short circuit&earth fault indicator widely used in ABB/SIEMENS switchgears:
1. Short circuit alarming current: 100A to 1000A time delay 40ms
2. Earthing alarming current: 10A, 20A,30A,40A,60A±10% time delay 40ms
3. Temperature range : -25 to +70
4. Humidty range: â?¦95%
5. Earth lead length : 4m optional
6. Conduct optical fiber length 3.5m optional
7. Power supply: lithium battery 3.6V/2.45Ah
8. Auto-reset time : 7s,2hrs,4hrs,8hrs
9. Output relay : 125 V AC 1A, 30V DC 2A
10.Main controller dimension : 95*50*80mm
11.Cutting hole size : 91*44 mm
12.Protection class : Main Controller :IP40, Sensor:IP65
Portable earthing and earthing short-circuit are used for temporary earthing of electric power and rail transit during overhaul construction to ensure the safety of workers.
Performance Standard: DL/T879 -2004 portable earthing and earthing short circuit equipment for live workingï¼?
Material requirements: high purity copper wire, copper purityâ?¥99.999% .
Technical parameters: the grounding wire is made of many strands of soft copper wire, the diameter of the single wire is not more than 0.2 mm, and the surface is covered with transparent insulating layer (including the grounding wire, where it is connected with the end clamp of the grounding wire) , the thickness of the protective layer is not more than 1.5 mm.
The installation of the terminal adopts the secondary drawing process. The transparent sheath of the grounding line is installed in the pipe and the spring is added to form the secondary protection, therefore, the copper wire can not be broken during the use, and the transparent heat-shrinkable tube is used for the terminal sheath to observe whether the ground wire has been broken or not.
Earthing System is very essential to be properly designed & installed to safeguard both lives & the equipment. Sometimes it happens that though the earthing system is installed, current leakage is felt & short circuit may happen. To avoid this a correct Earthing System embracing correct earthing accessories is very important to take care of. Corrosion resistance, conductivity and mechanical strength are essential considerations in earthing accessory design to ensure an earthing system remains operative for many years. All AMPL Earthing Accessories have high quality copper alloy material which provide wanted strength to the part to ensure its proper mechanism. Material: Brass - Gunmetal - Bronze - copper - SS - are main metals used in manufacturing the equipments in the form of clamps, nut bolts. Sizes & Types: Rain Water Pipe Bond, Jointing Clamp, B-Bond, Tee-Clamp, U Bolt Rod to Cable Clamp, Tower Bond Clamp, U Bolt Rod to Cable Clamp, U Bolt Rod to Cable Clamp, U Bolt Rod Clamp, Rod to Cable Lug Clamp. Finish: Natural, Nickel, Tin or any coating as per custom specification.
Copper ore is a naturally occurring mineral rock that contains copper in varying concentrations. It's extracted from the earth through mining and then processed to produce copper concentrate, which is further refined to produce pure copper.
## Types of Copper Ore
1. Sulfide ores: These ores contain copper in the form of sulfide minerals, such as chalcopyrite (CuFeS2), bornite (Cu5FeS4), and chalcocite (Cu2S).
2. Oxide ores: These ores contain copper in the form of oxide minerals, such as cuprite (Cu2O), tenorite (CuO), and malachite (Cu2CO3(OH)2).
3. Native copper: This type of ore contains copper in its native form, often found in quartz veins or other igneous rocks.
## Copper Ore Deposits
1. Porphpyry copper deposits: These deposits are formed through magmatic-hydrothermal processes and are characterized by large, low-grade copper deposits.
2. Volcanogenic massive sulfide (VMS) deposits: These deposits are formed through volcanic activity and are characterized by high-grade copper deposits.
3. Sedimentary copper deposits: These deposits are formed through sedimentary processes and are characterized by low-grade copper deposits.
## Major Copper-Producing Countries
1. Chile: The world's largest copper producer, accounting for approximately 30% of global production.
2. Peru: The second-largest copper producer in South America.
3. Australia: A significant copper producer, with major mines in Western Australia.
4. United States: Copper is mined in several states, including Arizona, Utah, and Montana.
5. China: A major copper producer and consumer, with significant mining and smelting operations.
Uses of Copper Ore
1. Copper production: Copper ore is processed to produce copper concentrate, which is then refined to produce pure copper.
2. Electrical applications: Copper is an excellent conductor of electricity, making it a crucial material for electrical wiring, circuits, and electronic devices.
3. Construction and architecture: Copper is used in building construction, including roofing, plumbing, and electrical systems.
4. Industrial machinery and equipment: Copper is used in the production of various industrial machinery and equipment, including motors, generators, and transformers.
