Product Description :
The PaxView COVID -19 real-time RT-PCR Kit detects the novel coronavirus, COVID-19 using one-step real-time RT-PCR in a single tube intended for in vitro diagnostic use. The target genes for the detecton of the virus are Orf1ab and N gene. The sequence of primers and probes for the amplification were adapted from sources published by China CDC and WHO. The kit includes primers and probe set targeting the human RNase P gene that serves as an internal positive control for the real-time RT-PCR.
Price of product ( USD price or FOB price) :
1no testing 20 USD
Key Specifications/Special Features :
1. with in 3hour testing result in come
2. One item 96person can check
3. 100% correct result coming then other method
4. It is same process in korea
Minimum Order Size and Packgaing details :
50kit in box
500 x 460 x350 6kg
MOQ : 500
Our test kit has been approved and endorsed by Singapore's MOH (Ministry of Health) and HSA (Health Science Authority) since last year and we have been constantly supplying to the APAC countries during this period. (Japan, India, Singapore, Malaysia, Indonesia and etc.)
* CE mark was attained in December 2020. *
Our Tepat 1.0 SARS-CoV-2 RT-PCR provides for high-throughput, sensitive and specific detection of SARS-CoV-2 RNA extracted from nasopharyngeal swabs*.
It can detect 6 copies of viral RNA per reaction with > 95% confidence. Clinical validation shows 100% sensitivity, with no cross-reaction with non-SARS-CoV-2 species.
Key Highlights
1.5 hours from RNA to results
Multiplex RdRp and M viral genes detection enhances sensitivity and specificity
100% coverage with 100% identity of all SARS-CoV-2 genomes in the world
Detects 6 copies of viral RNA
Whole process control: human RNase P
Product Details:
Number of Reactions(Preps) per Kit : 100
Brand : Seegene
ICMR(Govt) Approved : Yes
Test Method : (SARS-CoV-2) RT-PCR
Test Time : 2 Hours
Cat. No : RP10243X
-Detection of COVID-19 specific target genes in a single tube- Reliable result with three target genes- Results within 1 hour and 50 minutes after extraction- Convenient workow on the automated MDx platform- Suitable for high-throughput- Providing whole process control for assay validity- Automated data interpretation with Seegene Viewer
Cat No : RP10243X. Detection of COVID-19 specific target genes in a single tube- Reliable result with three target genes- Results within 1 hour and 50 minutes after extraction- Convenient work now on the automated MDx platform- Suitable for high-throughput- Providing whole process control for assay validity- Automated data interpretation with Seegene Viewer.
- RT-PCR Test Kit Manufactured from South Korea
- FDA EUA
- CE
- ISO
- 1 Kit = 100 Tests
- MOQ = 30,000 Tests or 300 Kits
- Price is $11.00 per test or $1,100 per test kit
COVID-19 RT-PCR TEST - NO RNA PURIFICATION NEEDED!
Results in less than 60 minutes, very easy-to-use.
Made in USA, with clinical validations all over the world.
FDA-EUA approved and CE cleared.
The COVID-19 RT-PCRT est is a real-time reverse transcription polymerase chain reaction (rRT -PCR) test. The test can be run in a singleplex format (three individual assays) or multiplexed into a single reaction and amplification set up.
Cat. No : 601430050. Truenat COVID-19 Chip-based Real Time PCR Test is a semi quantitative detection of SARS CoV-2 RNA in human oropharyngeal and nasopharyngeal swab specimen and aids in detection and confirmation of SARS CoV-2 infection and diagnosis of COVID-19. The test detects the E and Orf1a genes of the virus.
Providing you the best range of Molbio Trueprep Auto Universal Cartridge Based Sample Prep Device, Molbio Trueprep AUTO Universal Cartridge Based Sample Prep Kit, Molbio Trueprep AUTO MTB Sample Pre Treatment Pack Kit, Molbio Trueprep AUTO Universal Sample Pre-treatment Pack and Molbio Trueprep AUTO Transport Medium for Swab Specimen Pack with effective & timely delivery.
Sample Types :
Including Nasopharyngeal swab, Oropharyngeal swab, Sputum
Controls :
Internal control, UNG enzyme and dUTP used to reduce risk of contamination, false positive and false negative results
Product Information
Upper and lower respiratory specimens such as anterior nasal swabs, mid-turbinate nasal swabs, nasopharyngeal swabs, oropharyngeal swabs, sputum, lower respiratory tract aspirates, bronchoalveolar lavage, and nasopharyngeal wash/aspirate or nasal aspirate.
Authorized Laboratories
Laboratories certified under the Clinical Laboratory Improvement Amendments
of 1988 (CLIA), 42 U.S.C. 263a, to perform high complexity tests.
