Find Verified Non Directional Inv Time 3O C Or 2O C 1E Suppliers, Manufacturers and Wholesalers

VERIFIED
Jun-18-21
 
GBCDG31EG001SACH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No : CDG31EG001SA(M)
CDG31
APPLICATION - 3 O/C
BURDEN / D.M.T - 3 VA / 3 SEC.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O S/R
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 2.5 - 10 Amps.
Name Plate RFG9126774
Outline Diagram MFJ014
Wiring Diagram MADZ802.63-1
VERIFIED
Jun-18-21
 
GBCDG31EG001SBCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Technical Specifications
Model No - CDG31EG001SBCH
RELAY TYPE - CDG 31
APPLICATION - 2 O/C + 1 E/F
BURDEN / D.M.T - 3 VA / 3 SECS.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F SETTING - 1 - 4 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 2.5 - 10 Amps.
NAME PLATE - RFG9126 904
Outline Diagram MFJ 014
Wiring Diagram MADZ802.63-1
VERIFIED
Jun-18-21
 
GBCDG31EG001SCCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No : CDG31EG001SC(M)
CDG31
APPLICATION - 3 O/C
BURDEN / D.M.T - 3 VA /3 SEC.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 2.5 - 10 Amps.
Name Plate RFG9126674
Outline Diagram MFJ014
Wiring Diagram MADZ802.64-1
VERIFIED
Jun-18-21
 
GBCDG31EG001SDCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No - CDG31EG001SD(M)
RELAY TYPE - CDG 31
APPLICATION - 2 O/C + 1 E/F
BURDEN / D.M.T - 3 VA / 3 SEC.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F SETTING - 1 - 4 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 2.5 - 10 Amps.
Name Plate - RFG9126 904
Outline Diagram MFJ 014
Wiring Diagram MADZ802.64-1
VERIFIED
Jun-18-21
 
GBCDG31EG002SACH
NON DIR.SELF POWER 3 O/C RELAY 2M S/R
TECHNICAL SPECIFICATION
Model No : CDG31EG002SACH
CDG31
APPLICATION - 3 O/C
BURDEN / D.M.T - 3 VA / 3 SEC.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O S/R
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C OR O/V SETTING - 0.5 - 2 Amps.
Name Plate RFG9126771
Outline Diagram MFJ014
Wiring Diagram MADZ802-63-1
17114 Non Directional Inv Time 3O C Or 2O C 1E Suppliers
Short on time? Let Non Directional Inv Time 3O C Or 2O C 1E sellers contact you.
VERIFIED
Jun-18-21
 
GBCDG31EG002SBCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
MODEL NO - CDG31EG002SBCH
RELAY TYPE - CDG 31
APPLICATION - 2 O/C + 1 E/F
BURDEN / D.M.T - 3 VA / 3 SEC.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F SETTING - 0.5 - 2 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 2.5 - 10 Amps.
NAME PLATE - RFG9126 903
Outline Diagram MFJ 014
Wiring Diagram MADZ802.63-1
VERIFIED
Jun-18-21
 
GBCDG31EG002SCCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Technical specification
Relay Model No CDG31EG002SC(M)
Relay type CDG31
CASE SIZE 3D HORZ.
APPLICATION 3 O/C
O/C SETTING 0.5 - 2 Amps
BURDEN / D.M.T 3 VA / 3 SEC.
Taps Std
C.T. SECONDARY 1 AMP CT.
CONTACTS (S/R OR H/R) 2 N/O 2 N/C H/R
FLAG YES
FREQUENCY 50 HZ
MOUNTING FLUSH
Name Plate RFG9126 671
Outline Diagram MFJ 014
Wiring Diagram MADZ802.64-1
VERIFIED
Jun-18-21
 
GBCDG31EG002SDCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Technical Specifications
Relay model No CDG31EG002SDCH
Relay type CDG 31
Case size 3D H 30T
Application 2 O/C + 1 E/F
Current setting - O/C 2.5 to 10 amps
( 50-200% )
Contacts (S/R OR H/R) 2 N/O 2 N/C H/R
Output Contacts 2 N/O 2 N/C H/R
Taps / Burden Std / 3 VA
C.T.Secondary 5 amps
D.M.T 3 secs
Current setting - E/F 0.5 to 2 amps
(10 - 40% )
Flag / Mounting Yes / Flush
Frequency 50 Hz
Name plate RFG9126 903
Outline Diagram MFJ 014
Wiring Diagram MADZ 802.64-1
VERIFIED
Jun-18-21
 
GBCDG31EG003SACH
NON DIR.SELF POWER 3 O/C RELAY 2M S/R
Technical specification
Relay Model No CDG31EG003SACH
Relay type CDG 31
Case size 3D Hor.
Application 3 O/C
Current setting 0.2 to 0.8 amps
Contacts (S/R OR H/R) 3 N/O S/R
Output contacts 2 N/O S/R
Burden / Operating Time 3 VA / 3 Secs.
C.T.Secondary 1 amps
Taps / frequency Std / 50 Hz.
Note:-write in name plate as
over current instead of E/F.
And Erase E/F symbol.
Flag Yes
Mounting Flush
Name Plate RFG9126 793
Outline Diagram MFJ 014
Wiring Diagram MADZ802.63-1
VERIFIED
Jun-18-21
 