3358 Short Circuit And Earth Fault Indicator Dj 3100 Suppliers
Short on time? Let Short Circuit And Earth Fault Indicator Dj 3100 sellers contact you.
Performance Standard: DL/T879 -2004 for live working portable earthing and earthing short circuit device;
Material requirements: wire clamp made of aluminum or copper alloy casting, good conductivity, holding firm. The insulating rod adopts high strength epoxy glass fiber pipe,
which has high mechanical strength and good insulation performance. The handle is made of insulating rubber, non-slip and good grip.
Gbcdg21af106znch
Idmt Earth Fault Relay With High Set
Relay Model Number Cdg21af106znch
Cdg21
Application E/f
Burden 3va
C.t. Secondary 1 Amp Ct.
Case Size 1d V 10t
Contacts (S/r or H/r) 2 N/o 1 N/c H/r
D.m.t 3 Sec.
E/f or U/v Setting 0.1 to 0.4 a
Flag Yes
Frequency 50 Hz
High Set Type Cag17
Highset Contacts 2m S/r
Highset E/f Setting 1 to 8 a
Highset O/c Setting Not Applicable
Mounting Flush
O/c or O/v Setting Not Applicable
Name Plate-1 Rfg9126 692
Outline Drawing Mfj 012
Wiring Diagram Madz821.32
Gbcdg21af116znch
Idmt Earth Fault Relay With High Set
Technical Specification
Relay Model Cdg21af116znch
Relay Type Cdg21
Application E/f
Burden 3va
C.t. Secondary 1 Amp Ct.
Case Size 1d V 10t
Contacts (S/r or H/r) 2 N/o 1 N/c H/r
D.m.t 1.3 Sec
E/f or U/v Setting 0.1 to 0.4 a
Flag Yes
Frequency 50 Hz
High Set Type Cag17
Highset Contacts 2m S/r
Highset E/f Setting 1 to 8a
Highset O/c Setting Not Applicable
Mounting Flush
O/c or O/v Setting Not Applicable
Name Plate-1 Rfg9125 692
Outline Drawing Mfj 012
Wiring Diagram Madz821.32
ALSTOM GBCDG21AF8201SKCH
IDMT EARTH FAULT RELAY WITH HIGH SET CA
Technical specification
Model Number CDG21AF8201SKCH
Relay type CDG21
Case Size 1D S/E
Application E/F S/T
Current Setting 1 TO 4 Amps
Contacts 2 N/O 2 N/C H/R
Output Contacts 2 N/O 2 N/C H/R
Flag Yes
Taps STD
C.T.Secondary 5 Amps
Burden / Operating Time 3 Va / 3 Secs
High Set Contacts 2 N/O S/R
High Set CAG 17
Frequency 50 Hz
High Set Cur.Setting 5 TO 40 Amps
Name Plate RFG9126 796
Outline Drawing MFJ 012
Wiring Diagram MADZ821.33
SUMMARY
SNV308.1 series overhead type Fault Indicator system is based on the Sensor that through CT get the (6KV-50KV) lineâ??s current signal, through smart computer chip(IC) by program calculating, Analysis ,judge the short circuit or ground fault. When Sensor detect the fault happen, then the Fault indicator warn the manager through turn red flag, and shine 3 color ultra-led. It is good for power managing user to find the fault happen reason and place, then fast solve the problem and make the power restore.
*SNV308.1 Fault Indicator with the aid of the remote control PDA(SNV306.1), User can read, reset the indicatorâ??s setting parameter, and can read the online real time current etc
*SNV308.1 Fault Indicator with the aid of the professional control terminal equipment(SNV309.1) and Web server, it can achieve to remote read and manage the Fault indicator state on times.
There are two channels for reading and managing the remote fault indicators. One is through GSM mobile phone SMS command control. Second is user computer software control. Power managing user, can get the fault indicator information on times
An Earth Leakage circuit breaker (ELCB) (now referred to as residual current circuit breaker-RCCB) is a safety device used in electrical installation with high earth impedance to prevent shock. High Quality circuit breaker (ELCB’S) Manufacturer and Exporters provides Automatic models as well as manual models ELCB’s.
Earth leakage circuit breaker
The elcb is micro controller based with shock guard which continuously displays all the parameters and with inbuilt seven segment display and indicates the reason for tripping.
place of origin : Zhejiang Province,China(Mainland)
brand name : NIN
type : AD16-22W/D
color : white green red yellow blue
lamp voltage : DC/AC 6V 12V 24V 36V 48V 110V 220V 380V
lamp life : more than 30000 hours
IP rating : IP65
If you are interested in our products,please contact us, we will reply you as soon as possible.