About Emergency Use Authorization
(EUA)
This test (1) has not been FDA cleared or approved, (2) has been authorized by
FDA under an EUA for use by authorized laboratories, (3) has been authorized
only for the detection of nucleic acid from SARS-CoV-2, not for any other
viruses or pathogens, and (4) is only authorized for the duration of the declaration that circumstances exist justifying the authorization of emergency use of in vitro diagnostics for detection and/or diagnosis of COVID-19 under Section 564(b)(1) of the Act, 21 U.S.C.360bbb-3(b)(1), unless the authorization
is terminated or revoked sooner.
The COVID-19 RT-PCR Detection Kit is a real-time RT-PCR test intended for the qualitative detection of nucleic acid from the SARS-CoV-2 in upper and lower respiratory specimens (such as anterior nasal swabs, mid-turbinate nasal swabs, nasopharyngeal swabs, oropharyngeal swabs, sputum, lower respiratory tract aspirates, bronchoalveolar lavage, and nasopharyngeal wash/aspirate or nasal
aspirate) from individuals suspected of COVID-19 by their healthcare provider. Testing is limited to laboratories certified under the Clinical Laboratory Improvement Amendments (CLIA) of 1988, 42 U.S.C.
263a, to perform high complexity tests.
Results are for the identification of SARS-CoV-2 RNA. The SARS-CoV-2 RNA is generally detectable in upper and lower respiratory specimens during the acute phase of infection. Positive results are indicative of the presence of SARS-CoV-2 RNA; clinical correlation with patient history and other diagnostic information is necessary to determine patient infective status. The agent detected may not be
the definite cause of disease. Positive results do not rule out bacterial co-infection with other viruses.
Laboratories within the United States and its territories are required to report all positive results to the appropriate public health authorities.
Negative results do not preclude SARS-CoV-2 infection and should not be used as the sole basis for patient management decisions. Negative results must be combined with clinical observations, patient history, and epidemiological information.
The COVID-19 RT-PCR Detection Kit is intended for use by qualified trained clinical laboratory personnel specifically instructed and trained in the techniques of real-time PCR and in vitro diagnostic procedures. The COVID-19 RT-PCR Detection Kit is only for use under the Food and Drug Administration's Emergency Use Authorization.
PRINCIPLE OF DETECTION
This product is a fluorescent probe-based Taqman RT-PCR assay system. Firstly, the RNA of SARS-CoV-2 will be reverse transcribed into cDNA by reverse transcriptase, and then PCR amplification will be performed with cDNA as template. During amplification of the template, the TaqMan probe will
be degraded due to the 5'-3 polymerase activity and exonuclease activity of Taq DNA polymerase, then the separation of fluorescent reporter and quencher enables the fluorescent signal to be detected by instrument. The ORF1ab gene of SARS-CoV-2 will be detected qualitatively by FAM channel, the N
gene of SARS-CoV-2 will be detected qualitatively by JOE channel, the E gene of SARS-CoV-2 will be detected qualitatively by ROX channel, and the internal reference will be detected by CY5 channel.
dUTP and UNG enzyme are used in the kit to prevent contamination of the amplified products.
Internal reference is used in the kit for quality control starting from sample collection
Indication: Qualitative detection of nucleic acid from SARS-CoV-2 in upper
and lower respiratory specimens (such as anterior nasal swabs, mid-turbinate nasal swabs, nasopharyngeal swabs, oropharyngeal swabs, sputum, lower respiratory tract aspirates, bronchoalveolar lavage, and nasopharyngeal wash/aspirate or nasal aspirate) from individuals suspected of COVID-19 by their healthcare provider.
Emergency use of this test is limited to authorized laboratories.
Authorized Laboratories: Laboratories certified under the Clinical Laboratory Improvement Amendments of 1988 (CLIA), 42 U.S.C. 263a, to perform high
complexity tests.
This letter is in response to your1 request that the Food and Drug Administration (FDA) issue an Emergency Use Authorization (EUA) for emergency use of your product,2 pursuant to Section 564 of the Federal Food, Drug, and Cosmetic Act (the Act) (21 U.S.C. 360bbb-3). On February 4, 2020, pursuant to Section 564(b)(1)(C) of the Act, the Secretary of the
Department of Health and Human Services (HHS) determined that there is a public health emergency that has a significant potential to affect national security or the health and security of United States citizens living abroad, and that involves the virus that causes COVID-19.
Pursuant to Section 564 of the Act, and on the basis of such determination, the Secretary of HHS then declared that circumstances exist justifying the authorization of emergency use of in vitro diagnostics for detection and/or diagnosis of the virus that causes COVID-19 subject to the terms of any authorization issued under Section 564(a) of the Act.
