Manufacturer Requirement



The manufacturer must be certified to ISO 9001 and ISO 13485 standards.

The potential supplier must provide copies of ISO 9001 and ISO 13485 certificates as part of the tender application.

Additional Requirements

Quantity: 5 sets.
Terms of warranty and post-warranty service.
Confirmation of equipment compliance with the specified parameters.
Copies of the manufacturer’s ISO 9001 and ISO 13485 certificates.

The proposal must be submitted in English or Russian.

Contact : Alikhan Muratov

 
 
Contact Buyer
Renew

More Items Similiar to: Wanted : Gas Chromatography Equipment

VERIFIED
Aug-19-25
Buyer From Saudi Arabia
Quantity Required: Not specified
Payment Terms: Bank Transfer
Destination: Saudi Arabia
Looking for suppliers from: Worldwide
Product Description
ARCHIVED
May-26-21
Buyer From Oman
Quantity Required: 100 Units
Payment Terms: To be discussed with suppliers
Destination: Oman
Looking for suppliers from: Worldwide
Product Description
ARCHIVED
Mar-11-22
Buyer From Osaka , Japan
Quantity Required: 50 Sets
Payment Terms: T/T Or L/C
Destination: Osaka, Japan
Looking for suppliers from: Worldwide
Product Description
Oct-04-19
Buyer From Kolkata, Wb, India
Oct-19-21
Buyer From Kuwait
Jun-18-22
Buyer From Dubai, United Arab Emirates
VERIFIED
Oct-07-25
Buyer From India
Quantity Required: 1 Set
Payment Terms: LC
Destination: India
Looking for suppliers from: Worldwide
Product Description
Apr-14-19
Buyer From Dombivali, Maharashtra, India
Feb-19-24
Buyer From Bahrain