GBCDG31EG003SBCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No - CDG31EG003SB(M)
RELAY TYPE - CDG 31
APPLICATION - 2 O/C + 1 E/F
BURDEN / D.M.T - 3 VA / 3 SEC.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F SETTING - 0.2 - 0.8 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 0.5 - 2 Amps.
NAME PLATE - RFG9126 902
Outline Diagram MFJ014
Wiring Diagram MADZ802.63-1
VERIFIED
Jun-18-21
 
GBCDG31EG003SDCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No - CDG31EG003SD(M)
RELAY TYPE - CDG 31
APPLICATION - 2 O/C + 1 E/F
BURDEN / D.M.T - 3 VA / 3 SEC.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F SETTING - 0.2 - 0.8 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 0.5 - 2 Amps.
Name Plate - RFG9126 902
Outline Diagram MFJ 014
Wiring Diagram MADZ802.64-1
VERIFIED
Jun-18-21
 
GBCDG31EG004SBCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No - CDG31EG004SB(M)
RELAY TYPE - CDG 31
APPLICATION - 2 O/C + 1 E/F
BURDEN /D.M.T - 3 VA /3 SEC.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F SETTING - 0.1 - 0.4 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 0.5 - 2 Amps.
Name Plate - RFG9126 901
Outline Diagram MFJ014
Wiring Diagram MADZ802.63-1
VERIFIED
Jun-18-21
 
GBCDG31EG004SDCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No - CDG31EG004SD(M)
RELAY TYPE - CDG 31
APPLICATION - 2 O/C + 1 E/F
BURDEN / D.M.T - 3 VA / 3 SEC.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F SETTING - 0.1 - 0.4 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 0.5 - 2 Amps.
Name Plate - RFG9126 901
Outline Diagram MFJ 014
Wiring Diagram MADZ802.64-1
VERIFIED
Jun-18-21
 
GBCDG31EG011SACH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No : CDG31EG011SA(M)
CDG31
APPLICATION - 3 O/C
BURDEN / D.M.T - 3 VA / 1.3 SEC
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O S/R
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 2.5 - 10 Amps.
Name Plate RFG9125 674
Outline Diagram MFJ014
Wiring Diagram MADZ802.63-1
VERIFIED
Jun-18-21
 
GBCDG31EG011SBCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No - CDG31EG011SB(M)
RELAY TYPE - CDG 31
APPLICATION - 2 O/C + 1 E/F
BURDEN /D.M.T - 3 VA / 1.3 SEC.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F SETTING - 1 - 4 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 2.5 - 10 Amps.
Name Plate - RFG9125 904
Outline Diagram MFJ014
Wiring Diagram MADZ802.63-1
VERIFIED
Jun-18-21
 
GBCDG31EG011SCCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No : CDG31EG011SC(M)
CDG31
APPLICATION - 3 O/C
BURDEN / D.M.T - 3 VA / 1.3 SEC.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 2.5 - 10 Amps.
Name Plate RFG9125 674
Outline Diagram MFJ014
Wiring Diagram MADZ802.64-1
VERIFIED
Jun-18-21
 
GBCDG31EG011SDCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No - CDG31EG011SDCH
RELAY TYPE - CDG 31
APPLICATION - 2 O/C + 1 E/F
BURDEN / D.M.T - 3 VA / 1.3 SEC.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
E/F SETTING - 1 - 4 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 2.5 - 10 Amps.
NAME PLATE - RFG9125 904
Outline Diagram MFJ 014
Wiring Diagram MADZ802.64-1
VERIFIED
Jun-18-21
 
GBCDG31EG012SACH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No : CDG31EG012SA(M)
CDG31
APPLICATION - 3 O/C
BURDEN / D.M.T - 3 VA / 1.3 SEC
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O S/R
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 0.5 - 2 Amps.
Name Plate RFG9125 671
Outline Diagram MFJ014
Wiring Diagram MADZ802.63-1
VERIFIED
Jun-18-21
 
GBCDG31EG012SBCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No - CDG31EG012SB(M)
RELAY TYPE - CDG 31
APPLICATION - 2 O/C + 1 E/F
BURDEN / D.M.T - 3 VA / 1.3 SEC.
C.T. SECONDARY - 5 AMP C.T.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F SETTING - 0.5 - 2 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 2.5 - 10 Amps.
Name Plate - RFG9125 903
Outline Diagram MFJ014
Wiring Diagram MADZ802.63-1
VERIFIED
Jun-18-21
 
GBCDG31EG012SCCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No : CDG31EG012SC(M)
CDG31
APPLICATION - 3 O/C
BURDEN / D.M.T - 3 VA / 1.3 SEC.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 3D HORZ.
CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 0.5 - 2 Amps.
Name Plate RFG9125 671
Outline Diagram MFJ014
Wiring Diagram MADZ802.64-1