Having concluded that the criteria for issuance of this authorization under Section 564(c) of the Act are met, I am authorizing the emergency use of your product, described in the Scope of Authorization of this letter (Section II), subject to the terms of this authorization.
I. Criteria for Issuance of Authorization I have concluded that the emergency use of your product meets the criteria for issuance of an authorization under Section 564(c) of the Act, because I have concluded that:
1. The SARS-CoV-2 can cause a serious or life-threatening disease or condition,
including severe respiratory illness, to humans infected by this virus;
2. Based on the totality of scientific evidence available to FDA, it is reasonable to believe that your product may be effective in diagnosing COVID-19, and that the known and potential benefits of your product when used for diagnosing COVID-19, outweigh the known and potential risks of your product; and, 3. There is no adequate, approved, and available alternative to the emergency use of your
product.
4
II. Scope of Authorization
I have concluded, pursuant to Section 564(d)(1) of the Act, that the scope of this authorization is limited to the indication above.
Commodity: Covid-19 RT-PCR Detection Kit
Spec.96 tests/kit
Price:FOB SHANGHAI USD3.30/test, USD316.8/kit
$3.60/TEST CIF NY AIRPORT OR OTHER MAJOR AIRPORTS USA OR EUROPE OR S. AMERICA OR MIDDLE EAST
Payment: T/T ADVANCE 50% BALANCE BEFORE DEPARTURE OR Sight Irrevocable TRANSFERABLE LC Delivery: By AIR, 50days after receipt and confirmation of LC
RT PCR TEST KITS FOR COVID ARE AVAILABLE DIRECTLY FROM MANUFACTURERS IN SOUTH KOREA.
No intermediaries.
Please contact For quotes only if you are a buyer.
ThermoFisher Scientific Accula System Rapid & Reliable RT-PCR Test for Corona in 30mins
Product Details:
Number of Reactions(Preps)/Kit : 25
Brand : Thermo
Test Method : (SARS-CoV-2) RT-PCR
Sample Type : Nasal Swab
Test Time 30 min
The Accula System from Thermo Fisher Scientific is a rapid diagnostic platform that combines the accuracy of RT-PCR with the simplicity, convenience, and procedural familiarity of traditional rapid immunoassays. The Acculaâ?¢ SARS-CoV-2 Test has received an Emergency Use Authorization (EUA) from the FDA for the detection of SARS-CoV-2 in Clinical Laboratory Improvement Amendments (CLIA) waived environments. Designed for use with the palm-sized Accula Dock, the Accula SARS-CoV-2 Test provides reliable, qualitative results in approximately 30 minutes
Cov-inu RT-PCR kit is a probe based Real Time PCR test designed for the qualitative de- tection of SARS-CoV-2 Coronavirus, the etiological agent of COVID-2019 and A + B Group Inuenza virus (orthomyxovirus). It is used to detect S- M2 ve NS1 genes in viral RNA.
Description of the Kit
Cov-inu RT PCR Kit is a multiplex PCR kit that is used for the simultaneous detection of COVID-19 agent SARS-COV-2 and Inuenza A and Inuenza B viruses from the same sample. Coronaviruses are a large family of viruses that cause infections in humans and other mammals (such as camels, cats, dogs, and bats). The SARS-CoV-2 virus is a new coronavirus that was identified by the World Health Organization (WHO) (1) on February 11, 2020. Inuenza is caused by three types of immunological RNA viruses (A, B and C) in the Orthomyxoviridae family. Seasonal inuenza is typically caused by three main hem- agglutinin subtypes (H1, H2, and H3) and two neuraminidase subtypes (N1 and N2). It is important that public health laboratories around the world conduct detailed surveillance to monitor the spread and impact of the pandemic H1N1 2009 virus, as well as predict future changes in virulence (4). Therefore, methods for rapid diagnosis, case detection and follow-up of this new pathogen in the human population are necessary to develop appropriate management strategies to reduce morbidity and mortality. The test works with single-stage real time reverse transcriptase polymerase chain reaction (On- eStep RT-PCR) with serum, lower respiratory tract samples (e.g. bronchoalveolar lavage, sputum, tracheal aspirate), and upper respiratory tract samples (e.g. nasopharyngeal uids, nasal swab) from individuals who demonstrate clinical criteria set for COVID-19 by WHO (2) and CDC (Center for Disease Control and Prevention) (3). This kit is an In-vitro diagnostic kit using specific primers designed for qualitative detection of genomic RNAs of SARS-CoV-2, Inuenza A and Inuenza B virus.